1.
J Prosthodont ; 2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37439403

RESUMO

PURPOSE: To evaluate and compare the initial retention force of three resilient unsplinted attachment systems for implant-retained mandibular overdentures: two cylindrical attachment systems (Locator R-Tx® and Novaloc®), and one ball attachment system (Ball System). MATERIALS AND METHODS: For each attachment system, initial retention is measured as the average of the maximal dislodging forces during 10 insertion-removal cycles. For the Ball System, three activation degrees of the matrix are included versus four and six color-coded retention devices for the Locator R-Tx® and the Novaloc®, respectively, to represent the complete regular retention devices panel. For each retention device or activation degree, eight samples are tested. RESULTS: The initial retention range is similar between the Ball System (7.7 ± 3.4 N - 19.9 ± 4.6 N) and the Novaloc® (2.0 ± 0.5 N - 18.9 ± 1.4 N) and broader for the Locator R-Tx® (3.3 ± 5.0 N - 60.2 ± 6.0 N). In each attachment system, the initial retention of each retention device is significantly different from the others, except for the two most retentive Novaloc® ones. Retention devices were also classified according to their initial retention (low, medium, and maximum). In each retention group, the Novaloc® and the Ball System provided similar retention values lower than the Locator R-Tx®. CONCLUSION: Most of the retention devices tested provided an initial retention force of over 5 N for all three attachment systems. The Locator R-Tx® had the most comprehensive range, and the Novaloc® seemed to provide the most reproducible values, unlike the Ball System due to the activation required by the operator.

2.
J Prosthodont ; 31(1): 50-58, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33569866

RESUMO

PURPOSE: To mechanically characterize and assess the biological properties of Ti6Al4V surfaces obtained by Selective Laser Melting in order to determine whether this process is conceivable for production of implant-supported prostheses and particularly trans-gingival components. As-built and polished surfaces were studied in comparison with components obtained by computer numerical control machining technology in order to consider whether the properties are in the same range as the conventional method currently used. MATERIALS AND METHODS: Cylindrical specimens of Ti6Al4V (n = 6) were built with Selective Laser Melting for the characterization of mechanical properties according to ISO 22674 and discs (n = 12) were fabricated in the same conditions for cytotoxicity evaluation. Discs (n = 12) of Ti6Al4V were also obtained by computer numerical control machining as control. Half of the number of discs (n = 6) from each process were polished, to simulate the laboratory protocol for polishing of transmucosal components and half of the discs remained unaltered (as-built). Surface roughness measurements of disc specimens (as-built and polished) were compared with computer numerical control milling specimens (as-built and polished). Proliferation of human gingival fibroblasts on Ti6Al4V surfaces was also assessed for each condition. Viability and cell morphology were then evaluated qualitatively. Ra and Sa data were compared using Student's t-test (α = 0.05) and metabolic activity data were compared using Kruskal-Wallis statistical test (α = 0.05). RESULTS: Selective Laser Melting specimens showed elongation at break greater than 2% and 0.2% yield strength better than 500MPa which complied with ISO 22674 standards. Although Selective Laser Melting samples displayed significantly increased roughness on as-built surfaces compared to computer numerically controlled milling samples (p < 0.05), no statistically significant difference was observed after mechanical polishing (p = 0.279). Regarding metabolic activity, no statistical difference was observed between groups at day 3 (p > 0.05) and fibroblasts showed a viability higher than 97% on all discs. Cell shapes on polished samples suggested moderate adhesion compared to unpolished samples. CONCLUSION: With the manufacturing parameters selected in this study, Selective Laser Melting of Ti6Al4V appeared to be compatible with a prosthetic application type 4 according to ISO 22674. Surfaces obtained, followed by recommended postprocessing provided components with equivalent biological properties compared to computer numerical control machining technology.


Assuntos
Implantes Dentários , Titânio , Ligas , Fibroblastos , Humanos , Lasers , Teste de Materiais , Propriedades de Superfície
3.
J Mech Behav Biomed Mater ; 150: 106269, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38043259

RESUMO

BACKGROUND: The stud-shaped attachment systems (AS) with different shape designs (ball, cylindrical, conical) and materials (metallic, plastic, or a combination of both) are commonly used to provide better retention and stability in implant-retained mandibular overdentures (IRMO). PURPOSE: The purpose of the present study was to evaluate and compare the retention loss and the wear (patterns, location, material loss) of three resilient unsplinted AS: a well-established ball attachment system (BAS) and two more recent cylindrical attachment systems (CAS), Locator R-Tx® and Novaloc®. MATERIALS AND METHODS: The implants, their corresponding abutments, the color-coded or position-coded retention devices (RD), the matrix metal housing were incorporated within CAD/CAM resin blocks and cyclically loaded with 19.6 N along the implant axis in a chewing machine to simulate 10,000 insertion-removal cycles (IRC). At cycle 10, 100, 1,000, 5,000, and 10,000, the retention force was measured using a universal testing machine. The wear was qualitatively examined using a binocular magnifier for both systems, and quantitatively assessed from micro-computed tomography acquisitions for CAS. Material loss exceeding 50 µm was considered significant. RESULTS: The three AS showed different retentive behavior along time. All the Locator R-Tx® RD lost more than 50 % of their retention after 10,000 IRC. The retention of the Ball System slightly varied over time, the final retention loss in Bmed and Bmax groups being lower than 25 % of the initial retention. Wear was located at the tip of their gold RD and at the equator area of their ball abutment. For Locator R-Tx®, the more retentive the plastic RD, the greater its wear and retention loss. Only Novaloc® maintained a stable retention with even a slight tendency to increase and showed a negligible wear. Implant abutments of the CAS showed no significant wear. CONCLUSION: After 10,000 IRC, corresponding to approximately 5-years clinical use, almost all RD provided retention force over 5 N, which could be sufficient to maintain satisfaction in most of the patients. The retention loss observed most prominently for the Locator R-Tx®, then for the Ball System, seemed to correlate with the wear observed on their RD. The practitioner may expect less RD maintenance with the Novaloc® stable retention overtime.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Humanos , Retenção de Dentadura/métodos , Microtomografia por Raio-X , Mandíbula , Análise do Estresse Dentário
4.
J Mech Behav Biomed Mater ; 152: 106409, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38277910

RESUMO

The main cause of failure in bonded ceramic restorations is material fracture due to excessive stress concentration at the base of the prosthesis. The design of restorative functionally graded materials (FGM) could represent a major advance in dissipating mechanical stresses during occlusal contacts. The aim of this paper is to carry out a complete factorial design of finite element analyses to optimize a multilayer FGM introduced at the bottom of an overlay prosthesis. The number and thickness of layers vary within a spectrum compatible with ceramic shaping processes whereas Young's moduli variations are set in the range of dental tissues. For a 1.5-mm thick prosthesis, the optimal FGM configuration appears to be a 5 layers of 0.2 mm thickness with a linear distribution of Young's modulus from 30 to 70 GPa. This configuration was implemented in a 3D model of a restored tooth with realistic geometry to validate the proof-of-concept.


Assuntos
Cerâmica , Fraturas Ósseas , Humanos , Análise de Elementos Finitos , Módulo de Elasticidade , Estresse Mecânico
5.
Dent Mater ; 40(3): 520-526, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38212175

RESUMO

OBJECTIVE: The aim of this study was to evaluate the remineralizing properties of ion-releasing restorative materials on pH cycling-induced carious dentin. METHODS: Fifty sound molars were freshly extracted. The occlusal surfaces were abraded using water-cooled sandpaper (800 grit). The residual crowns were embedded in self-cured acrylic resin with the flat dentin surface exposed. A mesio-distal trench was created using a calibrated 0.5 mm deep occlusal reduction burr, and artificial dentin caries were generated by pH cycling. Then, teeth were randomly assigned to five groups according to the ion-releasing material used. For each sample, micro-CT acquisitions were performed at various intervals. Remineralization was assessed by mean gray value (MGV) measurements after registration and segmentation of the region of interest with 3D Slicer software. One-way repeated-measures ANOVA followed by Tukey's post hoc test was used to investigate the difference in MGVs among the various groups. RESULTS: Only Cention Forte showed significantly increased MGVs after 4 weeks compared to demineralized dentin. MGVs were higher, but not significantly, after placement of the restorative materials, including in the resin composite control group. These results can be explained by the radiopacity of the materials. SIGNIFICANCE: Cention Forte, the material with the highest radiopacity, showed a significant increase in the MGVs of artificially carious dentin after 4 weeks. However, the study of dentin remineralization by micro-CT could be impacted by the radiopacity of the restorative materials used. The relevance of this examination for the study of dentinal remineralization should be investigated.


Assuntos
Cárie Dentária , Cimentos de Ionômeros de Vidro , Humanos , Cimentos de Ionômeros de Vidro/química , Microtomografia por Raio-X , Materiais Dentários/química , Cárie Dentária/terapia , Resinas Compostas/química , Dentina/química , Teste de Materiais
6.
Materials (Basel) ; 15(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35269164

RESUMO

Attachment systems (AS) enhance retention and stability by anchoring the overdentures to implants. Since 2002, the McGill consensus statement recommends the 2-implant-retained overdentures as the standard choice for edentulous mandible (2-IRMO). Considering the large number of AS available, it remains difficult for a practitioner to make a reasoned choice. A systematic review was conducted in PubMed/Medline and carried out independently by three authors, on retention, wear, and maintenance of AS used clinically or in vitro specifically for 1- or 2-IRMO. The 45 selected studies include 14 clinical and 31 in vitro studies. The risk of bias was evaluated according to the revised Cochrane risk of bias tool for randomized trials (RoB 2). The initial retention force of the cylindrical system is higher than the ball system. The retention loss, related to the wear of the retention device, is responsible for the most common need of maintenance, requiring activation or replacement. Plastic retention devices wear out faster and more significantly than metal ones, implying a worse time behavior of cylindrical systems, but their maintenance rate is similar. Neither system appears categorically superior. Cylindrical systems provide higher initial retention than ball ones; this advantage reduces over time with wear without affecting their need for maintenance.

7.
Dent Mater J ; 41(1): 110-116, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34866117

RESUMO

Mechanical properties of polylactic acid (PLA), which is a biopolymer obtained via 3D-printing, were compared with conventional resins for the realization of interim prosthesis. A PLA built by fused deposition modeling and traditional interim resins (Unifast®, Integrity®, Temporary CB®) were divided into 4 groups (n=10). Each group was investigated for Young modulus, flexural strength, microhardness and analysis of the fractured surface. Data were analyzed by Kruskal-Wallis and ANOVA (α=0.05). The porosity of the PLA was calculated from the crystallinity degree and density. PLA-group showed an elastic modulus and flexural strength in the same range than Integrity®-group, better than Unifast®-group and inferior to Temporary CB®-group (p<0.05). PLA-group microhardness was equivalent to Unifast®-group and inferior to Integrity® and Temporary CB® groups (p<0.05). Due to mechanical properties similar to conventional resins and the low porosity rate, this biocompatible 3D-printed polymer may be an interesting alternative to conventional polymer to build temporary prosthesis.


Assuntos
Poliésteres , Polímeros , Porosidade , Impressão Tridimensional
8.
Int J Prosthodont ; 32(1): 104-106, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30677121

RESUMO

PURPOSE: To evaluate the influence of fabrication processes on the mechanical properties of denture base resins. MATERIALS AND METHODS: Flexural strength, fracture toughness, and Vickers hardness were measured on a conventional pack-and-press resin (PRO), a resin for injection molding (CAP), and a CAD/CAM disc (CAD). RESULTS: For maximal flexural strength, PRO (97.31 MPa) was stronger than CAD (87.98 MPa) and CAP (79.35 MPa). CAD displayed hardness similar to PRO and high fracture toughness. CONCLUSION: CAD/CAM denture base resin mechanical properties result from the evolution of denture base materials, combining high-impact fracture toughness and improved flexural strength and hardness.


Assuntos
Bases de Dentadura , Dureza , Teste de Materiais
9.
Int J Prosthodont ; 31(6): 591-593, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30408142

RESUMO

PURPOSE: To determine whether selective laser melting (SLM) is suitable for the fabrication of dental superstructures. MATERIALS AND METHODS: Mechanical properties of Ti-6Al-4V, manufactured with SLM or numerically controlled milling, were evaluated and compared. RESULTS AND CONCLUSION: Both groups showed a mechanical strength greater than 500 MPa and an elongation greater than 2%, as required by the International Organization for Standardization 22674 standard. However, a reduced ductility was observed for SLM samples.


Assuntos
Alumínio/química , Desenho Assistido por Computador , Ligas Dentárias/química , Planejamento de Prótese Dentária , Lasers , Titânio/química , Módulo de Elasticidade , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Resistência à Tração