Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 9(7): 715-24, 2016 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-27056311

RESUMO

OBJECTIVES: The authors sought to investigate the efficacy of a drug-coated balloon (DCB) for treatment of complex femoropopliteal lesions. BACKGROUND: Superiority of DCBs compared with uncoated balloon angioplasty for femoropopliteal interventions has been demonstrated in randomized trials for short lesions. Their performance in complex lesions with higher restenosis rates is unclear. METHODS: Patency, target lesion revascularization (TLR) rate, clinical improvement, and safety endpoints of femoropopliteal lesions in 288 limbs (n = 260) treated with the In.Pact Pacific or Admiral DCB (Medtronic, Minneapolis, Minnesota) were retrospectively analyzed for up to 2 years of follow-up. Predictors of restenosis were identified by logistic regression. RESULTS: Lesions were de novo in 51.7%, restenosis in 11.1%, and in-stent restenosis in 37.2%. Mean lesion length was 24.0 ± 10.2 cm, and 65.3% were occluded. Stent implantation was performed in 23.3%. Kaplan Meier estimates of primary patency were 79.2% and 53.7% for all lesions at 1 and 2 years, respectively, whereas freedom from TLR was 85.4% and 68.6%. Primary patency for in-stent restenosis treatment was 76.6% and 48.6%, and freedom from TLR was 83.0% and 58.7% at 1 and 2 years, respectively. Rutherford category improved from a median 3.3 to 1.2 at 1 year, and to 1.1 at 2 years. Major amputation rate was 2.1% at 2 years. No adverse events were thought to be attributable to the coating of the balloon. CONCLUSIONS: These results suggest that DCB are safe and effective in delaying rather than preventing restenosis in long, complex lesions and restenosis of the femoropopliteal tract. Further studies are recommended to confirm these results.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral/efeitos dos fármacos , Doença Arterial Periférica/terapia , Artéria Poplítea/efeitos dos fármacos , Dispositivos de Acesso Vascular , Idoso , Angioplastia com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA