Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 952
Filtrar
Más filtros

Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 25(1): 552, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39014409

RESUMEN

BACKGROUND: To evaluate the effectiveness of a sequential internal fixation strategy and intramedullary nailing with plate augmentation (IMN/PA) for bone reconstruction in the management of infected femoral shaft defects using the Masquelet technique. METHODS: We performed a retrospective descriptive cohort study of 21 patients (mean age, 36.4 years) with infected bone defects of the femoral shaft treated by the Masquelet technique with a minimum follow-up of 18 months after second stage. After aggressive debridement, temporary stabilisation (T1) was achieved by an antibiotic-loaded bone cement spacer and internal fixation with a bone cement-coated locking plate. At second stage (T2), the spacer and the locking plate were removed following re-debridement, and IMN/PA was used as definitive fixation together with bone grafting. We evaluated the following clinical outcomes: infection recurrence, bone union time, complications, and the affected limb's knee joint function. RESULTS: The median and quartiles of bone defect length was 7 (4.75-9.5) cm. Four patients required iterative debridement for infection recurrence after T1. The median of interval between T1 and T2 was 10 (9-19) weeks. At a median follow-up of 22 (20-27.5) months, none of the patients experienced recurrence of infection. Bone union was achieved at 7 (6-8.5) months in all patients, with one patient experiencing delayed union at the distal end of bone defect due to screws loosening. At the last follow-up, the median of flexion ROM of the knee joint was 120 (105-120.0)°. CONCLUSIONS: For infected femoral shaft bone defects treated by the Masquelet technique, sequential internal fixation and IMN/PA for the reconstruction can provide excellent mechanical stability, which is beneficial for early functional exercise and bone union, and does not increase the rate of infection recurrence.


Asunto(s)
Clavos Ortopédicos , Placas Óseas , Desbridamiento , Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Masculino , Estudios Retrospectivos , Femenino , Adulto , Fracturas del Fémur/cirugía , Persona de Mediana Edad , Desbridamiento/métodos , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Adulto Joven , Resultado del Tratamiento , Trasplante Óseo/métodos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Estudios de Seguimiento , Cementos para Huesos/uso terapéutico , Antibacterianos/uso terapéutico , Antibacterianos/administración & dosificación , Fémur/cirugía , Adolescente
2.
Altern Ther Health Med ; 30(9): 72-77, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38401096

RESUMEN

Objective: The objective of this study was to assess the short-term clinical efficacy of the short-term clinical efficacy of bone cement intramedullary support combined with locked plate fixation in the treatment of such fractures. Methods: A retrospective study including 21 patients was reviewed at an urban level one trauma center. There were 17 males and 4 females, with a mean age of 33.9 years. Gustilo grade was II (12 cases), III-A (6 cases), III-B (2 cases), and III-C (1 case). Two fractures were AO-OTA type 33A3, 9 cases were type 33C2, and 10 cases were type 33C3. After the first stage debridement and temporary external fixation, all patients received bone cement intramedullary support combined with locked plate fixation through an anterolateral incision at the second stage.. The perioperative complications, need for bone graft, alignment, and radiographic union were recorded. At 1-year follow-up, the range of knee motion was recorded, and functional results were evaluated by the Hospital for Special Surgery (HSS) knee score. Results: All 21 patients were followed up for 12-36 months, with an average of 18.7 months. 1 case had superficial wound infection, and 2 cases had partial skin edge necrosis of the original open wound. After symptomatic dressing changes, they all healed well. 4 cases had autogenous bone grafting. 18 patients (85.7%) achieved radiographic union, with a mean union time of 6.2 months. Two patients underwent secondary operation 9 months after surgery due to nonunion and finally united after autologous bone grafting. One patient developed a deep infection 8 months after surgery and was successfully treated with Masquelet technique. Finally, bone union was achieved 7 months after surgery. The alignment was good in 17 patients (81.0%). No deep infection or hardware failure occurred during 1-year follow-up. The average range of knee extension and flexion was 5.2 ° and 106.8 °, respectively. The HSS score averaged 83.6. Conclusions: Bone cement intramedullary support combined with locked plate fixation was an effective treatment modality of open distal femur fractures with high union rate, low complication, adequate alignment and satisfactory functional outcomes.


Asunto(s)
Cementos para Huesos , Placas Óseas , Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Masculino , Femenino , Adulto , Cementos para Huesos/uso terapéutico , Estudios Retrospectivos , Fracturas del Fémur/cirugía , Persona de Mediana Edad , Fijación Intramedular de Fracturas/métodos , Adulto Joven , Fracturas Abiertas/cirugía , Resultado del Tratamiento , Fracturas Femorales Distales
3.
Int Orthop ; 48(5): 1171-1178, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38443715

RESUMEN

PURPOSE: After cemented total hip arthroplasty, the risk of periprosthetic fracture (PPF) of taper-slip stems is higher than that of composite-beam stems. We aimed to assess the conditions resulting in PPFs of taper-slip stems using a falling weight. METHODS: Taper-slip stems were fixed to five types of simulated bone models using bone cement, and the fractures were evaluated by dropping stainless-steel weights from a predetermined height onto the heads. The periprosthetic fracture height in 50% of the bone models (PPFH50) was calculated using the staircase method. RESULTS: For the fixation with 0° of flexion, the values for PPFH50 were 61 ± 11, 60 ± 13, above 110, 108 ± 49, and 78 ± 12 cm for the cobalt-chromium-molybdenum alloy, stainless steel alloy (SUS), titanium alloy (Ti), smooth surface, and thick cement mantle models, respectively; for the fixation with 10° of flexion (considering flexure), the PPFH50 values were 77 ± 5, 85 ± 9, 90 ± 2, 89 ± 5, and 81 ± 11 cm, respectively. The fracture rates of the polished-surface stems were 78.6 and 35.7% at the proximal and distal sites, respectively (p < 0.05); the fracture rates of the smooth-surface stems were 14.2 and 100%, respectively (p < 0.05). CONCLUSION: The impact tests demonstrated that the conditions that were less likely to cause PPFs were use of Ti, a smooth surface, a thick cement mantle, and probably, use of SUS.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Fracturas Periprotésicas/epidemiología , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Prótesis de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Reoperación/efectos adversos , Cementos para Huesos , Diseño de Prótesis , Aleaciones , Fracturas del Fémur/cirugía
4.
Acta Orthop ; 95: 492-497, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39239991

RESUMEN

BACKGROUND AND PURPOSE:  Periprosthetic femoral fracture (PFF) is a significant complication of total hip arthroplasty (THA). Although biomechanical studies have indicated that the technique by which the femoral canal is prepared plays a role, few clinical studies have reported on how this might affect the fracture risk. This study compares the fracture risk between compaction and broaching with toothed instruments in cementless THA. METHODS: Prospectively collected data from the quality register of a high-volume hospital was used. All primary arthroplasties using the Corail stem (DePuy Synthes) were included. All femoral fractures occurring within the first 90 days after the operation were included in the analysis. We determined the relative risk of sustaining PFF with compaction compared with broaching and adjusted for confounders (sex, age group, BMI, and use of a collared stem) using multivariable Poisson regression. RESULTS:  6,788 primary THAs performed between November 2009 and May 2023 were available for analysis. 66% were women and the mean age was 65.0 years. 129 (1.9%) fractures occurred during the first 90 days after the operation, 92 (2.3%) in the compaction group and 37 (1.3%) in the broaching group. The unadjusted relative risk of fracture in the compaction group compared with the broaching group was 1.82 (95% confidence interval [CI] 1.25-2.66), whereas the adjusted relative risk was 1.70 (CI 1.10-2.70). CONCLUSION: Compaction was associated with more periprosthetic fractures than broaching (2.3% versus 1.3%) within 90 days after surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Fracturas Periprotésicas , Complicaciones Posoperatorias , Humanos , Femenino , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Masculino , Anciano , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Prótesis de Cadera/efectos adversos , Factores de Riesgo , Estudios Prospectivos , Complicaciones Intraoperatorias/etiología
5.
Eur J Orthop Surg Traumatol ; 34(4): 2147-2153, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38564013

RESUMEN

INTRODUCTION: Distal femur fractures account for 3-6% of all femur fractures. Internal fixation of most distal femur fractures with an anatomic lateral locking plate should permit some motion at the metaphyseal portion of the fracture when secondary bone healing is planned by the operating surgeon. While several studies have been performed evaluating union rates for distal femur fractures with stainless steel and titanium plates, the timing of callus formation between stainless steel and titanium implants used as bridge plates for distal femur fractures (AO/OTA 33-A and -C) has been investigated to a lesser extent. We hypothesize that callus will be visualized earlier with post-operative radiographs with titanium versus stainless steel bridge plates. METHODS: We retrospectively reviewed a consecutive cohort of patients over 18 years of age with acute AO/OTA 33-A and 33-C fracture patterns treated with an isolated stainless steel or titanium lateral bridge plate within 4 weeks of injury by a single fellowship-trained orthopedic trauma surgeon from 2011 to 2020 at one academic Level 1 trauma center. An independent, fellowship-trained orthopedic trauma attending surgeon reviewed anterior-posterior (AP) and lateral radiographs from every available post-operative clinic visit and graded them using the Modified Radiographic Score for Tibia (mRUST). RESULTS: Twenty-five subjects were included in the study with 10 with stainless steel and 15 with titanium plates. There were no significant differences in demographics between both groups, including age, sex, BMI, injury classification, open versus closed, mechanism, and laterality. Statistically significant increased mRUST scores, indicating increased callus formation, were seen on 12-week radiographs (8.4 vs. 11.9, p = 0.02) when titanium bridge plates were used. There were no statistically significant differences in mRUST scores at 6 or 24-weeks, but scores in the titanium group were higher in at every timepoint. DISCUSSION: In conclusion, we observed greater callus formation at 12 weeks after internal fixation of 33-A and 33-C distal femur fractures treated with titanium locked lateral distal femoral bridge plates compared to stainless steel plates. Our data suggest that titanium metallurgy may have quicker callus formation compared to stainless steel if an isolated, lateral locked bridge plate is chosen for distal femur fracture fixation.


Asunto(s)
Placas Óseas , Callo Óseo , Fracturas del Fémur , Fijación Interna de Fracturas , Acero Inoxidable , Titanio , Humanos , Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/fisiopatología , Estudios Retrospectivos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Masculino , Callo Óseo/diagnóstico por imagen , Femenino , Persona de Mediana Edad , Adulto , Radiografía , Curación de Fractura/fisiología , Anciano , Fracturas Femorales Distales
6.
J Orthop Traumatol ; 25(1): 35, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39023807

RESUMEN

INTRODUCTION: Periprosthetic femoral fractures (PFFs) following hip arthroplasty, especially Vancouver B2 and B3 fractures, present a challenge due to the association with a loose femoral stem, necessitating either open reduction and internal fixation or stem revision. This study aims to compare outcomes between uncemented and cemented stem revisions in managing Vancouver B2 and B3 fractures, considering factors such as hip-related complications, reoperations, and clinical outcome. METHODS: A retrospective cohort study was conducted at Danderyd Hospital, Sweden, from 2008 to 2022, encompassing operatively treated Vancouver B2 and B3 fractures. Patients were categorized into uncemented and cemented stem revision groups, with data collected on complications, revision surgeries, fracture healing times, and clinical outcomes. RESULTS: A total of 241 patients were identified. Significant differences were observed between the two groups in patient demographics, with the cemented group comprising older patients and more females. Follow up ranged from 1 to 15 years. Average follow up time was 3.9 years for the cemented group and 5.5 years for the uncemented group. The cemented stems demonstrated lower rates of dislocation (8.9% versus 22.5%, P = 0.004) and stem loosening (0.6% versus 9.3%, P = 0.004) than the uncemented method. Moreover, the cemented group exhibited shorter fracture healing times (11.4 weeks versus 16.7 weeks, P = 0.034). There was no difference in clinical outcome between groups. Mortality was higher in the cemented group. CONCLUSIONS: This retrospective study indicates that cemented stem revision for Vancouver B2-3 fractures is correlated with lower dislocation and stem loosening rates, necessitating fewer reoperations and shorter fracture healing times compared with the uncemented approach. The cemented group had a notably higher mortality rate, urging caution in its clinical interpretation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cementos para Huesos , Fracturas del Fémur , Fracturas Periprotésicas , Reoperación , Humanos , Femenino , Estudios Retrospectivos , Masculino , Anciano , Fracturas Periprotésicas/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/cirugía , Persona de Mediana Edad , Anciano de 80 o más Años , Prótesis de Cadera , Resultado del Tratamiento , Suecia , Complicaciones Posoperatorias/cirugía , Complicaciones Posoperatorias/etiología
7.
J Mater Sci Mater Med ; 34(11): 57, 2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-37938467

RESUMEN

Early fracture fixation is the critical factor in fracture healing. Common internal fracture implants are made of metallic materials, which often affects the imaging quality of CT and MRI. Most patients will choose secondary surgery to remove the internal fixation implants, which causes secondary damage to them. The development of new degradable internal fracture implants has attracted more and more attention from orthopedic surgeons and researchers. Based on these problems, we improved the various properties of medical grade polycaprolactone (PCL) by adding poly(L-lactide) (PLLA). We produced PCL/PLLA strapping bands with different mass ratios by injection molding. We compared the mechanical properties, degradation properties, cell biocompatibility, bone marrow mesenchymal stem cells (BMSCs) adhesion, proliferation, osteogenic differentiation and fracture fixation effect of these strapping bands. The results showed that the tensile strength and yield force of the strapping bands increased with the increase of the content of PLLA. The addition of PLLA could significantly improve the mechanical strength in the early stage and accelerate the degradation rate of the strapping band. PCL/PLLA (80/20) strapping band had no significant cytotoxicity toward rBMSCs and could promote osteogenic differentiation of rBMSCs. The strapping band could ensure femoral fracture healing of beagles in 3 months and didn't cause damage to the surrounding tissues and main organs. This study will provide some new insights into the biodegradable products of PCL/PLLA blends for internal fixation of fracture. We produced novel degradable PCL/PLLA strapping bands with different mass ratios by injection molding. We tested the biological safety of the prepared internal fixation strapping bands for fracture, such as cell experiment in vitro and animal experiment, and studied the degradation behavior in vitro. The strapping bands could ensure femoral fracture healing of beagles. This study will provide some new insights into the biodegradable products of PCL/PLLA blends for internal fixation of fracture. A Immunofluorescence staining of rBMSCs (live cells: green; dead cells: red). B Young's modulus change curve during strapping bands degradation. C The implantation process of strapping bands. D Micro-CT images of the beagle's fracture recovery after the operation.


Asunto(s)
Fracturas del Fémur , Osteogénesis , Animales , Perros , Humanos , Fijación Interna de Fracturas , Fracturas del Fémur/cirugía , Curación de Fractura , Materiales Biocompatibles
8.
J Arthroplasty ; 38(7S): S285-S291, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37086930

RESUMEN

BACKGROUND: Fracture of contemporary femoral stems is a rare occurrence in total hip arthroplasty. A knowledge gap remains regarding manufacturing, patient, and surgeon factors that may contribute to the increased risk of this complication. METHODS: We analyzed 13 contemporary fractured porous-coated femoral stems of various designs to determine cause and contributing factors of mechanical failure. Cases included 12 men and 1 woman who had an average age at index surgery of 53 years (range, 34 to 76 years). There were 10 of 13 patients who had a body mass index more than 30 (obese); 3 of the 10 had a body mass index more than 40. The mean time to fracture was 7.6 years (range, 7 months to 12 years). RESULTS: There were 4 titanium alloy stems that fractured an average of 3.6 years postrevision surgery for head/cup exchange and had associated iatrogenic mechanical and electrocautery damage to the femoral neck at fracture initiation sites. There were 6 modular stems that failed at the stem-sleeve or stem-neck interfaces with evidence of fretting corrosion. For 2 stem-neck fractures, mismatched head/stem combinations from different manufacturers resulted in untested mechanical offsets and loading. There were 2 proximal neck fractures and 1 mid-shaft fracture of coated cobalt-chromium alloy stems that occurred in 3 obese men. The neck fractures (10 to 12 years) were well-fixed stems. Lack of proximal fixation contributed to the mid-shaft fracture (7 months). CONCLUSION: While rare, femoral stem fractures pose catastrophic outcomes in primary and revision total hip arthroplasty. Manufacturing, patient, and surgical factors contributing to stem failures were identified, including patient obesity, heat-treatment reduction of mechanical properties, iatrogenic implant damage, and mixing of different vendor stems and heads.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Masculino , Femenino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Prótesis de Cadera/efectos adversos , Diseño de Prótesis , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Aleaciones de Cromo , Fracturas del Fémur/epidemiología , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Reoperación , Obesidad/complicaciones , Enfermedad Iatrogénica , Falla de Prótesis
9.
J Arthroplasty ; 38(9): 1787-1792, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36805114

RESUMEN

BACKGROUND: Despite concerns for corrosion, dislocation, and periprosthetic femur fractures, minimal literature has investigated the effect of adjusting femoral head length on outcomes after primary total hip arthroplasty (THA). Therefore, we aimed to investigate the effect of femoral head length on the risk of any revision and reoperation following cobalt chromium (CoCr)-on-highly crosslinked polyethylene (HXLPE) THAs. METHODS: Between 2004 and 2018, we identified 1,187 primary THAs with CoCr-on-HXLPE articulations using our institutional total joint registry. The mean age at THA was 71 years (range, 19-97), 40% were women, and mean body mass index was 30 (range, 10-68). All THAs using 36 mm diameter femoral heads were included. Neutral (0 mm), positive, or negative femoral head lengths were used in 42, 31, and 27% of the THAs, respectively. Kaplan-Meier survivorship was assessed. The mean follow-up was 7 years (range, 2-16). RESULTS: The 10-year survivorships free of any revision or reoperation were 94 and 92%, respectively. A total of 47 revisions were performed, including periprosthetic femur fracture (17), periprosthetic joint infection (8), dislocation (7), aseptic loosening of either component (6), corrosion (4), and other (5). Nonrevision reoperations included wound revision (11), open reduction and internal fixation of periprosthetic femur fracture (4), and abductor repair (2). Multivariable analyses found no significant associations between femoral head length and revision or reoperation. CONCLUSION: Altering femoral head lengths in 36 mm CoCr-on-HXLPE THAs did not affect outcomes. Surgeons should select femoral head lengths that optimize hip stability and center of rotation. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Luxaciones Articulares , Fracturas Periprotésicas , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Polietileno , Cabeza Femoral/cirugía , Falla de Prótesis , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Luxaciones Articulares/cirugía , Reoperación , Aleaciones de Cromo , Fracturas del Fémur/cirugía , Diseño de Prótesis , Cromo , Cobalto
10.
Arch Orthop Trauma Surg ; 143(5): 2341-2353, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35414129

RESUMEN

INTRODUCTION: Temporary spacers used in the staged revision of a hip prosthetic joint infection (PJI) have been associated with several mechanical complications with very variable reported general complications rates up to 73%. The aim of this systematic review was to assess the mechanical complications associated with hip antibiotic-loaded spacers when treating periprosthetic hip PJI. METHODS: Through an electronic systematic search of PubMed, articles reporting mechanical complications of spacers used in the treatment of hip PJI were reviewed. Dislocations, spacer fracture, femoral fractures, and acetabular lysis rates were evaluated. RESULTS: Forty studies were included. Standardized molded spacers had a significantly higher weighted mean of total mechanical complication rates (37.2%) when compared to standardized preformed spacers (13.8%, p = 0.039), while no significant difference was found between molded spacers and manually shaped spacers. Spacer dislocation was the most frequent complication. No significant difference in mechanical complication rate was found between spacers with and without any metallic component. CONCLUSIONS: Spacer placement in chronic PJI of the hip with bone and soft-tissue defects is challenging and bears a high risk of mechanical failures and progressive bone loss during the interim period. A careful patient selection for spacer implantation is mandatory.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Humanos , Antibacterianos , Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Cementos para Huesos , Fracturas del Fémur/complicaciones , Luxaciones Articulares/etiología , Infecciones Relacionadas con Prótesis/cirugía , Reoperación/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
11.
Eur J Orthop Surg Traumatol ; 33(5): 1629-1633, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35788424

RESUMEN

OBJECTIVE: To determine if screw fixation across a cement mantle is safe and effective during plate fixation of well-fixed periprosthetic femur fractures. DESIGN: Retrospective cohort study. SETTING: Academic Level I Trauma Center. PATIENTS: Twenty-eight patients with AO/OTA 32A[B1] or 32A[C] periprosthetic femur fractures treated with open reduction and internal plate and screw fixation after cemented or uncemented hip arthroplasty. INTERVENTION: Screw placement into the cement mantle during internal fixation. OUTCOME MEASUREMENTS: Primary outcome was revision arthroplasty for aseptic loosening. Secondary outcomes included radiographic evidence of aseptic loosening, infection, nonunion, implant failure, and overall reoperation rate. RESULTS: There were 28 patients who met inclusion criteria. A total of 9 patients had screws placed in the cement mantle while the remaining 19 patients had screws placed around an uncemented stem. At a mean of 3.7-year follow-up, there were no cases of revision arthroplasty or aseptic loosening in either group. There were no significant differences in rates of infection, nonunion, implant failure, or reoperation rate between patients who had screw placement into a cement mantle vs around an uncemented stem. CONCLUSION: Drilling into the cement mantle during fixation of a periprosthetic femur fracture around a well-fixed cemented hip stem appears safe and effective. When possible, surgeons can consider bicortical screws around a cemented stem, given the biomechanical advantages over unicortical screw or cerclage fixation. Larger prospective trials confirming the safety of this technique are warranted prior to routine implementation. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Estudios Prospectivos , Estudios Retrospectivos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Reoperación/efectos adversos , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Cementos para Huesos/efectos adversos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fémur/cirugía
12.
J Bone Miner Metab ; 40(2): 275-291, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35041084

RESUMEN

INTRODUCTION: This real-world study evaluated whether long-term use of eldecalcitol (ELD) increases the risk of adverse events (AEs), namely, hypercalcemia, acute kidney injury (AKI), and urolithiasis, and analyzed the ELD-induced risk of rare AEs such as osteonecrosis of the jaw (ONJ) and atypical femoral fracture (AFF). MATERIALS AND METHODS: Patient records were retrieved from Medical Data Vision (MDV) and Japan Medical Data Center (JMDC) databases. The ELD-treated osteoporosis patient cohort (ELD cohort) was analyzed to determine the incidence rate of the aforementioned AEs. The patient cohort that was prescribed active vitamin D3 other than ELD (AVD cohort) was analyzed as the reference. RESULTS: Incidence rates of hypercalcemia, AKI, and urolithiasis in the ELD cohort were 0.942, 0.517, 2.465 events per 100 person-years, respectively, in the MDV dataset, and 0.687, 0.155, 3.785, respectively, in the JMDC dataset. The incidence rates of these AEs in the ELD cohort remained relatively constant throughout ELD treatment. A small number of patients experienced ONJ or AFF during ELD or AVD treatment. The number of ONJ and AFF cases in the both cohorts decreased over time. The two cohorts showed no difference in the concomitant use of anti-bone resorptive agents such as bisphosphonates and denosumab. CONCLUSION: The risk of hypercalcemia and AKI associated with ELD use observed in this retrospective analysis is similar to that reported previously in the Japanese post-marketing surveillance of ELD. Furthermore, ELD, similar to AVD, may not increase the risk of ONJ and AFF.


Asunto(s)
Conservadores de la Densidad Ósea , Osteoporosis , Vitamina D , Lesión Renal Aguda/inducido químicamente , Osteonecrosis de los Maxilares Asociada a Difosfonatos , Conservadores de la Densidad Ósea/efectos adversos , Difosfonatos/efectos adversos , Fracturas del Fémur , Humanos , Hipercalcemia/inducido químicamente , Japón/epidemiología , Osteoporosis/tratamiento farmacológico , Osteoporosis/epidemiología , Estudios Retrospectivos , Urolitiasis/inducido químicamente , Vitamina D/efectos adversos , Vitamina D/análogos & derivados
13.
BMC Surg ; 22(1): 354, 2022 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-36192727

RESUMEN

BACKGROUND: The stability of the Hoffa fracture fixed with a cannulated screw is limited. In the present work, we adopted two cannulated screws from anterior to posterior and posteriorly anti-gliding plate to treat 12 cases with Hoffa fracture of the lateral femoral condyle. METHODS: Open reduction and internal fixation were performed in 12 patients with Hoffa fractures of the lateral femoral condyle. The Hoffa fracture end was fixed with an anti-gliding steel plate based on cannulated screw fixation in the rear of the distal femur. All patients were followed for 12-24 months, with a median of 15.3 ± 4.6 months. RESULTS: All fractures were bony union, with a healing time of 3-6 months (median, 4.5 months). The Letenneur evaluation system was used to assess efficacy. Four indexes were observed, including knee range of motion (ROM), stability, pain, and dependent ambulation. The results revealed that eight cases were excellent and four cases good, with a good rate of 100%. CONCLUSION: The surgical treatment with cannulated screws in combination with an anti-gliding steel plate could fix the end of the Hoffa fracture, which could acquire strong internal fixation and a good curative effect.


Asunto(s)
Fracturas del Fémur , Placas Óseas , Huesos , Fracturas del Fémur/cirugía , Fémur/cirugía , Fijación Interna de Fracturas/métodos , Humanos , Acero , Resultado del Tratamiento
14.
Arch Orthop Trauma Surg ; 142(6): 1039-1046, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33575925

RESUMEN

INTRODUCTION: Periprosthetic femoral fractures (PFF) are detrimental for patients. Vancouver B2 fractures about a cemented stem can be revised to a longer uncemented stem or using an in-cement revision, if the cement mantle is adequate. There are reports documenting the success of both techniques. The aim of this single centre study was to perform a direct comparison of these two procedures. MATERIALS AND METHODS: A retrospective study of consecutive Vancouver B2 PFFs around a cemented stem during 16 years was performed. All study cases were treated either using an in-cement revision or with an uncemented stem revision. Preoperatively, the groups were compared based upon age, gender, ASA, BMI, and Charlson comorbidity score. The outcome measures were surgical time, complications, in-hospital stay, revisions, 1-year readmission rate, and survivorship. RESULTS: After a median of 3.5 years, there were 70 patients in the uncemented and 31 in the in-cement group. There was no difference in any of the preoperative variables. Surgical time was shorter for in-cement revisions by a mean of 45 min (p < 0.001). There was no difference in in-hospital stay, surgical complications or readmissions. Implant survival at 5 years was 93.5% for the in-cement and 94.4% for the uncemented revision (p = 0.946). Patient survivorship at 5 years was 62.5% for the in-cement and 69.8% for the uncemented group (p = 0.094). CONCLUSIONS: This study demonstrates that in-cement revision is a valid treatment option for Vancouver B2 fractures, comparable to uncemented stem revision, if certain criteria are met. There was no difference in revision rate, patient survivorship, complications, readmissions or in-hospital stay.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Cementos para Huesos , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Reoperación/efectos adversos , Estudios Retrospectivos
15.
Arch Orthop Trauma Surg ; 142(11): 3221-3228, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34390386

RESUMEN

INTRODUCTION: The aim of this study was to identify factors associated with the level of periprosthetic fracture involving a cemented polished tapered stem: Vancouver B or Vancouver C. METHODS: A retrospective cohort study of 181 unilateral periprosthetic fractures involving Exeter stems was assessed by three observers (mean age 78.5, range 39-103; mean BMI 27.1, 17-39; 97 (54%) male). Patient demographics, deprivation scores, BMI and time since primary prosthesis were recorded. Femoral diameter, femoral cortical thickness, Dorr classification and distal cement mantle length were measured from calibrated radiographs. Interobserver reliability was calculated using intraclass correlation coefficients (ICCs). Univariate and multivariate analysis was performed to identify associations with Vancouver B or C fractures. RESULTS: 160/181 (88%) Vancouver B and 21/181 (12%) Vancouver C-level fractures occurred at a mean of 5.9 ± 5.4 years (0.2-26.5) following primary surgery. Radiographic measurements demonstrated excellent agreement (ICC > 0.8, p < 0.001). Mortality was significantly higher following Vancouver C compared to B fractures: 90 day 14/160 Vs 5/21 (p = 0.05); 1 year 29/160 Vs 8/21 (p = 0.03). Univariate analysis demonstrated that Vancouver C fractures were associated with female sex, bisphosphonate use, cortical bone thickness, and distal cement mantle length (p < 0.05). On multivariate analysis, only female sex was an independent predictor of Vancouver C-level fractures (R2 =0.354, p = 0.005). CONCLUSION: Most PFFs involving the Exeter stem design are Vancouver B-type fractures and appear to be independent of osteoporosis. In contrast, Vancouver C periprosthetic fractures display typical fragility fracture characteristics and are associated with female sex, thinner femoral cortices, longer distal cement mantles and high mortality.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Anciano , Cementos para Huesos , Difosfonatos , Femenino , Fracturas del Fémur/cirugía , Humanos , Masculino , Fracturas Periprotésicas/diagnóstico por imagen , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Reoperación , Reproducibilidad de los Resultados , Estudios Retrospectivos
16.
Acta Chir Orthop Traumatol Cech ; 89(2): 150-157, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35621407

RESUMEN

PURPOSE OF THE STUDY Cementless stems in highly dysplastic hips are considered to increase the risk of femoral fracture and associated morbidity. Several authors speculated to use prophylactic cabling in this patient group to prevent intraoperative fractures. This study aims to reveal objective results regarding the perioperative complications in a large and consecutive patient group with respect to use of prophylactic cabling. MATERIAL AND METHODS A retrospective comparative study was planned. A total of 122 consecutive patients with dysplastic hips of Crowe type 3 or 4, operated on with total hip arthroplasty (THA) and shortening osteotomy using a rectangular femoral stem were included. Patients were stratified according to use of a diaphyseal prophylactic cerclage cable. Perioperative complications were recorded. Clinical outcome was measured in terms of Harris Hip Score and Visual Analog Scale (VAS) for pain. All results were compared between the groups. RESULTS The mean follow-up time was 27 months. Two (2%) versus five (14%) patients had a fracture at the diaphyseal level in cabled versus non-cabled groups. Difference between groups was statistically significant (p=0.01). Relative risk of fracture in case of a non-cabling was 5.8 (p=0.03). Eleven (9%) patients had a non-displaced fracture at the metaphyseal level. No significant differences were detected with respect to preoperative clinical outcome scores or change in these scores between groups. CONCLUSIONS Femoral diaphyseal fracture rates are low when cementless, rectangular stems are used in dysplastic high riding hips. Prophylactic cerclage cabling further decreases the fracture risk and eases treatment in case of a fracture without causing additional complications and therefore is recommended. Key words: intraoperative fracture, periprosthetic fracture, total hip arthroplasty, cerclage cabling, developmental hip dysplasia, transverse shortening osteotomy.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Displasia del Desarrollo de la Cadera , Fracturas del Fémur , Fracturas Periprotésicas , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Cementos para Huesos , Fracturas del Fémur/etiología , Fracturas del Fémur/prevención & control , Fracturas del Fémur/cirugía , Humanos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/prevención & control , Fracturas Periprotésicas/cirugía , Estudios Retrospectivos
17.
Medicina (Kaunas) ; 58(10)2022 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-36295475

RESUMEN

Hip fractures are a leading cause of hospitalisation in elderly patients, representing an increasing socioeconomic problem arising from demographic changes, considering the increased number of elderly people in our countries. Adequate peri-operative treatment is essential to decrease mortality rates and avoid complications. Modern management should involve a coordinated multidisciplinary approach, early surgery, pain treatment, balanced fluid therapy, and prevention of delirium, to improve patients' functional and clinical outcomes. The operative treatment for intertrochanteric and subtrochanteric fractures is intramedullary nail or sliding/dynamic hip screw (DHS) on the basis of the morphology of the fracture. In the case of neck fractures, total hip replacement (THR) or hemiarthroplasty are recommended. However, several topics remain debated, such as the optimum thromboprophylaxis to reduce venous thromboembolism or the use of bone cement. Postoperatively, patients can benefit from early mobilisation and geriatric multidisciplinary care. However, during the COVID-19 pandemic, a prolonged time to operation with a subsequent increased complication rate have burdened frail and elderly patients with hip fractures. Future studies are needed with the aim to investigate better strategies to improve nutrition, postoperative mobility, to clarify the role of home-based rehabilitation, and to identify the ideal analgesic treatment and adequate tools in case of patients with cognitive impairment.


Asunto(s)
COVID-19 , Fracturas del Fémur , Fracturas de Cadera , Tromboembolia Venosa , Humanos , Anciano , Clavos Ortopédicos , Cementos para Huesos , Anticoagulantes , Pandemias , Fracturas de Cadera/cirugía , Resultado del Tratamiento
18.
FASEB J ; 34(4): 5673-5687, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32115776

RESUMEN

Surface chemistry and mechanical stability determine the osteogenic capability of bone implants. The development of high-strength bioactive scaffolds for in-situ repair of large bone defects is challenging because of the lack of satisfying biomaterials. In this study, highly bioactive Ca-silicate (CSi) bioceramic scaffolds were fabricated by additive manufacturing and then modified for pore-wall reinforcement. Pure CSi scaffolds were fabricated using a direct ink writing technique, and the pore-wall was modified with 0%, 6%, or 10% Mg-doped CSi slurry (CSi, CSi-Mg6, or CSi-Mg10) through electrostatic interaction. Modified CSi@CSi-Mg6 and CSi@CSi-Mg10 scaffolds with over 60% porosity demonstrated an appreciable compressive strength beyond 20 MPa, which was ~2-fold higher than that of pure CSi scaffolds. CSi-Mg6 and CSi-Mg10 coating layers were specifically favorable for retarding bio-dissolution and mechanical decay of scaffolds in vitro. In-vivo investigation of critical-size femoral bone defects repair revealed that CSi@CSi-Mg6 and CSi@CSi-Mg10 scaffolds displayed limited biodegradation, accelerated new bone ingrowth (4-12 weeks), and elicited a suitable mechanical response. In contrast, CSi scaffolds exhibited fast biodegradation and retarded new bone regeneration after 8 weeks. Thus, tailoring of the chemical composition of pore-wall struts of CSi scaffolds is beneficial for enhancing the biomechanical properties and bone repair efficacy.


Asunto(s)
Materiales Biocompatibles/química , Huesos/citología , Compuestos de Calcio/química , Fracturas del Fémur/terapia , Osteogénesis , Silicatos/química , Ingeniería de Tejidos , Andamios del Tejido , Animales , Cerámica/química , Fracturas del Fémur/etiología , Fracturas del Fémur/patología , Fenómenos Mecánicos , Porosidad , Conejos
19.
BMC Musculoskelet Disord ; 22(1): 1010, 2021 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-34856965

RESUMEN

BACKGROUND: There are concerns regarding initial stability and cutout effect in proximal femoral nail antirotation (PFNA) treating intertrochanteric fractures. No study have used finite element analysis (FEA) to investigate the biomechanics. This study aimed to compare the cutout effect, stress and displacement between stable (AO31-A1.3) and unstable (AO31-A2.2) intertrochanteric fractures treated by cement augmented PFNA. METHODS: Four femoral finite element models (FEMs) were constructed and tested under the maximum loading during walking. Non-augmented and augmented PFNA in two different intertrochanteric fractures were respectively simulated, assuming Tip Apex Distance (TAD) < 25 mm within each FEM. The cutout effect, stress and displacement between femur and PFNA were compared in each condition. RESULTS: Cutout effect was observed in both non-augmented femoral head and was more apparently in unstable intertrochanteric fracture model. After reinforced by bone cement, no cutout effect occurred in two models. Stress concentration were observed on medial part of intertrochanteric region and the proximal part of helical blade before augmented while were observed on femoral shaft and the conjunction between blade and nail after augmented in both FEMs. Displacement mainly appeared on femoral head and the helical blade tip before augmented while distributed moderately on intertrochanteric region and the upper part of nail after augmented in both FEMs. The maximum stress and displacement value of femur decreased both in stable and unstable model after augmented but was more significantly in the unstable one. The maximum stress and displacement value of PFNA increased both in stable and unstable model after augmented but was more significantly in the unstable one. CONCLUSION: Our FEA study indicated that the cement augmentation of the PFNA biomechanically enhances the cutout resistance in intertrochanteric fracture, this procedure is especially efficient for the unstable intertrochanteric fracture.


Asunto(s)
Fracturas del Fémur , Fijación Intramedular de Fracturas , Fracturas de Cadera , Cementos para Huesos , Clavos Ortopédicos , Fémur , Análisis de Elementos Finitos , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/cirugía , Humanos , Resultado del Tratamiento
20.
Proc Natl Acad Sci U S A ; 115(50): E11741-E11750, 2018 12 11.
Artículo en Inglés | MEDLINE | ID: mdl-30478052

RESUMEN

A comprehensive understanding of the key microenvironmental signals regulating bone regeneration is pivotal for the effective design of bioinspired orthopedic materials. Here, we identified citrate as an osteopromotive factor and revealed its metabonegenic role in mediating citrate metabolism and its downstream effects on the osteogenic differentiation of human mesenchymal stem cells (hMSCs). Our studies show that extracellular citrate uptake through solute carrier family 13, member 5 (SLC13a5) supports osteogenic differentiation via regulation of energy-producing metabolic pathways, leading to elevated cell energy status that fuels the high metabolic demands of hMSC osteodifferentiation. We next identified citrate and phosphoserine (PSer) as a synergistic pair in polymeric design, exhibiting concerted action not only in metabonegenic potential for orthopedic regeneration but also in facile reactivity in a fluorescent system for materials tracking and imaging. We designed a citrate/phosphoserine-based photoluminescent biodegradable polymer (BPLP-PSer), which was fabricated into BPLP-PSer/hydroxyapatite composite microparticulate scaffolds that demonstrated significant improvements in bone regeneration and tissue response in rat femoral-condyle and cranial-defect models. We believe that the present study may inspire the development of new generations of biomimetic biomaterials that better recapitulate the metabolic microenvironments of stem cells to meet the dynamic needs of cellular growth, differentiation, and maturation for use in tissue engineering.


Asunto(s)
Ácido Cítrico/metabolismo , Células Madre Mesenquimatosas/metabolismo , Adenosina Trifosfato/metabolismo , Animales , Materiales Biocompatibles/química , Biopolímeros/química , Regeneración Ósea/fisiología , Adhesión Celular , Diferenciación Celular/fisiología , Proliferación Celular , Modelos Animales de Enfermedad , Fracturas del Fémur/patología , Fracturas del Fémur/terapia , Humanos , Masculino , Células Madre Mesenquimatosas/citología , Redes y Vías Metabólicas , Modelos Biológicos , Osteogénesis/fisiología , Fenotipo , Fosfoserina/metabolismo , Ratas , Ratas Sprague-Dawley , Fracturas Craneales/patología , Fracturas Craneales/terapia , Nicho de Células Madre/fisiología , Simportadores/metabolismo , Ingeniería de Tejidos , Andamios del Tejido/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA