Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Endovasc Ther ; 25(1): 68-78, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29285955

RESUMO

PURPOSE: To evaluate the safety and effectiveness of the TIGRIS stent for lesions up to 24 cm in the superficial femoral and proximal popliteal arteries (SFA/PPA). METHODS: This prospective, multicenter, randomized study enrolled 274 subjects at 36 sites in the United States and Europe. Subjects were randomly assigned in a 3:1 ratio to treatment with the TIGRIS stent (n=197; mean age 66.7±9.28 years; 141 men) or LifeStent (n=70; mean age 67.9±8.87 years; 49 men). The primary safety endpoint was 30-day freedom from major adverse events (MAE). The primary efficacy endpoint was primary patency at 12 months. Secondary endpoints included target lesion revascularization (TLR) and stent fracture. Clinical success and quality of life were also assessed. RESULTS: Mean lesion length (107.6 vs 117.9 mm, p=0.29), procedure success (99.5% vs 97.1%, p=0.17), and freedom from MAE (99.5% vs 100%, p>0.99) were similar for the TIGRIS and control groups, respectively. Likewise, there was no difference in primary patency at 12 months (60.6% vs 63.2%, p=0.73) or 24 months (56.3% vs 50.2%, p=0.60) or in TLR at the same time points (76.6% vs 80.6%, p=0.49; 70.5% vs 67.2%, p=0.85). There were no differences in the changes in Rutherford category or the ankle/brachial index through 24 months. The rate of stent fracture was lower for TIGRIS compared with LifeStent (0% vs 32.7%, p<0.001). CONCLUSION: The TIGRIS stent and LifeStent were similarly effective for the treatment of lesions in the SFA and PPA. The high flexibility and zero fracture rate associated with the TIGRIS stent make this device favorable for use in high-flexion arteries.


Assuntos
Ligas , Procedimentos Endovasculares/instrumentação , Artéria Femoral , Doença Arterial Periférica/cirurgia , Artéria Poplítea , Stents Metálicos Autoexpansíveis , Idoso , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA