Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.268
Filter
Add more filters

Publication year range
1.
J Periodontal Res ; 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38828886

ABSTRACT

AIMS: To test whether titanium surface roughness disparity might be used to specifically guide the behavior of gingiva fibroblasts and keratinocytes, thereby improving the quality of soft tissue (ST) integration around abutments. METHODS: Titanium discs resembling the roughness of enamel (M) or cementum (MA) were created with normal or increased hydrophilicity and used as substrates for human fibroblasts and keratinocytes. Adhesion and proliferation assays were performed to assess cell-type specific responses upon encountering the different surfaces. Additionally, immunofluorescence and qPCR analyses were performed to study more in depth the behavior of fibroblasts and keratinocytes on MA and M surfaces, respectively. RESULTS: While enamel-like M surfaces supported adhesion, growth and a normal differentiation potential of keratinocytes, cementum-emulating MA surfaces specifically impaired the growth of keratinocytes. Vice versa, MA surfaces sustained regular adhesion and proliferation of fibroblasts. Yet, a more intimate adhesion between fibroblasts and titanium was achieved by an increased hydrophilicity of MA surfaces, which was associated with an increased expression of elastin. CONCLUSION: The optimal titanium implant abutment might be achieved by a bimodal roughness design, mimicking the roughness of enamel (M) and cementum with increased hydrophilicity (hMA), respectively. These surfaces can selectively elicit cell responses favoring proper ST barrier by impairing epithelial downgrowth and promoting firm adhesion of fibroblasts.

2.
Support Care Cancer ; 32(5): 295, 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38635051

ABSTRACT

OBJECTIVE: The aim of this in vitro study was to evaluate the effect of radiotherapy on the surface microhardness and roughness of different bioactive restorative materials. MATERIALS AND METHODS: A total of 60-disc specimens (5 mm × 2 mm) were performed in four groups (n = 15 each) from Equia Forte HT, Cention N, Activa Bioactive Restorative, and Beautifil II. Following the polishing procedure (600, 1000, 1200 grit silicon carbide papers), all specimens were irradiated at 2 Gy per fraction, five times a week for a total dose of 70 Gy in 30 fractions over 7 weeks. Before and after the irradiation, the specimens were analyzed regarding the surface roughness and microhardness. Surface morphology was also analyzed by scanning electron microscopy. Kruskal-Wallis test, Wilcoxon test, and paired sample t-test were used for statistical analysis. RESULTS: Significant differences were found after radiation with increased mean roughness of both Cention N (p = 0.001) and Beautifil II (p < 0.001) groups. In terms of microhardness, only the Beautifil II group showed significant differences with decreased values after radiation. There were statistically significant differences among the groups' roughness and microhardness data before and after radiotherapy (p < 0.05). CONCLUSION: The effect of radiotherapy might differ according to the type of the restorative material. Although results may differ for other tested materials, giomer tends to exhibit worse behaviour in terms of both surface roughness and microhardness. CLINICAL RELEVANCE: In patients undergoing head and neck radiotherapy, it should be taken into consideration that the treatment process may also have negative effects on the surface properties of anti-caries restorative materials.


Subject(s)
Dental Caries , Radiation Oncology , Humans , Cariostatic Agents , Neck , Research Design
3.
Eur J Oral Sci ; 132(2): e12967, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38105518

ABSTRACT

The aim of the study was to evaluate the effects of erosion and abrasion on resin-matrix ceramic CAD/CAM materials [CERASMART (GC); VITA ENAMIC (VITA Zahnfabrik); Lava Ultimate (3 M)] in comparison to feldspar ceramic (VITABLOCS Mark II, VITA Zahnfabrik) and resin composite materials (ceram.x universal, Dentsply Sirona). Daily brushing and acid exposure were simulated using a brushing apparatus and a solution of 0.5 vol% citric acid. Microhardness, surface roughness, and substance loss were measured at baseline and after simulation of 1 and 3 years of function. All materials showed a decrease in microhardness after 3 years and an increase in surface roughness (Ra) after 1 and 3 years. The Ra increase was statistically significantly lower for the resin-matrix ceramics than for feldspar ceramic and similar to composite material. After 3 years, only feldspar ceramic showed no significant substance loss. In conclusion, resin-matrix ceramics demonstrate reduced roughening compared to feldspar ceramics, potentially improving restoration longevity by preventing plaque buildup, but differences in abrasion resistance suggest the need for further material-specific research. Future research should aim to replicate clinical conditions closely and to transition to in vivo trials.


Subject(s)
Ceramics , Dental Porcelain , Potassium Compounds , Surface Properties , Materials Testing , Composite Resins , Aluminum Silicates , Computer-Aided Design , Dental Materials
4.
Lasers Med Sci ; 39(1): 162, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38910231

ABSTRACT

The review critically evaluates the current state of studies investigating laser irradiation for modifying titanium surfaces to enhance the biointegration of dental implants. Laser modification is a rapidly evolving physicochemical surface modification process with the potential to revolutionize dental implant technology. A thorough search of electronic databases, including PubMed, Science Direct, MEDLINE, and Web of Knowledge, was conducted to identify relevant articles. The review focuses on the surface features of laser-modified implants, encompassing in vitro cell culture experiments, rare animal experiments, and limited clinical trials. Of the 26 selected sources, 21 describe surface features, while only two involve in vivo human experiments. The review highlights the lack of long-term clinical experience and calls for further research to mature these technologies. Despite the absence of a consensus on optimal laser types and settings, the overall results are promising, with few negative outcomes. As research in laser irradiation of titanium surfaces progresses, significant advancements in dental implant technology and improved patient well-being are anticipated.


Subject(s)
Dental Implants , Lasers , Surface Properties , Titanium , Humans , Animals , Osseointegration
5.
Lasers Med Sci ; 39(1): 217, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39145805

ABSTRACT

This in vitro study aimed to investigate potential changes in the color and roughness of dental enamel resulting from the use of different toothpaste formulations during bleaching with violet LED light (405 nm). Sixty specimens of bovine incisors, each measuring 6 × 6 × 3 mm, were segregated into six distinct experimental groups based on their respective treatments (n = 10): C + VL: Brushing with Colgate® Total 12 + bleaching with violet LED; LB + VL: Brushing with Colgate® Luminous White Brilliant + bleaching with violet LED; LI + VL: Brushing with Colgate® Luminous White Instant + violet LED bleaching; C: Brushing with Colgate® Total 12; LB: Brushing with Colgate® Luminous White Brilliant; LI: Brushing with Colgate® Luminous White Instant. The examined variables included alterations in color (∆L*, ∆a*, ∆b*, ∆Eab, and ∆E00), surface roughness (Ra), and scanning electron microscopy observations. No statistically significant distinctions emerged in total color variations (∆E00 and ∆E) among the groups under scrutiny. Notably, the groups that employed Colgate® Luminous White Instant displayed elevated roughness values, irrespective of their association with violet LED, as corroborated by scanning electron microscopy examinations. It can be concluded that whitening toothpastes associated to violet LED do not influence the color change of dental enamel in fifteen days of treatment. Toothpastes with a higher number of abrasive particles showed greater changes in enamel roughness, regardless of the use of violet LED.


Subject(s)
Color , Dental Enamel , Surface Properties , Tooth Bleaching Agents , Tooth Bleaching , Toothpastes , Dental Enamel/drug effects , Dental Enamel/radiation effects , Cattle , Animals , Toothpastes/chemistry , Tooth Bleaching/methods , Tooth Bleaching/adverse effects , Surface Properties/drug effects , Tooth Bleaching Agents/adverse effects , In Vitro Techniques , Microscopy, Electron, Scanning
6.
Lasers Med Sci ; 39(1): 98, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38583109

ABSTRACT

AIM: The aim of the present study was to evaluate the efficacy of 30°-angled Er:YAG laser tip and different periodontal instruments on root surface roughness and morphology in vitro. METHODS: Eighteen bovine teeth root without carious lesion were decoronated from the cementoenamel junction and seperated longitidunally. A total of 36 obtained blocks were mounted in resin blocks and polished with silicon carbide papers under water irrigation. These blocks were randomly assigned into 3 treatment groups. In Group 1, 30°-angled Er:YAG laser (2.94 µm) tip was applied onto the blocks with a 20 Hz, 120 mJ energy output under water irrigation for 20 s. In Groups 2 and 3, the same treatment was applied to the blocks with new generation ultrasonic tip and conventional curette apico-coronally for 20 s with a sweeping motion. Surface roughness and morphology were evaluated before and after instrumentation with a profilometer and SEM, respectively. RESULTS: After instrumentation, profilometric analysis revealed significantly higher roughness values compared to baseline in all treatment groups(p < 0.05). Laser group revealed the roughest surface morphology followed by conventional curette and new generation ultrasonic tip treatment groups (p < 0.05). In SEM analysis, irregular surfaces and crater defects were seen more frequently in the laser group. CONCLUSION: Results of the study showed that the use of new generation ultrasonic tip was associated with smoother surface morphology compared to 30°-angled Er-YAG laser tip and conventional curette. Further in vitro and in vivo studies with an increased sample size are necessary to support the present study findings.


Subject(s)
Lasers, Solid-State , Animals , Cattle , Lasers, Solid-State/therapeutic use , Research Design , Sample Size , Tooth Cervix , Water
7.
Clin Oral Investig ; 28(5): 294, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38698252

ABSTRACT

OBJECTIVES: To compare ultrasonic scaler prototypes based on a planar piezoelectric transducer with different working frequencies featuring a titanium (Ti-20, Ti-28, and Ti-40) or stainless steel (SS-28) instrument, with a commercially available scaler (com-29) in terms of biofilm removal and reformation, dentine surface roughness and adhesion of periodontal fibroblasts. MATERIALS AND METHODS: A periodontal multi-species biofilm was formed on specimens with dentine slices. Thereafter specimens were instrumented with scalers in a periodontal pocket model or left untreated (control). The remaining biofilms were quantified and allowed to reform on instrumented dentine slices. In addition, fibroblasts were seeded for attachment evaluation after 72 h of incubation. Dentine surface roughness was analyzed before and after instrumentation. RESULTS: All tested instruments reduced the colony-forming unit (cfu) counts by about 3 to 4 log10 and the biofilm quantity (each p < 0.01 vs. control), but with no statistically significant difference between the instrumented groups. After 24-hour biofilm reformation, no differences in cfu counts were observed between any groups, but the biofilm quantity was about 50% in all instrumented groups compared to the control. The attachment of fibroblasts on instrumented dentine was significantly higher than on untreated dentine (p < 0.05), with the exception of Ti-20. The dentine surface roughness was not affected by any instrumentation. CONCLUSIONS: The planar piezoelectric scaler prototypes are able to efficiently remove biofilm without dentine surface alterations, regardless of the operating frequency or instrument material. CLINICAL RELEVANCE: Ultrasonic scalers based on a planar piezoelectric transducer might be an alternative to currently available ultrasonic scalers.


Subject(s)
Biofilms , Dental Scaling , Dentin , Fibroblasts , Periodontal Ligament , Surface Properties , Titanium , Humans , Dental Scaling/instrumentation , In Vitro Techniques , Dentin/microbiology , Periodontal Ligament/cytology , Transducers , Cell Adhesion , Stainless Steel , Equipment Design , Ultrasonic Therapy/instrumentation
8.
Clin Oral Investig ; 28(7): 371, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38869697

ABSTRACT

OBJECTIVES: The purpose of this study is to evaluate the bond strength of different computer-aided design / computer-aided manufacturing (CAD/CAM) hybrid ceramic materials following different pretreatments. METHODS: A total of 306 CAD/CAM hybrid material specimens were manufactured, n = 102 for each material (VarseoSmile Crownplus [VSCP] by 3D-printing; Vita Enamic [VE] and Grandio Blocs [GB] by milling). Each material was randomly divided into six groups regarding different pretreatment strategies: control, silane, sandblasting (50 µm aluminum oxide particles), sandblasting + silane, etching (9% hydrofluorics acid), etching + silane. Subsequently, surface roughness (Ra) values, surface free energy (SFE) were measured. Each specimen was bonded with a dual-cured adhesive composite. Half of the specimens were subjected to thermocycling (5000 cycles, 5-55 °C). The shear bond strength (SBS) test was performed. Data were analyzed by using a two-way analysis of variance, independent t-test, and Mann-Whitney-U-test (α = 0.05). RESULTS: Material type (p = 0.001), pretreatment strategy (p < 0.001), and the interaction (p < 0.001) all had significant effects on Ra value. However, only etching on VSCP and VE surface increased SFE value significantly. Regarding SBS value, no significant difference was found among the three materials (p = 0.937), while the pretreatment strategy significantly influenced SBS (p < 0.05). Etching on VSCP specimens showed the lowest mean value among all groups, while sandblasting and silane result in higher SBS for all test materials. CONCLUSIONS: The bond strength of CAD/CAM hybrid ceramic materials for milling and 3D-printing was comparable. Sandblasting and silane coupling were suitable for both millable and printable materials, while hydrofluoric etching should not be recommended for CAD/CAM hybrid ceramic materials. CLINICAL RELEVANCE: Since comparable evidence between 3D-printable and millable CAD/CAM dental hybrid materials is scarce, the present study gives clear guidance for pretreatment planning on different materials.


Subject(s)
Computer-Aided Design , Crowns , Dental Bonding , Dental Stress Analysis , Materials Testing , Shear Strength , Surface Properties , Dental Bonding/methods , Ceramics/chemistry , Silanes/chemistry , Dental Materials/chemistry , Dental Etching/methods , Dental Porcelain/chemistry , In Vitro Techniques , Humans
9.
Odontology ; 112(2): 408-427, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37792126

ABSTRACT

Zirconia-based dental implants are in direct contact with living tissues and any improvements in their bioactivity and adhesion to the tissues are highly welcome. In this study, different ratios of barium titanate (BT) were added to 3 mol% yttria-stabilized zirconia (3YSZ) through conventional sintering. The laser-texturing technique was also conducted to improve the biological performance of 3YSZ ceramics. The composition and the surface of the prepared composites were characterized by X-ray diffraction and scanning electron microscopy (SEM), respectively. The roughness and surface wettability of the composites were also measured. Furthermore, MC3T3-E1 pre-osteoblast cells were used for the in vitro experiments. Cell viability was evaluated using a commercial resazurin-based method. Morphology and cellular adhesion were observed using SEM. Based on the results, the laser texturing and the barium titanate content influenced the surface characteristics of the prepared composites. The laser-textured 3YSZ/7 mol% BT composites showed a lower water contact angle compared to the other samples, which indicated superior surface hydrophilicity. The cell viability and cell adhesion of 3YSZ/BT composites increased with the rise in the barium titanate content and laser power. An elongated cell morphology and apatite nucleation were also observed by the BT content. Overall, the laser-treated 3YSZ/5 and 7 mol% BT composites may be promising candidates in hard tissue repair due to their good cell response.


Subject(s)
Lasers , Zirconium , Barium , Surface Properties , Wettability
10.
Odontology ; 112(2): 460-471, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37819468

ABSTRACT

The aim of this study was to evaluate the surface roughness and contact angle of composite resins produced by CAD/CAM milling and three-dimensional (3D) printing for permanent restorations as well as the adhesion of S. mutans and S. sanguinis bacteria to these composites. Three CAD/CAM milling composite resins (Vita Enamic-VE, Cerasmart-CE, Lava Ultimate-LU) and three 3D printing resins (Varseo Smile Crown plus-VSC, Saremco print Crowntech-SPC, Formlabs 3B Permanent crown-FLP) were selected. Twenty samples were prepared for each group. Using a contact profilometer, the surface roughness was determined, and an optical goniometer was used to quantify the contact angle. To evaluate the bacterial adhesion, composite specimens were immersed in mucin containing artificial saliva. All samples were incubated for 24 h at 37°C in 5% CO2. CFUs were determined by counting colonies after the incubation period. Surface roughness values of test samples were the highest in the Group VSC [0.46 (0.14) µm], whereas the lowest values were found in the Group LU [0.23 (0.05) µm]. There was no statistically significant difference between the groups in contact angle values (p > 0.05). The S. mutans adhesion extent on the Group SPC was statistically higher compared to all other materials with p < 0.05. For S. sanguinis, the lowest bacterial adhesion value was recorded in Group CE (3.00 × 104 CFU/ml) and statistically significant differences were found with Group VE and VSC (p < 0.05). Different digital manufacturing techniques and material compositions can affect the surface roughnesses of composite resins. All composite resin samples have hydrophobic characteristics. Microbial adhesion of the tested composite resins may be varied depending on the bacterial species. S. mutans showed much more adhesion to these materials than S. sanguinis.


Subject(s)
Bacterial Adhesion , Composite Resins , Composite Resins/chemistry , Surface Properties , Ceramics , Computer-Aided Design , Printing, Three-Dimensional , Materials Testing
11.
J Esthet Restor Dent ; 36(3): 453-459, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37705502

ABSTRACT

OBJECTIVE: To evaluate the effect of coffee thermocycling (CTC) on the surface roughness (Ra ) and stainability of denture base materials with different chemical compositions fabricated by using additive and subtractive manufacturing. MATERIALS AND METHODS: Disk-shaped specimens were additively (FREEPRINT denture, AM) or subtractively (G-CAM, GSM and M-PM, SM) fabricated from three pink denture base materials in different chemical compositions (n = 10). Ra was measured before and after polishing, while color coordinates were measured after polishing. Specimens were subjected to CTC (5000 cycles) and measurements were repeated. Color differences (ΔE00 ) after CTC were calculated. Ra among different time intervals within materials was evaluated by using repeated measures analysis of variance (ANOVA), while 1-way ANOVA was used to evaluate the Ra of different materials within each time interval and the ΔE00 values. Color coordinates within each material were compared by using paired samples t-tests (α = 0.05). RESULTS: Ra before polishing was the highest for all materials (p < 0.001), while SM had its lowest Ra after CTC and AM had its lowest Ra after polishing (p ≤ 0.008). Before polishing, AM had the highest Ra among the materials (p < 0.001). After polishing, SM had higher Ra than AM (p < 0.001). After CTC, GSM had the lowest Ra (p ≤ 0.048). SM had the lowest (p ≤ 0.031) and AM had the highest (p < 0.001) ΔE00 . CTC decreased the a* and b* values of SM and AM (p ≤ 0.017), and increased the L* values of AM (p < 0.001). CONCLUSIONS: Polishing significantly reduced the surface roughness of all materials. CTC did not increase the surface roughness of materials above the clinically acceptable threshold. Only AM had perceptible color change when previously reported threshold values for denture base materials were considered. CLINICAL SIGNIFICANCE: Tested denture base materials may have similar surface stability after coffee thermocycling. However, subtractively manufactured denture base materials may have improved color stability when subjected to long-term coffee consumption.


Subject(s)
Coffee , Denture Bases , Surface Properties , Dental Polishing , Materials Testing , Color
12.
J Esthet Restor Dent ; 36(5): 785-795, 2024 May.
Article in English | MEDLINE | ID: mdl-38130085

ABSTRACT

OBJECTIVES: This laboratory study evaluated the effect of three polishing systems on the surface roughness and gloss of resin composites. MATERIALS AND METHODS: Thirty specimens (6 mm Ø × 8 mm) were fabricated from each of three resin composites: Z 350 XT (nanofill), Harmonize (nanohybrid), and Estelite Omega (supranonofill). All specimens were photopolymerized using a multi-peak LED curing unit (VALO-Standard mode), having a exitance irradiance of approximately 1000 mW/cm2 against a polyester strip (PS). 2 mm was then removed from the irradiated end (finished) using #320 abrasive paper (F). Specimens were then randomly polished (P) using a one-step (1S) (OneGloss), two-step (2S) (EVE Diacomp Twist Basic CA), or 3-step (3S) (Astropol P) system (n = 10). For PS, F, and P groups, surface roughness (Ra) was measured using a surface roughness tester, and surface gloss was measured with a glossmeter. For each specimen, the percent recovery to the PS value (%R) of surface roughness and surface gloss were calculated. Data were analyzed using two-way ANOVA, followed by Tukey's test. Surface roughness and gloss values were submitted to Pearson's correlation test (α = 0.05). All statistical testing was performed using a pre-set alpha of 0.05. RESULTS: The interaction term [resin composite × polishing system] was significant for both surface roughness (p = 0.001) and gloss (p = 0.0001). For all resin composites, the 2S and 3S systems provided a higher %R of surface roughness and gloss compared to those of the 1S system. There was a negative correlation between surface roughness and gloss, but only a few combinations showed strong correlations. CONCLUSIONS: The 2S and 3S polishing systems provided surfaces having greater smoothness and gloss compared to the 1S system. The ability to recover surface roughness and gloss was dependent on type of resin composite filler classification. CLINICAL SIGNIFICANCE: The 3S and 2S polishing systems were more effective in achieving PS values than was the 1S system for all tested resin composites. However, individual polishing systems performed differently depending on type of resin composite.


Subject(s)
Composite Resins , Dental Polishing , Surface Properties , Materials Testing
13.
J Esthet Restor Dent ; 36(3): 484-493, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37933985

ABSTRACT

OBJECTIVE: The effects of four toothpastes on the color stability of in-office bleached tooth specimens were determined. MATERIALS AND METHODS: We evaluated an experimental toothpaste (EXP) and three commercially available toothpastes: Colgate Optic White (OPW), Aquafresh White & Protect (AWP), and Crest 3D White (CDW). OPW, AWP, and CDW contained inorganic abrasives, whereas EXP and AWP contained sodium polyphosphate. Forty-eight randomly selected human-extracted maxillary central incisors were bleached and brushed twice daily over 30 days. We analyzed the final color difference (ΔE*ab, ΔE00 , ΔWID ), arithmetic average surface roughness (Ra) of the enamel measured on days 0 and 30, and scanning electron microscopy images of enamel surfaces and toothpastes. ΔE*ab, ΔE00 , ΔWID , and Ra were analyzed using one-way analysis of variance and Tukey's test (α = 0.05). RESULTS: ΔE*ab and ΔE00 values were significantly lower after toothbrushing with EXP, OPW, and CDW than with AWP. OPW induced the greatest positive ΔWID . Ra was significantly increased by OPW and CDW, but slightly increased by AWP, with cube-like particles, and EXP, with no particle-like structures. CONCLUSIONS: Only EXP stabilized the color of bleached teeth without increasing the enamel surface roughness. Sodium polyphosphate with approximately 10 phosphate groups was effective at removing stains. CLINICAL SIGNIFICANCE: The effect of toothpaste on the color stability of bleached teeth depends on the constituting abrasives and chemical components. Polyphosphoric acid has different stain-removal effects depending on its degree of polymerization. Additionally, although certain types of abrasives may be effective for color stability, they also increase the surface roughness of the enamel.


Subject(s)
Tooth Bleaching , Toothpastes , Humans , Toothpastes/pharmacology , Toothpastes/analysis , Toothpastes/chemistry , Coloring Agents/analysis , Coloring Agents/pharmacology , Dental Enamel/chemistry , Tooth Bleaching/methods , Toothbrushing/methods , Polyphosphates/pharmacology , Polyphosphates/analysis , Sodium/analysis , Sodium/pharmacology , Color
14.
J Esthet Restor Dent ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963682

ABSTRACT

OBJECTIVE: To evaluate the effect of the deterioration of computer aided design/computer aided manufacturing (CAD/CAM) burs during zirconia milling, on surface roughness, contact angle, and fibroblast viability. MATERIALS AND METHODS: Ceramic blocks were milled and 75 ceramic disks (8 × 1.5 mm) made and allocated into three groups (n = 25): G1-brand new 2L and 1L burs, G2-2L bur at the end of lifetime and brand new 1L bur and G3-both burs at the end of their lifetimes. Roughness (Ra, Rq, and Rz) was evaluated using a 3D optical profilometer, the contact angle by the sessile drop method and the cell viability of the mouse NIH/3T3 fibroblast, using the Alamar Blue assay at intervals of 24, 48, and 72 h (ISO 10993-5). Data were analyzed by one-way ANOVA and Kruskal-Wallis tests (p ≤ 0.05). RESULTS: Roughness increased as the burs deteriorated and G3 (0.27 ± 0.04) presented a higher value for Ra (p < 0.001). The highest contact angle was observed in G3 (86.2 ± 2.66) when compared with G1 (63.7 ± 12.49) and G2 (75.3 ± 6.36) (p < 0.001). Alamar Blue indicated an increase in cell proliferation, with no significant differences among the groups at 24 and 72 h (p > 0.05). CONCLUSIONS: The deterioration of the burs increased the surface roughness and decreased the wettability, but did not interfere in cell viability and proliferation. CLINICAL SIGNIFICANCE: The use of custom zirconia abutments represents an effective strategy for single crowns restorations. Our findings suggest that these abutments can be efficiently milled using CAD/CAM burs within their recommended lifetime.

15.
J Esthet Restor Dent ; 36(7): 1056-1067, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38581272

ABSTRACT

OBJECTIVE: To evaluate the effect of fluoride consistency and composition to protect enamel and dentin against the dental erosion. MATERIALS AND METHODS: Bovine enamel and dentin specimens were treated with artificial saliva, neutral fluoride gel (NFG), acidulated phosphate fluoride gel (AFG), neutral fluoride foam (NFF), and acidulated phosphate fluoride foam. The samples were subjected to cycling. Micro energy-dispersive X-ray fluorescence spectrometry, surface roughness (Ra), contact angle (CA), and scanning electron microscopy (SEM) were performed. Composition, CA and Ra data were analyzed by ANOVA and multiple comparison test (p < 0.05). RESULTS: The dentin protected had a significantly higher mineral content than in the control. Eroded unprotected enamel had higher Ra values than normal surfaces. Fluoride treatments increased the Ra in dentin samples. AFG increased the CA in enamel. Fluoride foams increased CA in dentin with reduced mineral loss. SEM analysis found a deposited layer on enamel treated with AFG and remnants of deposits on dentin treated with NFG and NFF. CONCLUSION: Regardless of the form of application, fluoride provided protection against erosion, however with different levels. CLINICAL SIGNIFICANCE: Applying the adequate fluoride form is relevant since the formulations have different effects on both enamel and dentin.


Subject(s)
Dental Enamel , Dentin , Fluorides , Microscopy, Electron, Scanning , Spectrometry, X-Ray Emission , Surface Properties , Tooth Erosion , Animals , Tooth Erosion/prevention & control , Cattle , Dental Enamel/drug effects , Dentin/drug effects , Fluorides/pharmacology , Acidulated Phosphate Fluoride/pharmacology , Saliva, Artificial , Fluorides, Topical/pharmacology
16.
Int J Mol Sci ; 25(6)2024 Mar 09.
Article in English | MEDLINE | ID: mdl-38542137

ABSTRACT

Breast cancer is the most common cancer in women globally, often necessitating mastectomy and subsequent breast reconstruction. Silicone mammary implants (SMIs) play a pivotal role in breast reconstruction, yet their interaction with the host immune system and microbiome remains poorly understood. This study investigates the impact of SMI surface topography on host antimicrobial responses, wound proteome dynamics, and microbial colonization. Biological samples were collected from ten human patients undergoing breast reconstruction with SMIs. Mass spectrometry profiles were analyzed for acute and chronic wound proteomes, revealing a nuanced interplay between topography and antimicrobial response proteins. 16S rRNA sequencing assessed microbiome dynamics, unveiling topography-specific variations in microbial composition. Surface topography alterations influenced wound proteome composition. Microbiome analysis revealed heightened diversity around rougher SMIs, emphasizing topography-dependent microbial invasion. In vitro experiments confirmed staphylococcal adhesion, growth, and biofilm formation on SMI surfaces, with increased texture correlating positively with bacterial colonization. This comprehensive investigation highlights the intricate interplay between SMI topography, wound proteome dynamics, and microbial transmission. The findings contribute to understanding host-microbe interactions on SMI surfaces, essential for optimizing clinical applications and minimizing complications in breast reconstruction.


Subject(s)
Anti-Infective Agents , Breast Implants , Breast Neoplasms , Humans , Female , Silicones , Breast Implants/adverse effects , Breast Neoplasms/surgery , Proteome , RNA, Ribosomal, 16S/genetics , Mastectomy , Fibrosis
17.
BMC Oral Health ; 24(1): 789, 2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39003474

ABSTRACT

BACKGROUND: Currently, the advantages of monochromatic universal composite resin restorative materials have increased their use in dentistry. Accordingly, the optical, surface and mechanical properties of these materials have become more important. This study aimed to evaluate the effect of detox solution on discoloration, surface roughness (SR), and microhardness of different monochromatic universal composite resins (Omnichroma [O], Zenchroma [Z], Vittra [V], and Charisma Diamond One [CDO]). Another aim of this study was to evaluate the monomer conversion degree (DC) of the materials. METHODS: A total of 80 specimens were prepared to evaluate the materials (n = 10). After the initial measurements, the specimens were immersed in a red detox solution for 21 days. Statistical data analysis was performed using one-way ANOVA and Tukey's multiple comparisons. RESULTS: The ∆E values of Z were highest on the 21st day. There was an increase in the SR values of the materials immersed in the detox solution. On the 21st day, top surface microhardness of O was lower than the other materials. There was no statistically significant difference at DC values among material groups. CONCLUSIONS: The use of detox solutions for a commercially recommended period of 21 days is suggested. However, this usage period can cause discoloration in restorative materials. Furthermore, especially in the initial one-week period, detox solution may have a negative impact on the microhardness of the materials. In light of all these data, we recommend the cautious use of detox solutions to prevent adverse effects on restorative materials.


Subject(s)
Color , Composite Resins , Hardness , Materials Testing , Surface Properties , Composite Resins/chemistry , Dental Materials/chemistry
18.
BMC Oral Health ; 24(1): 358, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38509532

ABSTRACT

OBJECTIVE: This study aimed to evaluate enamel surface integrity and time consumed during residual cement removal after bracket debonding using different adhesive removal burs with and without a dental loupe. MATERIAL AND METHODS: Sixty human-extracted premolars were collected, cleaned, mounted, and prepared for orthodontic bracket bonding. Teeth were randomly divided into three main groups (n = 20) based on the adhesive removal method: tungsten carbide system (TC), sof-lex discs system (SD), and diamond system (DB) groups. Then, each group was subdivided into two subgroups (naked eye and magnifying loupe subgroups). The brackets were bonded and then debonded after 24 h, and the Adhesive Remnant Index (ARI) was assessed. The adhesive remnants were removed by different systems, and the final polishing was performed by Silicone OneGloss. The enamel surface roughness was evaluated before bracketing (T0), after residual cement removal (T1), and finally after polishing (T2) using surface Mitutoyo SJ-210 profilometry and Scanning Electron Microscopy (SEM) to determine the Enamel Damage Index (EDI) score. The time consumed for adhesive removal was recorded in seconds. RESULTS: The Kruskal Wallis test showed a statistically significant difference in roughness values at T1 compared to T2 between subgroups (p < 0.001). When comparing EDI at T1 and T2, the Kruskal-Wallis H-test showed statistically significant differences in all subgroups. The pairwise comparisons revealed that EDI scores showed a statistically significant difference at T1 and T2 between DB vs. TC and SD (p = 0.015) but not between TC vs. SD (p = 1.000), indicating the highest roughness value observed in the DB group. The time for cement removal was significantly shorter in the magnifying loupe group than in the naked eye group and was shortest with the TC group, whereas the time was the longest with the DB group (p < 0.05). CONCLUSION: All three systems were clinically satisfactory for residual orthodontic adhesive removal. However, TC system produced the lowest enamel roughness, while the DB system created the greatest. The polishing step created smoother surfaces regardless of the systems used for resin removal.


Subject(s)
Dental Cements , Orthodontic Brackets , Tungsten Compounds , Humans , Bicuspid , Dental Debonding , Dental Enamel , Glass Ionomer Cements , Orthodontic Brackets/adverse effects , Surface Properties
19.
BMC Oral Health ; 24(1): 765, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38970080

ABSTRACT

OBJECTIVE: To determine the effects of conventional cigarette smoking (CS) and recent heated tobacco products (HTPs) on the surface roughness and color stability of different indirect restorative materials. MATERIALS AND METHODS: One hundred disc-shaped samples were constructed of three different restorative CAD/CAM materials: lithium disilicate glass-ceramic (IPS e.max CAD; Ivoclar Vivadent, Liechtenstein), zirconia (BruxZir® Zirconia, Glidewell, USA) and polyetheretherketone (BioHPP® bredent GmbH, Germany). Of the IPS e.max CAD and the Bruxzir samples, 20 samples were glazed, and 20 samples were polished, while the BioHPP samples were all polished according to the manufacturer's instructions. Fifty samples were subjected to conventional cigarette smoking (LM, Philip Morris International Inc., Egypt) (Groups: IPS e.max CAD_Glazed exposed to CS (LD_G_Cig), IPS e.max CAD_Polished exposed to CS (LD_P_Cig), Bruxzir_Glazed exposed to CS (Zr_G_Cig), Bruxzir _Polished exposed to CS (Zr_P_Cig) and BioHPP exposed to CS (PEEK_Cig) and fifty samples were exposed to heated tobacco product smoking (Heets, Russet selection, Philip Morris International Inc., Italy) (Groups: IPS e.max CAD_Glazed exposed to HTP (LD_G_HTP), IPS e.max CAD_Polished exposed to HTP (LD_P_HTP), Bruxzir_Glazed exposed to HTP (Zr_G_HTP), Bruxzir CAD_Polished exposed to HTP (Zr_P_HTP) and BioHPP exposed to HTP (PEEK_HTP).. Six hundred cigarettes/heets representing 30 days of medium smoking behavior (20 cigarettes/day) were used. Before and after exposure to smoke, the surface roughness of all the samples was measured using JITAI8101 surface roughness tester (Beijing Jitai Tech Detection Device Co., Ltd, China, and the color parameters were assessed using VITA Easyshade Advance 4.01 (VITA shade, VITA made, VITA). The data were analyzed using One-way ANOVA, paired sample t-test and independent sample t-test. The significance level was set at α < 0.05. The surface topography was evaluated by scanning electron microscopy (SEM) and analyzed using energy-dispersive X-ray (EDX) spectroscopy to determine changes in the surface chemical composition. RESULTS: Both types of smoking caused significant increases in the surface roughness of all the samples. There was a significant difference in color change between CS and HTP for all materials with different surface finish (P < 0.01) and zirconia had the greatest effect on color change (P < 0.001). In contrast, polyetheretherketone (PEEK) "BioHPP" had the least effect (P < 0.001). CONCLUSION: Exposure to different types of smoking induce changes in the surface topography and color of different esthetic restorative materials. Compared with HTP, conventional cigarette smoke has a greater effect on the surface roughness and color stability of esthetic restorative materials. The glazed surfaces showed less change in surface topography than did the polished surfaces. Zirconia showed better color stability when compared to polyetheretherketone (PEEK).


Subject(s)
Ceramics , Cigarette Smoking , Computer-Aided Design , Dental Materials , Dental Porcelain , Ketones , Polyethylene Glycols , Polymers , Surface Properties , Tobacco Products , Zirconium , Polyethylene Glycols/chemistry , Zirconium/chemistry , Tobacco Products/adverse effects , Ceramics/chemistry , Ketones/chemistry , Dental Porcelain/chemistry , Cigarette Smoking/adverse effects , Dental Materials/chemistry , Benzophenones , Materials Testing , Hot Temperature , Humans , Color , Dental Restoration, Permanent
20.
BMC Oral Health ; 24(1): 267, 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38395828

ABSTRACT

BACKGROUND: Studies investigating thermocycling effect on surface topography and fracture toughness of resins used in digitally manufactured denture bases are few. The study aimed to assess the impact of thermocycling on surface topography and fracture toughness of materials used for digitally manufactured denture bases. METHODS: Water sorption, solubility, hardness, surface roughness, and fracture toughness of both three-dimensional (3D)-printed and computer-aided design, computer-aided manufacturing (CAD-CAM) milled specimens (n = 50) were assessed both prior to and following 2000 thermocycles, simulating 2 years of clinical aging. Surface hardness (n = 10) was measured using a Vickers hardness testing machine, surface roughness (n = 10) was determined by a contact profilometer, and fracture toughness (n = 20) was measured using the 3-point bend test, then studying the fractured surfaces was done via a scanning electron microscope (SEM). Prior to and following thermocycling, water sorption and solubility (n = 10) were assessed. Normally distributed data was tested using two-way repeated ANOVA and two-way ANOVA, while Mann Whitney U test and the Wilcoxon signed ranks test were used to analyze data that was not normally distributed (α < 0.05). RESULTS: Following thermocycling, Vickers hardness and fracture toughness of both groups declined, with a significant reduction in values of the 3D-printed resin (P < .001). The 3D-printed denture base resins had a rougher surface following thermocycling with a significant difference (P < .001). The sorption and solubility of water of both materials were not affected by thermocycling. CONCLUSIONS: Before and after thermocycling, milled specimens had lower surface roughness and a greater degree of hardness and fracture toughness than 3D-printed specimens. Thermocycling lowered hardness and fracture toughness, and increased surface roughness in both groups, but had no effect on water sorption and solubility.


Subject(s)
Computer-Aided Design , Denture Bases , Humans , Materials Testing , Surface Properties , Water
SELECTION OF CITATIONS
SEARCH DETAIL