1.
J Appl Clin Med Phys ; 23(8): e13728, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35861648

RESUMEN

PURPOSE: The purpose of this work is to evaluate the Standard Imaging Exradin W2 plastic scintillation detector (W2) for use in the types of fields used for stereotactic radiosurgery. METHODS: Prior to testing the W2 in small fields, the W2 was evaluated in standard large field conditions to ensure good detector performance. These tests included energy dependence, short-term repeatability, dose-response linearity, angular dependence, temperature dependence, and dose rate dependence. Next, scan settings and calibration of the W2 were optimized to ensure high quality data acquisition. Profiles of small fields shaped by cones and multi-leaf collimator (MLCs) were measured using the W2 and IBA RAZOR diode in a scanning water tank. Output factors for cones (4-17.5 mm) and MLC fields (1, 2, 3 cm) were acquired with both detectors. Finally, the dose at isocenter for seven radiosurgery plans was measured with the W2 detector. RESULTS: W2 exhibited acceptable warm-up behavior, short-term reproducibility, axial angular dependence, dose-rate linearity, and dose linearity. The detector exhibits a dependence upon energy, polar angle, and temperature. Scanning measurements taken with the W2 and RAZOR were in good agreement, with full-width half-maximum and penumbra widths agreeing to within 0.1 mm. The output factors measured by the W2 and RAZOR exhibited a maximum difference of 1.8%. For the seven point-dose measurements of radiosurgery plans, the W2 agreed well with our treatment planning system with a maximum deviation of 2.2%. The Cerenkov light ratio calibration method did not significantly impact the measurement of relative profiles, output factors, or point dose measurements. CONCLUSION: The W2 demonstrated dosimetric characteristics that are suitable for radiosurgery field measurements. The detector agreed well with the RAZOR diode for output factors and scanned profiles and showed good agreement with the treatment planning system in measurements of clinical treatment plans.


Asunto(s)
Plásticos , Radiocirugia , Calibración , Humanos , Radiometría/métodos , Radiocirugia/métodos , Reproducibilidad de los Resultados
2.
J Appl Clin Med Phys ; 23(5): e13576, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35322526

RESUMEN

INTRODUCTION: Two end-to-end tests evaluate the accuracy of a surface-guided radiation therapy (SGRT) system (CRAD Catalyst HD) for position verification in comparison to a stereoscopic x-ray imaging system (Brainlab Exactrac ) for single-isocenter, multiple metastases stereotactic radiosurgery (SRS) using 3D polymer gel inserts. MATERIALS AND METHODS: A 3D-printed phantom (Prime phantom, RTsafe PC, Athens, Greece) with two separate cylindrical polymer gel inserts were immobilized in open-face masks and treated with a single isocentric, multitarget SRS plan. Planning was done in Brainlab (Elements) to treat five metastatic lesions in one fraction, and initial setup was done using cone beam computed tomography. Positional verification was done using orthogonal X-ray imaging (Brainlab Exactrac) and/or a surface imaging system (CRAD Catalyst HD, Uppsala, Sweden), and shift discrepancies were recorded for each couch angle. Forty-two hours after irradiation, the gel phantom was scanned in a 1.5 Tesla MRI, and images were fused with the patient computed tomography data/structure set for further analysis of spatial dose distribution. RESULTS: Discrepancies between the CRAD Catalyst HD system and Brainlab Exactrac were <1 mm in the translational direction and <0.5° in the angular direction at noncoplanar couch angles. Dose parameters (DMean% , D95% ) and 3D gamma index passing rates were evaluated for both setup modalities for each planned target volume (PTV) at a variety of thresholds: 3%/2 mm (Exactrac≥93.1% and CRAD ≥87.2%), 5%/2 mm (Exactrac≥95.6% and CRAD ≥94.6%), and 5%/1 mm (Exactrac≥81.8% and CRAD ≥83.7%). CONCLUSION: Dose metrics for a setup with surface imaging was found to be consistent with setup using x-ray imaging, demonstrating high accuracy and reproducibility for treatment delivery. Results indicate the feasibility of using surface imaging for position verification at noncoplanar couch angles for single-isocenter, multiple-target SRS using end-to-end quality assurance (QA) testing with 3D polymer gel dosimetry.


Asunto(s)
Radiocirugia , Humanos , Fantasmas de Imagen , Polímeros , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Rayos X
3.
J Appl Clin Med Phys ; 22(9): 171-182, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34288376

RESUMEN

PURPOSE: Island blocking occurs in single-isocenter multiple-target (SIMT) stereotactic radiotherapy (SRS) whenever targets share multi-leaf collimator (MLC) leaf pairs. This study investigated the effect on plan quality and delivery, of reducing island blocking through collimator angle optimization (CAO). In addition, the effect of jaw tracking in this context was also investigated. METHODS: For CAO, an algorithm was created that selects the collimator angle resulting in the lowest level of island blocking, for each beam in any given plan. Then, four volume-modulated arc therapy (VMAT) SIMT SRS plans each were generated for 10 retrospective patients: two CAO plans, with and without jaw tracking, and two plans with manually selected collimator angles, with and without jaw tracking. Plans were then assessed and compared using typical quality assurance procedures. RESULTS: There were no substantial differences between plans with and without CAO. Jaw tracking produced statistically significant reduction in low-dose level parameters; healthy brain V10% and mean dose were reduced by 9.66% and 15.58%, respectively. However, quantitative values (108 cc for V10% and 0.35 Gy for mean dose) were relatively small in relation to clinical relevance. Though there were no statistically significant changes in plan deliverability, there was a notable trend of plans with jaw tracking having lower gamma analysis pass rates. CONCLUSION: These findings suggest that CAO has limited benefit in VMAT SIMT SRS of 2-6 targets when using a low-dose penalty to the healthy brain during plan optimization in Eclipse. As clinical benefits of jaw tracking were found to be minimal and plan deliverability was potentially reduced, a cautious approach would be to exclude jaw tracking in SIMT SRS plans.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
4.
Childs Nerv Syst ; 34(11): 2269-2274, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29882061

RESUMEN

PURPOSE: Treatment of cerebral arteriovenous malformations (AVM)-the most common cause of stroke in the pediatric population-can be challenging due to the complexity of size, morphology, and location. There is a significant risk in comparison to AVM treatment among adults. Thus, AVM treatment in the pediatric population imposes unique challenges. Recent improvements include optimized catheter techniques and better embolization materials, such as Onyx, a non-adhesive liquid embolic agent used in the adult population. These improvements have increased the success rate of total and near-total obliteration of cerebral AVM. However, the use of Onyx causes significant distortion of the MR and CT images, which must be accounted for in any radiation treatment planning predicated on CT and MRI. These image distortions impact on the actual delivered dose to the nidus and behoove heterogeneity correction. Our group has previously shared a solution for heterogeneity correction in the adult population. The purpose of this study is to show our experience in this unique group of pediatric patients. METHODS: This is a retrospective review of pediatric patients, who were undergoing combined endovascular embolization followed by SRS. The cohort consists of 14 patients undergoing SRS treatment in our institute between November 2006 and December 2012 with a mean follow-up of 49.9 months. Within this cohort, we retrospectively reviewed 12 consecutive pediatric patients who underwent a combined endovascular and SRS approach with a mean follow-up of 52.1 months and two patients receiving SRS-only treatment were excluded. RESULTS: In our cohort of 14 patients, 7 (50%) were male, with a mean age of 17.3 years (12.0-22.9) at the time of radiosurgery treatment. Mean age of beginning the combined modality treatment was 15.3 years (8.4-20). The median time from diagnosis to SRS was 24.3 months (11.1-64.4 months) in the complete cohort and 25.6 months (11.1-64.4) in the multimodality group. The overall median follow-up period was 49.9 months (range 12.8-118.8 months) in the complete cohort and 52.1 months (range 12.8-118.8 months) in the multimodality group. Eleven (78.6%) patients had at least one episode of hemorrhage prior to treatment. Spezler-Martin grades at baseline ranged from 2 to 5 (mean 3.2). Fifty percent had grade IV and V. Patients underwent a median of 2 (range 1-5) embolization procedures. The radiosurgical treatment dose to the margin of the angiography-based nidus: median prescription dose of 21.49 Gy (14.39-27.51) with a median max dose of 27.77 Gy (18.93-32.52). The median treatment volume was 0.6 cm3 (0.1-7.3 cm3). The Onyx embolization reduced the nidus target volume by a median of 66.7% (12.0-92.7%). We confirmed 10/14 (71%) complete closures. In 2/14 (14.2%) additional patients, a significant flow reduction was noted. In 1/14 (7.1%) patients, no significant change was noted during the observation period and two (14.2%) patients were without follow-up information. In two patients, post-treatment edema was noted; however, none was clinically significant and resolved without additional intervention or treatment. CONCLUSIONS: This cohort comprises the largest combined Onyx-SRS pediatric experience in the literature. In conjunction with our adult group study, we show that the use of Onyx reduces the SRS treatment target volume significantly. Importantly, we implemented the heterogeneity correction to avoid increased radiation exposure to normal surrounding brain tissue. The combined approach appears to be safe provided that the above-mentioned corrections are implemented.


Asunto(s)
Terapia Combinada/métodos , Embolización Terapéutica/métodos , Malformaciones Arteriovenosas Intracraneales/terapia , Radiocirugia/métodos , Adolescente , Niño , Estudios de Cohortes , Dimetilsulfóxido/uso terapéutico , Femenino , Humanos , Masculino , Polivinilos/uso terapéutico , Estudios Retrospectivos , Adulto Joven
5.
Phys Med Biol ; 69(15)2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38959910

RESUMEN

Objective.To develop and benchmark a novel 3D dose verification technique consisting of polymer gel dosimetry (PGD) with cone-beam-CT (CBCT) readout through a two-institution study. The technique has potential for wide and robust applicability through reliance on CBCT readout.Approach. Three treatment plans (3-field, TG119-C-shape spine, 4-target SRS) were created by two independent institutions (Institutions A and B). A Varian Truebeam linear accelerator was used to deliver the plans to NIPAM polymer gel dosimeters produced at both institutions using an identical approach. For readout, a slow CBCT scan mode was used to acquire pre- and post-irradiation images of the gel (1 mm slice thickness). Independent gel analysis tools were used to process the PGD images (A: VistaAce software, B: in-house MATLAB code). Comparing planned and measured doses, the analysis involved a combination of 1D line profiles, 2D contour plots, and 3D global gamma maps (criteria ranging between 2%1 mm and 5%2 mm, with a 10% dose threshold).Main results. For all gamma criteria tested, the 3D gamma pass rates were all above 90% for 3-field and 88% for the SRS plan. For the C-shape spine plan, we benchmarked our 2% 2 mm result against previously published work using film analysis (93.4%). For 2%2 mm, 99.4% (Institution A data), and 89.7% (Institution B data) were obtained based on VistaAce software analysis, 83.7% (Institution A data), and 82.9% (Institution B data) based on MATLAB.Significance. The benchmark data demonstrate that when two institutions follow the same rigorous procedures gamma passing rates up to 99%, for 2%2 mm criteria can be achieved for substantively different treatment plans. The use of different software and calibration techniques may have contributed to the variation in the 3D gamma results. By sharing the data across institutions, we observe the gamma passing rate is more consistent within each pipeline, indicating the need for standardized analysis methods.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Aceleradores de Partículas , Radiometría , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada de Haz Cónico/métodos , Radiometría/métodos , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Imagenología Tridimensional/métodos , Polímeros/química
6.
Cureus ; 16(8): e66108, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39229440

RESUMEN

Introduction This study aimed to evaluate the setup accuracy of the new shim mask with mouth bite compared to the standard full brain mask in stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments for brain metastases or tumors. Method A combined retrospective and prospective design was employed, involving 40 patients treated at our center. Patients previously treated using standard head masks formed the retrospective cohort, while those treated with the Shim mask and mouth bite formed the prospective cohort. Daily cone-beam computed tomography (CBCT) scans were obtained before each treatment session to ensure patient setup accuracy. Key metrics included absolute shifts in translational and rotational directions, the number of repeat CBCTs, and the time interval between CBCTs. Results The Shim mask significantly reduced the mean setup errors in the lateral translation (p=0.022) from 0.17 cm (SD=0.10) to 0.10 cm (SD=0.10), and in X-axis rotation (p=0.030) from 0.79° (SD=0.43) to 0.47° (SD=0.47). By considering cutoff points of 1 mm in translational and 1° in rotational directions, the Shim mask was significantly more accurate in the lateral direction (p=0.004). Moreover, while 70% of patients in the standard group required repeat CBCT scans, none in the Shim group did, resulting in an average time saving of 10.4 minutes per patient. Conclusion The Shim mask with mouth bite offers enhanced immobilization accuracy in SRT/SRS treatments, leading to time and potential cost savings by reducing the need for repeat CBCT scans. This underscores the importance of adopting innovative immobilization techniques to optimize patient outcomes.

7.
J Neurosurg Case Lessons ; 7(11)2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38467040

RESUMEN

BACKGROUND: Acinic cell carcinomas (AcCCs), rare malignancies of the salivary glands, often recur and metastasize, particularly in the skull base. Conventional radical resection can be invasive for skull base AcCCs adjacent to cranial nerves and major vasculature, and the effectiveness of stereotactic radiosurgery (SRS) as an alternative is not well established. OBSERVATIONS: This case report details the application of SRS for recurrent skull base AcCCs. A 71-year-old male with a history of resection for a right mandibular AcCC 23 years earlier experienced tumor recurrence involving the right cavernous sinus and nasal cavity. He underwent endoscopic transnasal surgery followed by SRS targeting different tumor locations-the cavernous sinus to the pterygopalatine fossa, maxillary sinus, and clivus-each with a prescribed dose of 20 Gy to the 40% to 50% isodose line. After the first skull base metastasis, additional sessions of localized SRS after endoscopic surgery led to a 12-year survival without sequela. LESSONS: This is a report indicating that SRS for skull base AcCCs can achieve favorable local control, functional preservation, and long-term survival. SRS may be suitable for skull base AcCC given the lesion's tendency toward multiple local recurrences. Further investigation is needed to validate the treatment's efficacy.

8.
Phys Eng Sci Med ; 45(2): 577-587, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35404028

RESUMEN

The aim of this study was to present our experience on clinical implementation of HyperArc including dosimetric comparison between VMAT and HyperArc plans and dosimetric verification of HyperArc. In this study, eleven previously treated cases of brain metastasis were selected from our brain stereotactic radiotherapy program. The cases were retrospectively planned using HyperArc technique and the plan quality was evaluated. In addition, dosimetric effects of HyperArc plan with different energies and using jaw tracking technique were evaluated. Furthermore, dosimetric verification of HyperArc plans was performed using ion chamber and radiochromic film. Our results of dosimetric comparison shows that HyperArc technique improved both conformity index and gradient index compared to VMAT plans. We also found that using 6MV flattening filter free (6MV-FFF) beam improves gradient index in HyperArc plans compared to using 6MV flattening filter beam. Furthermore, our results show that jaw tracking technique reduces the size of low dose volume while maintaining similar target coverage, conformity index, and gradient index. In our dosimetric verification study, results of ion chamber and film measurement indicate no significant difference between VMAT and HyperArc plans. In conclusion, HyperArc simplifies planning of stereotactic treatment for brain and improves the dosimetry in treatment plans. Additionally, HyperArc provides for a safe and efficient treatment delivery system for stereotactic treatments to brain.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos
9.
Technol Cancer Res Treat ; 21: 15330338221100231, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35579876

RESUMEN

Purpose: The first clinical biology-guided radiation therapy (BgRT) system-RefleXionTM X1-was installed and commissioned for clinical use at our institution. This study aimed at evaluating the treatment plan quality and delivery efficiency for IMRT/SBRT cases without PET guidance. Methods: A total of 42 patient plans across 6 cancer sites (conventionally fractionated lung, head, and neck, anus, prostate, brain, and lung SBRT) planned with the EclipseTM treatment planning system (TPS) and treated with either a TrueBeam® or Trilogy® were selected for this retrospective study. For each Eclipse VMAT plan, 2 corresponding plans were generated on the X1 TPS with 10 mm jaws (X1-10mm) and 20 mm jaws (X1-20mm) using our institutional planning constraints. All clinically relevant metrics in this study, including PTV D95%, PTV D2%, Conformity Index (CI), R50, organs-at-risk (OAR) constraints, and beam-on time were analyzed and compared between 126 VMAT and RefleXion plans using paired t-tests. Results: All but 3 planning metrics were either equivalent or superior for the X1-10mm plans as compared to the Eclipse VMAT plans across all planning sites investigated. The Eclipse VMAT and X1-10mm plans generally achieved superior plan quality and sharper dose fall-off superior/inferior to targets as compared to the X1-20mm plans, however, the X1-20mm plans were still considered acceptable for treatment. On average, the required beam-on time increased by a factor of 1.6 across all sites for X1-10mm compared to X1-20mm plans. Conclusions: Clinically acceptable IMRT/SBRT treatment plans were generated with the X1 TPS for both the 10 mm and 20 mm jaw settings.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Biología , Humanos , Masculino , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
10.
Otolaryngol Clin North Am ; 55(2): 331-341, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35256175

RESUMEN

Acromegaly results from excessive secretion of insulinlike growth factor-1 and growth hormone, which most commonly occurs because of pituitary somatotrophinoma. Diagnostic features of acromegaly include elevated insulinlike growth factor-1 and growth hormone; lesion on brain MRI; and clinically dysmorphic features, such as soft tissue swelling, jaw prognathism, and acral overgrowth. Transsphenoidal resection is the primary therapy for individuals with acromegaly, even in the cases where gross total resection is not possible because of parasellar extension and cavernous sinus involvement. For recurrent or persistent disease after resection, systemic medications and stereotactic radiosurgery are used.


Asunto(s)
Acromegalia , Adenoma , Adenoma Hipofisario Secretor de Hormona del Crecimiento , Hormona de Crecimiento Humana , Neoplasias Hipofisarias , Radiocirugia , Acromegalia/diagnóstico , Acromegalia/etiología , Acromegalia/cirugía , Adenoma/cirugía , Adenoma Hipofisario Secretor de Hormona del Crecimiento/complicaciones , Adenoma Hipofisario Secretor de Hormona del Crecimiento/patología , Adenoma Hipofisario Secretor de Hormona del Crecimiento/cirugía , Humanos , Neoplasias Hipofisarias/complicaciones , Neoplasias Hipofisarias/cirugía , Radiocirugia/efectos adversos , Radiocirugia/métodos , Estudios Retrospectivos , Resultado del Tratamiento
11.
Cureus ; 13(12): e20774, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35111459

RESUMEN

Trigeminal neuralgia (TN) is a neuropathic pain disorder characterized by paroxysmal pain in the maxillary and mandibular regions of the face. Morbihan syndrome is a disease that classically presents with dermatologic findings, including progressive facial edema and erythema. There are no previous reports of the onset of trigeminal neuralgia with Morbihan syndrome or previous reports describing improvement in symptoms of Morbihan syndrome with treatment of trigeminal neuralgia. We describe the case of a 62-year-old female who presented with trigeminal neuralgia and shortly thereafter developed significant facial edema and was diagnosed with Morbihan syndrome. The neuralgia was refractory to medical management and was effectively treated with stereotactic radiosurgery (SRS). This coincided with an improvement in her Morbihan syndrome that is now controlled following stereotactic radiosurgery and continued lymphatic massage.

12.
Neurosurgery ; 88(2): 366-374, 2021 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-32860409

RESUMEN

BACKGROUND: Embolization of brain arteriovenous malformations (AVMs) using ethylene-vinyl alcohol copolymer (Onyx) embolization may influence the treatment effects of stereotactic radiosurgery (SRS) differently than other embolysates. OBJECTIVE: To compare the outcomes of pre-SRS AVM embolization with vs without Onyx through a multicenter, retrospective matched cohort study. METHODS: We retrospectively reviewed International Radiosurgery Research Foundation AVM databases from 1987 to 2018. Embolized AVMs treated with SRS were selected and categorized based on embolysate usage into Onyx embolization (OE + SRS) or non-Onyx embolization (NOE + SRS) cohorts. The 2 cohorts were matched in a 1:1 ratio using de novo AVM features for comparative analysis of outcomes. RESULTS: The matched cohorts each comprised 45 patients. Crude AVM obliteration rates were similar between the matched OE + SRS vs NOE + SRS cohorts (47% vs 51%; odds ratio [OR] = 0.837, P = .673). Cumulative probabilities of obliteration were also similar between the OE + SRS vs NOE + SRS cohorts (subhazard ratio = 0.992, P = .980). Rates of post-SRS hemorrhage, all-cause mortality, radiation-induced changes, cyst formation, and embolization-associated complications were similar between the matched cohorts. Sensitivity analysis for AVMs in the OE + SRS cohort embolized with Onyx alone revealed a higher rate of asymptomatic embolization-associated complications in this subgroup compared to the NOE + SRS cohort (36% vs 15%; OR = 3.297, P = .034), but the symptomatic complication rates were similar. CONCLUSION: Nidal embolization using Onyx does not appear to differentially impact the outcomes of AVM SRS compared with non-Onyx embolysates. The embolic agent selected for pre-SRS AVM embolization should reflect both the experience of the neurointerventionalist and target of endovascular intervention.


Asunto(s)
Embolización Terapéutica/métodos , Malformaciones Arteriovenosas Intracraneales/terapia , Polivinilos/uso terapéutico , Radiocirugia , Adolescente , Adulto , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
13.
J Med Phys ; 46(3): 204-210, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34703105

RESUMEN

The primary purpose of the study is to evaluate the implementation of Helical TomoTherapy (HT) for eligible stereotactic radiosurgery/stereotactic body radiotherapy/stereotactic ablative radiotherapy (SRS/SBRT/SABR) cases using TomoEDGE option. The study focuses on reduction of treatment time without compromise in plan quality using TomoEDGE. It is a mode in HT that uses a dynamic opening of the jaws during treatment delivery to reduce the dose penumbra which otherwise is not possible with fixed jaws option. Eligible SRS/SBRT/SABR cases of lung, liver, and spine were used in this study. All planning parameters such as dose prescription to target and critical organs, pitch, and modulation factor were same in all the plans of the same patient with modifications in the field width and jaw mode. First set of plans with 2.5 cm width and second set of plans with 5 cm width were done in dynamic TomoEDGE mode. Third set of plans created with 5 cm width fixed jaw mode and fourth set of plans with 2.5 cm fixed jaw mode for comparison purpose were done. Our observations achieved that a significant milestone with reduction of up to 34.3% in treatment time of liver cases, 35.2% in lung cases, and 28.7% in spine cases was observed using dynamic TomoEDGE mode with 5 cm width, while no significant variation in the planning results compared with plans using 2.5 cm dynamic TomoEDGE option. TomoEDGE is an efficient and useful mode in TomoTherapy to reduce the treatment time with bigger field width in SRS/SBRT/SABR cases without significant changes in the plan quality.

14.
Cureus ; 12(8): e9833, 2020 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-32832305

RESUMEN

Background Stereotactic radiosurgery (SRS) or fractionated SRS (fSRS) are effective options for the treatment of brain metastases. When treating multiple metastases with a linear accelerator-based approach, a single isocenter allows for efficient treatment delivery. In this study, we present our findings comparing dosimetric parameters of Brainlab (Munich, Germany) Elements™ Multiple Brain Mets SRS (MME) software (version 1.5 versus version 2.0) for a variety of scenarios and patients. The impact of multileaf collimator design and function on plan quality within the software was also evaluated. Materials and methods Twenty previously treated patients with a total of 58 lesions (from one to seven lesions each) were replanned with an updated version of the multiple brain Mets software solution. For each plan, the mean conformity index (CI), mean gradient index (GI), the volume of normal brain receiving 12 Gy (V12), and mean brain dose were evaluated. Additionally, all v2.0 plans were further evaluated with jaw tracking for by Elekta (Stockholm, Sweden) and HD120™ multileaf collimator by Varian Medical Systems (Palo Alto, USA). Results The new software version demonstrated improvements for CI, GI and V12 (p <0.01). For the Elekta Agility™ multileaf collimator, jaw tracking improved all dosimetric parameters except for CI (p =0.178) and mean brain dose (p =0.93). For the Varian with HD120 multileaf collimator, all parameters improved. Conclusions The software enhancements in v2.0 of the software provided improvements in planning efficiency and dosimetric parameters. Differences in multileaf collimator design may provide an additional incremental benefit in a subset of clinical scenarios.

15.
J Neurosurg Pediatr ; : 1-8, 2019 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-31604323

RESUMEN

Pediatric pituitary adenomas (PPAs) are rare neoplasms with a propensity for unusual presentations and an aggressive clinical course. Here, the authors describe 6 highly atypical PPAs to highlight this tendency and discuss unexpected management challenges.A 14-year-old girl presented with acute hemiparesis and aphasia. MRI revealed a pituitary macroadenoma causing internal carotid artery invasion/obliteration without acute apoplexy, which was treated via emergent transsphenoidal resection (TSR). Another 14-year-old girl developed precocious galactorrhea due to macroprolactinoma, which was medically managed. Several years later, she re-presented with acute, severe, bitemporal hemianopia during her third trimester of pregnancy, requiring emergent induction of labor followed by TSR. A 13-year-old boy was incidentally diagnosed with a prolactinoma after routine orthodontic radiographs captured a subtly abnormal sella. An 18-year-old male self-diagnosed pituitary gigantism through a school report on pituitary disease. A 17-year-old boy was diagnosed with Cushing disease by his basketball coach, a former endocrinologist. A 12-year-old girl with growth arrest and weight gain was diagnosed with Cushing disease, which was initially treated via TSR but subsequently recurred and ultimately required 12 operations, 5 radiation treatments involving 3 modalities, bilateral adrenalectomy, and chemotherapy. Despite these efforts, she ultimately died from pituitary carcinoma.

16.
Artículo en Inglés | MEDLINE | ID: mdl-30181829

RESUMEN

Background: Brain metastasis (BM) from colorectal cancer (CRC) is rare with the incidence ranging from 0.6% to 3.2%. There is also an increased incidence of BM with rectal primaries and is consistent with this patient's presentation. Overall, there is scarce literature on the symptoms of patients who present with CRC BMs. Objectives: We present a case of brain metastasis in colorectal cancer presenting with hypertensive urgency and severe headache. Methods and results: This case highlights that neurological deficits are not necessary for BMs in patients with CRC and summarizes and reviews the associated literature regarding BM in CRC. A 57-year-old female with a past medical history of recently diagnosed stage IV moderately differentiated distal rectal adenocarcinoma with liver and lung metastasis was admitted with the primary complaint of hypertensive urgency, severe headache, intractable nausea and vomiting, and diarrhea. Magnetic resonance imaging brain showed a left cerebellar lesion measuring 3.6 × 3.2 × 2.9 cm, ipsilateral transtentorial herniation, and obliteration of the fourth ventricle. The patient was started on steroids and transferred for an urgent neurosurgical intervention to a tertiary care center. Conclusions: Even though BMs are rare in CRC, clinicians should have a high index of suspicion with complaints like hypertensive urgency, headache, nausea, vomiting, vertigo, and blurring of vision triggering imaging studies to rule out BM. The approach to BM has become increasingly individualized as surgical and radiosurgical therapies have continued to evolve Abbreviations: CRC: Colorectal cancer; BM: Brain metastasis; FOLFOX: Folinic acid, fluorouracil and oxaliplatin; CT: Computed tomography; IV: Intravenous; PO: By mouth; BAER: Brain auditory evoked response hearing testing; SSEP's: Somatosensory evoked potentials; BMFI: Brain metastasis free interval; WBRT: Whole-brain radiation therapy; SRS: Stereotactic radiosurgery.

17.
J Neurosurg Spine ; 28(1): 72-78, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29087812

RESUMEN

OBJECTIVE The aim of this study was to evaluate the safety and efficacy of kyphoplasty treatment prior to spine stereotactic radiosurgery (SRS) in patients with spine metastases. METHODS A retrospective review of charts, radiology reports, and images was performed for all patients who received SRS (single fraction; either standalone or post-kyphoplasty) at a large tertiary cancer center between January 2012 and July 2015. Patient and tumor variables were documented, as well as treatment planning data and dosimetry. To measure the photon scatter due to polymethyl methacrylate, megavolt photon beam attenuation was determined experimentally as it passed through a kyphoplasty cement phantom. Corrected electron density values were recalculated and compared with uncorrected values. RESULTS Of 192 treatment levels in 164 unique patients who underwent single-fraction SRS, 17 (8.8%) were treated with kyphoplasty prior to radiation delivery to the index level. The median time from kyphoplasty to SRS was 22 days. Four of 192 treatments (2%) demonstrated local tumor recurrence or progression at the time of analysis. Of the 4 local failures, 1 patient had kyphoplasty prior to SRS. This recurrence occurred 18 months after SRS in the setting of widespread systemic disease and spinal tumor progression. Dosimetric review demonstrated a lower than average treatment dose for this case compared with the rest of the cohort. There were no significant differences in dosimetry analysis between the group of patients who underwent kyphoplasty prior to SRS and the remaining patients in the cohort. A preliminary analysis of polymethyl methacrylate showed that dosimetric errors due to uncorrected electron density values were insignificant. CONCLUSIONS In cases without epidural spinal cord compression, stabilization with cement augmentation prior to SRS is safe and does not alter the efficacy of the radiation or preclude physicians from adhering to SRS planning and contouring guidelines.


Asunto(s)
Fracturas por Compresión/cirugía , Cifoplastia , Radiocirugia , Fracturas de la Columna Vertebral/cirugía , Neoplasias de la Columna Vertebral/radioterapia , Neoplasias de la Columna Vertebral/secundario , Adulto , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Femenino , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/etiología , Humanos , Masculino , Persona de Mediana Edad , Radiometría , Estudios Retrospectivos , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/etiología , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Adulto Joven
18.
J Craniovertebr Junction Spine ; 8(3): 285-287, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29021684

RESUMEN

Improvements in cancer therapy have led to increased patient survival times in spite of metastatic spinal disease in many forms of cancer. Conventional treatment methods often employ radiotherapy with or without surgery depending on the neurological status, mechanical instability, and the extent of tumor. Percutaneous vertebroplasty as well as stereotactic radiosurgery (SRS) have arisen as common modalities of treatment of spinal metastasis in which neurological compromise or spinal instability and deformity is not of significant concern. These treatments, when used in combination, have been shown to provide early pain relief and effective tumor control while avoiding surgical resection, fixation, and lengthy recovery times. We present a case unique in the literature for the use of this combination treatment for tumors of the C2 vertebral body. While limited in application to patients without overt atlantoaxial instability or significant spinal canal compromise, we believe it provides a significant benefit in decreasing morbidity and improving early adherence to systemic therapy.

19.
Med Phys ; 44(10): 5509-5516, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28714067

RESUMEN

PURPOSE: To evaluate the performance of a commercial plastic scintillator detector (PSD) for small-field stereotactic patient-specific quality assurance (QA) measurements using flattening-filter-free beam. METHODS: A total of 10 spherical targets [volume range: (0.03 cc-2 cc)] were planned with two techniques: (a) dynamic conformal arc (DCA-10 plans) and (b) volumetric modulated arc therapy (VMAT-10 plans). All plans were generated using Varian Eclipse treatment planning system, and AcurosXB v.13 algorithm in 1.0 mm grid size. Additionally, 14 previously treated cranial and spine SRS plans were evaluated [6 DCA, 8 VMAT, volume range: (0.04 cc-119.02 cc)]. Plan modulation was quantified via two metrics: MU per prescription dose (MU/Rx) and Average Leaf Pair Opening (ALPO). QA was performed on the Varian Edge linear accelerator equipped with HDMLC. Three detectors were used: (a) PinPoint ion chamber (PTW; active volume 0.015 cc), (b) Exradin W1 PSD (Standard Imaging; active volume 0.002 cc), and (c) Gafchromic EBT3 film (Ashland). PinPoint chamber and PSD were positioned perpendicular to beam axis in a Lucy phantom (Standard Imaging); films were placed horizontally capturing the coronal plane. RESULTS: PSD, film, and PinPoint chamber measured average differences of 1.00 ± 1.54%, 1.30 ± 1.69%, and -0.66 ± 2.36%, respectively, compared to AcurosXB dose calculation. As the target volume decreased, PinPoint chamber measured lower doses (maximum -5.07% at 0.07 cc target), while PSD and film measured higher doses (2.87% and 2.54% at 0.03 cc target) than AcurosXB. Film agreed with the benchmark detector PSD by an average difference of 0.31 ± 1.20%, but suffered from larger uncertainty; PinPoint chamber underestimated dose by more than 4% for targets smaller than 0.2 cc. Taking PSD as the measurement standard, DCA plans achieved good QA results across all volumes studied, with an average of -0.07 ± 0.89%; for VMAT plans, PSD measured consistently higher dose (1.95 ± 1.36%) than AcurosXB. Correlation study revealed that plan modulation quantified by both MU/Rx and ALPO correlated significantly with QA results. CONCLUSION: Among all three detectors, PSD demonstrated superior performances in plans with small fields and heavy modulation. High consistency and low uncertainty made PSD a suitable detector for clinical routine SRS QA. PinPoint chamber should be avoided for targets smaller than 0.2 cc; film dosimetry can be utilized with careful evaluation of its uncertainty bracket. Compared to PSD measurements, AcurosXB calculation demonstrated high accuracy for nonmodulated small fields. The positive correlation between plan modulation and QA discrepancy calls for our attention for clinical SRS plans with high modulation.


Asunto(s)
Plásticos , Radiocirugia/instrumentación , Conteo por Cintilación/instrumentación , Humanos , Fantasmas de Imagen , Control de Calidad , Planificación de la Radioterapia Asistida por Computador
20.
J Neurosurg Spine ; 27(6): 700-708, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28984511

RESUMEN

OBJECTIVE Treatment of epidural spinal cord compression (ESCC) caused by tumor includes surgical decompression and stabilization followed by postoperative radiation. In the case of severe axial loading impairment, anterior column reconstruction is indicated. The authors describe the use of interbody distraction to restore vertebral body height and correct kyphotic angulation prior to reconstruction with polymethylmethacrylate (PMMA), and report the long-term durability of such reconstruction. METHODS A single institution, prospective series of patients with ESCC undergoing single-stage decompression, anterior column reconstruction, and posterior instrumentation from 2013 to 2016 was retrospectively analyzed. Several demographic, perioperative, and radiographic measurements were collected. Descriptive statistics were compiled, in addition to postoperative changes in anterior height, posterior height, and kyphosis. Paired Student t-tests were performed for each variable. Overall survival was calculated using the techniques described by Kaplan and Meier. RESULTS Twenty-one patients underwent single-stage posterior decompression with interbody distraction and anterior column reconstruction using PMMA. The median age and Karnofsky Performance Scale score were 61 years and 70, respectively. Primary tumors included renal cell (n = 8), lung (n = 4), multiple myeloma (n = 2), prostate (n = 2), and other (n = 5). Eighteen patients underwent a single-level vertebral body reconstruction and 3 underwent multilevel transpedicular corpectomies. The median survival duration was 13.3 months. In the immediate postoperative setting, statistically significant improvement was noted in anterior body height (p = 0.0017, 95% confidence interval [CI] -4.15 to -1.11) and posterior body height (p = 0.0116, 95% CI -3.14 to -0.45) in all patients, and improved kyphosis was observed in those with oblique endplates (p = 0.0002, 95% CI 11.16-20.27). In the median follow-up duration of 13.9 months, the authors observed 3 cases of asymptomatic PMMA subsidence. One patient required reoperation in the form of extension of fusion. CONCLUSIONS In situ interbody distraction allows safe and durable reconstruction with PMMA, restores vertebral height, and corrects kyphotic deformities associated with severe pathological fractures caused by tumor. This is accomplished with minimal manipulation of the thecal sac and avoiding an extensive 360° surgical approach in patients who cannot tolerate extensive surgery.


Asunto(s)
Polimetil Metacrilato/uso terapéutico , Adulto , Anciano , Descompresión Quirúrgica/métodos , Femenino , Fracturas Espontáneas/patología , Fracturas Espontáneas/cirugía , Humanos , Cifosis/patología , Cifosis/cirugía , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Compresión de la Médula Espinal/cirugía , Fracturas de la Columna Vertebral/cirugía , Neoplasias de la Columna Vertebral/patología , Neoplasias de la Columna Vertebral/cirugía , Vértebras Torácicas/cirugía , Resultado del Tratamiento