RESUMO
OBJECTIVE: To describe a novel orthodontic appliance to prevent pedicle trauma in patients undergoing double-opposing buccal flap surgery for secondary palatal lengthening. DESIGN: Case series. SETTING: Cleft and craniofacial clinic, Johns Hopkins Children's Center. PATIENTS, PARTICIPANTS: Four patients undergoing double-opposing buccal flap surgery for repair of velopharyngeal insufficiency. INTERVENTIONS: Patients were fitted with the device, which consists of a lower lingual holding arch with acrylic bite blocks. MAIN OUTCOME MEASURE: Presence of pedicle trauma postsurgery and tolerability of the device. RESULTS: The appliance was well tolerated in all 4 patients and no biting trauma to the pedicles was observed. CONCLUSIONS: A reliable appliance has been developed to prevent biting trauma to the pedicles in patients undergoing double-opposing buccal flap surgery in the permanent dentition stage.