Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Am Coll Cardiol ; 42(8): 1360-9, 2003 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-14563575

RESUMO

We compared a conventional stent (Jostent Flex, Jomed GmbH, Rangendingen, Germany) with a polytetrafluoroethylene (PTFE)-membrane-covered stent (Jostent Stentgraft) in patients undergoing intervention of a stenosis in an obstructed vein graft. The use of stents improved results of percutaneous revascularization of obstructed vein grafts, but did not demonstrate the reduced elevated restenosis rate. In addition, long-term clinical event rate is still high compared with intervention in native vessels. Observational studies suggested that stents covered with a PTFE membrane might be associated with a low complication and restenosis rate in venous bypass grafts. This prospective multicenter study included a total of 211 patients who were randomly assigned to receive either a Flex stent or Stentgraft. The primary end point was binary restenosis rate at six months by core lab quantitative coronary angiography. Acute success and procedural events were comparable between the two groups. Restenosis rate was not significantly different between the Flex (20%) and the Stentgraft (29%) groups (p = 0.15), although there was a nonsignificant trend toward a higher late occlusion rate in the Stentgraft group (7% vs. 16%, p = 0.069) at follow-up. Likewise, after a mean observation period of 14 months, cumulative event rates (death, myocardial infarction, or target lesion revascularization) were comparable in the two groups (31% vs. 31%, p = 0.93). This controlled trial does not indicate a superiority of the PTFE-membrane-covered Stentgraft compared with a conventional stent with respect to acute results, restenosis, or clinical event rates.


Assuntos
Prótese Vascular , Materiais Revestidos Biocompatíveis , Ponte de Artéria Coronária , Reestenose Coronária/terapia , Oclusão de Enxerto Vascular/terapia , Politetrafluoretileno , Veia Safena/transplante , Stents , Idoso , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Membranas Artificiais , Estudos Prospectivos , Fatores de Tempo
2.
J Invasive Cardiol ; 15(10): 557-60, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14519886

RESUMO

UNLABELLED: Percutaneous interventions of degenerated saphenous vein grafts (SVG) are associated with high rates of distal embolic events and in-stent restenosis. A novel ePTFE-covered stent graft has been developed to improve outcomes for these difficult lesions. The stent graft has been treated with a 15-amino acid, cell adhesion peptide (P-15) to promote endothelialization on the inner surface post-implantation. Patients with de novo lesions in SVGs were treated with a peptide-coated ePTFE stent graft. Follow-up data was collected at 30 days, 3 and 6 months. An angiographic core lab analyzed an angiographic follow-up at 6 months. RESULTS: Procedural success was achieved in all cases. No device-related major adverse cardiac events occurred in-hospital, at 30 days, or at 3 months, despite the lack of distal protection. Six-month restenosis rates were 21%, and were comparable to similar devices. CONCLUSIONS: The peptide-treated stent graft appears to be a safe and effective treatment for SVG lesions, and has the potential to reduce complications without the use of adjunct distal protection in this patient population.


Assuntos
Materiais Revestidos Biocompatíveis/uso terapêutico , Colágeno/uso terapêutico , Ponte de Artéria Coronária/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Fragmentos de Peptídeos/uso terapêutico , Politetrafluoretileno/uso terapêutico , Veia Safena/patologia , Procedimentos Cirúrgicos Vasculares/instrumentação , Idoso , Prótese Vascular , Ponte de Artéria Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veia Safena/transplante , Stents
3.
Clin Res Cardiol ; 98(11): 731-7, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19697076

RESUMO

AIMS: Restenosis in bare-metal stents is in part related to stent design and material. Optimized strut design of cobalt-chrome (CoCr) stents may yield nearly comparable results to drug-eluting stents (DES) in selected lesions. The prospective multicenter DaVinci registry investigates the clinical outcome of a CoCr coronary stent (MULTI-LINK VISION), particularly in terms of patients with diabetes and complex lesions (B1, B2, C). METHODS AND RESULTS: The prospective internet-based registry included 1,344 patients (76% males, aged 66 +/- 10 years) undergoing stent implantation (n = 1,642) in 32 centres from July 2003 to June 2004. Follow-up data (median 9 +/- 1 months) of this cohort were available for 1,289 patients (98.1%). Of these patients 327 (26.2%) were diabetics. In total, 1,429 de-novo lesions (A 11.9%, B1 47.7%, B2 31.6%, C 8.8%) were treated with the CoCr stent. The predefined primary endpoint was defined as a composite of death, Q-wave myocardial infarction (STEMI), non-STEMI (NSTEMI), target vessel revascularization (TVR) by coronary bypass graft (CABG) or PCI at 270 days (target vessel failure, TVF). Secondary endpoints include death, time to the first myocardial infarction, TVR and CABG. The cumulative incidence of major adverse cardiac events (MACE) was 12.4% with 0.8% deaths, 1.5% non-fatal MI, and 9.7% TVR. TVF in the overall cohort was documented in 137 (10.8%) patients. For diabetics and complex lesions TVF was 13.8% (95% CI 4.2-18) and 11.4% (95% CI 2.0-13.3), respectively. CONCLUSION: This large registry confirms good acute and long-term success of CoCr stents making this strategy valuable, particularly in a special cohort (diabetics and complex lesions) as long as late stent thrombosis with DES plays a role and short-term antiplatelet therapy is favoured.


Assuntos
Doença da Artéria Coronariana/terapia , Reestenose Coronária/etiologia , Diabetes Mellitus/fisiopatologia , Stents , Idoso , Ligas de Cromo , Estudos de Coortes , Doença da Artéria Coronariana/complicações , Feminino , Seguimentos , Humanos , Internet , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
4.
Herz ; 29(2): 181-6, 2004 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-15057439

RESUMO

BACKGROUND: Although randomized, controlled clinical trials (RCTs) showed a reduced target vessel revascularization rate and a good safety profile for the sirolimus-eluting coronary Cypher stent, at least the safety data need to be confirmed by larger data in clinical practice. Under the circumstances of frozen medical budgets in Germany, there may also be a shift toward implantation of a drug-eluting stent (DES) for indications not yet evaluated by RCTs. METHODS: The authors analyzed the data of the German Cypher Registry a nationwide registry which was initiated in parallel to the launch of the first DES, the Cypher stent, in April 2002. RESULTS: From April 2002 until December 2003, 3,579 interventions using a Cypher stent at 102 centers were included in the German Cypher Registry. This reflects a proportion of this DES compared to all stents implanted at the participating centers of < 10%. Patients' median age was 63.4 years (quartiles: 55-70 years) with 75% men. Renal insufficiency was seen in 10.1%, previous myocardial infarction in 37%, prior percutaneous coronary intervention (PCI) in 54.6%, and prior coronary artery bypass grafting (CABG) in 18.7%. In a large proportion of interventions, Cypher stents were implanted in lesions or in clinical situations not yet evaluated by RCTs: 10.1% ST elevation myocardial infarction, 1.8% cardiogenic shock, 2.1% left main stenoses, 5.5% CABG lesions, 23.2% in-stent stenosis, and 6% chronic total occlusions. PCI before DES implantation was performed in 65.5% of cases, a mean of 1.02 +/- 0.43 Cypher stents per lesion were implanted with a median sum length of all Cypher stents per lesion of 18 mm (quartiles: 13-21 mm). Maximum median balloon diameter during stent implantation was 3.00 mm (quartiles: 2.75-3.00 mm). Acute complication rate was low, with 0.2% deaths, 0.3% subacute stent thromboses, 1.3% myocardial infarctions, 2.1% urgent PCIs, and 0.2% CABGs. CONCLUSION: In about one half of the patients included into the German Cypher Registry, the DES were implanted in lesions that were excluded from RCTs. The use of this sirolimus-eluting coronary stent in "real life" conditions was found to be safe concerning acute complications.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Antibióticos Antineoplásicos/administração & dosagem , Materiais Revestidos Biocompatíveis , Reestenose Coronária/prevenção & controle , Estenose Coronária/terapia , Imunossupressores/administração & dosagem , Sirolimo/administração & dosagem , Stents , Administração Tópica , Idoso , Antibióticos Antineoplásicos/efeitos adversos , Antibióticos Antineoplásicos/farmacocinética , Ponte de Artéria Coronária , Reestenose Coronária/sangue , Estenose Coronária/sangue , Vasos Coronários/efeitos dos fármacos , Feminino , Seguimentos , Alemanha , Oclusão de Enxerto Vascular/sangue , Oclusão de Enxerto Vascular/terapia , Humanos , Imunossupressores/efeitos adversos , Imunossupressores/farmacocinética , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Infarto do Miocárdio/sangue , Infarto do Miocárdio/terapia , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Sistema de Registros , Choque Cardiogênico/sangue , Choque Cardiogênico/terapia , Sirolimo/efeitos adversos , Sirolimo/farmacocinética , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA