Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(10): 536, 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39302523

RESUMO

OBJECTIVE: To investigate the efficacy of ribose-crosslinked collagen (RCLC) matrices functionalized by crosslinked hyaluronic acid (xHya) for reconstructive treatment of class I and III (b-c) peri-implantitis lesions in a transmucosal healing mode. MATERIALS AND METHODS: Thirteen patients presenting with 15 implants were included in this prospective case series. Upon flap reflection, the implants were thoroughly decontaminated employing glycine powder air polishing and adjunctive sodium hypochlorite. For defect augmentation, xHyA was administered to the bony defect walls, exposed implant surfaces, and the RCLC matrix before defect grafting. The full-thickness flap was readapted and sutured around the implant neck for transmucosal healing. Baseline and respective values at the 12 months post-op evaluation were recorded for the clinical parameters peri-implant probing depth (PPD), buccal soft tissue dehiscence (BSTD) and bleeding on probing (BoP). Furthermore, two independent investigators analyzed radiographic changes in the defect area. The mean changes for all variables were analyzed with a paired t-test. RESULTS: The initial mean PPD was 7.2 ± 1.9 mm, and BoP was present in 63% of sites. After 12 months, PPD at the latest visit was 3.2 ± 0.66 mm, which amounted to a respective 3.9 ± 1.85 mm reduction, while the BoP frequency dropped to 10% at all sites. Radiographic bone fill was accomplished for 62.8% of the former defect area, accompanied by a mean MBL gain of 1.02 mm around the treated implants (all p < 0.001). CONCLUSIONS: Within the limits of this case series, we conclude that the proposed treatment sequence substantially improved peri-implant defects and offered a simplified but predictive technique. CLINICAL RELEVANCE: Reconstructive treatment approaches for peri-implantitis are effective but remain non-superior to open flap debridement. Further research on novel biomaterial combinations that may improve reconstructive treatment outcomes are warranted. Ribose-crosslinked collagen matrices biofunctionalized by hyaluronic acid used in this study yield improved clinical and radiographic peri-implant conditions after 12 months.


Assuntos
Colágeno , Ácido Hialurônico , Peri-Implantite , Ribose , Humanos , Estudos Prospectivos , Ácido Hialurônico/química , Masculino , Feminino , Pessoa de Meia-Idade , Ribose/química , Peri-Implantite/cirurgia , Resultado do Tratamento , Retalhos Cirúrgicos , Adulto , Reagentes de Ligações Cruzadas/química , Idoso , Procedimentos de Cirurgia Plástica/métodos , Cicatrização , Implantes Dentários
2.
Clin Oral Investig ; 27(3): 1167-1175, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36229741

RESUMO

OBJECTIVES: The aim of this study was to assess the microcirculation and the expression patterns of wound-healing-related cytokines around narrow-diameter implants in type 2 diabetes mellitus (T2DM) and normo-glycemic patients. MATERIALS AND METHODS: A total of 31 patients, 16 of which diagnosed with T2DM (HbA1c > 6.5) and 15 normo-glycemic patients, received narrow diameter implants in the posterior mandible or maxilla. During the 3-month healing period, soft-tissue perfusion was monitored via laser Doppler flowmetry. Peri-implant fluid (PICF) was harvested and analyzed for concentrations of interleukin-1ß (IL-1ß), interleukin-23 (IL-23), interleukin-17 (IL-17), and granulocyte colony-stimulating factor (G-CSF) by a multiplex, bead-based immunoassay. RESULTS: Microcirculatory perfusion patterns during wound healing exhibited no significant differences throughout the observation period. IL-1ß concentrations were expectedly elevated during the early phases of wound healing. At the first visit after surgery, IL-23 concentrations were significantly higher in implants of diabetic patients. This difference was diminished over the course of the observation period. For the other tested analytes, no differences were observable between both groups. CONCLUSION: Wound healing after implant surgery was similar in T2DM and healthy patients. Hydrophilic-surface titanium-zirconium implants with reduced diameter may be considered for implant therapy of diabetes mellitus type II patients. REGISTRATION NUMBER: NCT04630691 (clinicaltrials.gov).


Assuntos
Implantes Dentários , Diabetes Mellitus Tipo 2 , Humanos , Citocinas/metabolismo , Microcirculação , Neutrófilos/química , Neutrófilos/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Líquido do Sulco Gengival/química , Cicatrização
3.
J Prosthet Dent ; 130(6): 885-888, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35181057

RESUMO

STATEMENT OF PROBLEM: The optimal positioning of artificial teeth is essential for long-term success when providing removable complete dentures. However, information about the original tooth positions may be lacking, especially the canine teeth, which play a key role in the tooth arrangement. PURPOSE: The purpose of this pilot clinical study was to determine if the mandibular and maxillary canine position can be determined by proportioning to certain anatomic landmarks. MATERIAL AND METHODS: Fifty participants (32 women, 18 men) with a mean age of 19.18 years and Angle class 1 and 2 malocclusions were selected randomly from patients who had completed their orthodontic treatment. The distance between the sagittally bisecting lines of the maxillary tuberosity and the distance between the sagittal bisecting lines of the retromolar pads in the mandible were measured from casts and recorded in millimeters. The expected distances between the canine cusps in both jaws (e-DCCmand and e-DCCmax) were calculated, and the distance between the canine cusps in both jaws (DCCmand and DCCmax) was measured. The measurements and the calculated expectation values for maxillary and mandibular cast models were recorded and statistically compared. RESULTS: The mean ±standard deviation value of the maxillary intercanine distance was 35.5 ±1.4 mm, and the calculated value was 35.52 ±1.43 mm. In the mandible, the mean ±standard deviation value of the mandibular intercanine distance was 26.73 ±1.25 mm, and the calculated value was 26.69 ±1.33 mm. The difference between the means of expected DDC for the maxilla and mandible was within the equivalence interval (P<.001). CONCLUSIONS: The proportions evaluated were determined to provide accurate canine positions and should be suitable for use in the treatment of edentulous patients.


Assuntos
Prótese Total , Mandíbula , Masculino , Humanos , Feminino , Adulto Jovem , Adulto , Maxila , Dente Canino
4.
Clin Oral Investig ; 25(12): 6707-6715, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33939006

RESUMO

OBJECTIVES: The aim of the study was to compare the performance of narrow diameter implants in patients with uncontrolled diabetes mellitus type 2 (T2DM) and normo-glycemic individuals during the first 12 months after implant loading. MATERIAL AND METHODS: In 16 T2DM patients with HbA1C > 6.5% (test group) and 16 normo-glycemic patients (HbA1C < 6.0%; control group), one to two narrow diameter tissue level implants were placed in the posterior maxilla or mandible. After 3-month lasting integration period, implants were loaded by fixed dentures. The clinical parameters probing depth (PD), bleeding on probing (BOP), attachment loss (CAL), recession and papilla bleeding index (PBI) were assessed manually at loading and after 12 months of function. The paired digital periapical radiographs were analyzed with regard to the change in marginal bone level (MBL) from baseline to 12 months' control. The mean values calculated for both patient groups were statistically analyzed. The technical complications were recorded. RESULTS: The T2DM group accounted 13 patients due to 3 dropouts. The overall implant survival rate after 12 months was 100%. The differences in means for the clinical parameters and the MBL were statistically non-significant between the T2DM and normo-glycemic patients for the short period of loaded function reported here. No technical complications were recorded. CONCLUSIONS: The study demonstrated an encouraging clinical outcome with narrow diameter implants in patients with uncontrolled T2DM compared to non-diabetics after 12 months post loading. For the short observation period, no biological and technical complications were reported regardless the glycemic status. CLINICAL RELEVANCE: Patients with HbA1C > 6.5% may benefit from the treatment with narrow diameter implants by avoiding complex surgical interventions with augmentation procedures. TRIAL REGISTRATION: Clinicaltrials.gov : NCT04630691.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Glicemia , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Seguimentos , Humanos , Mandíbula , Maxila , Projetos Piloto , Resultado do Tratamento
5.
J Prosthet Dent ; 124(6): 755-760, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31987587

RESUMO

STATEMENT OF PROBLEM: Digital scanning systems have become popular, but whether these systems are adequate for complete-arch implant-supported fixed dental prostheses is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the trueness of 10 different dental intraoral scanners. MATERIAL AND METHODS: Six implant analogs were installed, and an edentulous mandibular model composed of scannable Type 4 gypsum was scanned with 10 different intraoral scanners (3D Progress, Omnicam, Bluecam, Apollo DI, Planscan, E4D Tech, TRIOS MonoColor Cart, TRIOS Color Cart, TRIOS Color Pod, Lythos), 10 times each after the scan body was placed on the implant abutments. The data obtained were then converted into standard tessellation language format. For the control group, the gypsum model was scanned with an industrial scanner (ATOS Core 80). For trueness, the dental and industrial scanning data packs were analyzed with 3D comparison software. Statistical analyses were performed by using the Kruskal-Wallis and Mann-Whitney U tests. RESULTS: When ranked according to their surface superimposition values, the Color POD, Omnicam, Apollo DI, Color Cart, MonoColor Cart, and Bluecam scanners were found within the range of 31 to 45 µm. This group was followed by E4D, 3D Progress, Lythos, and Planscan, which were found within the range of 82 to 344 µm according to the same criteria. CONCLUSIONS: Some of the digital scanners had the necessary performance for the fabrication of complete-arch implant-supported fixed dental prostheses. However, the possibility of data loss producing artifacts should be considered.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Arco Dental/diagnóstico por imagem , Imageamento Tridimensional , Modelos Dentários
6.
Implant Dent ; 26(1): 87-94, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28079610

RESUMO

OBJECTIVES: The aim of this study was to determine the influence of different frontal bone defect localizations on primary stability values of 2 different implant designs. MATERIALS AND METHODS: Eight cow rib segments were prepared before implant installation, as 2 segments with coronal, 2 with middle, and 2 with apical defects and 2 with control. Thirty-two cylindrical and 32 tapered implants were placed in the remaining 4 segments. Implant stability measurements were performed using electronic percussive testing and resonance frequency analysis. RESULTS: No significance was detected between the stability values of the 2 implant designs except the implant stability quotient (ISQ) of control groups. The tapered implants control group showed significantly higher lateral ISQs compared with cylindrical implants (P = 0.033). For both implant types, stability values were significantly lower in coronal defects (P < 0.01). No significant differences were detected in other defect types. CONCLUSION: Within the limitations of this study, it may be concluded that coronal defects may influence primary stability negatively, compared with middle and apical defects. Although statistically not significant, coronal defects caused lower primary stability values with the tapered design compared with parallel design.


Assuntos
Interface Osso-Implante/patologia , Implantes Dentários , Planejamento de Prótese Dentária , Osso Frontal/cirurgia , Animais , Bovinos , Planejamento de Prótese Dentária/métodos , Retenção em Prótese Dentária , Análise do Estresse Dentário/métodos , Osso Frontal/patologia , Técnicas In Vitro , Costelas/cirurgia
7.
Implant Dent ; 23(1): 44-50, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24113554

RESUMO

PURPOSE: To analyze the prognostic factors that are associated with the success, survival, and failure rates of dental implants. MATERIAL AND METHODS: Data including implant sizes, insertion time, implant location, and prosthetic treatment of 1656 implants have been collected, and the association of these factors with success, survival, and failure of implants was analyzed. RESULTS: The success rate was lower for short and maxillary implants. The failure rate of maxillary implants exceeded that of mandibular implants, and the failure rate of implants that were placed in the maxillary anterior region was significantly higher than other regions. The failure rates of implants that were placed 5 years ago or more were higher than those that were placed later. CONCLUSIONS: Anterior maxilla is more critical for implant loss than other sites. Implants in the anterior mandible show better success compared with other locations, and longer implants show better success rates. The learning curve of the clinician influences survival and success rates of dental implants.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária/estatística & dados numéricos , Falha de Restauração Dentária/estatística & dados numéricos , Implantação Dentária/efeitos adversos , Implantação Dentária/métodos , Implantação Dentária/estatística & dados numéricos , Implantes Dentários/efeitos adversos , Implantes Dentários/normas , Implantes Dentários/estatística & dados numéricos , Feminino , Humanos , Masculino , Mandíbula , Maxila , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco
8.
Int J Biomater ; 2024: 7322223, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38966862

RESUMO

It is well known that soft tissue quality and quantity around dental implants is of paramount importance for later peri-implant health. For this purpose, the clinical and histological outcomes of the peri-implant mucosa, following soft tissue augmentation for soft tissue improvement with a novel prehydrated porcine acellular dermal matrix graft (PPADMG) in conjunction with simultaneous implant placement, were evaluated in this case series. Twenty-two patients were included in the study. They underwent a late implant placement protocol combined with PPADMG for soft tissue augmentation. A punch biopsy was taken at the time of uncovery of the submerged healed implant after a mean of 157 days healing time. Supracrestal soft tissue height (STH) was measured at the time of implant placement and uncovery. All sites showed a clinical increase in STH. The histological structure of the biopsies resembled a similar structure as found in the healthy oral mucosa. No unexpected tissue reactions could be found. Within the limits of this clinical and histological study, it may be concluded that STH improvement with this novel porcine-derived acellular dermal matrix, in combination with simultaneous implant placement, is a viable option to create a peri-implant tissue thickness and stability.

9.
Bioengineering (Basel) ; 11(7)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-39061747

RESUMO

In recent years, the significance of maintaining the alveolar ridge following tooth extractions has markedly increased. Alveolar ridge preservation (ARP) is a commonly utilized technique and a variety of bone substitute materials and biologics are applied in different combinations. For this purpose, a histological evaluation and the clinical necessity of subsequent guided bone regeneration (GBR) in delayed implantations were investigated in a prospective case series after ARP with a novel deproteinized bovine bone material (95%) in combination with a species-specific collagen (5%) (C-DBBM). Notably, block-form bone substitutes without porcine collagen are limited, and moreover, the availability of histological data on this material remains limited. Ten patients, each scheduled for tooth extraction and desiring future implantation, were included in this study. Following tooth extraction, ARP was performed using a block form of C-DBBM in conjunction with a double-folded bovine cross-linked collagen membrane (xCM). This membrane was openly exposed to the oral cavity and secured using a crisscross suture. After a healing period ranging from 130 to 319 days, guided trephine drilling was performed for implant insertion utilizing static computer-aided implant surgery (s-CAIS). Cores harvested from the area previously treated with ARP were histologically processed and examined. Guided bone regeneration (GBR) was not necessary for any of the implantations. Histological examination revealed the development of a lattice of cancellous bone trabeculae through appositional membranous osteogenesis at various stages surrounding C-DBBM granules as well as larger spongy or compact ossicles with minimal remnants. The clinical follow-up period ranged from 2.5 to 4.5 years, during which no biological or technical complications occurred. Within the limitations of this prospective case series, it can be concluded that ARP using this novel C-DBBM in combination with a bovine xCM could be a treatment option to avoid the need for subsequent GBR in delayed implantations with the opportunity of a bovine species-specific biomaterial chain.

10.
Implant Dent ; 22(1): 39-48, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23296030

RESUMO

OBJECTIVES: The main goal of this study was to compare the stress distribution of mandibular overdentures (OVD) with different numbers of supporting implants and single versus splinted attachment types. MATERIALS AND METHODS: Four different biting situations were simulated for the 2-, 3-, and 4-implant retentive anchor as well as bar attachment OVDs on a formalin-fixed cadaver mandible, and strains were recorded under vertical loading of 100 N. RESULTS: The calculated von Mises values from measured strains in all measurement sites and loading conditions for nonsplinted attachments (retentive anchor) were higher than splinted (bar) attachments. CONCLUSIONS: It may be concluded that in cases with low quality and quantity of bone, the increase in number of implants and the use of a splinted attachment should be preferred to reduce forces emerging around the implants during function. The use of 2 single attachments in cases with good bone quality and ideal size implants still seems to be a safe and sufficient solution for the treatment of mandibular edentulism with OVDs.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Planejamento de Dentadura , Retenção de Dentadura , Prótese Total Inferior , Revestimento de Dentadura , Mandíbula/fisiologia , Fenômenos Biomecânicos , Força de Mordida , Densidade Óssea/fisiologia , Cadáver , Oclusão Dentária Central , Retenção de Dentadura/instrumentação , Humanos , Arcada Edêntula/fisiopatologia , Mastigação/fisiologia , Estresse Mecânico
11.
J Oral Implantol ; 39(1): 115-20, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20932120

RESUMO

The prosthetic treatment of patients with an edentulous maxilla opposing mandibular natural teeth is one of the most challenging endeavors that face clinicians. Occlusal forces from the opposing natural teeth may cause fractures in the maxillary prosthesis and also result in advanced bone loss of the edentulous maxilla. With the presence of extreme gagging reflex, the treatment may become more complicated. This article describes and illustrates the 2-stage surgical and prosthetic treatment of a patient with an edentulous maxilla opposing natural teeth. In the beginning, the patient was treated with 4 implants and a maxillary implant-supported overdenture. The extreme gagging reflex and the occlusal forces from the mandibular natural teeth obligated the team a second stage surgical and prosthetic treatment, which included increasing the number of implants after bilateral sinus lifting in the posterior maxilla and fabricating a maxillary fixed hybrid prosthesis made of micro-ceramic composite that yielded a satisfactory result.


Assuntos
Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Prótese Total Superior , Arcada Edêntula/reabilitação , Levantamento do Assoalho do Seio Maxilar , Implantes Dentários , Porcelana Dentária , Falha de Restauração Dentária , Engasgo , Humanos , Arcada Edêntula/cirurgia , Masculino , Maxila/cirurgia , Pessoa de Meia-Idade , Reoperação
12.
J Prosthodont ; 22(3): 174-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22984815

RESUMO

PURPOSE: To compare the frequency of denture stomatitis (DS) under maxillary complete dentures (CDs) in patients with opposing mandibular distal extension removable partial dentures (RPDs) and CDs. MATERIALS AND METHODS: Participants included 365 maxillary CD wearers (241 women, mean age 70.5 ± 13.2 years; 124 men, mean age 71.5 ± 10.4 years) from 7 rest homes in Istanbul. A total of 268 had mandibular CDs; 97 had mandibular distal extension RPDs. Two independent, calibrated examiners performed oral examinations. Presence of maxillary denture-related stomatitis and the effect of risk factors on DS were evaluated and recorded. RESULTS: The frequency of palatal DS (Newton I-III) was 45.1% (n = 121) in the mandibular CD group and 49.5% (n = 48) in the mandibular distal extension RPD group, a statistically insignificant difference (p= 0.4). Factors significantly associated with palatal DS were maxillary denture age (p= 0.02), reduced occlusal vertical dimension (p= 0.04), and nocturnal denture wear (p= 0.03). CONCLUSION: In this study, DS beneath maxillary CDs did not differ between mandibular distal extension RPD and CD wearers. The presence of mandibular anterior teeth did not influence the occurrence of palatal DS.


Assuntos
Dentição , Prótese Total Superior , Palato Duro/patologia , Estomatite sob Prótese , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Prótese Total Superior/efeitos adversos , Prótese Parcial Removível/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Mandíbula , Fatores Sexuais , Fumar , Estomatite sob Prótese/epidemiologia , Estomatite sob Prótese/etiologia , Turquia
13.
N Y State Dent J ; 79(4): 38-43, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24027897

RESUMO

Titanium and its alloys have been widely used for dental prosthetic devices because of their superior mechanical properties and biocompatibility. However, the incidence of titanium hypersensitivity or allergy is still unknown and the discussion about its existence is ongoing. Unexplained implant failures have also forced dental clinicians to investigate the possibility of titanium hypersensitivity or allergy. This review focuses on the potential of dental implant-related titanium hypersensitivity or allergic reactions. It includes an examination of the existing scientific literature and current knowledge. Evidence-based data and studies related to titanium hypersensitivity in dental implant patients are also discussed.


Assuntos
Implantes Dentários/efeitos adversos , Materiais Dentários/efeitos adversos , Hipersensibilidade/etiologia , Titânio/efeitos adversos , Materiais Biocompatíveis/efeitos adversos , Ligas Dentárias/efeitos adversos , Falha de Restauração Dentária , Humanos , Hipersensibilidade/imunologia , Titânio/imunologia
14.
Int J Periodontics Restorative Dent ; (7): s53-s64, 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37294593

RESUMO

Tooth loss or extraction is associated with significant reduction in alveolar ridge volume, extensively expressed in the anterior zone, and immediate implant placement is insufficient to overcome this problem. The proposed approach combined immediate implant placement with buccal tissue enhancement by applying a crosslinked collagen matrix hydrated with crosslinked hyaluronic acid (xHyA). All 10 cases presented with a retained but narrow buccal socket wall, so immediate implant placement with the "tunneled sandwich" technique was performed after tooth extraction. The tunneled sandwich technique helped create a subperiosteal pouch for insertion of the collagen matrix buccal to the alveolar bone crest. The implants healed transmucosally by receiving either a gingiva former or an immediate temporary restoration. Ten sites in 10 patients demonstrated stable, noninflamed peri-implant conditions and suitable ridge volume at the implant neck and achieved high pink esthetic scores 6 months after implant loading. The tunneled sandwich technique is a suitable method to preserve buccal volume, which biologically and esthetically contributes to favorable long-term results.


Assuntos
Perda do Osso Alveolar , Implantes Dentários para Um Único Dente , Carga Imediata em Implante Dentário , Humanos , Implantação Dentária Endóssea/métodos , Carga Imediata em Implante Dentário/métodos , Resultado do Tratamento , Estudos Retrospectivos , Alvéolo Dental/cirurgia , Extração Dentária/métodos , Colágeno , Estética Dentária
15.
Int J Oral Maxillofac Implants ; 38(5): 954-962, 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37847837

RESUMO

PURPOSE: Τo evaluate and compare the marginal bone loss (MBL), survival rates, and periodontal parameters of immediately loaded implants with either Dolder bar or Locator attachments placed in the interforaminal region of edentulous mandibles. MATERIALS AND METHODS: A total of included 19 patients with edentulous mandibles each received two implants in the interforaminal area of the symphysis. Randomly allocated Dolder bar or Locator attachments were then attached immediately, and both clips and a framework were fastened to the denture by the dental laboratory within 24 hours. RESULTS: A total of 28 subjects with 56 implants were treated in accordance with the immediate-loading study protocol. Of these, 9 patients were lost to follow-up; 1 patient reported a serious illness and 8 patients moved and couldn't be reached. The 19 subjects not lost to follow-up (11 women and 8 men; average age: 68 years) were included. Every patient received either two Locator abutments and were assigned to group A (7 patients; 36.8%) or two multiunit abutments and were assigned to group B (12 patients; 63.2%). No implant failure was detected for either group, and therefore the survival rate for both groups was 100% after 5 years. After 5 years without any symptoms, 2 implants from group A and 7 implants from group B showed > 2 mm of MBL, which makes the group A success rate 85.7% and the group B success rate 70.8%. Modified sulcular bleeding index (mSBI) did not differ significantly at any of the measurement intervals. However, the modified plaque index (mPI) of group B was significantly higher than group A at the 60-month follow-up. CONCLUSION: It can be concluded that either splinting or not splinting the immediately loaded interforaminal implants to retain mandibular overdentures (OVDs) does not affect marginal bone levels after 5 years and immediate loading of nonsplinted implants with Locator attachments can be safely preferred to retain mandibular OVDs.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Carga Imediata em Implante Dentário , Arcada Edêntula , Masculino , Humanos , Feminino , Idoso , Taxa de Sobrevida , Carga Imediata em Implante Dentário/métodos , Revestimento de Dentadura , Arcada Edêntula/cirurgia , Prótese Dentária Fixada por Implante , Mandíbula/cirurgia , Resultado do Tratamento , Retenção de Dentadura
16.
Gerodontology ; 29(2): e618-23, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21726276

RESUMO

OBJECTIVE: The aim of this study was to compare the quality of life and patient satisfaction outcomes of two attachment systems in mandibular overdentures with different numbers of supporting implants. MATERIALS AND METHODS: Sixty-two edentulous patients with either splinted or single attachments in mandibular implant overdentures with different numbers of supporting interforaminal implants were investigated for patient satisfaction and quality of life in this retrospective study. Comparisons between groups were perceived by the Mann-Whitney U test. Relations among the parameters were investigated by Spearman's rho correlation analysis. The results were evaluated statistically at a significance level of p < 0.05. RESULTS: No statistically significant association is found between visual analogue scales scores and attachment type as well as implant number (p > 0.05), whereas Oral Health Impact Profile (OHIP)-14 total scores for patients with 4-implant-supported bars were significantly lower than all the other attachment types (p < 0.05). Additionally, a negative (rate = 32.2%), statistically significant association between period of edentulism and total OHIP-14 scores was detected (p < 0.05). CONCLUSIONS: A mandibular implant-retained overdenture supported with four implants and bar attachments shows the highest 'quality of life' score and patient satisfaction is not influenced by the number of implants or attachment type.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante/psicologia , Retenção de Dentadura/instrumentação , Revestimento de Dentadura/psicologia , Satisfação do Paciente , Qualidade de Vida , Adaptação Fisiológica/fisiologia , Idoso , Idoso de 80 Anos ou mais , Dente Suporte , Implantes Dentários/psicologia , Oclusão Dentária , Bases de Dentadura , Planejamento de Dentadura , Reembasamento de Dentadura , Prótese Total Inferior/psicologia , Estética Dentária , Feminino , Seguimentos , Humanos , Arcada Edêntula/reabilitação , Masculino , Mastigação/fisiologia , Pessoa de Meia-Idade , Higiene Bucal , Medição da Dor , Estudos Retrospectivos , Fala/fisiologia , Resultado do Tratamento
17.
Gerodontology ; 29(2): e116-20, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20735488

RESUMO

AIM: Assessment of the influence of such factors as attachment type, number of implants, gender and age of patients on maximum bite force (MBF). MATERIAL AND METHODS: Sixty-two edentulous patients (32 females, 30 males; aged 64.03 ± 10.07 years, range 42-90 years) with mandibular implant overdentures with various attachment types were included in the study and their MBFs were recorded. The results were evaluated statistically at a significance level of p < 0.05. RESULTS: The MBF in male patients was found to be statistically significantly (p < 0.05) higher than in female patients. No statistically significant differences (p > 0.05) were found with respect to age groups, attachment types and number of implants supporting the mandibular overdentures. CONCLUSION: Within the limitations of this study, it is concluded that independent of the number applied, dental implants increase MBF in edentulous patients. While males show higher bite force, patient age and attachment type seem not to play an important role.


Assuntos
Força de Mordida , Implantes Dentários , Retenção de Dentadura , Prótese Total Inferior , Revestimento de Dentadura , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Prótese Dentária Fixada por Implante , Planejamento de Dentadura , Retenção de Dentadura/instrumentação , Feminino , Humanos , Arcada Edêntula/reabilitação , Masculino , Mandíbula , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Método Simples-Cego
18.
J Oral Implantol ; 38(3): 271-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21189081

RESUMO

The treatment of edentulism with traditional complete dentures can often induce impaired masticatory function due to limited retention and stability, especially in the lower jaw. Mandibular interforaminal implants have been widely used to stabilize the dentures, consequently improving masticatory performance in edentulous individuals. The aim of the present study was to document the influence of this improved masticatory function on patient satisfaction and quality of life of patients wearing mandibular implant-supported overdentures. Sixty-two patients treated with various types of implant-supported mandibular overdentures between 2004 and 2007 were included in this retrospective study. Maximum bite force (MBF) was measured bilaterally using a device with 2 strain gauges connected to a strain gauge measurement system. All the included patients were asked to fill out visual analog scale (VAS) forms based on general and chewing satisfaction and OHIP-14 forms. Results were analyzed by the Spearman rho test. No statistically significant correlation was found between MBF values and VAS general or VAS chewing satisfaction or Oral Health Impact Profile scores (P > .05). The results indicate that MBF is not associated with the satisfaction or quality of life of implant-supported mandibular overdenture wearers.


Assuntos
Força de Mordida , Prótese Dentária Fixada por Implante , Prótese Total Inferior , Revestimento de Dentadura , Satisfação do Paciente , Qualidade de Vida , Adulto , Idoso , Idoso de 80 Anos ou mais , Atitude Frente a Saúde , Implantes Dentários/psicologia , Prótese Dentária Fixada por Implante/psicologia , Retenção de Dentadura , Prótese Total Inferior/psicologia , Revestimento de Dentadura/psicologia , Feminino , Humanos , Masculino , Mastigação/fisiologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Transdutores
19.
J Oral Implantol ; 38(5): 569-74, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21126171

RESUMO

This pilot study assesses the accuracy of 2 bone-supported stereolithographic surgical templates with respect to placement of implants in originally planned positions, and it tests the precision of dental volumetric tomography planning. Two mandibles retrieved from formalin-fixed human cadavers were scanned by dental volumetric tomography for planning of the implant positions, leading to stereolithographic models and fabrication of surgical guides. The situation immediately following drilling and implant insertion by an experienced surgeon was scanned and the outcome compared with the initial planning. The 3-dimensional discrepancies were then analyzed and determined. The results show deviations of the placed implants from the original planning, especially in the vertical direction, making the seating of a prefabricated denture impossible. At present, the flapless surgery technique based on stereolithographic surgical templates appears unsafe; further improvement is required.


Assuntos
Implantação Dentária Endóssea/instrumentação , Imageamento Tridimensional/métodos , Mandíbula/cirurgia , Modelos Dentários , Cirurgia Assistida por Computador/métodos , Humanos , Arcada Edêntula/reabilitação , Mandíbula/diagnóstico por imagem , Modelos Anatômicos , Planejamento de Assistência ao Paciente , Projetos Piloto , Radiografia , Radioterapia de Intensidade Modulada , Reprodutibilidade dos Testes
20.
Clin Exp Dent Res ; 8(4): 969-975, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35578391

RESUMO

OBJECTIVES: The aim of this prospective case-control study was to compare the development of implant stability quotients of narrow diameter implants in patients with type 2 diabetes mellitus (T2DM) and healthy individuals within the first 3 months after implant insertion. METHODS: Sixteen patients with T2DM (HbA1C > 6.5%) as test group and 16 nondiabetic patients (HbA1C < 5.9%) as the control group were evaluated. All patients received narrow-diameter tissue level implants in an edentulous area posterior to the canine. The implant stability was measured by means of resonance frequency analysis after 3 days, 7 days, 4 weeks, and 3 months postplacement. Statistical analysis of intergroup differences and correlation to HbA1c values and treated jaw was performed in PRISM 8. RESULTS: The means for implant stability quotients showed a significant increase between Day 3 and 3-month assessment in both groups. No significant differences between study groups and no correlation of implant stability to HbA1c were found. CONCLUSION: The present study shows encouraging clinical outcomes for narrow-diameter implants inserted in the posterior zone in patients with uncontrolled T2DM.


Assuntos
Implantes Dentários , Diabetes Mellitus Tipo 2 , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/cirurgia , Hemoglobinas Glicadas , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA