Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Surg Endosc ; 32(3): 1600-1606, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28791559

RESUMEN

BACKGROUND: Laparoscopic lens fogging (LLF) hampers vision and impedes operative efficiency. Attempts to reduce LLF have led to the development of various anti-fogging fluids and warming devices. Limited literature exists directly comparing these techniques. We constructed a model peritoneum to simulate LLF and to compare the efficacy of various anti-fogging techniques. MATERIALS AND METHODS: Intraperitoneal space was simulated using a suction bag suspended within an 8 L container of water. LLF was induced by varying the temperature and humidity within the model peritoneum. Various anti-fogging techniques were assessed including scope warmers, FREDTM, ResoclearTM, chlorhexidine, betadine and immersion in heated saline. These products were trialled with and without the use of a disposable scope warmer. Vision scores were evaluated by the same investigator for all tests and rated according to a predetermined scale. Fogging was assessed for each product or technique 30 times and a mean vision rating was recorded. RESULTS: All products tested imparted some benefit, but FREDTM performed better than all other techniques. Betadine and ResoclearTM performed no better than the use of a scope warmer alone. Immersion in saline prior to insertion resulted in decreased vision ratings. The robotic scope did not result in LLF within the model. CONCLUSIONS: In standard laparoscopes, the most superior preventative measure was FREDTM utilised on a pre-warmed scope. Despite improvements in LLF with other products FREDTM was better than all other techniques. The robotic laparoscope performed superiorly regarding LLF compared to standard laparoscope.


Asunto(s)
Laparoscopios/normas , Laparoscopía/instrumentación , Lentes/normas , Procedimientos Quirúrgicos Robotizados/instrumentación , Clorhexidina/administración & dosificación , Desinfectantes/administración & dosificación , Calor , Humanos , Humedad , Modelos Biológicos , Peritoneo , Povidona Yodada/administración & dosificación , Solución Salina/administración & dosificación , Temperatura
2.
Surg Endosc ; 32(3): 1593-1599, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28643058

RESUMEN

BACKGROUND: The FloShield Air System® is a new device for laparoscopic surgery that utilizes a continuous dry CO2 gas flow over the scope to defog the lens and protect it from condensation, debris and smoke. We set out to compare the performance and efficiency of the device in terms of operative lens vision quality (OLVQ) with the reference technique (water + povidone-iodine (PVI) solution) during gynecologic laparoscopic surgery. MATERIALS AND METHODS: We conducted a single-center randomized prospective study between March and June 2016 (Trials Database Registration NCT02702531) including 53 patients undergoing gynecologic laparoscopic surgery with water + PVI solution and 51 patients who underwent surgical procedures with the FloShield Air System. The primary outcome measure was the number of laparoscope removals during surgery. Secondary outcome measures were the time to clean, assessment of the quality of vision, the correlation between the laparoscopic surgical complexity and outcomes, and cost effectiveness. RESULTS: Overall, the mean patient age was 43.2 years (range 22-86) and body mass index 24.8 (range 16.8-42.7). The mean number of endoscope removals during surgery was 7.0 (range 0-37) in the water + PVI solution arm and 2.8 (range 0-12) in the FloShield Air System® arm. The number of removals was significantly lower in the FloShield arm (p < 0.001). No difference in time to clean, quality of vision, level of laparoscopic procedure complexity, or cost was observed between the groups. CONSLUSIONS: The FloShield Air System® resulted in fewer laparoscopic lens removals than the water + PVI solution solution, but that there was no difference in quality of vision, cleaning time or cost, especially for the more complex surgery.


Asunto(s)
Procedimientos Quirúrgicos Ginecológicos/instrumentación , Laparoscopios/normas , Laparoscopía/instrumentación , Lentes/normas , Adulto , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Dióxido de Carbono , Costos y Análisis de Costo , Femenino , Procedimientos Quirúrgicos Ginecológicos/economía , Procedimientos Quirúrgicos Ginecológicos/métodos , Humanos , Laparoscopía/economía , Laparoscopía/métodos , Persona de Mediana Edad , Povidona Yodada/administración & dosificación , Estudios Prospectivos , Soluciones , Agua/administración & dosificación , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA