RESUMO
Background: Head and neck free flap survival relies on adequate tissue perfusion from the external carotid artery (ECA), and vessel length is inversely proportional to blood flow rate. Objective: Investigate whether distance from the ECA (as a proxy for pedicle vessel length) predicts flap survival or complications. Methods: Retrospective review of free flaps performed at three academic centers from 9/2006 to 8/2021. Flaps were categorized by distance from the ECA: orbit and above (zone 1), maxilla to parotid (zone 2), and mandible and below (zone 3). Secondary analysis assessed flap outcomes stratified by average historical pedicle length. Results: A total of 2,369 flaps were identified in zones 1 (n = 109), 2 (n = 1878), and 3 (n = 382). Rates of flap failure (4.9%) and perioperative complications (36.3%) did not differ by zone or pedicle length. Zone 3 flaps, most commonly located in the larynx and hypopharynx, had significantly higher rates of fistula and infection. Conversely, 30-day readmission rates were significantly lower in patients with zone 2 flaps (p < 0.001). Rates of all other complications did not differ significantly between zones. Conclusions: Proximity to mucosal anatomic sites was a more powerful predictor of free flap viability than pedicle length or ECA proximity.
Assuntos
Retalhos de Tecido Biológico , Neoplasias de Cabeça e Pescoço , Procedimentos de Cirurgia Plástica , Humanos , Neoplasias de Cabeça e Pescoço/cirurgia , Pescoço/cirurgia , Cabeça/cirurgiaRESUMO
OBJECTIVE: To evaluate the current quality and utility of clinical practice guidelines (CPGs) issued for the diagnosis, prevention, and treatment of medication-related osteonecrosis of the jaw (MRONJ). STUDY DESIGN: We performed a systematic literature search of guidelines for MRONJ diagnosis, staging, prevention, or management. An appraisal of guidelines was completed using the Appraisal of Guidelines for Research and Evaluation (AGREE II) instrument. Scaled domain scores were calculated for each domain. Key recommendations were abstracted from guidelines distinguished as "high" quality. RESULTS: Six CPGs were identified from systematic review. Four of 6 (66.7%) guidelines were published within the last 2 years. Each guideline discussed management of antiresorptive and antiangiogenic therapy-associated osteonecrosis of the jaw. The highest-scoring domain was domain 1: "Scope and purpose," with an average score of 85.0% (range: 76.4%-100.0%). The lowest domain score was in domain 5: "Applicability," with an average score of 41.7% (range: 22.9%-92.7%). Only 2 guidelines (33.3%) met the quality threshold of > 60% in 5 or more AGREE II domains, distinguishing them as "high"-quality guidelines. The average kappa statistic calculated across domains was 0.77, suggesting substantial interrater correlation in the CPG appraisal process. CONCLUSIONS: Despite the increasing recognition of MRONJ as a debilitating consequence of antiresorptive and antiangiogenic therapy, clinical guideline recommendations may be lacking in overall quality and clinical utility.
RESUMO
BACKGROUND: Rigid bronchoscopy intubation poses a significant risk of complication to patients from mechanical trauma. Despite the importance of precision in forces exerted by surgeons during intubation, no prior study has analyzed the overall forces and torques involved in rigid bronchoscopy intubation, and whether existing training modalities accurately replicate them. METHODS: A bronchoscope was equipped with a 6-axis load sensor to measure forces and torques applied during rigid bronchoscopy intubation. The device was applied to measure intubation forces in low-fidelity manikins and patients by interventional pulmonologists. RESULTS: Axial and lateral forces were measured during rigid bronchoscope intubation from the mouth to the mid-trachea. The mean axial/lateral forces recorded during manikin trials were 6.93/18.06 N, whereas those recorded during patient trials were 4.57/9.43 N. Average axial and lateral force application was therefore 51.6% and 92.6% higher in manikin, respectively. Applied axial torque averaged across all human trials was 130.5 N-mm compared with 78.3 N-mm for manikin trials, 40% lower in manikin than in human. Lateral torque application during manikin intubation showed greater variation in between trials and a greater range of SDs within trials. CONCLUSION: This was the first application of a rigid bronchoscope measurement device designed to measure forces applied at the handle. Force and torque discrepancies between manikin training and patient applications were found, indicating a possible mismatch between the haptic feedback received by physicians during rigid training and application. This inconsistency could be resolved via novel haptic training modalities and help increase atraumatic intubations.