Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Int J Mol Sci ; 25(2)2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38256151

RESUMEN

Cardiovascular diseases (CVDs) increasingly burden health systems and patients worldwide, necessitating the improved awareness of current treatment possibilities and the development of more efficient therapeutic strategies. When plaque deposits narrow the arteries, the standard of care implies the insertion of a stent at the lesion site. The most promising development in cardiovascular stents has been the release of medications from these stents. However, the use of drug-eluting stents (DESs) is still challenged by in-stent restenosis occurrence. DESs' long-term clinical success depends on several parameters, including the degradability of the polymers, drug release profiles, stent platforms, coating polymers, and the metals and their alloys that are employed as metal frames in the stents. Thus, it is critical to investigate new approaches to optimize the most suitable DESs to solve problems with the inflammatory response, delayed endothelialization, and sub-acute stent thrombosis. As certain advancements have been reported in the literature, this review aims to present the latest updates in the coatings field for cardiovascular stents. Specifically, there are described various organic (e.g., synthetic and natural polymer-based coatings, stents coated directly with drugs, and coatings containing endothelial cells) and inorganic (e.g., metallic and nonmetallic materials) stent coating options, aiming to create an updated framework that would serve as an inception point for future research.


Asunto(s)
Enfermedades Cardiovasculares , Células Endoteliales , Humanos , Enfermedades Cardiovasculares/terapia , Arterias , Aleaciones , Polímeros
2.
J Mater Sci Mater Med ; 33(1): 9, 2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-34982233

RESUMEN

In recent years, along with the development and application of magnesium alloys, magnesium alloys have been widely used in automotive, aerospace, medicine, sports, and other fields. In the field of medical materials, magnesium not only has the advantage of light weight, high strength, and a density similar to that of human bone, but also has good biocompatibility and promotes the growth of human bone. However, the mechanical properties and corrosion resistance of magnesium alloys need to be further improved to meet the requirements for human biodegradable implants. In this study, three alloys (mass fractions: Mg-10Zn, Mg-20Zn, and Mg-30Zn (wt.%)) were prepared using powder metallurgy by homogeneously mixing powders of the above materials in a certain amount with magnesium as the substrate through the addition of zinc elements, which also have good biocompatibility. The effect of zinc on the microstructure, mechanical properties, wear performance, and corrosion resistance of magnesium-zinc alloys was studied when the zinc content was different. The results show that compared with the traditional magnesium alloy using powder metallurgy, prepared magnesium alloy has good resistance to compression and bending, its maximum compressive stress can reach up to 318.96 MPa, the maximum bending strength reached 189.41 MPa, and can meet the mechanical properties of the alloy as a human bone-plate requirements. On the polarization curve, the maximum positive shift of corrosion potential of the specimens was 73 mv and the maximum decrease of corrosion-current density was 53.2%. From the comparison of the above properties, it was concluded that the three prepared alloys of which Mg-20% Zn had the best overall performance. Its maximum compressive stress, maximum bending strength, and corrosion-current density reached 318.96 MPa, 189.41 MPa and 2.08 × 10-5 A·cm-2 respectively, which are more suitable for use as human implant bone splints in human-body fluid environment. The mechanical properties of the sintered Mg-Zn alloys were analyzed using powder-metallurgy techniques, and their microstructure, micromotion wear properties, electrochemical corrosion properties and composition of the physical phases were analyzed and discussed.


Asunto(s)
Implantes Absorbibles , Aleaciones/química , Magnesio/química , Zinc/química , Materiales Biocompatibles/química , Fenómenos Biomecánicos , Interfase Hueso-Implante , Fuerza Compresiva , Corrosión , Pruebas de Dureza , Humanos , Ensayo de Materiales , Metalurgia , Propiedades de Superficie , Difracción de Rayos X
3.
Molecules ; 24(1)2018 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-30591659

RESUMEN

Both numerical simulation and hardness measurements were used to determine the mechanical and microstructural behavior of AZ31 bulk samples when submitted to the Equal Channel Angular Pressing (ECAP) technique. Billets of this representative of Mg-rich alloys were submitted to different numbers of passes for various ECAP modes (anisotropic A, isotropic BC). The strain distribution, the grain size refinement, and the micro-hardness were used as indicators to quantify the effectiveness of the different processing routes. Structural characterizations at different scales were achieved using Scanning Electron Microscopy (SEM), micro-analysis, metallography, Small Angle Neutron Scattering SANS, X-Ray Diffraction (XRD), and texture determination. The grain and crystallite size distribution and orientation as well as defect impacts were determined. Anelastic Spectroscopy (AS) on mechanically deformed samples have shown that the temperature of ECAP differentiate the fragile to ductile regime. MgH2 consolidated powders were checked for using AS to detect potential hydrogen motions and interaction with host metal atoms. After further optimization, the different mechanically-treated samples were submitted to hydrogenation/dehydrogenation (H/D) cycles, which shows that, for a few passes, the BC mode is better than the A one, as supported by theoretical and experimental microstructure analyses. Accordingly, the hydrogen uptake and (H/D) reactions were correlated with the optimized microstructure peculiarities and interpreted in terms of Johnson-Avrami- Mehl-Kolmogorov (JAMK) and Jander models, successively.


Asunto(s)
Aleaciones/química , Simulación por Computador , Hidrógeno/química , Magnesio/química , Ensayo de Materiales/métodos , Análisis Numérico Asistido por Computador , Plásticos/química , Adsorción , Dureza , Cinética , Difracción de Neutrones , Quinolinas/química , Dispersión del Ángulo Pequeño , Análisis Espectral , Estrés Mecánico , Temperatura , Difracción de Rayos X
4.
Eur Arch Otorhinolaryngol ; 273(6): 1455-67, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26341887

RESUMEN

The frontal sinus recess consists of anatomically narrow passages that are prone to stenosis in endonasal frontal sinus surgery for chronic sinus disease. Over the past 100 years, diverse frontal sinus stents have been developed and evaluated in clinical and animal studies. However, superinfection, formation of granulations tissue, stent dislocation and late stenosis of the duct have remained challenges and subject of debate in the literature. Currently developed biodegradable materials, including rare earth-containing magnesium alloys are promising candidates for application as temporary implant materials. The Mg 2 % wt Nd alloy (MgNd2) was used to design a nasal stent that fit the porcine anatomy. In the current study, we evaluate biocompatibility, biodegradation and functionality of a frontal sinus stent in 16 minipigs over 6 months. Intraoperative endoscopy revealed free stent lumen in all cases. Blood examination and clinical examinations indicated no systematic or local inflammation signs. The histopathology and elements analysis showed a very good biocompatibility. The µ-computed tomography-based volumetric analysis showed substantial stent degradation within 6 months. Our MgNd2 based stent appears to be a promising, solid basis for the development of a frontal sinus stent for clinical use.


Asunto(s)
Implantes Absorbibles , Aleaciones , Seno Frontal/cirugía , Magnesio , Stents , Animales , Seno Frontal/diagnóstico por imagen , Modelos Animales , Porcinos , Porcinos Enanos
5.
Materials (Basel) ; 17(9)2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38730869

RESUMEN

This paper presents the methodology of measuring chip temperature in the cutting zone in the rough milling of magnesium alloys. Infrared measurements are taken to determine the effect of variable cutting speed, feed per tooth, and depth of cut on the maximum temperature of chips. Thermal images of chip temperature for a generated collective frame and corresponding histograms are presented. Chip temperatures are presented in numerical terms as median and average values; maximum and minimum values; range; and standard deviation. Box plots are also shown for selected machining conditions. The problems arising during signal recording with a mean emissivity coefficient ε = 0.13, a value which is dedicated during machining magnesium alloys, are discussed in detail. Chip temperatures obtained in the tests do not exceed approx. 420 °C. Therefore, the dry rough milling process carried out with carbide tools with different blade geometries can be considered safe for a wide range of machining parameters. The proposed methodology of chip temperature measurement and result processing is a new and effective approach to safety assessment in the dry milling of magnesium alloys.

6.
Biomed Mater ; 18(3)2023 04 19.
Artículo en Inglés | MEDLINE | ID: mdl-37001532

RESUMEN

Guided bone/tissue regeneration (GBR/GTR) is commonly used in dental treatment. The desired bone/tissue regeneration is achieved by placing a barrier membrane over the defect to avoid the downward growth of faster-growing connective and epithelial tissue into the defect. This review aimed to evaluate osteogenic properties, degradation characteristics, and postoperative complications of eight biodegradable membranes in animal experiments, including non-crosslinked collagen membrane (NCCM), crosslinked collagen membrane (CCM), silk membrane (SM), polylactic-co-glycolic acid, polylactic acid, polyethylene glycol hydrogel, polycaprolactone (PCL), and magnesium alloys. Seven electronic databases (PubMed, Embase, Web of Science, Cochrane Library, Science Direct, Wiley, Scopus and Google Scholar) were screened. Study selection, data extraction and quality assessment were made in duplicate. The SYRCLE assessment tool, CERQual (Confidence in the Evidence from Reviews of Qualitative Research) tool and GRADE tool were used to grade the risk of bias and level of evidence. A total of 2512 articles were found in the electronic database. Finally, 94 articles were selected, of which 53 were meta-analyzed. Surface under the cumulative ranking curve showed the best results for new bone formation in the magnesium barrier membrane group, followed by SM, PCL, NCCM, and CCM. Qualitative analysis showed good biocompatibility for natural polymer membranes and a longer degradation time for synthetic polymer membranes. In addition, 34 studies all showed high bias risks, while other studies had unclear bias risks. Natural polymer membranes were more effective for bone regeneration and magnesium alloys were proved to be promising barrier materials that warrant future research.


Asunto(s)
Regeneración Tisular Dirigida , Magnesio , Animales , Regeneración Ósea , Colágeno , Membranas Artificiales , Metaanálisis en Red , Polímeros
7.
Biomimetics (Basel) ; 8(7)2023 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-37999167

RESUMEN

Magnesium (Mg) alloys are adequate materials for orthopedic and maxilo-facial implants due to their biocompatibility, good mechanical properties closely related to the hard tissues, and processability. Their main drawbacks are the high-speed corrosion process and hydrogen release. In order to improve corrosion and mechanical properties, the Mg matrix can be strengthened through alloying elements with high temperature-dependent solubility materials. Rare earth elements (RE) contribute to mechanical properties and degradation improvement. Another possibility to reduce the corrosion rate of Mg-based alloys was demonstrated to be the different types of coatings (bioceramics, polymers, and composites) applied on their surface. The present investigation is related to the coating of two Mg-based alloys from the system Mg3Nd (Mg-Nd-Y-Zr-Zn) with polymeric-based composite coatings made from cellulose acetate (CA) combined with two fillers, respectively hydroxyapatite (HAp) and Mg particles. The main functions of the coatings are to reduce the biodegradation rate and to modify the surface properties in order to increase osteointegration. Firstly, the microstructural features of the experimental Mg3Nd alloys were revealed by optical microscopy and scanning electron microscopy (SEM) coupled with energy-dispersive spectroscopy. Apart from the surface morphology revealed by SEM, the roughness and wettability of all experimental samples were evaluated. The corrosion behavior of the uncoated and coated samples of both Mg3Nd alloys was investigated by immersion testing and electrochemical testing using Simulated Body Fluid as the medium. The complex in vitro research performed highlights that the composite coating based on CA with HAp particles exhibited the best protective effect for both Mg3Nd alloys.

8.
ACS Biomater Sci Eng ; 9(2): 705-718, 2023 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-36695051

RESUMEN

Suitable biomechanical properties, good biocompatibility, and osteoconductivity of a degradable magnesium (Mg) alloy make it a potential material for orthopedic implants. The main limitation of Mg is its high corrosion rate in the human body. Surface modification is necessary to improve the Mg corrosion resistance. In this work, a polymeric layer of gelatin/nanohydroxyapatite (Gel/nHA) was coated on a ZK60 Mg alloy by dip coating and spin coating to test the corrosion resistance and biocompatibility in vitro and in vivo. The results from the in vitro test revealed that the coated groups reduced the corrosion rate with the corrosion current density by 59 and 81%, from 31.22 to 12.83 µA/cm2 and 5.83 µA/cm2 in the spin coating and dip coating groups, respectively. The dip coating group showed better corrosion resistance than the spin coating group with the lowest released hydrogen content (17.5 mL) and lowest pH value (8.23) and reducing the current density by 45%. In vitro, the relative growth rate was over 75% in all groups tested with MG63, demonstrating that the Mg substrate and coating materials were within the safety range. The dip coating and spin coating groups enhanced the cell proliferation with significantly higher OD values (3.3, 3.0, and 2.5, respectively) and had better antihemolysis and antiplatelet adhesion abilities than the uncoated group. The two coating methods showed no difference in the cellular response, cell migration, hemolysis, and platelet adhesion test. In in vivo tests in rats, the dip coating group also showed a higher corrosion resistance with a lower corrosion rate and mass loss than the spin coating group. In addition, the blood biochemistry and histopathology results indicated that all materials used in this study were biocompatible with living subjects. The present research confirmed that the two methods have no noticeable difference in cell and organ response but the corrosion resistance of dip coating was higher than that of spin coating either in vitro or in vivo.


Asunto(s)
Implantes Absorbibles , Gelatina , Ratas , Humanos , Animales , Gelatina/farmacología , Magnesio/farmacología , Magnesio/química , Propiedades de Superficie , Durapatita/farmacología , Durapatita/química , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/química , Aleaciones/farmacología , Aleaciones/química
9.
Biomed Phys Eng Express ; 8(4)2022 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-35523119

RESUMEN

With changing lifestyles, the demand for bone implantation has been increasing day by day. The deficiency of nutritious elements within the human body results in certain diseases like osteoporosis, rickets, and other skeletal disorders; lack of physical activities; and the increasing number of accidents are the primary reasons for bone damage/fracture. Metallic implants made up of chrome steel, cobalt-based alloys, and titanium-based alloys are being majorly used worldwide owing to their high strength and high corrosion resistance which makes them permanent orthopedic bioimplant materials, however, they display a stress-shielding effect and it also requires an implant removal surgery. Thus, these problems can be addressed through the employment of biodegradable materials. Among the available biodegradable metallic materials, Mg alloys have been identified as a prospective orthopedic implant material. These alloys are biodegradable as well as biocompatible, however, they experience a relatively higher rate of degradation limiting their usability as implant material. This study attempts to comprehensively assess the effects of various alloying elements such as Ca, Zn, Sn, Mn, Sr and Rare earth elements (REEs) on the mechanical and degradation behavior (bothin vivoandin vitro) of Mg alloys. Since the microstructure, mechanical properties and degradation response of the Mg alloys are dependent on the processing route, hence detailed processing- property database of different Mg alloys is provided in this paper.


Asunto(s)
Aleaciones , Magnesio , Aleaciones/química , Aleaciones/farmacología , Materiales Biocompatibles/química , Corrosión , Humanos , Magnesio/química , Estudios Prospectivos
10.
ACS Appl Bio Mater ; 5(5): 2340-2346, 2022 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-35503734

RESUMEN

Magnesium (Mg) alloys as implant materials with excellent biodegradation ability have promising clinical applications for tissue repair and restoration. Although the corrosion processes of Mg alloys in biophysiological media are closely related with their biodegradation ability, only limited methods have been developed for characterization of their corrosion processes, including electrochemical analysis, weight loss measurement, and hydrogen evolution analysis. Moreover, these methods suffer from drawbacks of poor spatiotemporal resolution, static observation, and tedious operation. To tackle these challenges, we herein developed a fluorescent probe PSPA for in situ 3D monitoring of the dynamic corrosion processes of Mg alloys on the basis of its selective turn-on detection ability toward magnesium hydroxide [Mg(OH)2], which is the main corrosion product of Mg alloys in biophysiological media. As far as we know, this is the first example of a fluorescent probe for the monitoring of corrosion processes of Mg alloys in biophysiological media. We believe this fluorescence analysis method with easy operation and high spatiotemporal resolution advantages will contribute greatly to the clinical applications of Mg alloy implants.


Asunto(s)
Aleaciones , Magnesio , Aleaciones/química , Corrosión , Colorantes Fluorescentes , Imagenología Tridimensional , Magnesio/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA