Acta Bioeng Biomech ; 19(1): 125-131, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28552926

RESUMO

PURPOSE: This computational study explores modelling and finite element study of the implant under Intracranial pressure (ICP) conditions with normal ICP range (7 mm Hg to 15 mm Hg) or increased ICP (>I5 mm Hg). The implant fixation points allow implant behaviour with respect to intracranial pressure conditions. However, increased fixation points lead to variation in deformation and equivalent stress. Finite element analysis is providing a valuable insight to know the deformation and equivalent stress. METHODS: The patient CT data (Computed Tomography) is processed in Mimics software to get the mesh model. The implant is modelled by using modified reverse engineering technique with the help of Rhinoceros software. This modelling method is applicable for all types of defects including those beyond the middle line and multiple ones. It is designed with eight fixation points and ten fixation points to fix an implant. Consequently, the mechanical deformation and equivalent stress (von Mises) are calculated in ANSYS 15 software with distinctive material properties such as Titanium alloy (Ti6Al4V), Polymethyl methacrylate (PMMA) and polyether-ether-ketone (PEEK). RESULTS: The deformation and equivalent stress results are obtained through ANSYS 15 software. It is observed that Ti6Al4V material shows low deformation and PEEK material shows less equivalent stress. Among all materials PEEK shows noticeably good result. CONCLUSIONS: Hence, a concept was established and more clinically relevant results can be expected with implementation of realistic 3D printed model in the future. This will allow physicians to gain knowledge and decrease surgery time with proper planning.


Assuntos
Placas Ósseas , Craniotomia/instrumentação , Modelos Biológicos , Procedimentos de Cirurgia Plástica/instrumentação , Crânio/fisiopatologia , Crânio/cirurgia , Benzofenonas , Materiais Biocompatíveis/química , Cimentos Ósseos/química , Interface Osso-Implante/fisiopatologia , Simulação por Computador , Craniotomia/métodos , Módulo de Elasticidade , Análise de Falha de Equipamento , Análise de Elementos Finitos , Humanos , Pressão Intracraniana , Cetonas/química , Teste de Materiais , Polietilenoglicóis/química , Polímeros , Polimetil Metacrilato/química , Desenho de Prótese , Procedimentos de Cirurgia Plástica/métodos , Estresse Mecânico , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA