Am J Cardiol ; 100(5): 818-23, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17719326

RESUMO

Zotarolimus-eluting phosphorylcholine-coated cobalt-chromium alloy Driver stents (ZES) demonstrated significant reductions in target lesion revascularization rate with few apparent adverse events compared with bare metal stents (BMS; uncoated Driver stents) in a prospective, multicenter, double-blind, randomized controlled trial in de novo coronary lesions. The aim of this study was to examine detailed vascular responses to ZES compared with BMS using serial intravascular ultrasound analysis. A total of 343 patients (ZES n = 178, BMS n = 165) were enrolled in this formal, prespecified intravascular ultrasound substudy of the Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE Zotarolimus-Eluting Driver Coronary Stent in de Novo Native Coronary Artery Lesions (ENDEAVOR II), a prospective, multicenter, double-blind, randomized controlled trial to compare ZES and BMS in de novo native coronary artery lesions. Quantitative and qualitative intravascular ultrasound analyses were performed postprocedurally and at 8-month follow-up in stented and reference segments. ZES showed significantly less neointima, with a larger lumen than BMS at 8 months (percentage neointimal volume 17.6 +/- 10.1% vs 29.4 +/- 17.2%, p <0.0001; maximum percentage neointimal area 32.9 +/- 13.0% vs 47.6 +/- 18.6%, p <0.0001; minimum luminal area 4.9 +/- 1.6 vs 4.0 +/- 1.7 mm(2), p <0.0001) and no unfavorable edge effect. In the 18-mm single stents, ZES showed evenly inhibited neointima compared with BMS. Neither persistent stent-edge dissection nor late-acquired incomplete stent apposition was observed in either group. In conclusion, ZES showed evenly inhibited neointima with no apparent adverse vascular response in stented and reference segments at 8 months compared with BMS.


Assuntos
Ligas de Cromo/química , Materiais Revestidos Biocompatíveis/química , Doença da Artéria Coronariana/cirurgia , Endossonografia , Imunossupressores/uso terapêutico , Fosforilcolina/química , Sirolimo/análogos & derivados , Stents , Estudos de Coortes , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sirolimo/administração & dosagem , Sirolimo/uso terapêutico , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/efeitos dos fármacos
2.
Am J Cardiol ; 96(9): 1251-3, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16253592

RESUMO

To study the interaction of the sirolimus-eluting stent and vessel margins, we analyzed the intravascular ultrasound parameters in 317 edges of 167 stents having 18 edge stenoses at 8 months of follow-up from the SIRIUS trial. Of the baseline parameters, a larger reference percentage of plaque area and a larger edge stent area/reference minimum lumen area were associated with edge stenosis in the sirolimus-eluting stent cohort compared with the incidence of edge stenosis in the bare metal stent cohort. Thus, full lesion coverage and matching the stented segment properly to the adjacent segment using intravascular ultrasound guidance may improve sirolimus-eluting stent implantation efficacy further.


Assuntos
Implante de Prótese Vascular/instrumentação , Materiais Revestidos Biocompatíveis , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Sirolimo/farmacologia , Stents , Ultrassonografia de Intervenção , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Seguimentos , Humanos , Imunossupressores/farmacologia , Metais , Estudos Multicêntricos como Assunto , Razão de Chances , Valor Preditivo dos Testes , Prognóstico , Falha de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco
3.
J Invasive Cardiol ; 15(3): 109-14, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12612382

RESUMO

Treatment with antiproliferative drugs via coated stents appears to be a promising approach to both mechanically remodel target lesions and biologically reduce neointimal hyperplasia. Drug-eluting stents can maximize local drug effects and minimize the potential for systemic toxic effects. The purpose of this review is to describe the effects of a lipophilic microtubular inhibitor, paclitaxel, a strong antiproliferative agent under clinical investigation, and to define the vascular response to taxol-based eluting stents by intravascular ultrasound.


Assuntos
Inibidores da Angiogênese/farmacologia , Inibidores da Angiogênese/uso terapêutico , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/uso terapêutico , Paclitaxel/farmacologia , Paclitaxel/uso terapêutico , Stents , Implante de Prótese Vascular , Procedimentos Cirúrgicos Cardíacos , Ensaios Clínicos como Assunto , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Humanos , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção