Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Compend Contin Educ Dent ; 23(6): 531-6, 538, 540 passim; quiz 548, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12789968

RESUMO

The purpose of the study was to compare the efficacy of four mouthrinses in clinical outcomes of changes in oral malodor measurements in a 4-week, randomized, double-blind, longitudinal clinical trial in adults. The four rinses were coded as Products 1, 2, 3, and 4 so that neither the examiners nor subjects had the knowledge of treatment. Of the four mouthrinses, two were commercially available mouthrinses with essential oils (EO) or chlorine dioxide plus zinc (CD/Zn) as active ingredients (Products 1 and 4), one mouthrinse was a formulation containing cetylpyridinium chloride (Product 2), and one was a placebo (Product 3). A total of 99 subjects who met the study criteria were assigned randomly to one of the four groups. At three separate visits (0, 2, and 4 weeks), subjects received an examination of the oral soft tissues and were assessed for baseline oral malodor by two organoleptic judges and a laboratory instrument that measures oral malodor. Subjects were instructed to use the assigned rinse, and the measurements were performed again after 2 and 4 hours. Throughout the 4-week study period, each subject was asked to use the assigned rinse twice daily per the manufacturer's recommended directions. The results showed that the four mouthrinses reduced oral malodor within 4 hours after a single usage, with Product 2 being the most effective and the placebo being the least effective. Daily use of EO, CD/Zn, and placebo rinses for up to 4 weeks did not reduce oral malodor from week 0 baseline values, and the effects on oral malodor were comparable among these three mouthrinses. Product 2 was the only mouthrinse that reduced oral malodor from baseline values after 2 and 4 weeks of daily use.


Assuntos
Anti-Infecciosos Locais/uso terapêutico , Halitose/prevenção & controle , Antissépticos Bucais/uso terapêutico , Adulto , Idoso , Cetilpiridínio/uso terapêutico , Compostos Clorados/uso terapêutico , Método Duplo-Cego , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Odorantes/análise , Óleos Voláteis/uso terapêutico , Óxidos/uso terapêutico , Placebos , Compostos de Enxofre/análise , Resultado do Tratamento
2.
J Clin Dent ; 14(2): 29-33, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12723100

RESUMO

OBJECTIVE: Limited evidence has suggested that a worn toothbrush may be significantly less effective than a new brush with respect to plaque removal. Two independent studies, one with a manual toothbrush and one with a powered toothbrush, were undertaken to compared the ability of these toothbrushes as new and after three months' use to remove plaque. METHODOLOGY: Subjects from a general population were given either an Oral-B CrossAction manual toothbrush (Study 1) or a Braun Oral-B Battery (D4) toothbrush (Study 2). They were instructed to use their respective toothbrushes twice per day for a period of three months. After this time, those subjects meeting the studies' respective inclusion criteria entered the single-use, cross-over phase of the two studies. Both studies involved disclosing the teeth prior to measuring plaque. In Study 1, plaque was recorded using the Proximal Marginal Plaque Index and subjects brushed for one minute, by random assignment, with either a new or a worn toothbrush. In Study 2, plaque was measured using the Modified Quigley-Hein Plaque Index and subjects brushed for two minutes with either new or used brush heads, by random assignment. After a period of approximately one week, subjects returned to the test facilities and brushed with the alternate brush. RESULTS: Study 1 showed that both the new and the worn CrossAction toothbrushes significantly reduced plaque scores (p < 0.0001). A comparison of the two toothbrushes revealed no significant difference for whole-mouth plaque scores; however, at approximal sites the new toothbrush was significantly more effective than the worn brush (p = 0.033). In Study 2, as in Study 1, brushing with either a new or a worn brush head significantly reduced plaque scores (p < 0.0001). A comparison of the efficacies of the new and worn D4 toothbrushes revealed a non-significant tendency for the new brush head to remove more plaque than the worn brush head. However, when plaque removal was assessed for subjects using brush heads with the most extreme wear, i.e., scores of 3 or 4 (n = 15), a significant difference (p < 0.05) between new and worn brush heads was observed for the whole-mouth and approximal surfaces. CONCLUSION: The results from these two studies provide further data in support of the hypothesis that a worn toothbrush is less efficient with respect to plaque removal than a new brush. Patients should therefore be encouraged to replace their toothbrush regularly before bristle wear becomes excessive.


Assuntos
Placa Dentária/terapia , Escovação Dentária/instrumentação , Adolescente , Adulto , Idoso , Estudos Cross-Over , Índice de Placa Dentária , Falha de Equipamento , Reutilização de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA