Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 103(4): 532-538, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38415895

RESUMO

BACKGROUND: Studies evaluating the safety and efficacy of drug coating balloons (DCB) for the treatment of lesions in large coronary vessel are limited. AIMS: Our study aimed to evaluate the performance of a sirolimus DCB in large coronary arteries. METHODS: We analyzed all the procedures included in the EASTBOURNE Registry (NCT03085823) enrolling patients with a clinical indication to percutaneous coronary intervention performed by a sirolimus DCB according to investigator judgment. In the present analysis, a cut-off of 2.75 mm was used to define large coronary arteries. Primary endpoint of the study was clinically driven target lesion revascularization (TLR) at 24 months whereas secondary endpoint included procedural success, myocardial infarction (MI), cardiac death and total mortality. RESULTS: Among the 2123 patients and 2440 lesions enrolled in the EASTBOURNE study between 2016 and 2020, 757 patients/810 lesions fulfilled the criteria for the present analysis. Mean reference vessel diameter was 3.2 ± 0.3 mm with mean lesion length of 22 ± 7 mm. Procedural success was high (96%) and at 2-year follow up the device showed a good efficacy with a TLR rate of 9%. There were 34 deaths (4.5%), 30 MIs (4%) and 8 BARC type 3-5 bleedings (1.1%). In-stent restenosis (629 lesions) and de novo lesions (181) were associated with 11% and 4% rates of TLR at 2 years, respectively (p = 0.003). CONCLUSIONS: Clinical performance of a sirolimus DCB in large coronary artery vessels shows promising signals at 2-year follow up, both in de novo and in-stent restenosis lesions.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Sirolimo/efeitos adversos , Resultado do Tratamento , Angiografia Coronária , Materiais Revestidos Biocompatíveis
2.
J Cardiovasc Med (Hagerstown) ; 22(2): 94-100, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32740442

RESUMO

AIMS: The purpose of the EASTBOURNE registry is to evaluate the immediate and long-term clinical performance of a novel sirolimus-coated balloon (SCB) in a real-world population of patients with coronary artery disease. We here present the prespecified interim analysis after the enrollment of the first 642 patients who obtained 1-year clinical follow-up. METHODS: EASTBOURNE is a prospective, international, multicenter, all-comer investigator-driven clinical registry, which is enrolling consecutive patients treated with SCB at 42 European and Asiatic centers. Primary study endpoint is target-lesion revascularization (TLR) at 12 months. Secondary endpoints are procedural success and major adverse cardiac events through 36 months. RESULTS: Diabetes mellitus was present in 41% of patients. Acute coronary syndrome was present in 45% of patients and de novo lesions were 55%; 83% of the in-stent restenosis (ISR) patients had drug-eluting stents restenosis. Lesion predilatation was performed in 95% of the cases and bailout stenting occurred in 7.5%. So far, 642 patients have a complete 12-month follow-up. TLR occurred in 2.5%, myocardial infarction in 2.3%, total death in 1% and major adverse cardiac events in 5.8% of patients. A prespecified analysis of comparison between ISR and de-novo lesions showed a significantly higher occurrence of TLR in the ISR population (5.4 vs. 0.2%, P = 0.0008). CONCLUSION: The current interim analysis of 12-month follow-up of the EASTBOURNE registry shows good immediate performance and an adequate and encouraging safety profile through 12 months for this novel SCB.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Sistema de Registros , Sirolimo/farmacologia , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Int J Cardiol ; 258: 36-41, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29426631

RESUMO

BACKGROUND: We aimed to evaluate the mid-term outcomes of a novel thin-strut bioresorbable-polymer sirolimus-eluting stent (BP-SES) in chronic total occlusion (CTO) percutaneous coronary intervention (PCI), as compared with durable-polymer everolimus-eluting stents (EES). METHODS: We compiled a multicenter registry of patients undergoing CTO recanalization followed by BP-SES or EES implantation. The primary endpoint was the incidence of target-lesion failure (TLF, a composite of cardiac death, target-vessel myocardial infarction, and target-lesion revascularization) at one year. Propensity score matching (PSM) was used to adjust for case mix. RESULTS: Overall, 413 patients were included (BP-SES n = 242, EES n = 171). PSM resulted in 131 matched pairs, which represented the subject of the main analysis. Antegrade wire escalation was the most successful crossing technique (66% vs. 63%, p = 0.98) in both the BP-SES and EES groups, respectively. Procedural success rates were similar between groups (BP-SES 96% vs. EES 93%, p = 0.24). At one-year follow-up, there were no differences in the primary endpoint of TLF (5.7% vs. 8.3%, p = 0.44), and in cardiac death (0.9% vs. 2.8%, p = 0.32), target-vessel myocardial infarction (0.9% vs 1.9%, p = 0.57), target-lesion revascularization (3.7% vs 3.7%, p = 0.99), or stent thrombosis (0.9% vs. 1.9%, p = 0.57), in BP-SES vs. EES, respectively. CONCLUSIONS: Patients undergoing CTO PCI with BP-SES suffer a low rate of TLF at one-year follow-up, which is similar to that of subjects treated with durable-polymer EES.


Assuntos
Implantes Absorvíveis/tendências , Oclusão Coronária/cirurgia , Stents Farmacológicos/tendências , Intervenção Coronária Percutânea/tendências , Polímeros/administração & dosagem , Sirolimo/administração & dosagem , Idoso , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Resultado do Tratamento
4.
Circ Cardiovasc Interv ; 9(10)2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27765802

RESUMO

BACKGROUND: There is little evidence regarding the efficacy and safety of bioresorbable scaffolds (BRS) for the percutaneous treatment of chronic total occlusions. METHODS AND RESULTS: We performed a multicenter registry of consecutive chronic total occlusion patients treated with BRS (Absorb; Abbott Vascular) and second-generation drug-eluting stents (DES) at 5 institutions. Long-term target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, and ischemia-driven target-lesion revascularization) was the primary end point. Inverse probability of treatment weight-adjusted Cox regression was used to account for pretreatment differences between the 2 groups. A total of 537 patients (n=153 BRS; n=384 DES) were included. BRS patients were younger and had lower prevalence of comorbidities. Overall mean Japan-Chronic Total Occlusion (J-CTO) score was 1.43±1.16, with no differences between groups. Procedural success was achieved in 99.3% and 96.6% of BRS- and DES-treated patients, respectively (P=0.07). At a median follow-up of 703 days, there were no differences in target-vessel failure between BRS and DES (4.6% versus 7.7%; P=0.21). By adjusted Cox regression analysis, there were still no significant differences between BRS and DES (hazard ratio, 1.54; 95% confidence interval, 0.69-3.72; P=0.34). However, secondary analyses suggested a signal toward higher ischemia-driven target-lesion revascularization with BRS. CONCLUSIONS: Implantation of BRS versus second-generation DES in chronic total occlusion was associated with similar risk of target-vessel failure at long-term follow-up. However, a signal toward increased ischemia-driven target-lesion revascularization with BRS was observed. Large randomized studies should confirm these findings.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Oclusão Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Distribuição de Qui-Quadrado , Doença Crônica , Comorbidade , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Pontuação de Propensão , Modelos de Riscos Proporcionais , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA