Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Prosthet Dent ; 127(6): 925.e1-925.e8, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35469648

RESUMO

STATEMENT OF PROBLEM: The influence of different glaze firing protocols and cooling on the behavior of computer-aided design and computer-aided manufacturing (CAD-CAM) ceramics is unclear. PURPOSE: The purpose of this in vitro study was to investigate the influence of different glaze firing protocols on the abrasion resistance, surface roughness, microhardness, and brittleness index of CAD-CAM ceramics. MATERIAL AND METHODS: Rectangular specimens of IPS e.max CAD (MAX), IPS Empress CAD (PRE), and CEREC Blocs (CER) were obtained and divided into 5 groups according to the glaze firing protocol (n=8): control (CO), 1 conventional glaze firing (GF), 2 conventional glaze firings (GF2), 1 extended glaze firing (EG), and 2 extended glaze firings (EG2). The coefficient of friction (µ) was determined with the pin-on-disk test, and specimens were analyzed with an optical interferometer to calculate volume loss and roughness. Vickers microhardness and the brittleness index were obtained with a microdurometer. Microhardness data were evaluated by 2-way ANOVA and the Sidak tests (α=.05). Data from other tests were assessed with nonparametric ANOVA and Bonferroni tests (α=.05). RESULTS: Groups GF2, EG, and EG2 of MAX and PRE and all groups of CER presented higher levels of coefficient of friction. Groups EG and EG2 of MAX and CER showed high volume loss and surface roughness. Groups EG and EG2 of MAX and PRE showed lower hardness, as did all groups of CER. MAX-CO and groups GF and EG of PRE showed a lower brittleness index (P<.05), while CER groups showed no significant differences (P>.05). CONCLUSIONS: Ceramic specimens with conventional glaze firing presented less surface wear than those with extended glaze firing. The number of firings did not have a statistically significant influence.


Assuntos
Cerâmica , Porcelana Dentária , Desenho Assistido por Computador , Teste de Materiais , Propriedades de Superfície
2.
J Esthet Restor Dent ; 30(4): 352-359, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-30079637

RESUMO

OBJECTIVE: The aim of this double-blind, randomized, controlled clinical study was to assess the efficacy of low-level laser therapy (LLLT) combined with 5000 ppm fluoride dentifrice on postbleaching sensitivity in teeth exposed to 35% hydrogen peroxide for four weeks. MATERIALS AND METHODS: Twenty-five volunteers were evaluated using the split-mouth model in which the right and left maxillary/mandibular quadrants were randomized and allocated to one of two groups: GPLACEBO, in which the laser tip was positioned without the emission of light (placebo effect) + 5000 ppm sodium fluoride, or GLASER, which comprised LLLT + 5000 ppm sodium fluoride. For both groups, LLLT and placebo were used before bleaching, whereas fluoride was applied after bleaching. LLLT was applied at two points: on the central cervical and medial regions of the incisors, canines, and premolars in the corresponding hemi-arch. At each point, 60 J/cm2 was applied for 16 seconds with an irradiance of 3.75 W/cm2 using the therapeutic infrared device. To assess tooth sensitivity, a modified visual analogue scale was used after an evaporative stimulus, and a daily pain questionnaire was also applied. RESULTS: The Wilcoxon and Friedman tests demonstrated a significant difference in the incidence of sensitivity pain between GPLACEBO and GLASER (P ≤ .05), with different evaluation times. CONCLUSION: Teeth treated with laser therapy in combination with the topical use of sodium fluoride at each bleaching session demonstrated less sensitivity compared with the application of sodium fluoride only. CLINICAL SIGNIFICANCE: The use of a low-level laser therapy in combination with topical use of sodium fluoride improves symptoms of dentin sensitivity at each bleaching session.


Assuntos
Dentifrícios , Sensibilidade da Dentina , Terapia com Luz de Baixa Intensidade , Clareamento Dental , Método Duplo-Cego , Fluoretos , Humanos , Clareamento Dental/efeitos adversos , Resultado do Tratamento
3.
Histol Histopathol ; : 18726, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38477344

RESUMO

The use of bleaching agents to remove stains is one of the main dental procedures to improve the aesthetics of teeth. This review presents the main agents used for tooth whitening, existing clinical protocols, and the structural changes that may occur through their use. The main bleaching agents consist of hydrogen peroxide and carbamide peroxide, which are used in bleaching techniques for vital teeth. These techniques can be performed in the office by a professional or by the individual in a home en-vironment under professional guidance. Bleaching agents come in a variety of concentrations and there are over-the-counter products available on the market with lower concentrations of hydrogen peroxide. Due to the chemical characteristics of the agents, changes in the organic and inorganic content of the tooth structure can be observed. These changes are related to morphological changes characterized by in-creased permeability and surface roughness, such changes compromise the mechanical resistance of the tooth. Furthermore, bleaching agents can promote molecular changes after reaching the dental pulp, resulting in oxidative stress of pulp cells and the release of pro-inflammatory mediators. Despite the bleaching effectiveness, tooth sensitivity is considered the main side effect of use. Therefore, among the heterogeneity of protocols, those that used the bleaching agent for a prolonged time and in lower con-centrations presented more harmful effects on the tooth structure.

4.
Dent Mater J ; 43(1): 126-135, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38072410

RESUMO

The objective of the study was to evaluate the effects of dentin deproteinization protocols for post space using different formulations containing sodium hypochlorite before fiber post cementation with self-adhesive resinous cement. The groups were divided according to the irrigation protocol (DWC, SHS, SHT and SHG). The residue cleanliness, bond strength, adhesive failure pattern, and tag formation at the adhesive interface between the self-adhesive cement and the dentin were evaluated. For this, analysis in scanning electron microscope, push-out test and confocal laser scanning microscopy were performed. The SHT protocol showed the highest residue cleanliness on the dentin surface of the post space (p<0.05). In addition, SHT protocol showed highest bond strength and tag formation in the cervical and middle thirds (p<0.05). Dentin deproteinization with sodium hypochlorite with surfactant provided the best dentin cleaning of residues, bond strength and tag formation after cementation of the fiber post with self-adhesive cement.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentação/métodos , Tensoativos/farmacologia , Hipoclorito de Sódio/farmacologia , Hipoclorito de Sódio/química , Cimentos de Resina/química , Dentina , Teste de Materiais
5.
Dent Mater J ; 43(1): 112-118, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38072411

RESUMO

This study evaluated the influence of different translucent resins (Z350 and Opallis) for customizing fiber posts and light-curing the cementation system using different LED equipment (V, Valo or R, Radii-Cal) on the bond strength and adhesive failure pattern at 24 h and 6 months. Eighty roots were prepared and divided into 4 groups (n=20): ZV (Z350 resin and LED Valo), ZR (Z350 resin and LED Radii-Cal), OV (Opallis resin and LED Valo), OR (Opallis resin and LED Radii-Cal). After post space preparation, the fiber post was customized and cemented with self-adhesive cement and light-curing using V or R LED equipment. Bond strength values were submitted to 2-way ANOVA test. ZV and ZR showed higher bond strength values than the other groups at 6 months of evaluation (p<0.05). The Z350 resin has a favorable influence on the bond strength of self-adhesive cement to root dentin, regardless of the LED polymerization equipment used.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Resinas Compostas/química , Cimentação , Cimentos de Resina/química , Dentina , Teste de Materiais , Vidro/química
6.
Braz Dent J ; 34(3): 94-100, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37466531

RESUMO

This in vitro study evaluated the effect of an experimental varnish containing 20% nano-hydroxyapatite (nHAP) associated with 5% stannous chloride (SnCl2) against erosive-abrasive wear on bovine dentin. Samples of bovine cervical dentin were pre-eroded (0.3% citric acid, pH 2.6 for 10 minutes) and randomized into 4 groups (n=10): Control group - experimental varnish without active ingredient (CG); experimental varnish containing 20% nHAP (nHG); experimental varnish containing 5% SnCl2 (24.800 ppm Sn2+) (SnG); experimental varnish containing 20% nHAP associated with 5% SnCl2 (18.300 ppm Sn2+) (nHSnG). After applying the materials, the erosive-abrasive challenges were performed for five days. Erosive dentin loss and analysis of the pattern of dentinal obliteration were performed by 3D confocal laser microscopy. A one-way ANOVA/Bonferroni test was performed to analyze the data (α=0.05). The SnG and nHSnG experimental groups presented more effectiveness in preventing erosive wear when compared to the other groups (p<0.05). There was no statistically significant difference between the SnG and nHSnG groups (p = 0.731) in tooth structure dentin loss. Regarding the amount of open dentinal tubules, the highest amount of obstructed dentinal tubules was demonstrated in SnG and nHSnG (p < 0.05) when compared to the others. Between SnG and nHSnG there was no significant difference (p = 0.952) in the amount of closed dentinal tubules in the dentin. Experimental varnishes containing 5% SnCl2 associated or not with 20% nHAP showed to be a promising strategy in preventing erosive-abrasive wear of dentin. In addition, nHSnG was able to obliterate dentinal tubules.


Assuntos
Cariostáticos , Erosão Dentária , Animais , Bovinos , Ácido Cítrico , Dentina , Durapatita , Erosão Dentária/prevenção & controle , Cariostáticos/farmacologia
7.
J Dent ; 130: 104407, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36621551

RESUMO

OBJECTIVE: To evaluate the association of HEMA and 10-MDP in the clinical performance of self-etching adhesives in the restoration of NCCLs during 2-years. MATERIALS AND METHODS: 60 restorations were performed in 17 volunteers and randomized into three groups: G1 (n = 20) - Prime and Bond Universal (10-MDP); G2 (n = 20) - Optibond All-in-One (HEMA); and G3 (n = 20) - Clearfil SE (10-MDP and HEMA). No cavity preparation was performed. After 2 years, the restorations were evaluated using the modified USPHS criteria for retention, marginal adaptation/ staining, postoperative sensitivity and secondary caries. The results were analyzed using Fisher's exact test and Kruskal-Wallis test. RESULTS: All groups showed 100% retention rate, except G1, who lost two restorations (p > 0.05). Regarding marginal adaptation, G1 showed greater deficiency, as only eight restorations (40%) remained intact (p < 0.05). Regarding marginal staining, G1 and G2 showed higher rate, as only 12 restorations (65%) in each one were free of staining (p < 0.05). All groups showed similar results for postoperative sensitivity and secondary caries (p > 0.05). CONCLUSION: The association of HEMA and 10-MDP monomers in the self-etching adhesives did not influence the clinical performance of the NCCL restorations with respect to retention, postoperative sensitivity, and incidence of secondary caries. However, positively influenced the marginal adaptation and marginal staining at the 2-year follow-up. CLINICAL SIGNIFICANCE: The association of HEMA and 10-MDP monomers in the self-etching adhesives positively influence the clinical performance of the NCCL restorations with respect to marginal adaptation and marginal staining.


Assuntos
Cárie Dentária , Cimentos Dentários , Humanos , Seguimentos , Adesivos Dentinários , Resinas Compostas , Restauração Dentária Permanente/métodos , Cimentos de Resina , Cárie Dentária/etiologia , Adaptação Marginal Dentária , Colo do Dente
8.
Braz Dent J ; 34(4): 62-71, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37909643

RESUMO

This study aimed to evaluate the effect of antioxidant solutions on fracture strength and bonding performance in non-vital and bleached (38% hydrogen peroxide) teeth. One hundred and eighty dentin specimens were obtained, 60 for each test: fracture strength, hybrid layer thickness, and bond strength. The groups (n=10) were randomly composed according to post-bleaching protocol: REST - restoration, without bleaching; BL - bleaching + restoration; SA - bleaching, 10% sodium ascorbate solution, and restoration; AT - bleaching, 10% α-tocopherol solution, and restoration; CRAN - bleaching, 5% cranberry solution, and restoration; CAP - bleaching, 0.0025% capsaicin solution, and restoration. Data were analyzed with ANOVA, Kruskal-Wallis, Dunn, and Qui-Square tests (α=0.05). The highest fracture strength values were observed in REST (1508.96 ±148.15 N), without significant difference for the bleached groups (p>0.05), regardless of the antioxidant use. The hybrid layer thickness in the group that was not subjected to bleaching (REST) was significantly higher than in any other group. The bond strength in the bleached and antioxidants-treated groups (SA, AT, CRAN, CAP) has no differences with the bleached group without antioxidants (BL). Adhesive failures were predominant in the groups that did not receive the antioxidant application. In conclusion, the evaluated antioxidants did not show an effect on the fracture strength, hybrid layer thickness, or bond strength of dentin bleached after endodontic treatment. The application of 10% sodium ascorbate, 10% alpha-tocopherol, 5% cranberry, or 0.0025% capsaicin solutions is not an effective step and should not be considered for the restorative protocols after non-vital bleaching.


Assuntos
Colagem Dentária , Clareamento Dental , Antioxidantes/análise , Antioxidantes/química , Antioxidantes/farmacologia , alfa-Tocoferol/análise , alfa-Tocoferol/farmacologia , Capsaicina/análise , Capsaicina/farmacologia , Dentina/química , Ácido Ascórbico/análise , Ácido Ascórbico/química , Ácido Ascórbico/farmacologia , Clareamento Dental/métodos
9.
Braz Dent J ; 33(1): 68-76, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35262555

RESUMO

This in vitro study evaluated the anti-erosive effect of an experimental varnish containing 5% stannous chloride (SnCl2) associated with different concentrations of NaF (NaF-free, 2.5% NaF, or 5.2% NaF) on bovine enamel and root dentin. One hundred samples were pre-eroded (0.3% citric acid, pH 2.6, 10 min) and randomized into five groups (n=10 for each substrate): Negative control - milli-Q water; NaF-free - Experimental varnish SnCl2-free and NaF-free; 2.5 NaF - Experimental varnish 5% SnCl2 associated with 2.5% NaF; 5.2 NaF: Experimental varnish 5% SnCl2 associated with 5.2% NaF and positive control - Commercial varnish containing 5% NaF (Duraphat). After the varnishes were applied, the erosive and abrasive challenges were carried out for five days. Loss of tooth structure (TSL) was determined by optical profilometry, and the loss of calcium (ΔCa2+) using atomic absorption spectroscopy. Dentin analysis was also performed by SEM. A one-way ANOVA/Bonferroni test was performed to analyze the data (α=0.05). The experimental 2.5 NaF and 5.2 NaF groups showed greater effectiveness in preventing TSL when compared to the other groups (p <0.05), regardless of the substrate. In addition, these groups showed lower loss in Ca2+ content when compared to the other groups (p <0.05), for enamel and dentin. Dentin showed greater TSL and ΔCa2+ loss when compared to enamel in all treatments (p <0.05). The 5.2% and 2.5% NaF-containing experimental varnishes showed promising results in both, the prevention of TSL and the loss of Ca2+, regardless of the substrate studied.


Assuntos
Erosão Dentária , Animais , Bovinos , Esmalte Dentário , Fluoretos/farmacologia , Fluoretos Tópicos/farmacologia , Fluoreto de Sódio/farmacologia , Compostos de Estanho/farmacologia , Erosão Dentária/prevenção & controle , Raiz Dentária
10.
Int J Prosthodont ; 35(1): 109­118, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33651023

RESUMO

PURPOSE: To analyze the current evidence on the impact of surface finishing protocols (such as manual polishing or glazing) on the color stability of in vitro simulated pigmentation of CAD/CAM ceramics. MATERIALS AND METHODS: Five electronic databases were searched on February 12, 2020. In vitro experimental studies were included based on the following strategy: intervention = surface treatment of CAD/CAM ceramics with glazing agents; comparison = surface treatment of CAD/CAM ceramics with manual polishing; and outcomes = color stability. Two reviewers independently assessed the risk of bias. RESULTS: Among 1,390 articles that were screened, 6 in vitro studies were considered for qualitative analysis. Five articles confirmed changes in the color of ceramics when they were immersed in pigmented solutions. One article investigated the color stability of the samples via ultraviolet (UV) aging. Among the 6 studies analyzed, 4 showed clinically acceptable color alteration values represented by ΔE irrespective of the finishing protocol applied (glazing or mechanical polishing). Two articles presented clinically unsatisfactory color variation (ΔE > 3.3 and ΔE > 2.7) following mechanical polishing of a zirconia-reinforced lithium silicate ceramic. Coffee and red wine proved to be the beverages with the greatest potential for ceramic pigmentation. Only 1 article had a high risk of bias. CONCLUSION: For clinicians, most of the studies demonstrated that both manual polishing and glaze application can prevent significant color alterations on CAD/CAM ceramic surfaces. However, due to the relatively limited amount of evidence to support this conclusion, further studies must be conducted.


Assuntos
Cerâmica , Porcelana Dentária , Cor , Desenho Assistido por Computador , Teste de Materiais , Propriedades de Superfície
11.
J Clin Exp Dent ; 14(3): e263-e268, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35317301

RESUMO

Background: This study aimed to evaluate the bond strength and internal adaptation of customized glass fiber posts using Bulk Fill flowable composite resins (BF) and conventional composite resin. Material and Methods: Fifty bovine teeth were randomly divided (n=10) according to the following groups: G1 (control): glass fiber posts were adapted to the root canal and luted with Rely-X ARC cement (3M® ESPE); G2: fiber posts smaller than the root canal diameter were customized using Filtek™ Z350 XT (3M® ESPE) conventional composite resin, and luted similarly to Group 1. G3: posts were customized with Tetric N-Ceram Bulk Fill composite resin (Ivoclar Vivadent AG), G4: posts were customized with Filtek™ Bulk Fill Flow (3M® ESPE), and G5: posts were customized with SureFil SDRTM flow (DENTSPLY), respectively. The specimens were submitted to push-out testing and internal adaptation evaluation using optical microscopy. Push-out (MPa) and internal adaptation (%) data were subjected to ANOVA and Tukey's post-hoc tests (p = 5%). Results: No statistically significant differences were found in both evaluations (p<0.05). Conclusions: Customized glass fiber posts using different bulk fill flowable composites did not affect the post bond-strength and internal adaptation, presenting similar results to customized glass fiber posts using conventional composite or posts with no previous customization. Key words:Dental pulp, composite resins, fiber posts, glass fiber post.

12.
J Clin Exp Dent ; 13(6): e564-e571, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34188762

RESUMO

BACKGROUND: The aim of this study was to evaluate the effects of surface treatments with 1% peracetic acid (PA), solution containing 17% EDTA (SmearClear, Kerr Endodontics), solution containing a combination of 17% EDTA with 2% chlorhexidine (QMix, Dentsply Sirona) on the post-space root dentin compared to 2.5% sodium hypochlorite (NaOCl) on bond strength and resin tags length in dentin. MATERIAL AND METHODS: Forty human-canine roots were endodontically treated and the post space was prepared. The specimens were randomised into four groups (n = 10): control - irrigation with 2.5% NaOCl solution, PA - irrigation with 1% PA, SmearClear - irrigation with SmearClear solution, and QMix - irrigation with QMix solution. The fibre posts were cemented using a self-adhesive resin system (Relyx U200, 3M ESPE). After six months, the specimens were cross-sectioned and subjected to push-out and confocal laser microscopy tests. One-way ANOVA and Tukey's tests were used to analyse the data (α= 0.05). RESULTS: PA and QMix presented the highest bond strength values compared to the other groups (p< 0.05). There was no significant difference between the resin tags length in dentin by the groups (p = 0.75). CONCLUSIONS: Irrigation of the post space with 1% PA and QMix showed a positive clinical impact on the adhesion between the fiber post and root dentin. However, these materials had no influence on resin tags length in dentin by self-adhesive resin cement. Key words:Fiber post, adhesive cementation, self-adhesive resin cement, root dentin, irrigating solutions.

13.
Dental Press J Orthod ; 26(5): e2119350, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34669825

RESUMO

OBJECTIVE: The aim of this in vitro study was to evaluate the antimicrobial effect of five types of non-industrialized and industrialized probiotics on biofilms formed around orthodontic mini-implants. The null hypothesis tested was: there is no difference in the antimicrobial effect between the five types of probiotics tested around orthodontic mini-implants. METHODS: For the experiment, 120 mini-implants were immersed for seven days in Staphylococcus aureus solution for biofilm formation, and were subsequently plated in culture medium containing probiotics. The mini-implants were divided into six different groups, according to the probiotic used: G1)Lactobacillus casei; G2)Lactobacillus brevis; G3)Lactobacillus rhamnosus; G4) Lactobacillus from fermented milk Yakult®; G5) Lactobacillus from fermented milk Batavito® and G6) without use of probiotic, as negative control. Qualitative and quantitative analyses of all groups were performed using the CFU (colony forming unit) count. RESULTS: The study showed that groups G4 and G6 did not present antimicrobial activity, in comparison to groups G1, G2, G3, and G5 (p< 0.05), which demonstrated antimicrobial activity. CONCLUSION: The non-commercial probiotic bacteria, Lactobacillus casei and Lactobacillus rhamnosus, as well as commercially available fermented milk Batavito® presented promising results in the reduction of colonization of mini-implants by S. aureus. Therefore, the null hypothesis was rejected.


Assuntos
Anti-Infecciosos , Implantes Dentários , Procedimentos de Ancoragem Ortodôntica , Probióticos , Staphylococcus aureus
14.
J Clin Exp Dent ; 13(9): e913-e919, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34603620

RESUMO

BACKGROUND: This study evaluated the effects of several epoxy resin-based sealer compositions (AHP, AH Plus; ADS, Adseal; SPL, Sealer Plus) on bond strength and intratubular dentin penetration of the endodontic obturation, in root canal previously treated with calcium hydroxide intracanal medication (CH) and removed by continuous ultrasonic irrigation (CUI). MATERIAL AND METHODS: Forty-five maxillary canines were prepared up to F5 (ProTaper system), filled with CH, coronally sealed, and stored at 37ºC. After 1 week, CH was removed using 2.5% sodium hypochlorite energized by CUI. The specimens were randomly distributed in three groups (n=15) and root canal obturated, according to epoxy-based resin sealer composition (AHP, ADS or SPL). The roots were transversally sectioned in cervical, middle, and apical thirds. In each radicular third, push out bond strength using universal machine and intratubular dentin using confocal laser scanning microscopy (CLSM) and Image J Program were evaluated. Bond strength and intratubular dentin penetration were statistically evaluated by ANOVA one-way and Tukey tests and Kruskal Wallis test, respectively (α = 0.05). RESULTS: In middle and apical thirds, AHP showed higher bond strength values (p<0.05), and ADS and SPL were similar each other (p>0.05). All epoxy resin-based sealers presented similar intratubular dentin penetration, independently of the radicular thirds (p>0.05). Cohesive and mixed failures were predominant in the cervical thirds. In the middle and apical thirds, AHP showed more cohesive type failures, while ADS and SPL showed more adhesive-type failures. CONCLUSIONS: AHP has the highest bond strength in middle and apical radicular thirds, after calcium hydroxide intracanal medication removal using continuous ultrasonic irrigation, although intratubular dentin infiltration being similar among epoxy resin-based sealer with several chemical composition. Key words:Continuous ultrasonic irrigation, endodontic sealers, epoxy resin-based sealers, root canal obturation.

15.
Braz Oral Res ; 35: e084, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34431849

RESUMO

The objective of this work was to evaluate the relationship between factors associated with the COVID-19 pandemic and depression, anxiety, and stress (DAS) in dentists. Factors associated with the COVID-19 pandemic were evaluated using a questionnaire and scores of the Depression, Anxiety, and Stress Scales-21 were measured. The differences between the DAS scores based on the factors associated with the COVID-19 pandemic were tested through the successive application of multivariate analysis of variance (MANOVA, α = 0.05). After a sample size calculation, 998 participants with a mean age of 39.39 (± 11.69) years were included. The effect size indicated that changes in sleep quality (η2 = 0.161), eating habits (η2 = 0.057), and physical health (η2 = 0.051) were the ones that most negatively affected DAS scores. The highest DAS scores were observed in professionals who lived with someone at high-risk for COVID-19 (p < 0.001) and in those who did not engage in leisure activities during the pandemic (p < 0.001). Dentists who worked on the frontline against COVID-19 had higher scores of anxiety and stress (p = 0.029). The highest scores for anxiety, depression, and/or stress were seen in dentists living with someone at high-risk for COVID-19, who acts on the frontline, who does not practice in leisure activities during the pandemic, who completely changed eating habits, quality of sleep and physical health during the pandemic. In general, DAS levels of dentists were associated with factors related to the COVID-19 pandemic.


Assuntos
COVID-19 , Pandemias , Adulto , Ansiedade/epidemiologia , Odontólogos , Depressão/epidemiologia , Humanos , Pessoa de Meia-Idade , SARS-CoV-2
16.
Photodiagnosis Photodyn Ther ; 34: 102264, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33774192

RESUMO

BACKGROUND: To evaluate the effects of three protocols for removing 0.01 % methylene blue from the post space after photodynamic therapy on bond strength and tag formation in the dentin of the fiber post space, using a conventional cementation system with an etch-and-rinse or universal adhesive system. METHODS: Sixty human canines were endodontically treated for fiber post cementation. The specimens were randomized into 6 groups (n = 10): G1, G2, G3, G4, G5, and G6. The G1, G2, and G3 groups were irrigated with saline solution, 2.5 % sodium hypochlorite (NaOCl), and 2.5 % NaOCl, agitated by passive ultrasonic irrigation (PUI), respectively. In these groups, a conventional cementation system with etch-and-rinse adhesive was used. The G4, G5, and G6 groups were irrigated with the respective solutions mentioned above and cemented using a conventional cementation system with universal adhesive. Tag formation in the dentin was evaluated by confocal laser scanning microscopy. The push-out bond strength test was performed on three thirds of the specimens. RESULTS: In the cervical and middle thirds, the greatest extent of dentin tag formation occurred in the G1 (p = 0.023 and p = 0.033, respectively). In the apical third, G1, G2, and G3 demonstrated similar tag formation between themselves (p = 0.089). In the cervical and middle thirds, G4 demonstrated the highest bond strength when compared to the other groups (p < 0.05). CONCLUSION: The protocols for removing 0.01 % methylene blue with NaOCl, irrespective of the involvement of passive ultrasonic irrigation, negatively effects the bond strength and tag formation in the dentin of the post space.


Assuntos
Cimentação , Fotoquimioterapia , Animais , Dentina , Cães , Humanos , Teste de Materiais , Azul de Metileno , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Cimentos de Resina
17.
J Dent ; 103: 103498, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33069772

RESUMO

OBJECTIVE: To investigate the effectiveness of desensitizing agents (DA) on dentin hypersensitivity (DH) after non-surgical periodontal treatment (NSPT) through a systematic review and meta-analysis. DATA: The PICO strategy was used to include randomized clinical trials in human subjects with DH (P) after NSPT treated with DA (I) compared to those treated with placebo or control (C) to identify DH relief (O). The Cochrane guidelines and GRADE was used to classify the risk of bias and the quality of the evidence, respectively. SOURCES: PubMed, Web of Science, Scopus, Lilacs, Cochrane Library databases, and OpenGrey were searched on the 20th of May 2020. STUDY SELECTION: Nine studies were included in the quantitative synthesis. Five meta-analyses were performed. Three meta-analyzes assessed the effectiveness of DA compared to a placebo or control in relation to pain assessment stimuli and two meta-analyzes assessed the mechanism of action of DA. For the mechanical stimulus in overall analysis, the control group presented a higher mean of pain reduction (SMD 1.03 [0.73, 1.32], p < 0.001) with very low certainty of evidence. For water (SMD -0.78 [-1.22, -0.35], p = 0.0009) and evaporative in overall analysis (SMD -1.21 [-1.79, -0.64], p < 0.001) stimuli, the DA decreased DH pain with very low and low certainty of evidence, respectively. CONCLUSION: Due to the limited quality of evidence, there is no definitive conclusion on the effectiveness of DA on DH after NSPT. Thus, further clinical studies with a low risk of bias and high-quality evidence are encouraged to reinforce the certainty of evidence on that issue. CLINICAL SIGNIFICANCE: The use of desensitizing agents show promise for relief of dentin hypersensitivity after non-surgical periodontal therapy.


Assuntos
Dessensibilizantes Dentinários , Sensibilidade da Dentina , Dessensibilizantes Dentinários/uso terapêutico , Sensibilidade da Dentina/tratamento farmacológico , Humanos , Medição da Dor
18.
Arch Oral Biol ; 110: 104619, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31805483

RESUMO

OBJECTIVE: The aim of this study was to evaluate the morphological and chemical effect of in-office and at-home desensitising agents containing sodium fluoride (NaF) on eroded root dentine in vitro. METHODS: Fifty bovine dentine samples were pre-eroded and randomised into five groups (n = 10): G1 (Control) - milli-Q water; G2 - fluoride varnish containing NaF 22,500 ppm; G3 - desensitising cream containing NaF 9,000 ppm associated with 20% nanohydroxyapatite; G4 - toothpaste with NaF 5,000 ppm associated to tricalcium phosphate; G5 - toothpaste containing NaF 900 ppm and casein phosphopeptide-amorphous calcium phosphate fluoride (CPP-ACPF). The specimens were submitted to erosive challenge for three days. The analyses were performed using non-contact profilometry for volumetric (Sa) and linear roughness (Ra) followed by scanning electron microscopy (SEM) and Energy Dispersive X-ray Spectrometry (EDS). The data were analysed by Kruskal-Wallis and Wilcoxon tests (α = 0.05). RESULTS: There was a significant reduction of Ra and Sa for the eroded samples from the G2 and G5 (p < 0.05) after an erosive challenge. The dentine surface topography pattern showed partially or totally occluded dentinal tubules after treatments, except in the control group. The control, G4 and G3 groups showed a reduction in the dentine inorganic content percentage of Ca (Calcium) and P (Phosphorus) minerals. CONCLUSION: The fluoride varnish and CPP-ACPF toothpaste were able to prevent morphological changes and were the only materials that showed the Ca and P content increased after treatment. These materials may be promising alternatives in the clinical control of dentin erosion.


Assuntos
Dentina , Fluoreto de Sódio , Erosão Dentária , Raiz Dentária , Animais , Bovinos , Dentina/efeitos dos fármacos , Fluoretos , Fluoreto de Sódio/farmacologia , Erosão Dentária/tratamento farmacológico , Raiz Dentária/efeitos dos fármacos , Cremes Dentais
19.
PLoS One ; 14(12): e0225501, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31790452

RESUMO

OBJECTIVE: This randomized controlled clinical trial aimed to evaluate the effect of the casein phosphopeptide-amorphous calcium phosphate fluoride (CPP-ACPF) and photobiomodulation (PBM) in the treatment of dentin hypersensitivity (DH), and the impact of this on the health-related quality of life (HRQL). METHODS: Eighty teeth with DH were randomized into four groups and received three treatment sessions: PLACEBO = placebo + LASER application mimicking; CPP-ACPF = CPP-ACPF + LASER application mimicking; PBM = placebo + LASER active application; CPP-ACPF+PBM = CPP-ACPF + LASER active application. Tactile (exploratory probe) and evaporative (triple syringe) stimuli were used to measure DH and were recorded with the aid of a visual analogue scale (VAS) after the 1st, 2nd and 3rd treatment sessions and one-month follow-up. The HRQL was recorded in the DH experience questionnaire (DHEQ). RESULTS: The intragroup comparison showed a significant reduction in DH (p < 0.05) with both stimuli after one-month follow-up. The intergroup comparison with the evaporative stimulus showed that CPP-ACPF+PBM significantly reduced DH when compared to the rest of treatments, after one-month follow-up. CPP-ACPF+PBM group statistically differed from the other treatment groups in the DHEQ evaluation after one-month follow-up. CONCLUSION: After one-month follow-up, the association of CPP-ACPF with PBM was effective in the reduction of DH and promoted a positive impact on the HRQL of the participants of this study.


Assuntos
Cariostáticos/administração & dosagem , Caseínas/administração & dosagem , Sensibilidade da Dentina/terapia , Fluoretos Tópicos/administração & dosagem , Terapia com Luz de Baixa Intensidade/métodos , Adolescente , Adulto , Terapia Combinada/métodos , Sensibilidade da Dentina/complicações , Sensibilidade da Dentina/diagnóstico , Combinação de Medicamentos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Placebos/administração & dosagem , Qualidade de Vida , Resultado do Tratamento , Adulto Jovem
20.
Braz. dent. j ; 34(4): 62-71, July-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1520328

RESUMO

Abstract This study aimed to evaluate the effect of antioxidant solutions on fracture strength and bonding performance in non-vital and bleached (38% hydrogen peroxide) teeth. One hundred and eighty dentin specimens were obtained, 60 for each test: fracture strength, hybrid layer thickness, and bond strength. The groups (n=10) were randomly composed according to post-bleaching protocol: REST - restoration, without bleaching; BL - bleaching + restoration; SA - bleaching, 10% sodium ascorbate solution, and restoration; AT - bleaching, 10% α-tocopherol solution, and restoration; CRAN - bleaching, 5% cranberry solution, and restoration; CAP - bleaching, 0.0025% capsaicin solution, and restoration. Data were analyzed with ANOVA, Kruskal-Wallis, Dunn, and Qui-Square tests (α=0.05). The highest fracture strength values were observed in REST (1508.96 ±148.15 N), without significant difference for the bleached groups (p>0.05), regardless of the antioxidant use. The hybrid layer thickness in the group that was not subjected to bleaching (REST) was significantly higher than in any other group. The bond strength in the bleached and antioxidants-treated groups (SA, AT, CRAN, CAP) has no differences with the bleached group without antioxidants (BL). Adhesive failures were predominant in the groups that did not receive the antioxidant application. In conclusion, the evaluated antioxidants did not show an effect on the fracture strength, hybrid layer thickness, or bond strength of dentin bleached after endodontic treatment. The application of 10% sodium ascorbate, 10% alpha-tocopherol, 5% cranberry, or 0.0025% capsaicin solutions is not an effective step and should not be considered for the restorative protocols after non-vital bleaching.


Resumo Este estudo teve como objetivo avaliar o efeito de soluções antioxidantes na resistência à fratura e resistência de união em dentes tratados endodonticamente e clareados (38% de peróxido de hidrogênio). Cento e oitenta espécimes de dentina foram obtidos, 60 para cada teste: resistência à fratura, espessura da camada híbrida e resistência de união. Os grupos (n=10) foram compostos aleatoriamente de acordo com o protocolo pós-clareamento: REST - restauração, sem clareamento; BL - clareamento + restauração; SA - clareamento, solução de ascorbato de sódio a 10% e restauração; AT - clareamento, solução de α-tocoferol a 10% e restauração; CRAN - clareamento, solução de cranberry a 5% e restauração; CAP - clareamento, solução de capsaicina 0,0025% e restauração. Os dados foram analisados ​​com os testes ANOVA, Kruskal-Wallis, Dunn e Qui-Quadrado (α=0,05). Os maiores valores de resistência à fratura foram observados em REST (1508,96 ±148,15 N), sem diferença significativa para os grupos clareados (p>0,05), independente do uso de antioxidantes. A espessura da camada híbrida no grupo que não foi submetido ao clareamento (REST) foi significativamente maior do que em qualquer outro grupo. A resistência de união nos grupos clareado e tratado com antioxidantes (SA, AT, CRAN, CAP) não apresentou diferenças com o grupo branqueado sem antioxidantes (BL). As falhas adesivas foram predominantes nos grupos que não receberam a aplicação do antioxidante. Em conclusão, os antioxidantes avaliados não mostraram efeito sobre a resistência à fratura, espessura da camada híbrida ou resistência de união à dentina clareada após tratamento endodôntico. A aplicação de soluções de ascorbato de sódio 10%, alfa-tocoferol 10%, cranberry 5% ou capsaicina 0,0025% não é uma etapa eficaz e não deve ser considerada para os protocolos restauradores após clareamento não vital.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA