Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.972
Filter
Add more filters

Publication year range
1.
Int J Legal Med ; 138(4): 1357-1368, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38570340

ABSTRACT

Gunshot wound analysis is an important part of medicolegal practice, in both autopsies and examinations of living persons. Well-established and studied simulants exist that exhibit both physical and biomechanical properties of soft-tissues and bones. Current research literature on ballistic wounds focuses on the biomechanical properties of skin simulants. In our extensive experimental study, we tested numerous synthetic and natural materials, regarding their macromorphological bullet impact characteristics, and compared these data with those from real bullet injuries gathered from medicolegal practice. Over thirty varieties of potential skin simulants were shot perpendicularly, and at 45°, at a distance of 10 m and 0.3 m, using full metal jacket (FMJ) projectiles (9 × 19 mm Luger). Simulants included ballistic gelatine at various concentrations, dental silicones with several degrees of hardness, alginates, latex, chamois leather, suture trainers for medical training purposes and various material compound models. In addition to complying to the general requirements for a synthetic simulant, results obtained from dental silicones shore hardness 70 (backed with 20 % by mass gelatine), were especially highly comparable to gunshot entry wounds in skin from real cases. Based on these results, particularly focusing on the macroscopically detectable criteria, we can strongly recommend dental silicone shore hardness 70 as a skin simulant for wound ballistics examinations.


Subject(s)
Forensic Ballistics , Gelatin , Skin , Wounds, Gunshot , Wounds, Gunshot/pathology , Forensic Ballistics/methods , Humans , Skin/injuries , Skin/pathology , Latex , Silicones , Models, Biological , Hardness
2.
Clin Oral Investig ; 28(7): 402, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38940942

ABSTRACT

OBJECTIVES: Evaluate the efficacy of denture cleaners on the adhesion of Candida albicans and their effects on the surface, optical, and mechanical properties of resins for conventional, milled, and 3D-printed denture bases. MATERIALS AND METHODS: A total of 240 resin samples were made, 120 for testing Candida albicans adhesion, optical stabilities (ΔE00), roughness (Ra), hydrophilicity (°), surface free energy (Owens-Wendt) and 120 samples for testing Candida albicans adhesion, surface microhardness (Knoop), flexural strength and modulus of elasticity in a three-point test, in which they were divided into 3 groups of denture resin (n = 40) and subdivided into 5 cleaners of dentures (n = 8). Data were evaluated by two-way ANOVA and Tukey's test for multiple comparisons (α = 0.05). RESULTS: Denture cleaners with an alkaline solution and dilute acid composition were those that showed the greatest effectiveness in reducing Candida albicans (P < 0.001), however 1% NaOCl significantly affected the properties of the resins (P < 0.05). Denture 3D-printed showed that the surface microhardness was significantly lower for all cleansers (P < 0.05). CONCLUSIONS: Listerine demonstrated superior efficacy in reducing Candida albicans with minimal effect on denture properties, whereas 1% NaOCl had a significant negative impact on the properties. The mechanical properties were significantly lower in 3D-printed resin than in other resins for all denture cleansers. CLINICAL RELEVANCE: Denture base materials are being sold to adapt to the CAD/CAM system, increasing the number of users of dentures manufactured with this system. Despite this, there is little investigation into denture cleaners regarding the adhesion capacity of microorganisms and the optical, surface and mechanical properties of dentures, thus requiring further investigation.


Subject(s)
Candida albicans , Computer-Aided Design , Denture Bases , Denture Cleansers , Materials Testing , Printing, Three-Dimensional , Surface Properties , Candida albicans/drug effects , Denture Bases/microbiology , Denture Cleansers/pharmacology , Hardness , Flexural Strength , Dental Materials/chemistry
3.
Clin Oral Investig ; 28(6): 324, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38761225

ABSTRACT

OBJECTIVES: To assess the growth of a multispecies biofilm on root canal dentin under different radiotherapy regimens. MATERIALS AND METHODS: Sixty-three human root dentin cylinders were distributed into six groups. In three groups, no biofilm was formed (n = 3): NoRT) non-irradiated dentin; RT55) 55 Gy; and RT70) 70 Gy. In the other three groups (n = 18), a 21-day multispecies biofilm (Enterococcus faecalis, Streptococcus mutans, and Candida albicans) was formed in the canal: NoRT + Bio) non-irradiated + biofilm; RT55 + Bio) 55 Gy + biofilm; and RT70 + Bio) 70 Gy + biofilm. The biofilm was quantified (CFUs/mL). Biofilm microstructure was assessed under SEM. Microbial penetration into dentinal tubules was assessed under CLSM. For the biofilm biomass and dentin microhardness pre- and after biofilm growth assessments, 45 bovine dentin specimens were distributed into three groups (n = 15): NoRT) non-irradiated + biofilm; RT55 + Bio) 55 Gy + biofilm; and RT70 + Bio) 70 Gy + biofilm. RESULTS: Irradiated specimens (70 Gy) had higher quantity of microorganisms than non-irradiated (p = .010). There was gradual increase in biofilm biomass from non-irradiated to 55 Gy and 70 Gy (p < .001). Irradiated specimens had greater reduction in microhardness after biofilm growth. Irradiated dentin led to the growth of a more complex and irregular biofilm. There was microbial penetration into the dentinal tubules, regardless of the radiation regimen. CONCLUSION: Radiotherapy increased the number of microorganisms and biofilm biomass and reduced dentin microhardness. Microbial penetration into dentinal tubules was noticeable. CLINICAL RELEVANCE: Cumulative and potentially irreversible side effects of radiotherapy affect biofilm growth on root dentin. These changes could compromise the success of endodontic treatment in oncological patients undergoing head and neck radiotherapy.


Subject(s)
Biofilms , Candida albicans , Dental Pulp Cavity , Dentin , Enterococcus faecalis , Streptococcus mutans , Biofilms/radiation effects , Dentin/microbiology , Dentin/radiation effects , Humans , Dental Pulp Cavity/microbiology , Dental Pulp Cavity/radiation effects , Candida albicans/radiation effects , Animals , Enterococcus faecalis/radiation effects , Streptococcus mutans/radiation effects , Cattle , Microscopy, Electron, Scanning , Hardness , Microscopy, Confocal , Radiotherapy Dosage
4.
Clin Oral Investig ; 28(1): 119, 2024 Jan 26.
Article in English | MEDLINE | ID: mdl-38277034

ABSTRACT

OBJECTIVES: To evaluate the anti-demineralizing effect of a mouthwash comprising pomegranate peel extract (PPE 3%), sodium trimetaphosphate (TMP 0.3%), and fluoride (F 225 ppm) in an in situ study, and to assess its irritation potential in an ex vivo study. METHODS: This double-blind crossover study was conducted in four phases with 7 days each. Twelve volunteers used palatal appliances containing enamel blocks, which were subjected to cariogenic challenges. The ETF formulation (PPE + TMP + F, pH 7.0), TF formulation (TMP + F, pH 7.0), deionized water (W, pH 7.0), and essential oil commercial mouthwash (CM, 220 ppm F, pH 4.3) were dropped onto the enamel twice daily. The percentage of surface hardness loss, integrated loss of subsurface hardness, calcium, phosphorus, and fluoride in enamel and biofilms were determined. In addition, alkali-soluble extracellular polysaccharide concentrations were analyzed in the biofilms. The irritation potential was evaluated using the hen's egg chorioallantoic membrane test through the vascular effect produced during 300-s of exposure. RESULTS: ETF was the most efficacious in preventing demineralization. It also showed the highest concentrations of calcium and phosphorus in the enamel and in the biofilm, as well as the lowest amount of extracellular polysaccharides in the biofilm. In the eggs, ETF produced light reddening, whereas CM led to hyperemia and hemorrhage. CONCLUSIONS: The addition of PPE to formulations containing TMP and F increased its anti-demineralizing property, and this formulation presented a lower irritation potential than the CM. CLINICAL RELEVANCE: ETF can be a promising alternative alcohol-free mouthwash in patients at high risk of caries.


Subject(s)
Mouthwashes , Plant Extracts , Pomegranate , Tooth Demineralization , Humans , Calcium/analysis , Cross-Over Studies , Dental Enamel , Fluorides , Hardness , Mouthwashes/chemistry , Mouthwashes/pharmacology , Phosphorus , Polyphosphates , Tooth Demineralization/prevention & control , Plant Extracts/pharmacology
5.
Acta Odontol Scand ; 83: 264-272, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38709122

ABSTRACT

PURPOSE: The purpose of the present in vitro study is to investigate and compare the remineralising potential of Moringa Oleifera extract, eggshell, and sodium fluoride varnish on microhardness of artificially demineralised enamel of primary teeth with biomimetic minimally invasive approach following the world paradigm shift towards natural products in paediatric dentistry. MATERIAL AND METHODS: Sample size included 44 primary molars. The mineral content and surface microhardness of all specimens were initially assessed using energy dispersive x-ray examination (EDX) and Vickers microhardness. The specimens were artificially demineralised for 96 h at a temperature of 37°C and then reassessed directly after demineralisation. The demineralised enamel specimens were randomly divided into four groups according to the remineralisation regimen utilised. Group 1: Artificial saliva (control); Group 2: Sodium fluoride varnish; Group 3: Eggshell hydrogel; and Group 4: Moringa Oleifera hydrogel. The specimens were stored for 8 days and then subsequently evaluated using EDX and microhardness assessment by Vickers microhardness test and scanning electron microscope (SEM).  Results: Regarding the microhardness test, there was a significant difference between the Moringa Oleifera group and Eggshell group compared to fluoride varnish (p < 0.05). Regarding EDX analysis, there was a statistically significant difference (p < 0.05) between Moringa Oleifera group and Eggshell group compared to fluoride varnish as the highest values were for Moringa Oleifera and Eggshell. On the other hand, there was no statistically significant difference (p > 0.05) between Moringa Oleifera and Eggshell in both the measurements. CONCLUSION: Moringa Oleifera and Eggshell might be considered as a biomimetic natural material capable of guiding enamel tissue remineralisation in early carious lesion of primary teeth. CLINICAL RELEVANCE: This research demonstrated the capability for early enamel caries to be remineralised using novel materials with a naturally counterpart implicated in biomineralisation as proved to be more effective than traditionally used fluoride varnish in primary teeth.


Subject(s)
Egg Shell , Hydrogels , Moringa oleifera , Sodium Fluoride , Tooth, Deciduous , Sodium Fluoride/administration & dosage , Tooth, Deciduous/drug effects , Egg Shell/chemistry , Humans , Moringa oleifera/chemistry , Tooth Remineralization/methods , Animals , In Vitro Techniques , Fluorides, Topical/administration & dosage , Microscopy, Electron, Scanning , Dental Enamel/drug effects , Hardness/drug effects , Spectrometry, X-Ray Emission , Tooth Demineralization/prevention & control , Tooth Demineralization/drug therapy
6.
J Esthet Restor Dent ; 36(4): 632-642, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37622399

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the effect of aging and fiber-reinforcement on the color stability, translucency, and microhardness of single-shade resin composites versus multi-shade resin composite. MATERIALS AND METHODS: Four resin composites (Filtek Z250, Omnichroma, Vittra APS Unique, Zenchroma) were tested. Three subgroups of specimens were prepared for each of the composites: control, polyethylene fiber-reinforcement, and glass fiber-reinforcement- groups (n = 10/per group). The samples were subjected to aging for 10,000 thermal cycles. Color differences (ΔE00 ) were calculated after aging. Relative translucency parameter (RTP00 ) and microhardness values were calculated before and after aging. A two-way analysis of variance and the generalized linear model was used (p < 0.05). RESULTS: The lowest and highest ΔE00 values were found for Filtek Z250 (0.6 ± 0.2) and Omnichroma resin composites (1.6 ± 0.4), respectively. The ΔE00 value of the polyethylene fiber-reinforcement group (1.2 ± 0.6) was significantly higher than the ΔE00 value of the glass fiber-reinforcement group (1.0 ± 0.4, p < 0.001). The RTP00 value of the glass fiber-reinforcement group (1.92 ± 0.78) was significantly higher than the RTP00 value of the polyethylene fiber-reinforcement group (1.72 ± 0.77, p < 0.001). The highest microhardness values were found in glass fiber-reinforcement group (76.48 ± 17.07, p < 0.001). CONCLUSION: Single-shade resin composites were more translucent, had higher color change, and lower hardness than multi-shade resin composite. For relative translucency and microhardness, statistical significance was found in the material and fiber type interaction. The glass fiber-reinforcement provided higher translucency, lower color change and higher microhardness values than polyethylene fiber-reinforcement group after aging. Thermocycling had a significant impact on the color stability, translucency parameter, and microhardness of the tested resin composite materials. CLINICAL SIGNIFICANCE: Single-shade resin composite materials have greater color-changing potential. The glass fiber-reinforcement optimize resin material mechanical properties and color stability more than polyethylene fiber-reinforcement.


Subject(s)
Composite Resins , Polyethylene , Color , Hardness , Materials Testing
7.
J Esthet Restor Dent ; 36(3): 503-510, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37994681

ABSTRACT

OBJECTIVE: Measure and compare the mechanical properties, translucency, and fluoride-releasing capabilities of EQUIA Forte HT against Fuji IX GP and ChemFil Rock. MATERIALS AND METHODS: Ten specimens of each material were fabricated for compressive strength (CS), flexural strength (FS), and surface hardness analysis at 24 h and 7 days. The L*a*b* values were measured against a black-and-white background using a spectrophotometer to analyze the translucency parameter (TP). Fluoride release was recorded after 2 months of immersion in distilled water. The mean data was analyzed by 1- and 2-way ANOVA (α = 0.5). RESULTS: EQUIA Forte HT showed higher CS, surface hardness, and FS values (p < 0.05) compared with Fuji IX GIC, while no significant difference was found in FS values between EQUIA Forte HT and Chemfil Rock (p > 0.05). The EQUIA Forte HT exhibited significantly higher translucency in comparison to both ChemFil Rock (p < 0.001) and Fuji IX GICs (p < 0.05). An increase (p > 0.05) of fluoride release was observed for EQUIA Forte HT. CONCLUSION: The EQUIA Forte HT Glass-ionomer cements (GIC) offers enhanced translucency, improved strength, and enhanced fluoride-releasing properties compared to the traditionally used Fuji IX GIC and ChemFil Rock GICs. This material might have a wide range of clinical applications due to its improved strength and optical properties. CLINICAL SIGNIFICANCE: Glass-ionomer dental restorative materials possess unique advantageous characteristics. However, its poor mechanical and optical properties have typically limited its clinical applications. Efforts to improve these properties have resulted in enhanced GICs. EQUIA Forte HT GIC offers enhanced mechanical and optical properties with potential applications in posterior and anterior restorative procedures.


Subject(s)
Aluminum Silicates , Dental Materials , Fluorides , Glass Ionomer Cements , Compressive Strength , Hardness , Materials Testing
8.
J Esthet Restor Dent ; 36(6): 920-929, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38404208

ABSTRACT

OBJECTIVES: To evaluate surface microhardness and gingival marginal adaptation of three different bulk-fill flowable resin composites (FB-RBCs) in Class V cavities with enamel or dentin margins before and after thermocycling (TMC). MATERIALS AND METHODS: Three available FB-RBCs were used; Palfique Bulk Flow (PaBF) (Tokuyama Dental), SDR Flow+ Bulk Fill Flowable (Dentsply Sirona), and I-Flow Bulk Fill (I-Dental). Thirty discs were prepared from each type of FB-RBCs. The discs were subjected to Vickers microhardness tester machine. Class V cavities were prepared on 180 molars. Gingival margins of half the specimens were prepared above CEJ and the other half below CEJ. Cavities were restored with FB-RBCs for gingival marginal adaptation test. Two-way ANOVA was used in microhardness, while three-way ANOVA was used for marginal adaptation. RESULTS: The used materials showed statistically significant differences in microhardness and marginal adaptation. CONCLUSIONS: Regarding microhardness, PaBF showed the highest value before TMC and SDR was the highest after TMC. Regarding marginal adaptation, SDR revealed the best marginal adaptation than PaBF and I-flow, either subjected to TMC or not. CLINICAL SIGNIFICANCE: The longevity of cervical restorations depend on both the location of the cavity margin and the material used. The microfractures in resin composite surface due to low surface microhardness as well as marginal gaps seen in laboratory studies could be considered as an indicative parameter for clinical problem associated with marginal differences.


Subject(s)
Composite Resins , Composite Resins/chemistry , Humans , Hardness , Surface Properties , Dental Marginal Adaptation , Gingiva , Materials Testing , Dental Restoration, Permanent/methods
9.
Int J Mol Sci ; 25(8)2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38673982

ABSTRACT

The research presented in this article focuses on the use of inorganic-organic material, based on titanium dioxide and lignin, as a filler for polylactide (PLA) biocomposites. To date, no research has been conducted to understand the impact of hybrid fillers consisting of TiO2 and lignin on the supermolecular structure and crystallization abilities of polylactide. Polymer composites containing 1, 3 or 5 wt.% of hybrid filler or TiO2 were assessed in terms of their structure, morphology, and thermal properties. Mechanical properties, including tensile testing, bending, impact strength, and hardness, were discussed. The hybrid filler is characterized by a very good electrokinetic stability at pH greater than 3-4. The addition of all fillers led to a small decrease in the glass transition temperature but, most importantly, the addition of 1% of the hybrid filler to the PLA matrix increased the degree of crystallinity of the material by up to 20%. Microscopic studies revealed differences in the crystallization behavior and nucleation ability of fillers. The use of hybrid filler resulted in higher nucleation density and shorter induction time than in unfilled PLA or PLA with only TiO2. The introduction of small amounts of hybrid filler also affected the mechanical properties of the composites, causing an increase in bending strength and hardness. This information may be useful from a technological process standpoint and may also help to increase the range of applicability of biobased materials.


Subject(s)
Lignin , Polyesters , Titanium , Titanium/chemistry , Polyesters/chemistry , Lignin/chemistry , Crystallization , Tensile Strength , Materials Testing , Hardness
10.
J Esthet Restor Dent ; 36(6): 901-910, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38348937

ABSTRACT

To assess the physical properties and topographical aspect of dental enamel's surface microhardness (KHN), surface roughness (Ra), and color parameters CIELAB (∆Eab*), CIEDE 2000 (∆E00), and whiteness index for dentistry (∆WID) after toothbrushing with experimental toothpaste formulations with the following mineral clay types: kaolin, Sparclay SGY, and Tersil CGY used as abrasive component. Scanning electron microscopy (SEM) was performed for topographical analyses purposes. A total of 96 bovine incisors were used in the experiment. They were divided into eight experimental groups (n = 12), namely: NC-negative control (no treatment), CT12-Colgate Total 12®, CMP-Colgate® Máxima Proteção Anticáries, K-kaolin experimental toothpaste, SGY-Sparclay SGY experimental toothpaste; CGY-Tersil CGY experimental toothpaste, SD-SiO2 experimental toothpaste, and CC-CaCO3 experimental toothpaste. All samples were subjected to mechanical brushing protocol with 5000 cycles and kept in artificial saliva with daily exchanges. KHN was analyzed through the mixed linear model for repeated measures over time. Ra was analyzed through nonparametric Kruskal Wallis and Dunn tests to compare the groups. Paired Wilcoxon test was run to compare experimental times. ∆WID, ∆Eab*, and ∆E00 were analyzed through Kruskal Wallis and Dunn tests. All analyses were performed in R* software, at 5% significance level. EXP_SGY recorded higher KHN than EXP_SiO2 and EXP_CaCO3, whereas EXP_K showed increased Ra in comparison to CMP (p = 0.0229). ∆Eab and ∆E00 were significantly higher in the CT12, EXP_SiO2, and EXP_CaCO3 groups than in the NC and EXP_K (p < 0.0001). There were no significant changes in ∆WID (p = 0.0852). According to SEM results, toothbrushing with experimental toothpastes added with mineral clay types did not have significant impact on enamel's polishing and smoothness. CLINICAL RELEVANCE: Mineral clays have a broad application in the cosmetic industry, and recently, they have been used in the formulation of vegan toothpaste.


Subject(s)
Aluminum Silicates , Clay , Dental Enamel , Hardness , Toothbrushing , Toothpastes , Toothpastes/chemistry , Animals , Cattle , Clay/chemistry , Aluminum Silicates/chemistry , Surface Properties , Microscopy, Electron, Scanning
11.
J Esthet Restor Dent ; 36(4): 663-672, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37846764

ABSTRACT

OBJECTIVE: The present study aimed to evaluate the effect of remineralizing agents on demineralized enamel intended for use as fluoride substitutes or supplements for oral hygiene applications. METHODOLOGY: Enamel samples were obtained from 30 bovine teeth. The enamel blocks were stored in 20 mL of demineralization solution for 72 h. They were then brushed with the following toothpaste for the remineralization protocol: NaF, NaF/SnF2 combination, NovaMin, or nano-hydroxyapatite. SEM/EDX examinations and microhardness measurements of the samples were performed to investigate the remineralization efficacy of the studied toothpaste. One-way analysis of variance (ANOVA) with post hoc Tukey's HSD test was used to analyze the change in microhardness values in different remineralization protocols (p < 0.05). RESULTS: Differences in the mean remineralization (%RP) and hardness recovery (%HR) were determined between the groups (p < 0.05). Groups 1 and 4 showed significant differences in %RP (p < 0.05). In the SEM/EDX examinations, the samples treated with n-HAp showed an accumulation of crystal deposits on the enamel surface, although at a lower density than those treated with NaF and NaF/SnF2 combination. CONCLUSION: The remineralization strategy in toothpaste plays an important role in enamel remineralization. NovaMin-containing toothpaste showed positive effects on the enamel surface with better Ca/P ratio. Toothpastes containing n-HAp triggered less change in the increase of microhardness values compared to other toothpastes. The use of SnF2 in toothpaste in combination with NaF significantly increased the binding of fluoride to demineralized enamel compared to toothpaste containing NaF alone.


Subject(s)
Fluorides , Tooth Demineralization , Animals , Cattle , Toothpastes/pharmacology , Toothpastes/analysis , Toothpastes/chemistry , Dental Enamel/chemistry , Hardness , Tooth Remineralization/methods , Cariostatic Agents/analysis , Cariostatic Agents/chemistry , Cariostatic Agents/pharmacology
12.
Eur J Orthod ; 46(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38073597

ABSTRACT

OBJECTIVES: Three-dimensional (3D)-printed aligners present a promising orthodontic treatment modality, whose clinical success largely depends on the material's mechanical properties. The aim of this study was to evaluate the mechanical properties of resin-made 3D-printed aligners and assess the effect of two different post-curing conditions. MATERIALS AND METHODS: Forty dumbbell-shaped specimens and 40 resin aligners were 3D-printed and divided into four equal groups according to post-curing conditions: presence or absence of oxygen during post-curing and water heat treatment at 85°C for 15 s or none. Samples from the central incisor of the aligner (n = 5/group) were studied by Attenuated Total Reflection Fourier-transform infrared spectroscopy (ATR-FTIR). The dumbbell-shaped specimens were loaded up to fracture under tensile mode and yield strength, ultimate tensile strength, elastic and plastic strain were calculated. The first mandibular molar area from 3D-printed aligners (n = 10/group) was cut and embedded in acrylic resin and then underwent metallographic grinding and polishing followed by instrumented indentation testing to determine the following mechanical properties: Martens hardness, indentation modulus, elastic index, and indentation relaxation. After descriptive statistics, differences according to each post-curing protocol, as well as their combination, were analyzed with linear regression modeling at a 5% significance level. RESULTS: All groups showed identical ATR-FTIR spectra, while no statistically significant effects were seen for either post-curing protocol (N2 presence and heat treatment) or their combination (P > .05 in all instances). CONCLUSIONS: The mechanical properties of 3D-printed resin aligners were not considerably affected either by post-curing in N2 atmosphere or heat treatment.


Subject(s)
Hot Temperature , Tooth , Humans , Hardness , Printing, Three-Dimensional , Materials Testing , Surface Properties
13.
Eur J Orthod ; 46(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37936263

ABSTRACT

OBJECTIVE: The objective of this study was to examine the impact of intraoral aging on the mechanical properties of directly printed aligners (DPA) compared to thermoformed aligners (TA). MATERIALS AND METHODS: This prospective in vivo experiment included three types of aligners: DPAs (group DP) fabricated from Tera Harz TC-85 DAC resin (Graphy, Korea), TA (group INV) made from a polyurethane-based polymer (Align Technology, Inc., CA, USA), and TA (group DUR) made from polyethylene glycol terephthalate based polymer (Scheu-Dental, Germany). Each group was categorized into retrieved (Clin) and unused aligners (Ctr). Thirty patients (10 per group) wore the aligners for 7 days, thereby generating the retrieved samples. Thirty unused aligners were employed as control samples. The following mechanical properties were determined: Martens Hardness (HM), indentation modulus (EIT), elastic index (ηIT), and indentation relaxation (RIT). Intergroup comparisons were conducted using ANOVA/Kruskal-Wallis test. Comparisons between retrieved and control samples were done using Wilcoxon-Mann-Whitney-U/Student's t-test/Welch's test. RESULTS: Statistically significant differences between the groups were found for both control and used samples (P < .001). Pairwise comparisons also revealed significant differences between the samples. The mechanical properties did not differ significantly between unused and retrieved INV- and DUR-aligners, whereas for DP-aligners significant differences for ηIT and RIT were found following intraoral service (P-values .012 and .002, respectively). CONCLUSIONS: Group DUR showed generally more favorable mechanical properties compared to DP and INV. The much higher RIT and EIT in DP aligners suggest their higher rigidity and force decay, which could compromise their clinical efficacy.


Subject(s)
Mechanical Phenomena , Polyurethanes , Humans , Prospective Studies , Hardness , Polyethylene Glycols , Materials Testing
14.
BMC Oral Health ; 24(1): 487, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38658909

ABSTRACT

BACKGROUND: Zinc-oxide eugenol (ZOE) cements are among the most used temporary materials in dentistry. Although ZOE has advantages over other temporary fillers, its mechanical strength is weaker, so researchers are working to improve it. E-glass fibers have emerged as promising reinforcing fibers in recent years due to their strong mechanical behavior, adequate bonding, and acceptable aesthetics. OBJECTIVES: To evaluate and compare the compressive strength, surface microhardness, and solubility of the ZOE and those reinforced with 10 wt.% E-glass fibers. METHODS: A total of 60 ZEO specimens were prepared; 30 specimens were reinforced with 10 wt.% E-glass fibers, considered modified ZOE. The characterization of the E-glass fibers was performed by XRF, SEM, and PSD. The compressive strength, surface microhardness, and solubility were evaluated. Independent sample t-tests were used to statistically assess the data and compare mean values (P ≤ 0.05). RESULTS: The results revealed that the modified ZOE showed a significantly higher mean value of compressive strength and surface microhardness while having a significantly lower mean value of solubility compared to unmodified ZOE (P ≤ 0.05). CONCLUSION: The modified ZOE with 10 wt.% E-glass fibers had the opportunity to be used as permanent filling materials.


Subject(s)
Compressive Strength , Glass , Hardness , Materials Testing , Solubility , Zinc Oxide-Eugenol Cement , Zinc Oxide-Eugenol Cement/chemistry , Glass/chemistry , Surface Properties , Microscopy, Electron, Scanning
15.
BMC Oral Health ; 24(1): 620, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807109

ABSTRACT

BACKGROUND: The mechanical properties of fully crystallized lithium aluminosilicate ceramics may be influenced by intraoral temperature variations and postmilling surface treatment. The purpose of this study is to explore the interplay among glazing, thermocycling, and the mechanical characteristics (namely, fracture toughness and hardness) of fully crystallized lithium aluminosilicate ceramics. METHODS: Bending bars (n = 40) cut from LisiCAD blocks (GC, Japan) were randomly assigned to glazed or unglazed groups (n = 20) and subjected to the single edge v-notch beam method to create notches. A glazing firing cycle was applied to the glazed group, while the unglazed group was not subjected to glazing. Half of the specimens (n = 10) from both groups underwent thermocycling before fracture toughness testing. The fracture toughness (KIC) was evaluated at 23 ± 1 °C using a universal testing machine configured for three-point bending, and the crack length was measured via light microscopy. Seven specimens per group were selected for the hardness test. Hardness was assessed using a Vickers microhardness tester with a 1 kg load for 20 s, and each specimen underwent five indentations following ISO 14705:2016. The Shapiro-Wilk and Kolmogorov-Smirnov tests were used to evaluate the normality of the data and a two-way ANOVA was utilized for statistical analysis. The significance level was set at (α = 0.05). RESULTS: Regardless of the thermocycling conditions, the glazed specimens exhibited significantly greater fracture toughness than did their unglazed counterparts (P < 0.001). Thermocycling had no significant impact on the fracture toughness of either the glazed or unglazed specimens. Furthermore, statistical analysis revealed no significant effects on hardness with thermocycling in either group, and glazing alone did not substantially affect hardness. CONCLUSIONS: The impact of glazing on the fracture toughness of LiSiCAD restorations is noteworthy, but it has no significant influence on their hardness. Furthermore, within the parameters of this study, thermocycling was found to exert negligible effects on both fracture toughness and hardness.


Subject(s)
Aluminum Silicates , Ceramics , Computer-Aided Design , Hardness , Materials Testing , Ceramics/chemistry , Aluminum Silicates/chemistry , Dental Stress Analysis , Surface Properties , Crystallization
16.
BMC Oral Health ; 24(1): 162, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38302972

ABSTRACT

BACKGROUND: Computer-aided design/computer-aided manufacturing (CAD/CAM) dental composites were introduced with superior mechanical properties than conventional dental composites. However, little is known on effects of dietary solvents on microhardness or inorganic elemental composition of CAD/CAM composites. OBJECTIVES: The objectives of this study were to evaluate the degradation effects of each dietary solvent on the microhardness of the different CAD/CAM dental composites and to observe the degradation effects of dietary solvent on the inorganic elements of the dental composites investigated. METHODS: Fifty specimens with dimensions 12 mm x 14 mm x 1.5 mm were prepared for direct composite (Filtek Z350 XT [FZ]), indirect composite (Shofu Ceramage [CM]), and three CAD/CAM composites (Lava Ultimate [LU], Cerasmart [CS], and Vita Enamic [VE]). The specimens were randomly divided into 5 groups (n = 10) and conditioned for 1-week at 37°C in the following: air (control), distilled water, 0.02 N citric acid, 0.02 N lactic acid and 50% ethanol-water solution. Subsequently, the specimens were subjected to microhardness test (KHN) using Knoop hardness indenter. Air (control) and representative postconditioning specimens with the lowest mean KHN value for each material were analyzed using energy dispersive X-ray spectroscopy (EDX). Statistical analysis was done using one-way ANOVA and post hoc Bonferroni test at a significance level of p = 0.05. RESULTS: Mean KHN values ranged from 39.7 ± 2.7 kg/mm2 for FZ conditioned in 50% ethanol-water solution to 79.2 ± 3.4 kg/mm2 for VE conditioned in air (control). With exception to LU, significant differences were observed between materials and dietary solvents for other dental composites investigated. EDX showed stable peaks of the inorganic elements between air (control) and representative postconditioning specimens. CONCLUSIONS: The microhardness of dental composites was significantly affected by dietary solvents, except for one CAD/CAM composite [LU]. However, no changes were observed in the inorganic elemental composition of dental composites between air (control) and 1-week postconditioning.


Subject(s)
Ceramics , Composite Resins , Humans , Solvents , Composite Resins/chemistry , Hardness , Computer-Aided Design , Ethanol , Water , Materials Testing , Surface Properties , Dental Materials
17.
BMC Oral Health ; 24(1): 739, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38937723

ABSTRACT

BACKGROUND: In dentistry, glass-ionomer cements (GICs) are extensively used for a range of applications. The unique properties of GIC include fluoride ion release and recharge, chemical bonding to the tooth's hard tissues, biocompatibility, a thermal expansion coefficient like that of enamel and dentin, and acceptable aesthetics. Their high solubility and poor mechanical qualities are among their limitations. E-glass fibers are generally utilized to reinforce the polymer matrix and are identified by their higher silica content. OBJECTIVES: The purpose of the study was to assess the impact of adding (10 wt% and 20 wt%) silane-treated E-glass fibers to traditional GIC on its mechanical properties (compressive strength, flexural strength, and surface hardness) and solubility. METHODS: The characterization of the E-glass fiber fillers was achieved by XRF, SEM, and PSD. The specimens were prepared by adding the E-glass fiber fillers to the traditional GIC at 10% and 20% by weight, forming two innovative groups, and compared with the unmodified GIC (control group). The physical properties (film thickness and initial setting time) were examined to confirm operability after mixing. The evaluation of the reinforced GIC was performed by assessing the compressive strength, flexural strength, hardness, and solubility (n = 10 specimens per test). A one-way ANOVA and Tukey tests were performed for statistical analysis (p ≤ 0.05). RESULTS: The traditional GIC showed the least compressive strength, flexural strength, hardness, and highest solubility. While the GIC reinforced with 20 wt% E-glass fibers showed the highest compressive strength, flexural strength, hardness, and least solubility. Meanwhile, GIC reinforced with 10 wt% showed intermediate results (P ≤ 0.05). CONCLUSION: Using 20 wt% E-glass fiber as a filler with the traditional GIC provides a strengthening effect and reduced solubility.


Subject(s)
Compressive Strength , Flexural Strength , Glass Ionomer Cements , Glass , Hardness , Materials Testing , Solubility , Glass Ionomer Cements/chemistry , Glass/chemistry , Surface Properties , Silanes/chemistry , Microscopy, Electron, Scanning , Dental Stress Analysis , Pliability , Humans
18.
BMC Oral Health ; 24(1): 546, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730400

ABSTRACT

BACKGROUND: Recently, a new generation of high-strength flowable dental composites has been introduced by manufacturers. The manufacturers claim that these materials have enhanced mechanical and physical properties and are suitable for use in a wide range of direct anterior and posterior restorations, even in high-stress bearing areas. AIM: The objective of this study was to assess certain physical and mechanical properties of these recently introduced high-strength flowable composites in comparison to conventional multipurpose dental composites. METHODS: Four types of high-strength flowable composites (Genial Universal FLO, Gaenial Universal Injectable, Beautifil Injectable, and Beautifil Flow Plus) were tested in experimental groups, while a nanohybrid conventional composite (Filtek Z350 XT) was used as the control. For flexure properties, ten rectangular samples (2 × 2 × 25 mm) were prepared from each composite material and subjected to 5000 cycles of thermocycling. Samples were then subjected to flexural strength testing using the universal testing machine. Another twenty disc-shaped specimens of dimensions (5 mm diameter × 2 mm thickness) were fabricated from each composite material for surface roughness (Ra) (n = 10) and hardness (VHN) test (n = 10). All samples underwent 5000 cycles of thermocycling before testing. Additionally, microleakage testing was conducted on 60 standardized class V cavities prepared on molar teeth and divided randomly into five groups (n = 12). Cavities were then filled with composite according to the manufacturer's instructions and subjected to thermocycling for 1000 cycles before testing using methylene blue solution and a stereomicroscope. RESULTS: All tested materials were comparable to the control group in terms of flexural strength and surface roughness (p > 0.05), with Gaenial Universal FLO exhibiting significantly higher flexural strength compared to the other flowable composite materials tested. However, all tested materials demonstrated significantly lower elastic modulus and surface hardness than the control group (p < 0.05). The control group exhibited higher microleakage scores, while the lowest scores were observed in the Gaenial Universal FLO material (p < 0.05) CONCLUSION: The physical and mechanical behaviors of the different high-strength flowable composites investigated in this study varied. Some of these materials may serve as suitable alternatives to conventional composites in specific applications, emphasizing the importance of dentists being familiar with material properties before making material selections.


Subject(s)
Composite Resins , Dental Leakage , Flexural Strength , Hardness , Materials Testing , Surface Properties , In Vitro Techniques , Humans , Dental Stress Analysis , Dental Materials/chemistry , Stress, Mechanical , Polyethylene Glycols , Polymethacrylic Acids/chemistry , Bisphenol A-Glycidyl Methacrylate
19.
BMC Oral Health ; 24(1): 775, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38987748

ABSTRACT

Acrylic resins are widely used as the main components in removable orthodontic appliances. However, poor oral hygiene and maintenance of orthodontic appliances provide a suitable environment for the growth of pathogenic microorganisms. In this study, strontium-modified phosphate-based glass (Sr-PBG) was added to orthodontic acrylic resin at 0% (control), 3.75%, 7.5%, and 15% by weight to evaluate the surface and physicochemical properties of the novel material and its in vitro antifungal effect against Candida albicans (C. albicans). Surface microhardness and contact angle did not vary between the control and 3.75% Sr-PBG groups (p > 0.05), and the flexural strength was lower in the experimental groups than in the control group (p < 0.05), but no difference was found with Sr-PBG content (p > 0.05). All experimental groups showed an antifungal effect at 24 and 48 h compared to that in the control group (p < 0.05). This study demonstrated that 3.75% Sr-PBG exhibits antifungal effects against C. albicans along with suitable physicochemical properties, which may help to minimize the risk of adverse effects associated with harmful microbial living on removable orthodontic appliances and promote the use of various materials.


Subject(s)
Acrylic Resins , Antifungal Agents , Candida albicans , Glass , Materials Testing , Phosphates , Strontium , Surface Properties , Candida albicans/drug effects , Acrylic Resins/chemistry , Strontium/pharmacology , Strontium/chemistry , Antifungal Agents/pharmacology , Glass/chemistry , Phosphates/pharmacology , Polymerization , Hardness , Flexural Strength , Humans , In Vitro Techniques
20.
BMC Oral Health ; 24(1): 581, 2024 May 19.
Article in English | MEDLINE | ID: mdl-38764034

ABSTRACT

BACKGROUND: This study was conducted to compare chemical, elemental and surface properties of sound and carious dentin after application of two restorative materials resin-modified glassionomer claimed to be bioactive and glass hybrid restorative material after enzymatic chemomechanical caries removal (CMCR) agent. METHODS: Forty carious and twenty non-carious human permanent molars were used. Molars were randomly distributed into three main groups: Group 1 (negative control) - sound molars, Group 2 (positive control) - molars were left without caries removal and Group 3 (Test Group) caries excavated with enzymatic based CMCR agent. After caries excavation and restoration application, all specimens were prepared Vickers microhardness test (VHN), for elemental analysis using Energy Dispersive Xray (EDX) mapping and finally chemical analysis using Micro-Raman microscopy. RESULTS: Vickers microhardness values of dentin with the claimed bioactive GIC specimens was statistically higher than with glass hybrid GIC specimens. EDX analysis at the junction estimated: Calcium and Phosphorus of the glass hybrid GIC showed insignificantly higher mean valued than that of the bioactive GIC. Silica and Aluminum mean values at the junction were significantly higher with bioactive GIC specimens than glass hybrid GIC specimen. Micro-raman spectroscopy revealed that bioactive GIC specimens showed higher frequencies of v 1 PO 4, which indicated high level of remineralization. CONCLUSIONS: It was concluded that ion-releasing bioactive resin-based restorative material had increased the microhardness and remineralization rate of carries affected and sound dentin. In addition, enzymatic caries excavation with papain-based CMCR agent has no adverse effect on dentin substrate.


Subject(s)
Dental Caries , Dental Cavity Preparation , Dentin , Glass Ionomer Cements , Hardness , Humans , Dental Caries/therapy , Glass Ionomer Cements/chemistry , Dental Cavity Preparation/methods , Phosphorus/analysis , Papain/therapeutic use , Surface Properties , Dental Restoration, Permanent/methods , Spectrometry, X-Ray Emission , Spectrum Analysis, Raman , Calcium/analysis , Molar , Tooth Remineralization/methods , Aluminum , Silicon Dioxide , Materials Testing
SELECTION OF CITATIONS
SEARCH DETAIL