Clin Oral Implants Res ; 28(3): 320-326, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26916561

RESUMO

OBJECTIVE: To evaluate the effects of low- and rapid-resorption-rate bioabsorbable collagen membranes in maxillary sinus augmentation procedure in rabbits considering Schneiderian membrane (SM) reaction and bone tissue formation. MATERIALS AND METHODS: Eighteen male adult rabbits underwent bilateral maxillary sinus augmentation with particulate bovine hydroxyapatite to be divided into three groups, as follows: Group C - control, no membrane; Group RR - rapid resorbable collagen membrane; and Group SR - slow-resorbable collagen membrane. The animals were euthanized after 30 and 120 days for specimen's removal to be prepared and analyzed under light microscopy, histomorphometry, and immunohistochemistry for Runx2 and VEGF labeling. RESULTS: Histopathology evaluation presented similar healing pattern among the groups with a satisfactory response of SM, both at day 30 and day 120. Bone histomorphometry did not reveal significant differences among the groups, as well as immunohistochemistry analysis, which presented intense immunolabeling for both proteins in all groups. CONCLUSIONS: The presence of both membranes did not negatively interfere in bone formation and remodeling, and the focal mild inflammatory reaction caused by their degrading process did not impair the reconstructive procedure.


Assuntos
Substitutos Ósseos , Colágeno , Durapatita , Seio Maxilar/cirurgia , Osteogênese/fisiologia , Levantamento do Assoalho do Seio Maxilar/métodos , Implantes Absorvíveis , Animais , Remodelação Óssea/fisiologia , Bovinos , Masculino , Seio Maxilar/patologia , Modelos Animais , Mucosa Nasal , Coelhos
2.
Implant Dent ; 24(2): 211-6, 2015 04.
Artigo em Inglês | MEDLINE | ID: mdl-25734945

RESUMO

PURPOSE: The aim of this study was to quantify the resistance to torque of different implant systems and their connection devices using in vitro torsion tests. MATERIALS AND METHODS: Three internal connection systems, 1 conventional system with internal torque and 1 conventional system with a mounting device used as a control group were tested on 5 groups. RESULTS: Rupture torque (in newton meter): Biomet 3i Certain group 4 showed a statistically significant higher average (2.65 N·m), followed in order by Biomet 3i Osseotite group 5 (2.18 N·m), Bonelike group 2 (1.80 N·m). Angle deformation/rupture: all groups obtained similar values, without significant differences. Elastic limit (in newton meter): Bonelike group 2 (1.06 N·m) showed similar behavior to group 1 (1.39 N·m) (Nobel Biocare), without significant differences, whereas Bonelike group 3 showed a significantly lower value (0.93 N·m). Maximum torque (in newton meter): Biomet 3i Certain group 4 showed significantly higher values in relation to other groups (2.80 N·m). CONCLUSIONS: The greater contact area the system is built on, the greater resistance against insertion torque, as internal hexagon implants with a greater contact area and external hexagon implants using a mounting device showed higher resistance to insertion torque.


Assuntos
Implantes Dentários , Fenômenos Biomecânicos , Implantes Dentários/normas , Falha de Restauração Dentária , Análise do Estresse Dentário , Técnicas In Vitro , Torque
3.
ImplantNews ; 11(6a): 169-173, 2014. ilus, tab
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-733629

RESUMO

Objetivo: avaliar o limite de resistência de dois diferentes sistemas de grip interno e ligas de titânio para identificar possíveis situações de risco. Material e métodos: foram usados quatro grupos (dez unidades cada), da seguinte forma: 1) implantes de conexão hexagonal externa e liga de titânio grau 4; 2) implantes de conexão hexagonal externa e liga de titânio grau 5; 3) implantes de conexão hexagonal interna e liga de titânio grau 4; 4) implantes de conexão hexagonal interna e liga de titânio grau 5. Chaves de inserção descartáveis foram usadas, e cada conjunto foi submetido ao teste de torção (ASTM F543: 2007) para verificação do torque máximo e valor angular de ruptura. Resultados: os valores médios de torção em cada grupo foram: 203,43 Ncm, 172,65 Ncm, 217,85 Ncm e 181,60 Ncm, respectivamente. Os conjuntos constituídos de liga F67 (grau 4) e conexão morse mostraram maior resistência (teste Anova, p < 0,05). Os valores angulares médios de ruptura foram: 65,76°, 42,18°, 46,30° e 50,52°, respectivamente. Conclusão: os limites de resistência ao torque foram superiores à demanda clínica, o que induz ao raciocínio de que os sistemas são seguros para uso clínico, respeitando seus limites mecânicos. Contudo, o torque excessivo deve ser evitado, em vista do risco de deformação da conexão.


Assuntos
Implantação Dentária Endóssea , Titânio
4.
Rev. Salusvita (Online) ; 26(2): 101-108, 2007. ilus
Artigo em Português | LILACS | ID: lil-559725

RESUMO

A etiologia da Alopécia Areata é multifatorial, porém apresenta-se com algumas controvérsias e sem o conhecimento claro dos fatores determinantes para o seu aparecimento. A correlação existente entre este tipo de enfermidade e as alterações presentes na cavidade bucal, com especial ênfase em focos de infecções e dentes inclusos, ainda se encontra sem comprovação científica, sendo raros os seus relatos na literatura. Os autores relatam um caso clínico, onde estas alterações foram relacionadas com a Alopécia Areata.


Alopecia Areata’s etiology is multifactorial; however there is some controversy and the determining factors for its manifestation are not known. The existing correlation between this type of infirmity and the alterations present in the buccal cavity, with special emphasis on infection foci and impacted teeth, have still not been scientifically proven, and reports on them in the literature are rare. The authors report a clinical case where these alterations were related to Alopecia Areata.


Assuntos
Humanos , Feminino , Adulto , Dente não Erupcionado , Alopecia/etiologia , Odontologia
5.
Rev. dental press periodontia implantol ; 2(2): 80-90, abr.-jun. 2008. ilus, tab, graf
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-605482

RESUMO

O emprego de fixações zigomáticas e implantes convencionais em sistema de carga imediata para reabilitações de maxilas atróficas constitui alternativa recente e vem sendo amplamente descrito na literatura científica, assim como a busca constante pela otimização de índices de sucesso dos implantes. Neste trabalho, procurar-se-á verificar o índice de sobrevida destas fixações, além de verificar o comportamento das FZs em procedimentos de dois estágios e carga imediata, fazendo um estudo retrospectivo de longo prazo, utilizando uma amostra mais representativa. Para este estudo, avaliou-se 59 prontuários de pacientes submetidos a reabilitações maxilares através da instalação de fixações zigomáticas e convencionais, atendidos no período de janeiro de 2000 a dezembro de 2006. Os dados foram registrados por meio de uma ficha cadastral especialmente desenvolvida para este estudo, quantificados e correlacionados. Verificou-se o emprego de 151 FZs e 187 implantes convencionais instalados, sendo 57,63% dos casos com protocolo de duas FZs associadas a quatro implantes convencionais, em sistema de carga imediata. O índice de sucesso foi de 95,36% para as FZs submetidas à carga imediata ou em duas fases cirúrgicas.


The application of zygomatic fixations and conventional implants in a immediate loading system for rehabilitation in atrophic upper jaws consists on a recent alternative and it's being widely described on scientific literature, as well as the constant search of success indexes optimization on implants. On this work, it will be aimed to verify the index of permanence of these fixations, besides verifying the comportment of ZFs in two stages and immediate loading procedures, making a long term retrospective study, using a more representative sample. For this study, 59 handbooks of patients submitted to upper jaw rehabilitations were evaluated, through the installation of zygomatic and conventional fixations. They were attended on the period of January. 2000 to December, 2006. The data were registered through a chart, specially made for this study, quantified and correlated. It could be verified the application of 1 51 ZFs and 187 installed conventional implants, being 57.63% of cases as protocol of two ZFs, associated to four conventionai implants in immediate loading system. The index of success was 95.36% to the ZFs submitted to immediate loading or in two surgical phases.


Assuntos
Humanos , Masculino , Feminino , Carga Imediata em Implante Dentário , Reabilitação Bucal , Maxila/anormalidades , Maxila/cirurgia , Técnicas de Fixação da Arcada Osseodentária , Zigoma
6.
ImplantNews ; 1(6): 489-496, nov.-dez. 2004. ilus, tab, graf
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-415659

RESUMO

A estabilidade inicial vem sendo citada como importante fator de sucesso de reabilitação protética ancorada sobre implantes osseointegrados, em sistema de carga imediata. Analisando a estreita relação entre a definição de estabilidade dos implantes e o método de fresagem, imaginou-se uma relação entre os dados oferecidos pelo Osstell® e a força de resistência ao torque de inserção, que o motor de implante OsseoCare® oferece. Neste estudo verificou-se a inter-relação entre os valores obtidos pelos dois métodos em protocolos inferiores. Da análise dos resultados pôde-se depreender que existe uma correlação negativa entre os métodos. Apesar do resultado, ambos indicaram parâmetros elevados de estabilidade, ficando as diferenças possivelmente relacionadas a detalhes cirúrgicos


Assuntos
Implantação Dentária Endóssea , Osseointegração , Materiais Dentários , Resistência à Tração