Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38255602

RESUMO

STATEMENT OF PROBLEM: Implant-supported rehabilitations are an increasingly frequent practice to replace lost teeth. Before clinical application, all implant components should demonstrate suitable durability in laboratory studies, through fatigue tests. OBJECTIVE: The purpose of this in vitro study was to evaluate the integrity and wear of implant components using SEM, and to assess the axial displacement of the implant-abutment assembly by Micro-CT, in different implant connections, after three distinct mechanical requests. MATERIALS AND METHODS: Four KLOCKNER implants (external connection SK2 and KL; and internal connection VEGA and ESSENTIAL) were submitted to three different mechanical requests: single tightening, multiple tightening, and multiple tightening and cyclic loading (500 N × 100 cycles). A total of 16 samples were evaluated by SEM, by the X-ray Bragg-Brentano method to obtain residual stresses, and scratch tests were realized for each surface and Micro-CT (4 control samples; 4 single tightening; 4 multiple tightening; 4 multiple tightening and cyclic loading). All dental implants were fabricated with commercially pure titanium (grade 3 titanium). Surface topography and axial displacement of abutment into the implant, from each group, were evaluated by SEM and Micro-CT. RESULTS: In the manufacturing state, implants and abutments revealed minor structural changes and minimal damage from the machining process. The application of the tightening torque and loading was decisive in the appearance and increase in contact marks on the faces of the hexagon of the abutment and the implant. Vega has the maximum compressive residual stress and, as a consequence, higher scratch force. The abutment-implant distances in SK2 and KL samples did not show statistically significant differences, for any of the mechanical demands analyzed. In contrast, statistically significant differences were observed in abutment-implant distance in the internal connection implants Vega and Essential. CONCLUSIONS: The application of mechanical compression loads caused deformation and contact marks in all models tested. Only internal connection implants revealed an axial displacement of the abutment into the implant, but at a general level, a clear intrusion of the abutment into the implant could only be confirmed in the Essential model, which obtained its maximal axial displacement with cyclic loading.

2.
Biomedicines ; 11(6)2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37371776

RESUMO

Dental-implant-supported reconstructions provide comfort and improvements in prosthetic function, adaptation, and stability over conventional treatment options. The objective of this study was to evaluate the effect of different denture cleansing solutions and their influence on the deterioration and loss of retention of overdenture attachments in a 12-month clinical-use simulation. In this way, ten specimens each of different brands of retentive caps made of Teflon (OT Equator® (Rhein83, Bologna, Italy), Locator® (Zest Anchors, Escondido, CA, USA), Kerator® (KJ Meditech, Gwangiu, Republic of Korea), and Locator R-Tx® (Zest Anchors, Escondido, CA, USA)) were immersed in five different cleaning solutions (Kukident® (P&G Tech, Oxford Parkway, UK), Benfix® (Laboratorios URGO S.L., Guipúzcoa, Spain), Corega® (Stafford Miller, Waterford, Ireland), and Protefix® (Neuhofer Weiche, Parchim, Germany)), and tap water was used as the control group, in a simulation that lasted 12 months. Data were analyzed using two-way ANOVA and a Tukey HSD. Furthermore, a Levene Test and Shapiro-Wilk tests were performed to assess the validation of the ANOVA assumptions. The statistical analysis was performed using R version 4.2.2 software with the significance level set to p < 0.05. There were significant statistical differences between the different manufacturers regarding the retention forces of the attachment's retentive caps (F = 322.066, p < 0.001). For the cleaning solution groups, different statistical results between Kukident® (P&G Tech, Oxford Parkway, UK) (p < 0.05) and Benfix® (Laboratorios URGO S.L., Guipúzcoa, Spain) (p < 0.05) were observed. There were no significant statistical differences between Corega® (Stafford Miller, Ireland), Protefix® (Neuhofer Weiche, Parchim, Germany), and tap water, even though the retention forces decreased in all of them.

3.
Polymers (Basel) ; 14(9)2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35566919

RESUMO

(1) Introduction: Denture adhesives (DAs) promote stability, chewing ability, and quality of life. The objective of this study was to compare the effectiveness of original brand DAs and white brands in their retention of conventional complete dentures. (2) Methods: This study followed the recommendations of the international standard ISO 10873. Three original brands of DA (Corega® Fixação 3D, GlaxoSmithKline®, Stafford Miller Ltd., Dungarvan Co. Waterford, Ireland), KuKident® Pro Procter & Gamble Technical Centres®, Ltd., Whitehal Lane, Germany and Elgydium® Fix, Laboratórios URGO® SL, Florida, Spain) were compared to three white brands (Fixação Extra Forte Pingo Doce®, Laboratórios Cosmodent®, Cantabria, Spain), Fixador de Próteses (Continente®, Propack®,Gmbh, Ladenburg, Germany) and Creme Fixador de Próteses (Auchan®, Ellipse®, Roubaix, France). Their retention capacities were analyzed using a mechanical test device. (3) Results: The mean retentive ability of original brand adhesives (M = 11.16, SD = 5.27) was significantly higher (t(298) = 11.88; p < 0.001) than that of the white brands (M = 5.92, SD = 1.18). When comparing all brands, statistically significant differences were also observed, F(5.294) = 707.68 (p < 0.001). The generic adhesive results were more homogeneous. The generic brands from Continente® (M = 5.24, SD = 0.94) and Auchan® (M = 5.80, SD = 0.79) were not significantly different, while the Pingo Doce® brand obtained significantly higher mean retention results (M = 6.71, SD = 1.28). (4) Conclusions: The original brands of DA have a significantly higher retentive ability than the white brands. Elygidim® Fix had the worst result of the three original brands, and the product from Pingo Doce® had the best result among the three white brands.

4.
Materials (Basel) ; 15(19)2022 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-36233980

RESUMO

(1) Introduction: Implant-supported fixed complete dentures are mostly composed of cantilevers. The purpose of this work was to evaluate the fracture resistance of zirconia (Prettau®, second generation, or Ice Zirkon Translucent, first generation) with cantilever lengths of 6 and 10 mm, and zirconia's fracture resistance in relation to an average bite force of 250 N. (2) Materials and methods: Forty structures were created in CAD/CAM and divided into four groups: group A (6 mm cantilever in IZT), group B (10 mm cantilever in IZT), group C (6 mm cantilever in Pz), and group D (10 mm cantilever in pz). The study consisted of a traditional "load-to-failure" test. (3) Results: A statistically significant result was found for the effect of cantilever length, t(38) = 16.23 (p < 0.001), with this having a large effect size, d = 4.68. The 6 mm cantilever length (M = 442.30, sd = 47.49) was associated with a higher mean force at break than the 10 mm length (M = 215.18, sd = 40.74). No significant effect was found for the type of zirconia: t(38) = 0.31 (p = 0.757), and d = 0.10. (4) Conclusions: All the components with cantilever lengths of 6 mm broke under forces higher than 250 N. Cantilevers larger than 10 mm should be avoided.

5.
Artigo em Inglês | MEDLINE | ID: mdl-36293951

RESUMO

Forensic dentistry plays an important role in human identification, and dental age estimation is an important part of the process. Secondary dentin deposition throughout an individual's lifetime and consequent modification in teeth anatomy is an important parameter for age estimation procedures. The aim of the present study was to develop regression equations to determine age in adults by means of linear measurements and ratios on sagittal, coronal and axial slices of maxillary central incisors using cone bean computed tomography (CBCT). Multiplanar measurements of upper central incisors were taken for a sample of 373 CBCTs. Subsequently, one-way analysis of variance (ANOVA) and multivariate linear regressions were performed for age estimation. The equations obtained from axial linear measurements and ratios presented a standard error of the estimate (SEE) of ±10.9 years (R2 = 0.49), and a SEE of ±10.8 years (R2 = 0.50), respectively. The equation obtained for multiplanar linear measurements presented a SEE of ±10.9 years (R2 = 0.52), while the equation for multiplanar ratios presented a SEE of ±10.7 years (R2 = 0.51). Thus, CBCT measurements on upper central incisors were found to be an acceptable method for age estimation. Horizontal measurements, especially pulp measurements, improve the accuracy of age estimate equations.


Assuntos
Determinação da Idade pelos Dentes , Dentina Secundária , Adulto , Humanos , Incisivo/diagnóstico por imagem , Determinação da Idade pelos Dentes/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Odontologia Legal/métodos
6.
Int J Dent ; 2021: 5133556, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34899914

RESUMO

Micromovements of the implant-abutment connection influence peri-implant bone preservation. The maximal torque after a cycle of implant prosthetic screw tightening using original components of different manufacturers and replicas produced by other companies is evaluated and quantified in this study. A total of 30 Mis Seven® standard platform implants and 30 interfaces were used, and 30 standard platform screws were tested, 10 Mis®, 10 Iconekt®, and 10 Exaktus®. The screws were tightened with an MIS® torquemeter until their respective fracture, and the fracture point was measured through the equipment's load cell, CS-Dental Testing Machine®. The screws were analyzed under an Olympus® SZ61 microscope. The fracture points were recorded and compared among all samples. To compare the mean values of the fracture torques, t-tests were performed using the reference values associated with each brand and the sample results. The variable "Place of Fracture" between the original Mis® brand and the Exaktus® replica compared to the Iconekt® replica presented a statistically significant difference (p < 0.001). When analyzing the variable "Fracture Torque," although it was verified that the replica screws (Iconekt® and Exaktus®) had a lower maximum torque, 65.11 Nm and 62.89 Nm, respectively, compared to the original Mis® brand (70 Nm and 69 Nm), there were no statistically significant differences p > 0.05. Nonoriginal screws did not present different fracture resistances compared to the original Mis® brand screws. The fracture site of Iconekt® screws showed a different pattern compared to the other brands.

7.
Polymers (Basel) ; 13(8)2021 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-33920377

RESUMO

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.

8.
Int J Dent ; 2020: 8941876, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33204269

RESUMO

METHODS: Ten prosthesis bases prepared with each brand of resin were subjected to neutral and low pH conditions (pH 7 and pH 4) by submerging them in artificial saliva for 30 days. After exposure, the fatigue resistance of the resins was tested using a Dental CS® Testing Machine. Statistical Analysis Test. The data sets were described quantitatively in terms of mean (M) and standard deviation (SD). Shapiro-Wilk tests and unilateral analysis of variance (ANOVA) were performed and complemented by Tukey's multiple comparison tests. The effect size (η2), whose cohort points followed Cohen's recommendations: 0.01 (low), 0.06 (medium), and 0.14 (high), was calculated. The results were considered significant if p < 0.05 and marginally significant if p < 0.10. RESULTS: One-way ANOVA showed that Megacryl® had the highest fracture resistance at pH 7 (52.23 Kgf), compared with Triplex Hot® (p < 0.001) and RS Vertex® (p=0.034). Two-way ANOVA confirmed the interaction between brand and pH (p=0.022), also revealing that brands comparison is significant or marginally significant, when pH is not considered (Megacryl® versus Triplex Hot®, p < 0.001, and RS Vertex®, p=0.058; Triplex Hot® versus RS Vertex®, p=0.051), and pH 7 results were significantly higher (p=0.003), even when brands are not considered. Hence, Megacryl® at pH 7 was found to have the highest fracture resistance, detached from other brands and pH values. CONCLUSION: It can be concluded within the limitations of this study that there are differences in the fracture resistance among the three brands of acrylic resin. Megacryl® was found to have the highest fracture resistance, and Triplex Hot® was the lowest. The results also show that exposure to a low pH environment decreases the fracture resistance of the Megacryl® and RS Vertex® resins.

9.
J Adv Prosthodont ; 8(1): 21-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26949484

RESUMO

PURPOSE: This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS: Three commercially available attachments were investigated: Clix®, Dalbo-Plus® and Locator®. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37℃. The abutments were placed at angulations of 0°, 10° and 20°. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS: The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F (2.48) = 343619, P<.05) and the type of attachment (F (7.48) = 23.220, P<.05). CONCLUSION: Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA