Gastrointest Endosc ; 89(1): 115-123, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30125574

RESUMO

BACKGROUND AND AIMS: Studies from our group and others demonstrate residual fluid in 42% to 95% of endoscope working channels despite high-level disinfection and drying. Additionally, persistent simethicone has been reported in endoscope channels despite reprocessing. METHODS: Endoscopy was performed by using water or varied simethicone concentrations (0.5%, 1%, 3%) for flushing. After high-level disinfection/drying, we inspected endoscope working channels for retained fluid by using the SteriCam borescope. Working channel rinsates were evaluated for adenosine triphosphate (ATP) bioluminescence. Fourier transform infrared spectroscopy was performed on fluid droplets gathered from a colonoscope in which low-concentration simethicone was used. RESULTS: Use of medium/high concentrations of simethicone resulted in a higher mean number of fluid droplets (13.5/17.3 droplets, respectively) and ATP bioluminescence values (20.6/23 relative light units [RLUs], respectively) compared with that of procedures using only water (6.3 droplets/10.9 RLUs; P < .001). Two automated endoscope reprocessing cycles resulted in return of a fluid droplet and ATP bioluminescence values to ranges similar to that of procedures that used only water (P = .56). Low-concentration simethicone did not increase the mean residual fluid or ATP bioluminescence values compared with procedures that used only water (5.8 droplets/15.6 RLUs). Fourier transform infrared analysis revealed simethicone in the endoscope working channel after use of low-concentration simethicone. CONCLUSIONS: Use of medium/high concentrations of simethicone is associated with retention of increased fluid droplets and higher ATP bioluminescence values in endoscope working channels, compared with endoscopes in which water or low concentration simethicone was used. However, simethicone is detectable in endoscopes despite reprocessing, even when it is utilized in low concentrations. Our data suggest that when simethicone is used, it should be used in the lowest concentration possible. Facilities may consider 2 automated endoscope reprocessor cycles for reprocessing of endoscopes when simethicone has been used.


Assuntos
Antiespumantes/análise , Endoscópios Gastrointestinais , Simeticone/análise , Trifosfato de Adenosina , Colonoscópios , Desinfecção/métodos , Gastroscópios , Humanos , Medições Luminescentes , Espectroscopia de Infravermelho com Transformada de Fourier
2.
Gastrointest Endosc ; 77(3): 319-27, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23410693

RESUMO

Biliary and pancreatic stents are used in a variety of benign and malignant conditions including strictures and leaks and in the prevention of post-ERCP pancreatitis.Both plastic and metal stents are safe, effective, and easy to use. SEMSs have traditionally been used for inoperable malignant disease. Covered SEMSs are now being evaluated for use in benign disease. Increasing the duration of patency of both plastic and metal stents remains an important area for future research.


Assuntos
Doenças Biliares/cirurgia , Pancreatopatias/cirurgia , Stents , Colangiopancreatografia Retrógrada Endoscópica , Desenho de Equipamento , Humanos , Metais , Plásticos , Stents/efeitos adversos , Stents/economia