Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
World J Microbiol Biotechnol ; 38(11): 197, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-35989357

RESUMO

Low-Density Polyethylene (LDPE) is one of the significant environmental pollutants as it is resistant to natural degradation. In this study, we reported the LDPE-degrading bacterial strain i.e., Exiguobacterium sp. strain LM-IK2 isolated from plastic dumped soil which shows potential degradation capability. The percent weight loss of LDPE was calculated as - 5.70 ± 0.7 after 90 days of incubation in a carbon-free MSM medium. The Field Emission Scanning Electron Microscopy (FE-SEM) analysis shows that LDPE films show slight surface disruption after treatment with bacteria. The Fourier Transform Infrared Spectroscopy (FTIR) revealed the chemical changes in LDPE films e.g., formation and reduction of typical carbonyl peaks after incubation with bacteria. The X-Ray Diffraction (XRD) analysis displayed an increase in percent crystallinity, with a slight change in total carbon content. Genetic analysis showed the presence of Laccase (167 bp) and Alkane Hydroxylase (330 bp) genes that are responsible for LDPE degradation. Thus, Exiguobacterium sp. strain LM-IK2 has the potential to degrade LDPE and could be further explored to improve its efficiency in the bioremediation of LDPE.


Assuntos
Polietileno , Solo , Bactérias/metabolismo , Biodegradação Ambiental , Exiguobacterium , Plásticos , Polietileno/química
2.
Pak J Pharm Sci ; 31(1): 83-87, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29348088

RESUMO

The current study was designed in order to elucidate the most sensitive method for daily practice as well as to evaluate the risk factors for HCV infection associated with blood transfusion in District Peshawar. A total of 1400 healthy volunteer blood donors were tested for Anti-HCV. A questionnaire was used to evaluate the risk factors. Initial testing of all blood samples was done by Immuno Chromatographic Technique (ICT) and confirmed by micro particle enzyme immunoassay (MEIA) and Enzyme Linked Immunosorbent Assay (ELISA). The comparison among ICT, ELISA and MEIA techniques was also evaluated for the purpose of sensitivity. Among 1400 blood donors, 26 (1.85%) cases were found positive for Anti-HCV. These 26 cases were positive on MEIA, 16 individuals were positive on ELISA while 14 were positive on ICT. These 26 cases had different histories of dental treatment (50%), traveled abroad (23.07%), surgery (11.53%), blood transfusion (7.69%) and unknown reason (7.69%). Among all these different histories of dental treatment and blood transfusion were the main risk factors for HCV infection. The results revealed that MEIA is a quick and reliable technique for routine screening of blood donors particularly for controlling the spread of HCV.


Assuntos
Doadores de Sangue , Anticorpos Anti-Hepatite C/sangue , Hepatite C/sangue , Hepatite C/epidemiologia , Adulto , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Paquistão/epidemiologia , Prevalência , Fatores de Risco , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA