Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
Más filtros

Intervalo de año de publicación
1.
Nano Lett ; 24(5): 1510-1521, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38285667

RESUMEN

α-PD-L1 therapy has shown encouraging results at harnessing the immune system to combat cancer. However, the treatment effect is relatively low due to the dense extracellular matrix (ECM) and tumor immunosuppressive microenvironment (TIME). Therefore, an ultrasound (US)-responsive nanosensitizer (URNS) is engineered to deliver losartan (LST) and polyethylenimine (PEI) to remolde the TME, driving "cold"-"hot" tumor transformation and enhancing the sensitivity of α-PD-L1 therapy. In the tumor site, noninvasive US can make MTNP generate ROS, which cleave ROS-sensitive bonds to dissociate MTNPtK@LST-PEI, shedding PEI and releasing LST from mesoporous spheres. The results demonstrated that URNS combined with α-PD-L1 therapy effectively inhibited tumor growth with an inhibition rate as high as 90%, which was 1.7-fold higher than that of the α-PD-L1 treatment in vivo. In summary, the URNS improves the sensitivity of α-PD-L1 therapy by remodeling the TME, which provides promising insights for optimizing cancer immunotherapy.


Asunto(s)
Antígeno B7-H1 , Neoplasias , Humanos , Especies Reactivas de Oxígeno , Matriz Extracelular , Inmunosupresores , Inmunoterapia , Losartán , Polietileneimina , Microambiente Tumoral
2.
Nano Lett ; 24(31): 9561-9568, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39042325

RESUMEN

The perfect integration of microbubbles for efficient ultrasound imaging and nanocarriers for intelligent tumor-targeting delivery remains a challenge in precise tumor theranostics. Herein, we exquisitely fabricated laser-activated and targeted polymersomes (abbreviated as FIP-NPs) for simultaneously encapsulating the photosensitizer indocyanine green (ICG) and the phase change agent perfluorohexane (PFH). The formulated FIP-NPs were nanosize and effectively accumulated into tumors as observed by ICG fluorescence imaging. When the temperature rose above 56 °C, the encapsulated PFH transformed from liquid to gas and the FIP-NPs underwent balloon-like enlargement without structure destruction. Impressively, the enlarged FIP-NPs fused with adjacent polymersomes to form even larger microparticles. This temperature-responsive "nano-to-micro" transformation and fusion process was clearly demonstrated, and FIP-NPs showed greatly improved ultrasound signals. More importantly, FIP-NPs achieved dramatic antitumor efficacy through ICG-mediated phototherapy. Taken together, the novel polymersomes achieved excellent ultrasound/fluorescence dual imaging-guided tumor phototherapy, providing an optimistic candidate for the application of tumor theranostics.


Asunto(s)
Verde de Indocianina , Imagen Óptica , Fototerapia , Polímeros , Verde de Indocianina/química , Verde de Indocianina/uso terapéutico , Animales , Ratones , Fototerapia/métodos , Humanos , Imagen Óptica/métodos , Polímeros/química , Nanopartículas/química , Nanopartículas/uso terapéutico , Fluorocarburos/química , Neoplasias/diagnóstico por imagen , Neoplasias/terapia , Temperatura , Ultrasonografía/métodos , Línea Celular Tumoral , Fármacos Fotosensibilizantes/química , Fármacos Fotosensibilizantes/uso terapéutico , Nanomedicina Teranóstica/métodos , Microburbujas/uso terapéutico
3.
World J Urol ; 42(1): 252, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38652324

RESUMEN

BACKGROUND: To prevent infectious complications after transrectal ultrasound-guided prostate biopsy (TRUS-PB), some studies have investigated the efficacy of rectal disinfection using povidone-iodine (PI) and antibiotic prophylaxis (AP). OBJECTIVE: To summarize available data and compare the efficacy of rectal disinfection using PI with non-PI methods prior to TRUS-PB. EVIDENCE ACQUISITION: Three databases were queried through November 2023 for randomized controlled trials (RCTs) analyzing patients who underwent TRUS-PB. We compared the effectiveness of rectal disinfection between PI groups and non-PI groups with or without AP. The primary outcomes of interest were the rates of overall infectious complications, fever, and sepsis. Subgroups analyses were conducted to assess the differential outcomes in patients using fluoroquinolone groups compared to those using other antibiotics groups. EVIDENCE SYNTHESIS: We included ten RCTs in the meta-analyses. The overall rates of infectious complications were significantly lower when rectal disinfection with PI was performed (RR 0.56, 95% CI 0.42-0.74, p < 0.001). Compared to AP monotherapy, the combination of AP and PI was associated with significantly lower risk of infectious complications (RR 0.54, 95% CI 0.40-0.73, p < 0.001) and fever (RR 0.47, 95% CI 0.30-0.75, p = 0.001), but not with sepsis (RR 0.49, 95% CI 0.23-1.04, p = 0.06). The use of fluoroquinolone antibiotics was associated with a lower risk of infectious complications and fever compared to non-FQ antibiotics. CONCLUSION: Rectal disinfection with PI significantly reduces the rates of infectious complications and fever in patients undergoing TRUS-PB. However, this approach does not show a significant impact on reducing the rate of sepsis following the procedure.


Asunto(s)
Antiinfecciosos Locales , Biopsia Guiada por Imagen , Povidona Yodada , Próstata , Recto , Humanos , Masculino , Antiinfecciosos Locales/uso terapéutico , Antiinfecciosos Locales/administración & dosificación , Profilaxis Antibiótica/métodos , Desinfección/métodos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Povidona Yodada/uso terapéutico , Povidona Yodada/administración & dosificación , Próstata/patología , Neoplasias de la Próstata/patología
4.
Wound Repair Regen ; 32(4): 419-428, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38602106

RESUMEN

Keloid scars tend to occur in high-tension sites due to mechanical stimuli that are involved in their development. To date, a detailed analysis of keloid distribution focused specifically on facial and neck areas has not been reported, and limited literature exists as to the related mechanical factors. To rectify this deficiency of knowledge, we first quantified the facial and neck keloid distribution observed clinically in 113 patients. Subsequently, we performed a rigorous investigation into the mechanical factors and their associated changes at these anatomic sites in healthy volunteers without a history of pathologic scarring. The association between keloid-predilection sites and sebaceous gland-dense and acne-prone sites was also examined. To assess skin stretch, thickness and stiffness, VECTRA, ultrasound and indentometer were utilised. Baseline skin stiffness and thickness were measured, as well as the magnitude of change in these values associated with facial expression and postural changes. Within the face and neck, keloids were most common near the mandibular angle (41.3%) and lateral submental (20.0%) regions. These areas of increased keloid incidence were not associated with areas more dense in sebaceous glands, nor linked consistently with acne-susceptible regions. Binomial logistic regression revealed that changes in skin stiffness and thickness related to postural changes significantly predicted keloid distribution. Skin stiffness and thickness changes related to prolonged mechanical forces (postural changes) are most pronounced at sites of high keloid predilection. This finding further elucidates the means by which skin stretch and tension are related to keloid development. As a more detailed analysis of mechanical forces on facial and neck skin, this study evaluates the nuances of multiple skin-mechanical properties, and their changes in a three-dimensional framework. Such factors may be critical to better understanding keloid progression and development in the face and neck.


Asunto(s)
Cara , Queloide , Cuello , Piel , Humanos , Queloide/patología , Queloide/fisiopatología , Masculino , Femenino , Cuello/patología , Cara/patología , Adulto , Piel/patología , Persona de Mediana Edad , Movimiento/fisiología , Adulto Joven , Adolescente
5.
Environ Sci Technol ; 58(1): 925-934, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38117535

RESUMEN

Hydrogen peroxide (H2O2), as a critical green chemical, has received immense attention in energy and environmental fields. The ability to produce H2O2 in earth-abundant water without relying on low solubility oxygen would be a sustainable and potentially economic process, applicable even to anaerobic microenvironments, such as groundwater treatment. However, the direct water to H2O2 process is currently hindered by low selectivity and low production rates. Herein, we report that poly(tetrafluoroethylene) (PTFE), a commonly used inert polymer, can act as an efficient triboelectric catalyst for H2O2 generation. For example, a high H2O2 production rate of 24.8 mmol gcat-1 h-1 at a dosage of 0.01 g/L PTFE was achieved under the condition of pure water, ambient atmosphere, and no sacrificial agents, which exceeds the performance of state-of-the-art aqueous H2O2 powder catalysts. Electron spin resonance and isotope experiments provide strong evidence that water-PTFE tribocatalysis can directly oxidize water to produce H2O2 under both anaerobic and aerobic conditions, albeit with different synthetic pathways. This study demonstrates a potential strategy for green and effective tribocatalytic H2O2 production that may be particularly useful toward environmental applications.


Asunto(s)
Peróxido de Hidrógeno , Oxígeno , Polímeros , Agua , Politetrafluoroetileno
6.
J Periodontal Res ; 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39095980

RESUMEN

AIMS: Orthodontic treatment commonly results in orthodontically induced inflammatory root resorption (OIIRR). This condition arises from excessive orthodontic force, which triggerslocal inflammatory responses and impedes cementoblasts' mineralization capacity. Low-intensity pulsed ultrasound (LIPUS) shows potential in reducing OIIRR. However, the precise mechanisms through which LIPUS reduces OIIRR remain unclear. This study aimed to explore the effects and mechanisms of LIPUS on the mineralization of force-treated cementoblasts and its impact on OIIRR. METHODS: We established a rat OIIRR model and locally administered LIPUS stimulation for 7 and 14 days. We analyzed root resorption volume, osteoclast differentiation, and the expression of osteocalcin and yes-associated protein 1 (YAP1) using micro-computed tomography (micro-CT), hematoxylin and eosin, tartrate-resistant acid phosphatase, immunofluorescence and immunohistochemistry staining. In vitro, we applied compressive force and LIPUS to the immortalized mouse cementoblasts (OCCM30). We assessed mineralization using alkaline phosphatase (ALP) staining, alizarin red staining, real-time quantitative polymerase chain reaction, Western blotting and immunofluorescence staining. RESULTS: In rats, LIPUS reduced OIIRR, as evidenced by micro-CT analysis and histological staining. In vitro, LIPUS enhanced mineralization of force-treated OCCM30 cells, as indicated by ALP and alizarin red staining, upregulated mRNA expression of mineralization-related genes, and increased protein expression of mineralization markers. Mechanistically, LIPUS activated YAP1 signaling via the cytoskeleton-Lamin A/C pathway, supported by immunofluorescence and Western blot analysis. CONCLUSION: This study demonstrates that LIPUS promotes mineralization in force-treated cementoblasts and reduces OIIRR by activating YAP1 through the cytoskeletal-Lamin A/C signaling pathway. These findings provide fresh insights into how LIPUS benefits orthodontic treatment and suggest potential strategies for preventing and treating OIIRR.

7.
Environ Res ; 249: 118471, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38354888

RESUMEN

Nowadays, NOR-containing wastewater has placed huge pressure on global ecology. In this study, a chemically-modified chitosan-based polymer was cross-linked with magnetite to prepare a novel magnetic composite adsorbent named Fe3O4/CS-P(AM-SSS) for norfloxacin (NOR) removal. The preparation conditions were optimized by single factor experiments and response surface methodology. A series of characterization analyses were carried out on the morphology, structure, and properties of Fe3O4/CS-P(AM-SSS), verifying that Fe3O4/CS-P(AM-SSS) was successfully prepared. Batch adsorption experiments showed that NOR was efficiently removed by Fe3O4/CS-P(AM-SSS), with a broad pH applicability of 3-10, short adsorption equilibrium time of 60 min, maximum adsorption capacity of 268.79 mg/g, and high regeneration rate of 86% after eight adsorption-desorption cycles. Due to the three-dimensional network structure and abundant functional groups provided by modified chitosan polymer, the superior adsorption capability of Fe3O4/CS-P(AM-SSS) was achieved through electrostatic interaction, π-π stacking, hydrophobic interaction, and hydrogen bonding. Adsorption process was exothermic and well fitted by the pseudo-second-order kinetic model and the Langmuir isothermal model. The presence of cations had a slight inhibitory effect on NOR adsorption, while humic acid nearly had no effect. In model swine wastewater, 90.3% NOR was removed by Fe3O4/CS-P(AM-SSS). Therefore, with these superior characteristics, Fe3O4/CS-P(AM-SSS) was expected to be an ideal material for treating NOR-containing wastewater in the future.


Asunto(s)
Quitosano , Óxido Ferrosoférrico , Norfloxacino , Contaminantes Químicos del Agua , Norfloxacino/química , Adsorción , Contaminantes Químicos del Agua/química , Contaminantes Químicos del Agua/análisis , Concentración de Iones de Hidrógeno , Óxido Ferrosoférrico/química , Quitosano/química , Antibacterianos/química , Aguas Residuales/química , Polímeros/química , Cinética
8.
J Clin Periodontol ; 51(7): 915-925, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38508585

RESUMEN

AIM: To evaluate the suitability of a Doppler ultrasound probe in detecting the greater palatine artery or its greater branches non-invasively. MATERIALS AND METHODS: The palatal mucosa of 108 participants (median age 34 years, 51 female) was systematically divided into transversal sectors, each aligning with the positions of the upper molars (M), premolars (P) and canine teeth (C), aiming to facilitate precise and consistent localization of the detected palatal blood vessel across different patients. Blood flow of the palatal blood vessels, presumably, was located by scanning the palatal vault bilaterally using an 8-MHz ultrasound probe linked to a transducer. The distance to the corresponding tooth was measured using a millimetre-scale periodontal probe. RESULTS: Within the regions of M2 to P1, the ultrasound transducer gave a delimitable acoustic pulse signal in 80%-98% of all measurements. The measured median distances between the determined position of the artery and the corresponding teeth ranged from 13 to 15 mm, with smaller distances in the anterior region. In several sectors, the distance was significantly higher for men (C: p = .048; P1: p = .041, M1: p < .01; M2: p = .034). CONCLUSIONS: Use of the Doppler ultrasound transducer might be a promising approach to non-invasively detect relevant palatine blood vessels preoperatively. It, therefore, might have the potential to reduce the risk of accidental injury during palatal surgery.


Asunto(s)
Hueso Paladar , Ultrasonografía Doppler , Humanos , Estudios Transversales , Masculino , Femenino , Adulto , Ultrasonografía Doppler/métodos , Hueso Paladar/irrigación sanguínea , Hueso Paladar/diagnóstico por imagen , Persona de Mediana Edad , Prueba de Estudio Conceptual , Adulto Joven
9.
BMC Vet Res ; 20(1): 74, 2024 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-38402395

RESUMEN

BACKGROUND: Regional anesthesia is the favored choice in ruminant animals compared to general anesthesia, primarily due to its high safety margin and reduced demand for cost-intensive equipment in addition to its field applicability. Ultrasound-guided nerve block has gained significant attention in the field of veterinary medicine. This study utilized twenty-seven sheep of the native Rahmani breed to both demonstrate and evaluate the effectiveness of the ultrasound guided inferior alveolar nerve block technique. METHODS: The research comprised three phases: Phase 1 involved an anatomical examination of mandibles and sheep heads to locate the mandibular foramen and delineate the mandibular nerve course. Phase 2 included ultrasound-guided injection of methylene blue dye at specific sites along the mandibular nerve in cadaveric sheep heads. In Phase 3, clinical implementation of ultrasound-guided inferior alveolar nerve blocks was conducted in 27 live sheep, assessing efficacy, onset, and duration. RESULTS: Vertical extraoral ultrasound-guided nerve block was achieved successfully in 25 sheep (98%). A preliminary cadaveric study showed good distribution of the injectate at the mandibular nerve site. The mean onset time was 138 ± 18 s, and the mean duration time was 54 ± 4.1 min. Prominent analgesia of the ipsilateral mandible, medial surface of the cheek, and lateral border of the tongue was observed. CONCLUSIONS: Ultrasound-guided mandibular nerve block holds promise as a technique for providing effective and safe anesthesia in sheep undergoing mandibular procedures.


Asunto(s)
Bloqueo Nervioso , Enfermedades de las Ovejas , Animales , Cadáver , Nervio Mandibular , Bloqueo Nervioso/veterinaria , Ovinos/cirugía , Ultrasonografía , Ultrasonografía Intervencional/veterinaria
10.
BMC Pregnancy Childbirth ; 24(1): 526, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39134961

RESUMEN

BACKGROUND: Orofacial clefts are one of the most common congenital malformations of the fetal face and ultrasound is mainly responsible for its diagnosis. It is difficult to view the fetal palate, so there is currently no unified standard for fetal palate screening, and the diagnosis of cleft palate is not included in the relevant prenatal ultrasound screening guidelines. Many prenatal diagnoses for cleft palate are missed due to the lack of effective screening methods. Therefore, it is imperative to increase the display rate of the fetal palate, which would improve the detection rate and diagnostic accuracy for cleft palate. We aim to introduce a fetal palate screening software based on the "sequential sector scan though the oral fissure", an effective method for fetal palate screening which was verified by our follow up results and three-dimensional ultrasound and to evaluate its feasibility and clinical practicability. METHODS: A software was designed and programmed based on "sequential sector scan through the oral fissure" and three-dimensional ultrasound. The three-dimensional ultrasound volume data of the fetal face were imported into the software. Then, the median sagittal plane was taken as the reference interface, the anterior upper margin of the mandibular alveolar bone was selected as the fulcrum, the interval angles, and the number of layers of the sector scan were set, after which the automatic scan was performed. Thus, the sector scan sequential planes of the mandibular alveolar bone, pharynx, soft palate, hard palate, and maxillary alveolar bone were obtained in sequence to display and evaluate the palate. In addition, the feasibility and accuracy of the software in fetal palate displaying and screening was evaluated by actual clinical cases. RESULTS: Full views of the normal fetal palates and the defective parts of the cleft palates were displayed, and relatively clear sequential tomographic images and continuous dynamic videos were formed after the three-dimensional volume data of 10 normal fetal palates and 10 cleft palates were imported into the software. CONCLUSIONS: The software can display fetal palates more directly which might allow for a new method of fetal palate screening and cleft palate diagnosis.


Asunto(s)
Fisura del Paladar , Imagenología Tridimensional , Programas Informáticos , Ultrasonografía Prenatal , Humanos , Ultrasonografía Prenatal/métodos , Fisura del Paladar/diagnóstico por imagen , Fisura del Paladar/embriología , Imagenología Tridimensional/métodos , Embarazo , Femenino , Hueso Paladar/diagnóstico por imagen , Hueso Paladar/embriología , Adulto , Estudios de Factibilidad
11.
J Nanobiotechnology ; 22(1): 2, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38169390

RESUMEN

BACKGROUND: Off-targeted distribution of chemotherapeutic drugs causes severe side effects, further leading to poor prognosis and patient compliance. Ligand/receptor-mediated targeted drug delivery can improve drug accumulation in the tumor but it always attenuated by protein corona barriers. RESULTS: To address these problems, a radically different strategy is proposed that can leave the off-targeted drugs inactive but activate the tumor-distributed drugs for cancer-targeting therapy in a tumor microenvironment-independent manner. The feasibility and effectiveness of this strategy is demonstrated by developing an ultrasound (US)-activated prodrug-loaded liposome (CPBSN38L) comprising the sonosensitizer chlorin e6 (Ce6)-modified lipids and the prodrug of pinacol boronic ester-conjugated SN38 (PBSN38). Once CPBSN38L is accumulated in the tumor and internalized into the cancer cells, under US irradiation, the sonosensitizer Ce6 rapidly induces extensive production of intracellular reactive oxygen species (ROS), thereby initiating a cascade amplified ROS-responsive activation of PBSN38 to release the active SN38 for inducing cell apoptosis. If some of the injected CPBSN38L is distributed into normal tissues, the inactive PBSN38 exerts no pharmacological activity on normal cells. CPBSN38L exhibited strong anticancer activity in multiple murine tumor models of colon adenocarcinoma and hepatocellular carcinoma with no chemotherapy-induced side effects, compared with the standard first-line anticancer drugs irinotecan and topotecan. CONCLUSIONS: This study established a side-effect-evitable, universal, and feasible strategy for cancer-targeting therapy.


Asunto(s)
Adenocarcinoma , Antineoplásicos , Neoplasias del Colon , Nanopartículas , Fotoquimioterapia , Profármacos , Humanos , Animales , Ratones , Liposomas , Profármacos/farmacología , Profármacos/uso terapéutico , Especies Reactivas de Oxígeno/metabolismo , Adenocarcinoma/tratamiento farmacológico , Neoplasias del Colon/diagnóstico por imagen , Neoplasias del Colon/tratamiento farmacológico , Antineoplásicos/uso terapéutico , Línea Celular Tumoral , Nanopartículas/metabolismo , Fármacos Fotosensibilizantes/uso terapéutico , Microambiente Tumoral
12.
Heart Vessels ; 39(6): 496-504, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38411631

RESUMEN

Limited data exist regarding drug-coated balloon (DCB) treatment in de novo large coronary arteries. We sought to demonstrate procedural characteristics, residual stenosis, and clinical outcomes following DCB angioplasty for de novo lesions in large versus small coronary arteries. The study included 184 consecutive patients with 223 de novo coronary lesions undergoing paclitaxel DCB angioplasty between January 2019 and August 2020, who were divided according to whether the DCB diameter was ≥ 3.0 mm (large group, n = 58) or < 3.0 mm (small group, n = 125). The large group had a higher proportion of acute coronary syndrome more commonly with ostial, bifurcation, and calcified lesions in large vessels and received lesion preparation with more frequent use of scoring or cutting balloons and atherectomy devices compared to the small group. Postprocedural angiographic diameter stenosis was smaller in the large group compared to the small group (31% [22-37] vs. 35% [26-42], p = 0.032), and intravascular ultrasound revealed no significant difference in postprocedural area stenosis between the groups (66.2 ± 7.7% vs. 67.9 ± 7.8%; p = 0.26). The median follow-up duration was 995 days. The incidence of a composite of all-cause death, myocardial infarction, stroke, or target lesion revascularization was similar between the groups (log-rank p = 0.41) and was influenced by the presence of acute coronary syndrome and anemia but not by DCB diameter. The rate of cardiovascular outcomes after DCB treatment was comparable in de novo large and small coronary arteries. Notably, well-planned lesion preparation with intravascular imaging guidance was prevalent in large vessels.


Asunto(s)
Angioplastia Coronaria con Balón , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Humanos , Masculino , Femenino , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Angioplastia Coronaria con Balón/instrumentación , Anciano , Vasos Coronarios/diagnóstico por imagen , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico , Estudios Retrospectivos , Persona de Mediana Edad , Paclitaxel/administración & dosificación , Estudios de Seguimiento
13.
BMC Med Imaging ; 24(1): 10, 2024 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172706

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) provide accurate vascular imaging information, but their use may be contraindicated. Color Doppler ultrasonography (CDU) provides simple, safe, noninvasive, and reproducible imaging. We therefore investigated the role of preoperative CDU combined with CTA and MRA in the quantification, typing, and diagnosis of carotid body tumors (CBTs). METHODS: We retrospectively analyzed patients with CBTs categorized into group A (type I [n = 1] and type II [n = 10]) or group B (type III [n = 56]) per the intraoperative Shamblin classification. CDU, CTA, and MRA characteristics of CBTs were observed, surgical results were correlated, and the diagnostic threshold of the CBT classification was calculated. RESULTS: CBTs were usually located at the common carotid artery bifurcation, encircling the carotid artery. An increased angle was found between the internal and external carotid arteries. On CDU, CBTs primarily presented as homogeneous hypoechoic masses with clear boundaries, rich flow signals, and a high-speed, low-resistance artery-like flow spectrum. CTA showed uniform or heterogeneous marked enhancement. MRA showed mixed T1 and slightly longer T2 signals and uniform or uneven obvious enhancement. With increases in the lesion size, amount of blood transfused, and operation time, the intraoperative classification level and possibility of skull-base invasion increased. When the maximum diameter of the lesion, the volume of the tumor, the distance between the upper margin of the tumor to the mastoid and the mandibular angle were 3.10 cm, 10.15 cm3, - 3.26 cm, and 0.57 cm, respectively, the largest Youden index was the best diagnostic boundary value for Shamblin type III tumors. CONCLUSIONS: CDU combined with CTA and MRA can accurately evaluate the size and classification of CBTs.


Asunto(s)
Tumor del Cuerpo Carotídeo , Angiografía por Tomografía Computarizada , Humanos , Angiografía por Tomografía Computarizada/métodos , Angiografía por Resonancia Magnética , Estudios Retrospectivos , Tumor del Cuerpo Carotídeo/patología , Tumor del Cuerpo Carotídeo/cirugía , Ultrasonografía Doppler en Color/métodos
14.
Oral Dis ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38968162

RESUMEN

OBJECTIVE: This study aimed to investigate the clinical and laboratory characteristics of salivary gland ultrasonography (SGUS)-positive patients with primary Sjögren's syndrome (pSS) compared to SGUS-negative patients and to analyse the diagnostic value of SGUS and labial salivary gland biopsy (LSGB) grading in pSS. METHODS: A retrospective analysis of patients admitted to the Affiliated Hospital of Yangzhou University between May 2019 and November 2023 was conducted. According to the OMERACT scoring system, patients with pSS were divided into an SGUS-negative group (score <2) and an SGUS-positive group (score ≥2). The patient's age, gender, clinical symptoms, laboratory parameters and diagnostic examinations were compared and analysed, and Spearman correlation analysis was used to analyse the correlation between SGUS, LSGB and influencing factors. RESULTS: There was no significant difference in dry mouth, dry eyes, tooth loss, fever, joint pain, fatigue, interstitial lung disease or renal tubular acidosis between the two groups, although there were more patients with salivary gland enlargement in the SGUS-positive group (p < 0.05). In terms of high levels of immunoglobulin G (IgG), high levels of rheumatoid factor (RF), anti-nuclear antibody ≥1:320, anti-Sjögren's syndrome A-52KD and anti-Sjögren's syndrome B, the number of cases in the SGUS-positive group was greater than that in the SGUS-negative group (p < 0.05). LSGB samples were graded per the Chisholm-Mason system with significant differences between multiple groups. SGUS score negatively correlated with age and positively correlated with LSGB grade. CONCLUSION: This study showed that the SGUS score positively correlated with LSGB grade in pSS patients and negatively correlated with patient age. Thus, SGUS and LSGB are consistent in the diagnosis of pSS to reflect the degree of salivary gland involvement, and patients who are SGUS positive have high RF and IgG levels, a variety of autoantibodies positive and a tendency toward salivary gland enlargement.

15.
BMC Anesthesiol ; 24(1): 237, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39009966

RESUMEN

BACKGROUND: Failure to adhere to perioperative fasting requirements increases aspiration risk and can lead to delay or cancellation of surgery. Point of care gastric ultrasound may guide decision-making to delay, cancel or proceed with surgery. METHODS: This study aimed to describe gastric contents using point of care gastric ultrasound in pediatric patients with known fasting guideline violations presenting for elective surgery. This was a single-center retrospectivechart review of gastric ultrasound scans in patients presenting for elective surgeries with "nothing by mouth" violation (per fasting guidelines) or unclear fasting status. The primary outcome is description of gastric contents using point of care ultrasound. The ultrasound findings were classified as low-risk for aspiration (empty, clear fluid < 1.5 ml/kg), high-risk (solids, clear fluid > 1.5 ml/kg), or inconclusive study. Gastric ultrasound findings were communicated to the attending anesthesiologist. For patients proceeding without delay the estimated time saved was defined as the difference between ultrasound scan time and presumed case start time based on American Society of Anesthesiologists fasting guidelines. RESULTS: We identified 106 patients with a median age of 4.8 years. There were 31 patients (29.2%) that had ultrasound finding of high-risk gastric contents. These patients had cases that were delayed, cancelled or proceeded with rapid sequence intubation. Sixty-six patients (62.3%) were determined to be low-risk gastric contents and proceeded with surgery without delay. For these patients, a median of 2.6 h was saved. No aspiration events were recorded for any patients. CONCLUSIONS: It is feasible to use preoperative point of care gastric ultrasound to determine stomach contents and risk-stratify pediatric patients presenting for elective surgical procedures with fasting non-adherence. Preoperative gastric ultrasound may have a role in determining changes in anesthetic management in this patient population.


Asunto(s)
Procedimientos Quirúrgicos Electivos , Ayuno , Contenido Digestivo , Sistemas de Atención de Punto , Cuidados Preoperatorios , Estómago , Ultrasonografía , Humanos , Estudios Retrospectivos , Procedimientos Quirúrgicos Electivos/métodos , Femenino , Masculino , Preescolar , Ultrasonografía/métodos , Niño , Cuidados Preoperatorios/métodos , Contenido Digestivo/diagnóstico por imagen , Estómago/diagnóstico por imagen , Anestesia/métodos , Lactante , Adolescente
16.
Can J Urol ; 31(2): 11854-11857, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38642464

RESUMEN

The majority of solid testicular tumors are treated with orchiectomy given the high risk of malignancy. We present a case of a testicular mass in an adult patient in the setting of recent hand, foot, and mouth disease that was managed conservatively with serial ultrasounds. Even though cases of viral-associated testicular masses are rare, this differential diagnosis should be considered in patients with a new testicular mass in the setting of recent viral infection and negative tumor markers. For these patients, observation may be an option instead of immediate orchiectomy.


Asunto(s)
Enfermedad de Boca, Mano y Pie , Neoplasias Testiculares , Masculino , Adulto , Humanos , Enfermedad de Boca, Mano y Pie/patología , Testículo , Neoplasias Testiculares/diagnóstico , Neoplasias Testiculares/cirugía , Neoplasias Testiculares/patología , Orquiectomía , Ultrasonografía
17.
Orthod Craniofac Res ; 2024 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-39127913

RESUMEN

Accelerating orthodontic tooth movement (OTM) is increasingly important for shorter treatment times, which reduces periodontal risks, root resorption and dental caries. Techniques to accelerate OTM focus on stimulating bone remodelling by enhancing osteoclast and osteoblast activity and include both surgical and non-surgical methods. The therapeutic potential of ultrasounds is highly recognized among many medical areas and has shown promising results in modulating bone remodelling and inflammation phenomena. This systematic review aims to collect and analyse the current scientific in vitro and ex vivo evidence on ultrasound stimulation (US) bioeffects in cells implicated in tooth movement. This review was conducted according to PRISMA 2020 guidelines. A bibliographic search was carried out in the PubMed, Scopus and Web of Science databases. Sixteen articles were selected and included in this review. The revised studies suggest that US of 1.0 and 1.5 MHz, delivered at 30 mW/cm2, 10 to 30 min daily over three to 14 days seems to be effective in promoting osteoclastogenic activity, while US of 1.5 MHz, 30 to 90 mW/cm2, in 5- to 20-min sessions delivered daily for 5 to 14 days exhibits the potential to stimulate osteogenic activity and differentiation. Previous research yielded varied evidence of the effectiveness of US in orthodontics. Future animal studies should employ the recommended US parameters and investigate how distinct protocols can differentially impact tissue remodelling pathways. The knowledge arising from this review will ultimately potentiate the application of US to accelerate OTM in the clinical setting.

18.
J Ultrasound Med ; 43(8): 1489-1499, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38708914

RESUMEN

OBJECTIVES: To investigate the role of high-resolution ultrasound (HR-US) in the initial and differential diagnosis of the Odontogenic Cutaneous Sinus Tract (OCST) in a multicentric setting. METHODS: Skin HR-US examinations of OCSTs performed between January 2019 and June 2023 at different Institutions were retrospectively reviewed. Epidemiological and clinical data (age, gender, location of the skin lesion, causative tooth, and the clinical suspicion) as well as HR-US imaging findings (morphology and length of the sinus tract, Doppler signal, and cortical bone interruption of maxilla or mandible) were collected. US examinations were performed by expert radiologists using a high-performance US scanner, employing a high-frequency linear probe (15 MHz or higher frequencies). In only one patient the HR-US exam was integrated with strain elastography (SE). RESULTS: Sixteen patients were enrolled with a median age of 37.6 years (range 16-70 years). The most frequent clinical suspicion was epidermal cyst, while OCST was suspected in only two cases. In all cases, HR-US depicted the sinus tract as a nodular, triangular or "champignon-shaped" lesion in the subcutaneous layer, which continued with a slightly tortuous band structure, up to the focally interrupted cortical bone plate. Furthermore, color Doppler evaluation showed color signals around and/or within the lesion, expression of inflammation. On SE, the sinus tract showed a hard pattern, due to fibrous and granulomatous tissue. CONCLUSIONS: HR-US, thanks to its high spatial resolution, allows the evaluation of OCST, and play a crucial diagnostic role, mainly when the clinical suspicious is different.


Asunto(s)
Ultrasonografía , Humanos , Masculino , Femenino , Adolescente , Persona de Mediana Edad , Adulto , Estudios Retrospectivos , Adulto Joven , Anciano , Ultrasonografía/métodos , Diagnóstico Diferencial , Quistes Odontogénicos/diagnóstico por imagen , Fístula Cutánea/diagnóstico por imagen
19.
Am J Otolaryngol ; 45(4): 104259, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38547749

RESUMEN

OBJECTIVE: To assess the influence of varying retention doses of ultrasound-guided polidocanol chemical ablation for benign cystic-solid thyroid nodules. METHODS: A retrospective study was conducted from December 2019 to January 2022, including 78 patients with benign cystic-solid thyroid nodules, of which 31 received polidocanol chemical ablation alone, 23 received polidocanol chemical plus thermal ablation, and 24 received open surgery. Patients who received polidocanol chemical ablation were assigned into groups based on the retention dose of polidocanol: 0 %, 10 %, 20 %, 30 %, and 50 %. Follow-ups were done at 1, 3, 6, and 12 months postoperatively. The volume of the nodules, postoperative complications, and recurrence of the nodules were examined before treatment and during follow-up visits. RESULTS: Total operation time and intraoperative bleeding volume for patients who received ablation were substantially lower than those for patients who received open surgery (P < 0.001). Among patients in the polidocanol chemical ablation group, volume shrinkage rate of thyroid nodules in the 10 % retention dose group was significantly lower than that in the 0 % retention dose group at 1, 3, and 6 months postoperatively (P < 0.05). The 30 % retention dose group had the highest nodule shrinkage rate (98.46 ± 1.55 %) at 12 months postoperatively, which was significantly higher than that in the 50 % retention dose group (P < 0.05). Among patients in the polidocanol chemical and thermal ablation group, the volume shrinkage rate of thyroid nodules in the 10 % and 30 % retention dose groups at 1 month postoperatively was significantly lower than that in the 0 % retention dose group (P < 0.05). Although volume shrinkage rate in the 20 % retention dose group after thermal ablation was higher than that in the 0 % retention dose group, the difference was not statistically significant (P > 0.05). In terms of adverse reactions, the incidence of hoarseness and coughing was higher in the open surgery group than in the polidocanol chemical ablation and polidocanol chemical and thermal ablation groups, but there was no significant difference (P > 0.05). CONCLUSION: Chemical ablation with polidocanol was safe and effective for therapy of benign cystic-solid thyroid nodules, and the optimal retention dose may be between 20 % and 30 %. Patients with poor efficacy from chemical ablation alone can receive safe and effective treatment through thermal ablation.


Asunto(s)
Polidocanol , Soluciones Esclerosantes , Nódulo Tiroideo , Ultrasonografía Intervencional , Humanos , Polidocanol/administración & dosificación , Femenino , Masculino , Estudios Retrospectivos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/cirugía , Nódulo Tiroideo/patología , Persona de Mediana Edad , Adulto , Resultado del Tratamiento , Soluciones Esclerosantes/administración & dosificación , Técnicas de Ablación/métodos , Anciano
20.
Clin Oral Investig ; 28(3): 164, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38383689

RESUMEN

OBJECTIVE: Ultrasound is a non-invasive and low-cost diagnostic tool widely used in medicine. Recent studies have demonstrated that ultrasound imaging might have the potential to be used intraorally to assess the periodontium by comparing it to current imaging methods. This study aims to characterize the repeatability of intraoral periodontal ultrasound imaging. MATERIALS AND METHODS: Two hundred and twenty-three teeth were scanned from fourteen volunteers participating in this study. One operator conducted all the scans in each tooth thrice with a 20 MHz intraoral ultrasound. The repeatability of three measurements, alveolar bone crest to the cementoenamel junction (ABC-CEJ), gingival thickness (GT), and alveolar bone thickness (ABT), was calculated with intercorrelation coefficient (ICC). Measurements were also compared with mean absolute deviation (MAD), repeatability coefficient (RC), and descriptive statistics. RESULTS: ICC scores for intra-rater repeatability were 0.917(0.897,0.933), 0.849(0.816,0.878), and 0.790(0.746,0.898), MAD results were 0.610 mm (± 0.508), 0.224 (± 0.200), and 0.067 (± 0.060), and RC results were 0.648, 0.327, and 0.121 for ABC-CEJ, GT, and ABT measurements, respectively. CONCLUSION: Results of the present study pointed towards good or excellent repeatability of ultrasound as a measurement tool for periodontal structures. CLINICAL RELEVANCE: Clinicians could benefit from the introduction of a novel chairside diagnostic tool. Ultrasound is a non-invasive imaging assessment tool for the periodontium with promising results in the literature. Further validation, establishment of scanning protocols, and commercialization are still needed before ultrasound imaging is available for clinicians.


Asunto(s)
Diente , Humanos , Diente/diagnóstico por imagen , Encía , Periodoncio/diagnóstico por imagen , Ultrasonografía , Proceso Alveolar/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA