Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Nanobiotechnology ; 16(1): 20, 2018 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-29490703

RESUMO

BACKGROUND: Due to the increased emergence of antimicrobial resistance, alternatives to minimize the usage of antibiotics become attractive solutions. Biophysical manipulation of material surface topography to prevent bacterial adhesion is one promising approach. To this end, it is essential to understand the relationship between surface topographical features and bactericidal properties in order to develop antibacterial surfaces. RESULTS: In this work a systematic study of topographical effects on bactericidal activity of nanostructured surfaces is presented. Nanostructured Ormostamp polymer surfaces are fabricated by nano-replication technology using nanoporous templates resulting in 80-nm diameter nanopillars. Six Ormostamp surfaces with nanopillar arrays of various nanopillar densities and heights are obtained by modifying the nanoporous template. The surface roughness ranges from 3.1 to 39.1 nm for the different pillar area parameters. A Gram-positive bacterium, Staphylococcus aureus, is used as the model bacterial strain. An average pillar density at ~ 40 pillars µm-2 with surface roughness of 39.1 nm possesses the highest bactericidal efficiency being close to 100% compared with 20% of the flat control samples. High density structures at ~ 70 pillars µm-2 and low density structures at < 20 pillars µm-2 with surface roughness smaller than 20 nm reduce the bactericidal efficiency to almost the level of the control samples. CONCLUSION: The results obtained here suggests that the topographical effects including pillar density and pillar height inhomogeneity may have significant impacts on adhering pattern and stretching degree of bacterial cell membrane. A biophysical model is prepared to interpret the morphological changes of bacteria on these nanostructures.


Assuntos
Antibacterianos/química , Nanoestruturas/química , Polímeros/química , Staphylococcus aureus/fisiologia , Aderência Bacteriana , Materiais Biocompatíveis/química , Humanos , Viabilidade Microbiana , Nanoestruturas/ultraestrutura , Porosidade , Infecções Estafilocócicas/prevenção & controle , Staphylococcus aureus/citologia , Propriedades de Superfície
2.
ACS Sens ; 9(3): 1382-1390, 2024 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-38478707

RESUMO

Chemiresistive gas sensors composed of a thermoplastic polymer matrix and conductive fillers offer various advantages for detecting volatile organic compounds (VOCs), including low power consumption due to near-room-temperature operation, high sensitivity, and inherent selectivity toward VOCs. However, such sensors have a slow response time as the polymer matrix often has a glass transition temperature (Tg) higher than the sensor operating temperature slowing the analyte diffusion to/from the polymer. A plasticizer lowers polymer Tg to match the sensor operation temperature, reducing its response time. In this study, the effect of a plasticizer diethylene glycol dibenzoate (DEGDB) on the sensing properties of polystyrene (PS)-carbon black (CB) composite is investigated to obtain sensors with a fast response time and high sensitivity to VOCs. The sensors are fabricated via drop-on-demand inkjet printing, providing a high degree of control over the sensory film morphology and reproducibility. A design-of-experiment (DoE) approach is adopted to find the optimum ink and print parameters with a minimum number of experiments. As a result, sensors with 30 times faster response time and 25 times higher effective sensitivity are obtained while operating near room temperature (27 °C). Furthermore, the sensors show high sensitivity toward aromatic hydrocarbons (toluene, benzene, and ethylbenzene), with a sub-10 ppm limit of detection (LoD) and a negligible sensitivity toward humidity. Our results show the potential of PS-DEGDB-CB composite as a selective and cost-effective sensory material compatible with large-scale manufacturing techniques for selective near-room-temperature detection of toxic VOCs.


Assuntos
Polímeros , Compostos Orgânicos Voláteis , Plastificantes , Reprodutibilidade dos Testes , Temperatura
3.
ACS Appl Mater Interfaces ; 12(15): 17244-17253, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32216331

RESUMO

Polymer-derived ceramics (PDC) have recently gained increased interest in the field of bioceramics. Among PDC's, carbon-rich silicon oxycarbide ceramics (SiOC) possess good combined electrical and mechanical properties. Their durability in aggressive environments and proposed cytocompatibility makes them an attractive material for fabrication of bio-MEMS devices such as pacemaker electrodes. The aim of the present study is to demonstrate the remarkable mechanical and electrical properties, biological response of PDCs modified with titanium (Ti) and their potential for application as pacemaker electrodes. Therefore, a new type of SiOC modified with Ti fillers was synthesized via PDC route using a Pt-catalyzed hydrosilylation reaction. Preceramic green bodies were pyrolyzed at 1000 °C under an argon atmosphere to achieve amorphous ceramics. Electrical and mechanical characterization of SiCxO2(1-x)/TiOxCy ceramics revealed a maximum electrical conductivity of 10 S cm-1 and a flexural strength of maximal 1 GPa, which is acceptable for pacemaker applications. Ti incorporation is found to be beneficial for enhancing the electrical conductivity of SiOC ceramics and the conductivity values were increased with Ti doping and reached a maximum for the composition with 30 wt % Ti precursor. Cytocompatibility was demonstrated for the PDC SiOC ceramics as well as SiOC ceramics modified with Ti fillers. Cytocompatibility was also demonstrated for SiTiOC20 electrodes under pacing conditions by monitoring of cells in an in vitro 3D environment. Collectively, these data demonstrate the great potential of polymer-derived SiOC ceramics to be used as pacemaker electrodes.


Assuntos
Materiais Biocompatíveis/química , Compostos Inorgânicos de Carbono/química , Cerâmica/química , Polímeros/química , Compostos de Silício/química , Titânio/química , Materiais Biocompatíveis/farmacologia , Células Cultivadas , Condutividade Elétrica , Eletrodos Implantados , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Fibroblastos/fisiologia , Humanos , Teste de Materiais , Análise Espectral Raman , Temperatura
4.
Adv Healthc Mater ; 8(20): e1900379, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31532887

RESUMO

In cochlear implants, the electrode insertion trauma during surgery can cause damage residual hearing. Preserving the residual hearing is an important challenge and the localized administration of drugs, such as steroids, is one of the most promising ways, but remains a challenge. Here, a microscaffold cochlear electrode array (MiSCEA) consisting of a microfabricated flexible electrode array and a 3D microscaffold for steroid reservoir is reported. The MiSCEA without loaded drug is tested by measuring the electrically evoked auditory brainstem response of the cochlea in guinea pigs (n = 4). The scaffold is then coated with steroid (dexamethasone) encapsulated in polylactic-co-glycolic acid and the continuous release of the steroid into artificial perilymph during six weeks is monitored. The steroid-containing scaffolds are then implanted into guinea pigs (n = 4) and threshold shifts are analyzed for four weeks by measuring the acoustically evoked auditory brainstem response. The threshold shifts tend to be lower in the group implanted with the steroid-containing MiSCEAs. The feasibility of 3D MiSCEA opens up the development of potential next-generation cochlear electrode with improved steroid release dynamics into cochlea.


Assuntos
Implante Coclear/efeitos adversos , Dexametasona/administração & dosagem , Sistemas de Liberação de Medicamentos , Eletrodos Implantados , Impressão Tridimensional , Esteroides/administração & dosagem , Animais , Calibragem , Cóclea/fisiologia , Implantes Cocleares , Potenciais Evocados Auditivos do Tronco Encefálico , Cobaias , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Alicerces Teciduais
5.
Nat Nanotechnol ; 11(2): 147-51, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26595334

RESUMO

The success of high-speed atomic force microscopy in imaging molecular motors, enzymes and microbes in liquid environments suggests that the technique could be of significant value in a variety of areas of nanotechnology. However, the majority of atomic force microscopy experiments are performed in air, and the tapping-mode detection speed of current high-speed cantilevers is an order of magnitude lower in air than in liquids. Traditional approaches to increasing the imaging rate of atomic force microscopy have involved reducing the size of the cantilever, but further reductions in size will require a fundamental change in the detection method of the microscope. Here, we show that high-speed imaging in air can instead be achieved by changing the cantilever material. We use cantilevers fabricated from polymers, which can mimic the high damping environment of liquids. With this approach, SU-8 polymer cantilevers are developed that have an imaging-in-air detection bandwidth that is 19 times faster than those of conventional cantilevers of similar size, resonance frequency and spring constant.


Assuntos
Microscopia de Força Atômica/métodos , Nanotecnologia/métodos , Compostos de Epóxi/química , Desenho de Equipamento , Nanoestruturas/química , Polímeros/química
6.
J Biomed Mater Res A ; 103(11): 3625-32, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25851039

RESUMO

Ceramics are known to be chemically stable, and the possibility to electrically dope polymer-derived ceramics makes it a material of interest for implantable electrode applications. We investigated cytotoxic characteristics of four polymer-derived ceramic candidates with either electrically conductive or insulating properties. Cytotoxicity was assessed by culturing C2C12 myoblast cells under two conditions: by exposing them to material extracts and by putting them directly in contact with material samples. Cell spreading was optically evaluated by comparing microscope observations immediately after the materials insertion and after 24 h culturing. Cell viability (MTT) and mortality (LDH) were quantified after 24-h incubation in contact with the materials. Comparison was made with biocompatible positive references (alumina, platinum, biocompatible stainless steel 1.4435), negative references (latex, stainless steel 1.4301) and controls (no material present in the culture wells). We found that the cytotoxic properties of tested ceramics are comparable to established reference materials. These ceramics, which are reported to be very stable, can be microstructured and electrically doped to a wide range of conductivity and are thus excellent candidates for implantable electrode applications including pacemakers.


Assuntos
Cerâmica/farmacologia , Teste de Materiais/métodos , Marca-Passo Artificial , Polímeros/farmacologia , Animais , Morte Celular/efeitos dos fármacos , Linhagem Celular , Movimento Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Eletrodos , L-Lactato Desidrogenase/metabolismo , Camundongos
7.
ACS Nano ; 6(6): 5474-81, 2012 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-22594808

RESUMO

The development of nanoscale lithographic methods on polymer materials is a key requirement to improve the spatial resolution and performance of flexible devices. Here, we report the fabrication of metallic nanostructures down to 20 and 50 nm in size on polymer materials such as polyimide, parylene, SU-8, and PDMS substrates without any resist processing using stencil lithography. Metallic nanodot array analysis of their localized surface plasmon spectra is included. We demonstrate plasmon resonance detection of biotin and streptavidin using a PDMS flexible film with gold nanodots. We also demonstrate the fabrication of metallic nanowires on polyimide substrates with their electrical characteristics showing an ohmic behavior. These results demonstrate high-resolution nanopatterning and device nanofabrication capability of stencil lithography on polymer and flexible substrates.


Assuntos
Técnicas Biossensoriais/instrumentação , Imunoensaio/instrumentação , Impressão Molecular/métodos , Nanopartículas/química , Nanopartículas/ultraestrutura , Polímeros/química , Ressonância de Plasmônio de Superfície/instrumentação , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA