1.
Anal Chem ; 96(25): 10459-10466, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38866706

RESUMEN

Exosomes, as an emerging biomarker, have exhibited remarkable promise in early cancer diagnosis. Here, a highly sensitive, selective, and automatic electrochemiluminescence (ECL) method for the detection of cancerous exosomes was developed. Specific aptamer-(EK)4 peptide-tagged magnetic beads (MBs-(EK)4-aptamer) were designed as a magnetic capture probe in which the (EK)4 peptide was used to reduce the steric binding hindrance of cancerous exosomes with a specific aptamer. One new universal ECL signal nanoprobe (CD9 Ab-PEG@SiO2ϵRu(bpy)32+) was designed and synthesized by using microporous SiO2 nanoparticles as the carrier for loading ECL reagent Ru(bpy)32+, polyethylene glycol (PEG) layer, and anticluster of differentiation 9 antibody (CD9 Ab). A "sandwich" biocomplex was formed on the surface of the magnetic capture probe after mixing the capture probe, target exosomes, and ECL signal nanoprobe, and then it was introduced into an automated ECL analyzer for rapid and automatic ECL measurement. It was found that the designed signal nanoprobe shows a 270-fold improvement in the signal-to-noise ratio than that of the ruthenium complex-labeled CD9 antibody signal probe. The relative ECL intensity was proportional to MCF-7 exosomes as a model in the range of 102 to 104 particle/µL, with a detection limit of 11 particle/µL. Furthermore, the ECL method was employed to discriminate cancerous exosomes based on fingerprint responses using the designed multiple magnetic capture probes and the universal ECL signal nanoprobe. This work demonstrates that the utilization of a designed automated ECL tactic using the MBs-(EK)4-aptamer capture probe and the CD9 Ab-PEG@SiO2ϵRu(bpy)32+ signal nanoprobe will provide a unique and robust method for the detection and discrimination of cancerous exosomes.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Electroquímicas , Exosomas , Mediciones Luminiscentes , Humanos , Exosomas/química , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Mediciones Luminiscentes/métodos , Células MCF-7 , Dióxido de Silicio/química , Técnicas Biosensibles/métodos , Tetraspanina 29/análisis , Polietilenglicoles/química
2.
Biosens Bioelectron ; 258: 116349, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38705072

RESUMEN

Detection of cancer-related exosomes in body fluids has become a revolutionary strategy for early cancer diagnosis and prognosis prediction. We have developed a two-step targeting detection method, termed PS-MIPs-NELISA SERS, for rapid and highly sensitive exosomes detection. In the first step, a phospholipid polar site imprinting strategy was employed using magnetic PS-MIPs (phospholipids-molecularly imprinted polymers) to selectively isolate and enrich all exosomes from urine samples. In the second step, a nanozyme-linked immunosorbent assay (NELISA) technique was utilized. We constructed Au/Na7PMo11O39 nanoparticles (NPs) with both surface-enhanced Raman scattering (SERS) property and peroxidase catalytic activity, followed by the immobilization of CD9 antibodies on the surface of Au/Na7PMo11O39 NPs. The Au/Na7PMo11O39-CD9 antibody complexes were then used to recognize CD9 proteins on the surface of exosomes enriched by magnetic PS-MIPs. Lastly, the high sensitivity detection of exosomes was achieved indirectly via the SERS activity and peroxidase-like activity of Au/Na7PMo11O39 NPs. The quantity of exosomes in urine samples from pancreatic cancer patients obtained by the PS-MIPs-NELISA SERS technique showed a linear relationship with the SERS intensity in the range of 6.21 × 107-2.81 × 108 particles/mL, with a limit of detection (LOD) of 5.82 × 107 particles/mL. The SERS signal intensity of exosomes in urine samples from pancreatic cancer patients was higher than that of healthy volunteers. This bidirectional MIPs-NELISA-SERS approach enables noninvasive, highly sensitive, and rapid detection of cancer, facilitating the monitoring of disease progression during treatment and opening up a new avenue for rapid early cancer screening.


Asunto(s)
Técnicas Biosensibles , Exosomas , Oro , Espectrometría Raman , Humanos , Exosomas/química , Oro/química , Espectrometría Raman/métodos , Fosfolípidos/química , Fosfolípidos/orina , Límite de Detección , Impresión Molecular , Polímeros Impresos Molecularmente/química , Epítopos/inmunología , Epítopos/química , Nanopartículas del Metal/química , Tetraspanina 29/orina , Tetraspanina 29/análisis , Anticuerpos Inmovilizados/química
3.
Int J Immunopathol Pharmacol ; 25(1): 127-34, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22507325

RESUMEN

It has been established that human dental pulp and periodontal ligament contain a population of mesenchymal stem cells (MSCs). However, the phenotypic analysis in terms of putative stem cell markers expressed by these stem cell populations is incomplete. It is relevant to understand whether stem cells derived from closely related tissues are programmed differently. The aim of the present study is to analyze whether these stem cells depict distinct characteristics by gaining insight into differences in their immunophenotype. Dental pulp and periodontal ligament tissue samples were obtained from extracted impacted wisdom teeth. Cell cultures were analyzed for surface and intracellular markers by indirect immunoflourescence. Detailed immunophenotype analysis was carried out by flow cytometry using relevant markers. The present study data shows dental pulp stem cells (DPSCs) and periodontal ligament stem cells (PDLSCs) expressed embryonic stem (ES) cell markers Oct-4, Nanog and mesodermal marker Vimentin by indirect immunoflourescence. PDLSCs, however, had a weak expression of Nanog. Immunophenotyping revealed strong expression of MSC markers (CD73, CD90) in DPSCs and PDLSCs. Differences were observed in expression of stemness-related markers. DPSCs displayed increased percentages of SSEA4, CD13 and CD166 and decreased CD9 expression compared to PDLSCs. Both stem cells express common MSC markers, different levels of expression suggests there might be more than one stem cell population existing within these tissues which differ in their embryonic status, and DPSCs are a more primitive stem cell population in comparison to PDLSCs.


Asunto(s)
Pulpa Dental/citología , Células Madre Mesenquimatosas/inmunología , Ligamento Periodontal/citología , Adolescente , Adulto , Antígenos CD/análisis , Antígenos CD13/análisis , Moléculas de Adhesión Celular Neuronal/análisis , Células Cultivadas , Proteínas Fetales/análisis , Técnica del Anticuerpo Fluorescente Indirecta , Humanos , Inmunofenotipificación , Tetraspanina 29/análisis , Adulto Joven
4.
J Histochem Cytochem ; 63(3): 181-9, 2015 03.
Artículo en Inglés | MEDLINE | ID: mdl-25473095

RESUMEN

ExoQuick-TC(TM) (EQ), a chemical-based agent designed to precipitate exosomes, was calibrated for use on saliva collected from healthy individuals. The morphological and molecular features of the precipitations were compared with those obtained using the classical, physical-based method of ultracentrifugation (UC). Electron microscopy and immunoelectron microscopy with anti-CD63 showed vesicular nanoparticles surrounded by bi-layered membrane, compatible with exosomes in EQ, similar to that observed with UC. Atomic force microscopy highlighted larger, irregularly shaped/aggregated EQ nanoparticles that contrasted with the single, round-shaped UC nanoparticles. ELISA (performed on 0.5 ml of saliva) revealed a tendency for a higher expression of the specific exosomal markers (CD63, CD9, CD81) in EQ than in UC (p>0.05). ELISA for epithelial growth factor receptor, a non-exosomal-related marker, showed a significantly higher concentration in EQ than in UC (p=0.04). Western blotting of equal total-protein concentrations revealed bands of CD63, CD9 and CD81 in both types of preparations, although they were less pronounced in EQ compared with UC. This may be related to a higher fraction of non-exosomal proteins in EQ. In conclusion, EQ is suitable and efficient for precipitation of salivary exosomes from small volumes of saliva; however, EQ tends to be associated with considerably more biological impurities (non-exosomal-related proteins/microvesicles) as compared with UC.


Asunto(s)
Exosomas/química , Saliva/citología , Tetraspanina 28/análisis , Tetraspanina 29/análisis , Tetraspanina 30/análisis , Adulto , Anciano , Western Blotting , Precipitación Química , Ensayo de Inmunoadsorción Enzimática , Exosomas/ultraestructura , Femenino , Humanos , Masculino , Microscopía de Fuerza Atómica , Microscopía Electrónica , Persona de Mediana Edad , Saliva/química , Ultracentrifugación