Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Med Sci Monit ; 30: e943237, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38343120

RESUMO

BACKGROUND This study evaluated the effects of milling (CADCAM), 3D printing, preparation taper angles (10-degree and 20-degree), auxiliary retentive features (groove and box), and provisional cement types (conventional and resin-based) on the adhesive failure stress of 3-mm short provisional crowns (PC). The research was motivated by the need to understand how digital dentistry technologies impact the retention and durability of provisional crowns. MATERIAL AND METHODS A total of 160 working models (3D-printed) and PCs [80 milled (CopraTemp)/80 printed (Asiga)] were fabricated from two 10- and 20-degree typodont master models and two 20-degree 3D-printed master models (groove and box), simulating a 3 mm high all-ceramic short PC. After provisional cementation with conventional (Kerr TempBond) and resin-based (ProviTemp) cements, 16 subgroups (n=10 each) underwent thermocycling (10 000 cycles; 5-55°C) and pull-off tests on a universal testing machine. Statistical analysis was performed using one-way ANOVA and post hoc Tukey test. RESULTS Conventional cement failed at lower stress for milled (47.68 to 73.54) and printed (48.40 to 77.91) as compared to resin cement for milled (104.2 to 137.27) and printed (184.85 to 328.84), respectively, with significant differences. Increased taper and groove decreased failure load except for the printed PC/resin cement combination. Use of proximal box preparation increased retention significantly. Except for 20-degree taper cemented with conventional cement, the differences in auxiliary retentive features for milled and printed provisional crowns were statistically significant at P≤0.05. CONCLUSIONS 3D-printed PC, resin-based cement, 10-degree taper, and proximal box preparation were associated with higher retention than milled, conventional cements, 20-degree taper, and vertical groove.


Assuntos
Adesivos , Cimentos de Resina , Cimentos de Resina/química , Teste de Materiais , Coroas , Impressão Tridimensional , Cimentos de Ionômeros de Vidro , Cimentos Dentários
2.
Med Sci Monit ; 30: e943404, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38374614

RESUMO

BACKGROUND Preshaded monolithic zirconia (MLZ) is reported to have high translucency. This study aimed to assess the effect of chlorhexidine gluconate (ChG) mouthwash on color and translucency parameter (TP) of 2 different preshaded MLZ dental ceramics after clinical adjustment. MATERIAL AND METHODS Two MLZ disk-shaped specimens [NPM (Nacera Pearl Multi-Shade) (n=72) and CZM (Ceramill Zolid FX Multilayer)] (n=72) were simulated for clinical adjustment, finished, and polished using 2 adjustment kits [recommended kit, third-party kit: Diasynt Plus and SUN (n=12 each)] and later immersed in ChG mouthwash (Avohex) for 2 weeks. Difference in color (ΔE) and TP (Y) were calculated using the CIELab formula after measuring the coordinates (Lab) with a colorimeter. Individual changes in color and TP were assessed on the Clinical acceptance (perceptible) threshold (CAT/CPT) and Translucency perception threshold (TPT), respectively. Differences between the 2 ceramics were assessed using one-way ANOVA and post hoc tests, with all differences considered significant at P<0.05. RESULTS NPM and CZM differed in color at baseline despite having the same Vita shade combination. Between the 2 preshaded MLZ ceramics, NPM showed significant changes in color when adjusted with a third-party kit. Chlorhexidine produced changes in color and TP that were designated as clinically perceptible (ΔE=1.0 to 3.3) on the CAT/CPT and TPT scales, irrespective of the adjustment kit used. ChG produced the least or no changes in glazed MLZ specimens. CONCLUSIONS ChG mouthwash, whenever prescribed for preshaded MLZ restoration, should be adjusted prior to final glazing to avoid clinical adjustments that adversely affects color and translucency of the restoration.


Assuntos
Clorexidina , Antissépticos Bucais , Zircônio , Cor , Clorexidina/farmacologia , Antissépticos Bucais/farmacologia , Imersão , Teste de Materiais , Propriedades de Superfície , Cerâmica , Porcelana Dentária
3.
Med Sci Monit ; 29: e941654, 2023 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-37924203

RESUMO

BACKGROUND The aim of this study was to assess and compare the vertical/horizontal dimensions and occlusal accuracy of non-working/opposing casts obtained from three different impression materials and 3D print cast. MATERIAL AND METHODS Dentulous Master models simulating a case of a fixed dental prosthesis were mounted on an articulator (control group). Opposing mandibular casts obtained from three different impression materialsand 3-dimensional print constituted test groups , ,and , respectively. Three points, anterior vertical (AV), posterior vertical (PV), and anteroposterior (AP) were compared for dimensional accuracy among casts. Occlusal accuracy was analyzed on Medit Link software at 3 teeth (#13, #17, and #27). After calculating means for each group, the differences were calculated at probability value of P≤0.05 using the single-sample t test, ANOVA, and Tukey test. RESULTS The dimensions were significantly different from those of the mounted master models except in Gp AL(E) and Gp AL(F) at AV dimension and Gp AL(E) at AP dimension (P>0.05). A statistically significant difference of the error of means among the 4 tested groupswere detected only at 2 dimensions (AV and PV) between the Gp AL(E) and Gp 3D-C and between Gp AL(F) and Gp 3D-C groups. Other groups showed no significant differences. CONCLUSIONS The opposing casts obtained from the extended-pour alginate and alginate alternative impression materials showed higher occlusal accuracy compared to conventional alginate and 3D printed casts.


Assuntos
Modelos Dentários , Impressão Tridimensional , Humanos , Alginatos , Mandíbula , Software
4.
Medicina (Kaunas) ; 59(3)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36984502

RESUMO

The coronal seal in root canal-treated teeth may be compromised depending on the accuracy of post space preparation and post cementation along with remaining gutta-percha. Root canal treatment can be compromised by endotoxins released by the coronal bacteria as a result of microleakage. The study was conducted by undergraduate students to measure the gap between the cemented post and residual gutta-percha. In total, 217 endodontically treated teeth were evaluated with intraoral peri-apical radiographs. Based on the intraoral periapical radiographic examination in the CS-R4 program, Group I had no gap, Group II had a gap of >0 to 2 mm, and Group III had a gap of more than 2 mm between the end of the cemented post and the remaining gutta-percha. In total, 40% (n = 87) of the teeth had no gap, 59% (127) had a gap of >0 to 2 mm, and 1% (n = 3) had a gap of more than 2 mm between the cemented post end and remaining gutta. Chi square test revealed a significant difference in the gap between the post and remaining gutta-percha between males and females students (p < 0.001). In terms of the gap between the cemented post end and the residual gutta-percha, the root canal treated teeth with post and core by undergraduates were clinically acceptable.


Assuntos
Materiais Restauradores do Canal Radicular , Dente não Vital , Humanos , Guta-Percha , Estudos Transversais , Estudos Retrospectivos
5.
Technol Health Care ; 2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37694329

RESUMO

BACKGROUND: Provisional fixed dental prosthesis (FDP) plays an important role during fixed prosthodontic therapy till the definitive. Discoloration of materials used for provisional FDPs can cause patient dissatisfaction and may create doubt about the color stability of the definitive FDP. Surface roughness is the other major property to be taken into consideration for provisional FDP materials. Smokeless tobacco is reported to affect the color stability and surface roughness of different prosthetic materials. OBJECTIVE: The aim of the current study was to evaluate the effect of two types of smokeless tobacco (black and white) on color stability and surface roughness of 3D printed, CAD/CAM milled, and conventional provisional FDP resin materials. METHODS: A total of 144 disc-shaped specimens were fabricated using four techniques CAD/CAM subtractive technique (milling), CAD/CAM additive technique (3D Printing), and conventional technique using autopolymerized PMMA, and autopolymerized Bis-acrylic resins. Each group was subdivided into three subgroups of twelve specimens each, and were submerged into three solutions (artificial salivary substitute, black smokeless tobacco, white smokeless tobacco). The change in color and surface roughness was evaluated and the data collected were statistically analyzed. RESULTS: It was observed that black smokeless tobacco caused the maximum color change and the effect was highest in autopolymerized PMMA resin specimens (ΔE = 9.343 ± 0.489), followed by 3D printed (ΔE = 7.187 ± 0.391), autopolymerized Bis-acryl (ΔE = 6.464 ± 0.453) and milled (ΔE = 4.978 ± 0.227). White smokeless tobacco was found to cause a maximum change in surface roughness and the effect was highest in autopolymerized Bis-acryl specimens (ΔRa = 0.321 ± 0.015 µm), followed by autopolymerized PMMA (ΔRa = 0.297± 0.015 µm), 3D printed (ΔRa = 0.191 ± 0.019 µm), and milled (ΔRa = 0.168 ± 0.014 µm). Statistically significant (p-value < 0.05) differences were observed among all techniques and solutions. CONCLUSIONS: The change in color and surface roughness were maximum in the case of FDPs prepared using autopolymerizing resins, followed by 3D printed, and CAD/CAM milled reins.

6.
Biomedicines ; 11(2)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36831026

RESUMO

Tobacco consumption in its different forms can affect the optical and surface properties of dental materials that are used in the oral cavity. Thus, the present study was conducted to evaluate the effects of two commercially available smokeless tobacco products on the color stability and surface roughness of denture base resins that were fabricated using three different techniques (CAD/CAM milling, 3D printing, and conventional heat polymerization). A total of 126 denture base resin specimens were fabricated using the three different manufacturing techniques (n = 42 each). Specimens from each group were further subdivided into three subgroups (n = 14 each) and immersed in three different immersion media (a khaini suspension, a tabbaq suspension, and artificial saliva). The differences in color and surface roughness were assessed according to data that were collected and statistically analyzed using SPSS version 24.0. The tabbaq smokeless tobacco was found to cause greatest changes in color and surface roughness; the effect was observed to be highest in the 3D-printed specimens followed by the conventional heat-polymerized and CAD/CAM milled specimens. The mean changes in color and surface roughness were the highest for the tabbaq smokeless tobacco followed by the khaini smokeless tobacco and the artificial saliva. Statistically significant (p-value < 0.05) differences were observed among all techniques and suspensions. We concluded that the mean changes in color and surface roughness were significantly higher for the 3D-printed dentures compared to the conventional heat-polymerized and CAD/CAM-milled dentures. Thus, the results of the present study strengthened the concept that tobacco in any form can lead to changes in the color and surface roughness of denture base materials.

7.
Biomedicines ; 11(2)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36831106

RESUMO

The aim of this study is to investigate the combined effect of a digital manufacturing technique (subtractive vs. additive), preparation taper (10° vs. 20° TOC), and finish line (chamfer vs. shoulder) on the marginal adaptation of temporary crowns following cementation with a compatible temporary cement. Four mandibular first molar typodont teeth were prepared for full coverage crowns with standard 4 mm preparation height as follows: 10° TOC with the chamfer finish line, 10° TOC with the shoulder finish line, 20° TOC with the chamfer finish line and 20° TOC with the shoulder finish line. Each of the four preparation designs were subdivided into two subgroups to receive CAD/CAM milled and 3D-printed crowns (n = 10). A total of 80 temporary crowns (40 CAD/CAM milled and 40 3D-printed) were cemented to their respective die using clear temporary recement in the standard cementation technique. The samples were examined under a stereomicroscope at ×100 magnification following calibration. Linear measurements were performed at seven equidistant points on each axial surface and five equidistant points on each proximal surface. One-way ANOVA analysis and Tukey HSD (Honestly Significance Difference) were performed. The best marginal fit was seen in group 8, while the poorest fit was noted in group 2. Shoulder finish lines and 10° TOC resulted in higher marginal gaps, especially in CAD/CAM milled group. The selection of 3D-printed crowns may provide a better marginal fit within the range of clinical acceptability. Marginal gaps were within clinical acceptability (50 and 120 µm) in all groups except group 2.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA