RESUMO
Graphene coating on the cobalt-chromium alloy was optimized and successfully carried out by a cold-wall chemical vapor deposition (CW-CVD) method. A uniform layer of graphene for a large area of the Co-Cr alloy (discs of 10 mm diameter) was confirmed by Raman mapping coated area and analyzing specific G and 2D bands; in particular, the intensity ratio and the number of layers were calculated. The effect of the CW-CVD process on the microstructure and the morphology of the Co-Cr surface was investigated by scanning X-ray photoelectron microscope (SPEM), atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Nanoindentation and scratch tests were performed to determine mechanical properties of Co-Cr disks. The results of microbiological tests indicate that the studied Co-Cr alloys covered with a graphene layer did not show a pro-coagulant effect. The obtained results confirm the possibility of using the developed coating method in medical applications, in particular in the field of cardiovascular diseases.
Assuntos
Ligas de Cromo/química , Materiais Revestidos Biocompatíveis/química , Grafite/química , Animais , Fatores de Coagulação Sanguínea/metabolismo , Plaquetas/citologia , Plaquetas/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Ligas de Cromo/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Eritrócitos/efeitos dos fármacos , Humanos , Teste de Materiais/métodos , Camundongos , Células NIH 3T3 , Tempo de Tromboplastina Parcial , Ativação Plaquetária/efeitos dos fármacos , Cultura Primária de Células , Propriedades de Superfície , VolatilizaçãoRESUMO
BACKGROUND: Liposomes serve as delivery systems for biologically active compounds. Existing technologies inefficiently encapsulate large hydrophilic macromolecules, such as PVP-conjugated chlorin e6 (Photolon). This photoactive drug has been widely tested for therapeutic applications, including photodynamic reduction of atherosclerotic plaque. METHODS: A novel formulation of Photolon was produced using "gel hydration technology". Its pharmacokinetics was tested in Sus scrofa f. domestica. Its cellular uptake, cytotoxicity, and ability to induce a phototoxic reaction were demonstrated in J774A.1, RAW264.7 macrophages, and vascular smooth muscle (T/G HA-VSMC) as well as in vascular endothelial (HUVEC) cells. RESULTS: Developed liposomes had an average diameter of 124.7 ± 0.6 nm (polydispersity index (PDI) = 0.055) and contained >80% of Photolon). The half-life of formulation in S. scrofa was 20 min with area under the curve (AUC) equal to 14.7. The formulation was noncytotoxic in vitro and was rapidly (10 min) and efficiently accumulated by macrophages, but not T/G HA-VSMC or HUVEC. The accumulated quantity of photosensitizer was sufficient for induction of phototoxicity in J774A.1, but not in T/G HA-VSMC. CONCLUSIONS: Due to the excellent physical and pharmacokinetic properties and selectivity for macrophages, the novel liposomal formulation of Photolon is a promising therapeutic candidate for use in arteriosclerosis treatment when targeting macrophages but not accompanying vascular tissue is critical for effective and safe therapy.
Assuntos
Lipossomos , Fotoquimioterapia , Fármacos Fotossensibilizantes/química , Fármacos Fotossensibilizantes/farmacologia , Porfirinas/química , Porfirinas/farmacologia , Animais , Linhagem Celular , Clorofilídeos , Composição de Medicamentos , Humanos , Lipossomos/química , Lipossomos/ultraestrutura , Macrófagos/efeitos dos fármacos , Macrófagos/metabolismo , Macrófagos/patologia , Camundongos , Fotoquimioterapia/métodos , Placa Aterosclerótica/etiologia , Placa Aterosclerótica/metabolismo , Placa Aterosclerótica/patologia , Placa Aterosclerótica/terapia , Espécies Reativas de OxigênioRESUMO
Rapid endothelialization of cardiovascular stents is critical to prevent major clinical complications such as restenosis. Reconstruction of the native endothelium on the stent surface can be achieved by the capture of endothelial progenitor cells (EPCs) or neighboring endothelial cells (ECs) in vivo. In this study, stainless steel cardiovascular stents were functionalized with recombinant scFv antibody fragments specific for vascular endothelial growth factor receptor-2 (VEGFR2) that is expressed on EPCs and ECs. Anti-VEGFR2 scFvs were expressed in glycosylated form in Escherichia coli and covalently attached to amine-functionalized, titania-coated steel disks and stents. ScFv-coated surfaces exhibited no detectable cytotoxicity to human ECs or erythrocytes in vitro and bound 15 times more VEGFR2-positive human umbilical vein ECs than controls after as little as 3 min. Porcine coronary arteries were successfully stented with scFv-coated stents with no adverse clinical events after 30 days. Endovascular imaging and histology revealed coverage of the anti-VEGFR2 scFv-coated stent with a cell layer after 5 days and the presence of a neointima layer with a minimum thickness of 80 µm after 30 days. Biofunctionalization of cardiovascular stents with endothelial cell-capturing antibody fragments in this manner offers promise in accelerating stent endothelialization in vivo. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 108B:213-224, 2020.
Assuntos
Materiais Revestidos Biocompatíveis/farmacologia , Células Endoteliais da Veia Umbilical Humana/metabolismo , Anticorpos de Cadeia Única/farmacologia , Stents , Receptor 2 de Fatores de Crescimento do Endotélio Vascular , Animais , Linhagem Celular Transformada , Materiais Revestidos Biocompatíveis/química , Humanos , Anticorpos de Cadeia Única/química , Sus scrofaRESUMO
We report a multistep strategy of biochemical surface modifications that resulted in the synthesis of new, effective and biocompatible intravascular implants coating with immobilized anti-CD133 antibodies, that proved to be the most effective in endothelial progenitor cells capture and reduced smooth muscle cells growth. Biomolecules were immobilized on differently functionalized surfaces. The distribution, nanostructural characteristics and intramolecular interactions of anti-CD133 molecules as well as their ability to bind EPCs was evaluated. We also tempted to build a molecular model of the CD133 protein to study antigen-antibody interactions. CD133 protein is expressed in endothelial progenitor cells (EPCs). Absence of preferential interaction site on CD133, but rather a presence of a small binding area, may be the specificity of reconnaissance sequence, thus importantly increasing the probability of CD133 protein binding. After all, regarding our molecular model, we are convinced that specific, and large enough interactions between anti-CD133 coating stent surface and CD133 present on EPCs will reduce risk of restenosis by favoring the endothelial growth. Additionally, the safety study of the vivo performance of modified titania based surface was performed using small animal models. No allergological or toxical local or systemic adverse effects of the developed coatings were noted.
Assuntos
Antígeno AC133/imunologia , Anticorpos Imobilizados/imunologia , Adesão Celular , Proliferação de Células , Células Progenitoras Endoteliais/fisiologia , Miócitos de Músculo Liso/citologia , Stents , Animais , Anticorpos Imobilizados/química , Anticorpos Monoclonais/imunologia , Células Cultivadas , Materiais Revestidos Biocompatíveis/química , Reestenose Coronária/prevenção & controle , Células Progenitoras Endoteliais/citologia , Feminino , Cobaias , Humanos , Masculino , Ratos , Ratos WistarRESUMO
Stainless steel 316L is a material commonly used in cardiovascular medicine. Despite the various methods applied in stent production, the rates of in-stent restenosis and thrombosis remain high. In this study graphene was used to coat the surface of 316L substrate for enhanced bio- and hemocompatibility of the substrate. The presence of graphene layers applied to the substrate was investigated using cutting-edge imaging technology: energy-filtered low-voltage FE-SEM approach, scanning electron microscopy (SEM), Raman spectroscopy, and atomic force microscopy (AFM). The potential of G-316L surface to influence endothelial cells phenotype and endothelial-to-mesenchymal transition (EndoMT) has been determined. Our results show that the bio- and hemocompatible properties of graphene coatings along with known radial force of 316L make G-316L a promising candidate for intracoronary implants.