Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Lancet ; 392(10154): 1235-1245, 2018 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-30253879

RESUMO

BACKGROUND: During the past decade, many patients had zotarolimus-eluting stents implanted, which had circular shape cobalt-chromium struts with limited radiographic visibility. The Resolute Onyx stent was developed to improve visibility while reducing strut thickness, which was achieved by using a novel composite wire with a dense platinum-iridium core and an outer cobalt-chromium layer. We did the first randomised clinical trial to assess the safety and efficacy of this often-used stent compared with the Orsiro stent, which consists of ultrathin cobalt-chromium struts. METHODS: We did an investigator-initiated, assessor-blinded and patient-blinded, randomised non-inferiority trial in an allcomers population at seven independently monitored centres in Belgium, Israel, and the Netherlands. Eligible participants were aged 18 years or older and required percutaneous coronary intervention with drug-eluting stents. After guide wire passage with or without predilation, members of the catheterisation laboratory team used web-based computer-generated allocation sequences to randomly assign patients (1:1) to either the Resolute Onyx or the Orsiro stent. Randomisation was stratified by sex and diabetes status. Patients and assessors were masked to allocated stents, but treating clinicians were not. The primary endpoint was target vessel failure at 1 year, a composite of cardiac death, target-vessel-related myocardial infarction, and target vessel revascularisation, and was assessed by intention to treat (non-inferiority margin 2·5%) on the basis of outcomes adjudicated by an independent event committee. This trial is registered with ClinicalTrials.gov, number NCT02508714. FINDINGS: Between Oct 7, 2015, and Dec 23, 2016, 2516 patients were enrolled, 2488 of whom were included in the intention-to-treat analysis (28 withdrawals or screening failures). 1243 participants were assigned to the Resolute Onyx group, and 1245 to the Orsiro group. Overall, 1765 (70·9%) participants presented with acute coronary syndromes and 1275 (51·2%) had myocardial infarctions. 1-year follow-up was available for 2478 (99·6%) patients. The primary endpoint was met by 55 (4·5%) patients in the Resolute Onyx group and 58 (4·7%) in the Orsiro group. Non-inferiority of Resolute Onyx to Orsiro was thus established (absolute risk difference -0·2% [95% CI -1·9 to 1·4]; upper limit of the one-sided 95% CI 1·1%; pnon-inferiority=0·0005). Definite or probable stent thrombosis occurred in one (0·1%) participant in the Resolute Onyx group and nine (0·7%) in the Orsiro group (hazard ratio 0·11 [95% CI 0·01-0·87]; p=0·0112). INTERPRETATION: The Resolute Onyx stent was non-inferior to Orsiro for a combined safety and efficacy endpoint at 1-year follow-up in allcomers. The low event rate in both groups suggests that both stents are safe, and the very low rate of stent thrombosis in the Resolute Onyx group warrants further clinical investigation. FUNDING: Biotronik and Medtronic.


Assuntos
Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Desenho de Prótese , Implantes Absorvíveis , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas de Cromo , Stents Farmacológicos/efeitos adversos , Estudos de Equivalência como Asunto , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
2.
Am Heart J ; 198: 25-32, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29653644

RESUMO

AIM: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent. METHODS AND RESULTS: The BIONYX trial (ClinicalTrials.gov-no.NCT02508714) is an investigator-initiated, prospective, randomized, patient- and assessor-blinded, international, multicenter study in all-comer patients with all types of clinical syndromes and lesions who require percutaneous coronary interventions with DES. Patients at 7 study sites in the Netherlands, Belgium, and Israel were randomly assigned (1:1, stratified for gender and diabetes mellitus) to treatment with the novel, zotarolimus-eluting, durable polymer-coated Resolute Onyx stent that has a radiopaque, thin-strut, CoreWire stent platform versus the sirolimus-eluting, bioresorbable polymer-coated Orsiro stent (reference device) that has a very thin-strut, cobalt-chromium stent backbone. The primary end point is the 1-year incidence of the composite clinical end point target vessel failure consisting of cardiac death, target vessel-related myocardial infarction, or clinically indicated target vessel revascularization. A power calculation, assuming a target vessel failure rate of 6.0% (noninferiority margin 2.5%), revealed that 2,470 study patients would give the study 80% power (α level 5%), allowing for up to 3% loss to follow-up. The first patient was enrolled on October 7, 2015; on December 23, 2016, the last patient entered the study. CONCLUSIONS: BIONYX is a large-scale, prospective, randomized, international, multicenter trial comparing a novel DES with durable coating versus a reference DES with biodegradable coating in all-comers. The study is the first randomized assessment of the Resolute Onyx stent, which is an often-used DES outside the United States.


Assuntos
Implantes Absorvíveis , Estenose Coronária/cirurgia , Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Bélgica , Materiais Revestidos Biocompatíveis , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Internacionalidade , Israel , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Países Baixos , Segurança do Paciente/estatística & dados numéricos , Intervenção Coronária Percutânea/métodos , Polímeros , Estudos Prospectivos , Medição de Risco , Método Simples-Cego , Sirolimo/farmacologia , Estatísticas não Paramétricas , Taxa de Sobrevida , Resultado do Tratamento
3.
Int J Cardiol ; 325: 37-44, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33148427

RESUMO

BACKGROUND: Patients with diabetes have more extensive coronary disease, resulting in higher risks of adverse clinical events following stenting. In all-comer patients, contemporary DES have shown excellent safety and efficacy, but data on diabetic patients are scarce. Separately for the BIO-RESORT and BIONYX trials, we assessed the 2-year clinical outcomes of diabetic patients, treated with various contemporary drug-eluting stents (DES). METHODS: We performed two prespecified secondary analyses of two randomized DES trials, which both stratified for diabetes. The main endpoint was target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization. Follow-up was finished before the COVID-19 pandemic. RESULTS: In BIO-RESORT, 624/3514 (17.8%) had diabetes: 211 received Orsiro sirolimus-eluting stents (SES), 203 Synergy everolimus-eluting stents (EES), and 210 Resolute Integrity zotarolimus-eluting stents (RI-ZES). TVF did not differ between SES (10.2%) and EES (10.0%) versus RI-ZES (12.7%) (SES vs. RI-ZES HR:0.78, 95%-CI [0.44-1.40]; p = 0.40, EES vs. RI-ZES HR:0.79, 95%-CI [0.44-1.40]; p = 0.42). In BIONYX, 510/2488 (20.5%) patients had diabetes: 250 received SES and 260 Resolute Onyx zotarolimus-eluting stents (RO-ZES). There was no difference in TVF between SES (10.7%) versus RO-ZES (12.2%) (HR:0.88, 95%-CI [0.52-1.48]; p = 0.63). CONCLUSIONS: There was no difference in 2-year clinical outcome among patients with diabetes, who were treated with SES, or EES, versus RI-ZES. In addition there was no difference in clinical outcome in diabetic patients, who were treated with SES versus RO-ZES. These findings may be considered as a signal of safety and efficacy of the studied DES in patients with diabetes.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Stents Farmacológicos , Everolimo/administração & dosagem , Sirolimo/análogos & derivados , Plásticos Biodegradáveis , Humanos , Estudos Multicêntricos como Assunto , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Projetos de Pesquisa , Sirolimo/administração & dosagem
4.
EuroIntervention ; 13(18): e2147-e2151, 2018 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-29278354

RESUMO

AIMS: The aim of this study was to evaluate the five-year clinical results of a sirolimus-eluting stent (MiStent SES) with a bioabsorbable coating designed for sustained drug delivery during and after rapid polymer dissolution. METHODS AND RESULTS: The five-year results from the DESSOLVE I and II trials including major adverse cardiac events (MACE), target lesion failure (TLF), target vessel failure (TVF), and stent thrombosis (ST) at five-year follow-up are reported. In DESSOLVE I, 10.3% of patients receiving the MiStent SES (3/29) had a MACE event up to five years without TLF. In DESSOLVE II, 15.1% of patients in the MiStent group (18/119) had a five-year MACE event compared to 22.0% of patients in the Endeavor group (p=0.295). TLF was 9.2% in the MiStent group and 8.5% in the Endeavor group (p=1.00). TVF was 10.1% for MiStent versus 15.3% for Endeavor (p=0.331). Up to five-year follow-up, the MiStent SES has continued to demonstrate low rates of TLR across DESSOLVE I (0.0%) and DESSOLVE II (3.4%). No ST was reported with the MiStent up to five years in the DESSOLVE I trial. In DESSOLVE II, definite or probable ST was 0.0% with MiStent and 1.7% with Endeavor up to five years. CONCLUSIONS: The MiStent SES demonstrated long-term safety and effectiveness with low rates of five-year MACE, TLF, and TVF across these two clinical trials.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Cristalização , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
5.
EuroIntervention ; 12(5): e574-83, 2016 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-27497357

RESUMO

AIMS: Our aim was to assess vascular response after polymer-free sirolimus-eluting stent (SES) implantation by using an optical coherence tomography (OCT)-derived vascular healing score (HS), quantifying the deficiency of healing. METHODS AND RESULTS: In a prospective, multicentre, single-arm, open-label study, OCT examinations were performed at three months in 45 patients (47 lesions). Per protocol, 24 lesions which had not reached adequate vascular healing according to study criteria were scheduled for OCT examination at six months. The HS was calculated at two time points. Serial OCT imaging demonstrated that the proportion of covered stent struts increased from a median of 87.1% at three months to 98.6% at six months (p<0.001). The neointimal thickness increased from a median of 82.8 µm to 112.2 µm (p<0.001), whereas the median percentages of malapposed struts were 0.2% and 0.0% at the two respective time points. Neointimal volume obstruction increased from 6.3% to 12.8%, and the HS decreased from a median of 28.1 at three months to 2.4 at six months. CONCLUSIONS: In patients who had inadequate vascular healing three months after polymer-free SES implantation, serial OCT showed almost complete vascular healing at six months.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/uso terapêutico , Estenose Coronária/terapia , Stents Farmacológicos , Neointima/terapia , Sirolimo/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/patologia , Intervenção Coronária Percutânea , Polímeros/uso terapêutico , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica/métodos
6.
EuroIntervention ; 10(12): 1383-90, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24801119

RESUMO

AIMS: To compare the efficacy and safety of the MiStent absorbable polymer sirolimus-eluting stent (APSES) with a zotarolimus-eluting stent (ZES). METHODS AND RESULTS: The trial was a 2:1 randomisation at 26 sites of 184 patients implanted with an APSES (n=123) versus a ZES (n=61). Following stent implantation, all patients underwent quantitative coronary angiography at baseline and at nine months of follow-up, while a select subgroup also underwent optical coherence tomography (OCT). The primary efficacy hypothesis was superiority of in-stent late lumen loss (LLL) of APSES compared to ZES. At nine months, the primary endpoint was met, with a mean in-stent LLL of 0.27±0.46 mm in 103 APSES patients versus 0.58±0.41 mm in 52 ZES patients (p<0.001). The proportion of uncovered stent struts by OCT at nine months was very low in both groups. The mean neointimal thickness of covered struts (p=0.002) and percent net volume obstruction (p≤0.003) were significantly lower in the APSES than in the ZES group. Major adverse cardiac event and stent thrombosis rates were low and comparable between groups. CONCLUSIONS: The DESSOLVE II trial demonstrated superiority in the primary efficacy endpoint of nine-month mean LLL for APSES compared to ZES. Strut coverage by OCT was high with both stents and the clinical safety endpoints including stent thrombosis were equally low in both groups. ClinicalTrials.gov Identifier: NCT01294748.


Assuntos
Implantes Absorvíveis , Antibióticos Antineoplásicos/uso terapêutico , Reestenose Coronária/patologia , Estenose Coronária/terapia , Stents Farmacológicos , Neointima/patologia , Intervenção Coronária Percutânea/métodos , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Idoso , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/diagnóstico por imagem , Polímeros , Método Simples-Cego , Tomografia de Coerência Óptica , Resultado do Tratamento
7.
Atherosclerosis ; 219(1): 245-52, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21763653

RESUMO

OBJECTIVE: To assess the safety and efficacy of the Genous™ endothelial progenitor cell (EPC) capturing stent in conjunction with HmG-CoA-reductase inhibitors (statins) to stimulate EPC recruitment, in the treatment of patients with de novo coronary artery lesions. METHODS AND RESULTS: The HEALING IIB study was a multi-center, prospective trial, including 100 patients. The primary efficacy endpoint was late luminal loss by QCA at 6-month follow-up (FU). Although statin therapy increased relative EPC levels by 5.6-fold, the angiographic outcome at 6 month FU was not improved in patients with an overall in-stent late luminal loss of 0.76±0.50 mm. The composite major adverse cardiac events (MACE) rate was 9.4%, whereas 6.3% clinically justified target lesion revascularizations (TLRs) were observed. 2 Patients died within the first 30 days after stent implantation due to angiographically verified in-stent thrombosis. At 12 month FU, MACE and TLR increased to 15.6% and 11.5% respectively and stabilized until 24 month FU. 18 Month angiographic FU showed a significant decrease in late luminal loss (0.67±0.54, 11.8% reduction or 10% by matched serial analysis, P=0.001). CONCLUSION: The HEALING IIB study suggests that statin therapy in combination with the EPC capture stent does not contribute to a reduction of in-stent restenosis formation for the treatment of de novo coronary artery disease. Although concomitant statin therapy was able to stimulate EPC recruitment, it did not improve the angiographic outcome of the bio-engineered EPC capture stent. Remarkably, angiographic late loss was significantly reduced between 6 and 18 months.


Assuntos
Antígenos CD34/imunologia , Doença da Artéria Coronariana/terapia , Reestenose Coronária/prevenção & controle , Ácidos Heptanoicos/uso terapêutico , Pirróis/uso terapêutico , Stents , Adulto , Idoso , Atorvastatina , Movimento Celular , Materiais Revestidos Biocompatíveis , Intervalo Livre de Doença , Stents Farmacológicos/efeitos adversos , Células Endoteliais/imunologia , Células Endoteliais/fisiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Células-Tronco/fisiologia , Stents/efeitos adversos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 62(1): 18-25, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15103594

RESUMO

This study should clarify whether the gold-coated NIROYAL stent is equivalent to the stainless steel NIR stent. Patients were randomized to either NIR stent (n = 298) or a NIROYAL stent (n = 305). The primary endpoint was the minimum lumen diameter of the target lesion at 6 months postprocedure. Secondary endpoints focused on clinical events. At 30 days, adverse events were similar in both groups. At 6 months, the minimal lumen diameter was 1.83/1.64 mm (P < 0.001; 95% CI = 0.08-0.30) and the angiographic restenosis rate was 20.6%/37.7% (P < 0.001; 95% CI = -24.7 to -9.3) for NIR/NIROYAL. The 6-month MACE rates were NIR 7.4% and NIROYAL 10.5% (95% CI = -7.7 to 1.4). Compared to stainless steel stent, the NIROYAL stent demonstrated a smaller minimal lumen diameter, a higher late loss (i.e., higher neointimal hyperplasia in spite of a significantly better initial gain), with higher restenosis and similar MACE rates at 6 months.


Assuntos
Materiais Revestidos Biocompatíveis/farmacocinética , Ouro/farmacocinética , Stents , Idoso , Angioplastia Coronária com Balão , Implante de Prótese Vascular , Angiografia Coronária , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Estenose Coronária/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Análise de Sobrevida , Equivalência Terapêutica , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA