Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Arthroplasty ; 26(8): 1571.e11-3, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21802249

RESUMO

Although often a benign complication of total hip arthroplasty, cement extrusion can cause nerve, vessel, and organ compression. We report the case of a 70-year-old male patient in whom an extruded cement mass migrated anteriorly and compressed the femoral nerve and impinged on the femoral artery producing acute, severe groin pain with neuralgia 9 years postoperatively. Paresthesia of the anterior and medial thigh was found on examination. Radiographic, ultrasound, and computed tomographic studies confirmed a 6 × 1.5-cm mass of bone cement in the right groin compressing the femoral nerve that was removed successfully at surgery. Six months postoperatively, the patient's pain had resolved, but hyperesthesia of the medial thigh remained.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos/efeitos adversos , Migração de Corpo Estranho/complicações , Virilha , Síndromes de Compressão Nervosa/etiologia , Complicações Pós-Operatórias , Idoso , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Seguimentos , Migração de Corpo Estranho/diagnóstico , Migração de Corpo Estranho/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Masculino , Síndromes de Compressão Nervosa/diagnóstico , Síndromes de Compressão Nervosa/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
Gait Posture ; 26(1): 120-7, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17010610

RESUMO

Certain typical gait characteristics such as foot-drop and foot supination are well described in Charcot-Marie-Tooth disease. These are directly related to the primary disease and due to the weakness of ankle dorsiflexors and everters characteristic of this hereditary neuropathy. We analysed 16 subjects aged 8-52 years old (11 with type I, 5 with type II Charcot-Marie-Tooth disease) using three-dimensional gait analysis and identified kinematic features previously unreported. These patients showed a combination of tight tendo achillei, foot-drop, failure of plantar flexion and increased foot supination, but also presented with excessive internal rotation of the knee and/or tibia, knee hyperextension in stance, excessive external rotation at the hips and decreased hip adduction in stance (typical of a broad based gait). These proximal features could have been an adaptation to or consequence of the disrupted ankle and foot biomechanics, however a direct relation to the neuropathy is also possible since sub-normal muscle power was observed at the proximal levels in most subjects on both manual testing and kinetic analysis. Gait analysis is a useful tool in defining the characteristic gait of patients with Charcot-Marie-Tooth disease.


Assuntos
Doença de Charcot-Marie-Tooth/fisiopatologia , Marcha/fisiologia , Adolescente , Adulto , Tornozelo/fisiopatologia , Criança , Feminino , Pé/fisiopatologia , Quadril/fisiopatologia , Humanos , Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Rotação
3.
Biomaterials ; 26(24): 4993-5001, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15769535

RESUMO

The wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular components in total hip replacements (THRs) has been shown to be highly dependent on the direction of shear. Greatly reduced wear rates have been reported for unidirectional, compared to multidirectional, articulation in vitro. This work for the first time enables investigation of a relationship between clinical wear conditions, as determined by patient gait path, and the mechanical and structural changes that occur within the UHMWPE acetabular component. Individual patients' wear paths were determined prior to revision operation from hip joint kinematics measured by clinical gait analysis. The material properties of the acetabular components removed during the revision operation were subsequently analysed. A technique using Fourier transform infra- red analysis (FTIR) was developed to quantify the orientation of the individual UHMWPE lamellae. This study shows that there is a direct relationship between a patient's clinical gait path and the molecular properties of their UHMWPE acetabular socket. Patient kinematics are an important factor affecting the wear and long-term biocompatibility of UHMWPE used as a bearing surface in THR.


Assuntos
Materiais Biocompatíveis/química , Análise de Falha de Equipamento/métodos , Marcha , Prótese de Quadril , Teste de Materiais/métodos , Polietilenos/química , Suporte de Carga , Idoso , Idoso de 80 Anos ou mais , Materiais Biocompatíveis/análise , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxirredução , Polietilenos/análise , Falha de Prótese , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA