1.
Am J Cardiol ; 98(5): 616-8, 2006 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16923447

RESUMO

Previous observations in the bare metal stent (BMS) era have demonstrated an association between a high preprocedural C-reactive protein (CRP) level and an increased incidence of death or myocardial infarction after percutaneous coronary intervention (PCI). We hypothesized that PCI with sirolimus-eluting stents (SESs) would result in a smaller increase in CRP compared with BMSs and that a high CRP level before PCI would be associated with a higher incidence of death or myocardial infarction at 12 months, regardless of the type of stent implanted. We analyzed patients who underwent PCI with stenting at the Cleveland Clinic Foundation. Patients who received BMSs and SESs were analyzed separately by categorizing them into low and high CRP groups based on whether their CRP level before PCI was above or below the median for each group. The increase in CRP that occurred with PCI was termed DeltaCRP. In total, 652 patients were included in the analysis. Median DeltaCRP was smaller in the SES group than in the BMS group (1.5 vs 0.7 mg/L, p = 0.009). In the BMS group, patients with a CRP level above the median before PCI had a higher incidence of 12-month death or myocardial infarction compared with patients with a CRP level below the median (11.3% vs 1.6%, p = 0.002). The same relation was present in the SES group, i.e., patients with a higher CRP level had a higher incidence of 12-month death or myocardial infarction compared with patients with a low CRP level (6.3% vs 1.0%, p = 0.005) and a higher 12-month mortality (5.2% vs 0%, p = 0.001). Multivariate logistic regression analysis demonstrated that the CRP level above the median before PCI was associated with a higher 12-month incidence of death or myocardial infarction, independent of the type of stent used, or DeltaCRP. In conclusion, PCI in the SES era causes a smaller increase in CRP compared with the BMS era. A high CRP level before PCI is independently associated with a higher risk of long-term death or myocardial infarction. This finding was present in the BMS and SES groups and highlights the need for aggressive risk-factor modification after PCI.


Assuntos
Implante de Prótese Vascular/instrumentação , Proteína C-Reativa/metabolismo , Materiais Revestidos Biocompatíveis , Doença das Coronárias , Infarto do Miocárdio , Sirolimo/uso terapêutico , Stents , Idoso , Biomarcadores/sangue , Doença das Coronárias/sangue , Doença das Coronárias/mortalidade , Doença das Coronárias/cirurgia , Feminino , Seguimentos , Humanos , Imunossupressores/uso terapêutico , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/epidemiologia , Ohio/epidemiologia , Prognóstico , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo
2.
J Am Coll Cardiol ; 60(19): 1975-84, 2012 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-23103033

RESUMO

OBJECTIVES: This study sought to evaluate the potential utility of a novel polyethylene terephthalate micronet mesh-covered stent (MGuard) in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing percutaneous coronary intervention (PCI). BACKGROUND: Suboptimal myocardial reperfusion after PCI in STEMI is common and results in increased infarct size and mortality. The MGuard is a novel thin-strut metal stent with a polyethylene terephthalate micronet covering designed to trap and exclude thrombus and friable atheromatous debris to prevent distal embolization. METHODS: A total of 433 patients with STEMI presenting within 12 h of symptom onset undergoing PCI were randomized at 50 sites in 9 countries to the MGuard (n = 217) or commercially available bare metal or drug-eluting stents (n = 216). The primary endpoint was the rate of complete (≥70%) ST-segment resolution measured 60 to 90 min post-procedure. RESULTS: Baseline characteristics were well matched between the groups. The primary endpoint of post-procedure complete ST-segment resolution was significantly improved in patients randomized to the MGuard stent compared with control patients (57.8% vs. 44.7%; difference: 13.2%; 95% confidence interval: 3.1% to 23.3%; p = 0.008). By core laboratory analysis, the MGuard stent compared with control stents also resulted in superior rates of Thrombolysis In Myocardial Infarction 3 flow (91.7% vs. 82.9%, p = 0.006) with comparable rates of myocardial blush grade 2 or 3 (83.9% vs. 84.7%, p = 0.81). Mortality (0% vs. 1.9%, p = 0.06) and major adverse cardiac events (1.8% vs. 2.3%, p = 0.75) at 30 days were not significantly different between patients randomized to the MGuard stent and control stent, respectively. CONCLUSIONS: Among patients with acute STEMI undergoing emergent PCI, the MGuard micronet mesh-covered stent compared with conventional metal stents resulted in superior rates of epicardial coronary flow and complete ST-segment resolution. A larger randomized trial is warranted to determine whether these benefits result in reduced infarct size and/or improved clinical outcomes. (Safety and Efficacy Study of MGuard Stent After a Heart Attack [MASTER]; NCT01368471).


Assuntos
Angiografia Coronária , Stents Farmacológicos , Dispositivos de Proteção Embólica , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/instrumentação , Polietilenotereftalatos , Idoso , Trombose Coronária/prevenção & controle , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Complicações Pós-Operatórias , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento