Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Int J Mol Sci ; 15(7): 13030-44, 2014 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-25056542

RESUMO

The present work presents new bactericidal coatings, based on two families of non-toxic, antimicrobial glasses belonging to B2O3-SiO2-Na2O-ZnO and SiO2-Na2O-Al2O3-CaO-B2O3 systems. Free of cracking, single layer direct coatings on different biomedical metallic substrates (titanium alloy, Nb, Ta, and stainless steel) have been developed. Thermal expansion mismatch was adjusted by changing glass composition of the glass type, as well as the firing atmosphere (air or Ar) according to the biomedical metallic substrates. Formation of bubbles in some of the glassy coatings has been rationalized considering the reactions that take place at the different metal/coating interfaces. All the obtained coatings were proven to be strongly antibacterial versus Escherichia coli (>4 log).


Assuntos
Cálcio/química , Vidro/química , Zinco/química , Ligas/química , Ligas/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Escherichia coli/efeitos dos fármacos , Propriedades de Superfície , Titânio/química
2.
Antibiotics (Basel) ; 13(8)2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39199990

RESUMO

This study evaluates the dynamic shift in the microbiota at the peri-implant site of titanium (Ti) and zirconia (Zr) implants subjected to experimental peri-implantitis (PI) and, for the first time, of implants made of ceria-stabilized alumina-reinforced zirconia (Ce-TZP/Al), a revolutionary zirconia that is set to play a key role in modern implant dentistry. One- and two-piece (TP) implants, including Ce-TZP/AL TP/G3 glass, were placed bilaterally (six implants/side) in five beagle dogs to mimic a natural vs. ligature-induced PI following a split-mouth design. The experiment spanned 30 weeks from tooth extraction. Both PI models promoted plaque deposition at peri-implant sites. Comparatively, the PI induced by ligatures favored the deposition of anaerobes (p = 0.047 vs. natural). Regardless of the model, the plaque deposition pattern was entirely dependent on the implanted material. Ligated Ti and Zr implant sites accumulated up to 2.14 log CFU/mL unit anaerobic load (p ≤ 0.033 vs. non-ligated implant sites), predominantly comprising obligate anaerobes. Naturally occurring PI induced the deposition of co-occurring networks of obligate anaerobes and less oxygen-dependent bacteria. PI induction favored the enrichment of Ti and Zr sites with bacterial taxa belonging to the orange and red complexes (up to 28% increase naturally and up to 71% in the ligated hemiarch). Anaerobic deposition was significantly lower in ligated Ce-TZP/Al implant sites (p ≤ 0.014 vs. TI and Zr) and independent of the induction model (0.63-1 log units of increase). Facultative bacteria prevailed at Ce-TZP/AL sites. The abundance was lower in the Ce-TZP/AL TP implant. Unlike Ti and Zr sites, taxa from the orange and red complexes were negligible. Biofilms configured at the Ti and Zr sites after ligation-induced PI resemble those found in severe IP. We hypothesize that, although surface properties (surface energy and surface roughness) and physicochemical properties of the substrate play an important role in bacterial adhesion and subsequent plaque formation, Ce-TZP/Al modulates several biological activities that preserve the integrity of the gingival seal by limiting PI progression. In conclusion, biofilm progression differs in peri-implant sites according to the specific properties of the material. Ce-TZP/A, unlike titanium or zirconia, prevents dysbiosis in sites subjected to experimental PI and preserves the microbial signature of emergent obligate anaerobes related to PI development.

3.
Materials (Basel) ; 15(15)2022 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-35955356

RESUMO

The choice of suitable materials and new designs in oral implantology and the subsequent enhancement of the characteristics of the dental implant developed is an important research topic with wide scope. The present work aims to develop a new multifunctional zirconia-ceria/alumina (Ce-TZP/Al2O3) composite with an antimicrobial glass-based coating to be used in multi-unit abutments compatible with commercially available Ti implants for peri-implantitis prevention. An airbrush spraying technique was effectively applied to coat the sintered ceramic composite starting from a glass powder suspension. This deposition technique was appropriate for obtaining continuous antimicrobial glass-based coatings with homogenous thickness (~35 µm) on ceramic dental implant components. The dental implant systems with the antimicrobial glassy coating were subjected to a mechanical integrity test following ISO 14801 to determine their long-term stability. The tested implant-coating structure seems to be stable under in vitro conditions with ultimate applied forces exceeding the maximum physiological occlusal loading force. This paper also presents a pilot clinical case report that shows peri-implant tissue around the mechanically stable glass coating with no signs of inflammation 1 year after implant insertion. This result is a preliminary probe of the durability and biological tolerance of the glassy material by the gingiva, as well as the antimicrobial effect on the peri-implant microbiota displayed by the coating.

4.
Antibiotics (Basel) ; 10(10)2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-34680764

RESUMO

Current endodontic procedures continue to be unsuccessful for completely removing pathogens present inside the root canal system, which can lead to recurrent infections. In this study, we aimed to assess the antimicrobial capacity and tissue response of two inorganic bactericidal additives incorporated into a paste root canal sealer on contaminated root dentin in vivo. An experimental study was performed in 30 teeth of five Beagle dogs. After inducing microbiological contamination, root canal systems were treated by randomly incorporating one of two antimicrobial additives into a commercial epoxy-amine resin sealer (AH Plus), i.e., G3T glass-ceramic (n = 10) and ZnO-enriched glass (n = 10); 10 samples were randomized as a control group. After having sacrificed the animals, microbiological, radiological, and histological analyses were performed, which were complemented with an in vitro bactericidal test and characterization by field emission scanning electron microscopy. The tested groups demonstrated a non-significant microbiological reduction in the postmortem periapical index values between the control group and the bactericidal glass-ceramic group (p = 0.885), and between the control group and the ZnO-enriched glass group (p = 0.169). The histological results showed low values of inflammatory infiltrate, and a healing pattern characterized by fibrosis in 44.4% of the G3T glass-ceramic and 60.0% of ZnO-enriched glass. Bactericidal glassy additives incorporated in this root canal sealer are safe and effective in bacterial reduction.

5.
Sci Rep ; 9(1): 2762, 2019 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-30808968

RESUMO

This study investigates a novel approach to controlling biofilms of the most frequent pathogens implicated in the etiology of biomaterials-associated infections. New bactericidal filler based on a non-toxic glass, belonging to B2O3-SiO2-Al2O3-Na2O-ZnO system, was used to formulate composites of the most widely used polymers in biomedical applications [i.e. thermoplastic polyurethane (TPU) and polydimethyl siloxane (PDMS)], with varying percentage by weight of the bactericidal glass (5, 15, 25, 35, 50%). Glass-filled polymer composites show dramatically restricted bacterial colonisation and biofilm formation. They exhibit time- and dose-dependent killing, with maximal action at 5 days. The highest activity was found against S.epidermidis biofilm (99% of reduction), one of the most common cause of nosocomial infections. The tensile properties of the obtained glass-filled composites are comparable with the literature data concerning polymeric biomaterials for medical implants and devices. In addition, all the materials presented in this research, revealed an excellent biocompatibility. This was disclosed by cell viability values above 70%, none alteration on erythrocyte membrane or cell functionality in contact with materials (haemolytic index 0-2%), and absence of interferences in blood coagulation (intrinsic, extrinsic and final pathways).


Assuntos
Materiais Biocompatíveis/farmacologia , Biofilmes/efeitos dos fármacos , Dimetilpolisiloxanos/química , Vidro/química , Poliuretanos/química , Óxido de Zinco/química , Óxido de Alumínio/química , Materiais Biocompatíveis/química , Compostos de Boro/química , Eritrócitos/citologia , Eritrócitos/metabolismo , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Positivas/efeitos dos fármacos , Hemólise/efeitos dos fármacos , Humanos , Testes de Sensibilidade Microbiana , Óxidos/química , Dióxido de Silício/química , Compostos de Sódio/química , Staphylococcus epidermidis/fisiologia , Propriedades de Superfície , Resistência à Tração
6.
J Biomed Mater Res A ; 107(7): 1466-1475, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30786152

RESUMO

The idea of permanent tooth replacement goes back to the year 2000 BC at least, when carved bamboo pegs were used to replace missing teeth in ancient China. The phenomenon of osseointegration, however, was not verified until the mid-1960s, when Branemark discovered that titanium could integrate to bone. Since then, the osseointegration capacity of implants has been profoundly investigated and implants as such have evolved enormously in all possible aspects, from material selection and processing to specific surface engineering, among many others. This review article, in particular, focuses on dental implants and aims to introduce the main concerns involved in modern dentistry, concentrating especially on the importance of finding an effective way to prevent peri-implantitis. In this sense, strategies such as shifting from metal to ceramic implant components and applying novel antimicrobial antibiotic-free coatings seem to be taking the lead. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2019.


Assuntos
Implantes Dentários/tendências , Odontologia/tendências , Estética , Fenômenos Mecânicos , Peri-Implantite/prevenção & controle , Anti-Infecciosos/farmacologia , Humanos , Peri-Implantite/diagnóstico por imagem
7.
Sci Rep ; 6: 31478, 2016 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-27515388

RESUMO

Bacterial and fungal infections remain a major clinical challenge. Implant infections very often require complicated revision procedures that are troublesome to patients and costly to the healthcare system. Innovative approaches to tackle infections are urgently needed. We investigated the histological response of novel free P2O5 glass-ceramic rods implanted in the jaws of beagle dogs. Due to the particular percolated morphology of this glass-ceramic, the dissolution of the rods in the animal body environment and the immature bone formation during the fourth months of implantation maintained the integrity of the glass-ceramic rod. No clinical signs of inflammation took place in any of the beagle dogs during the four months of implantation. This new glass-ceramic biomaterial with inherent bactericidal and fungicidal properties can be considered as an appealing candidate for bone tissue engineering.


Assuntos
Antibacterianos/química , Compostos de Cálcio/química , Cerâmica/química , Arcada Osseodentária/patologia , Óxidos/química , Próteses e Implantes , Hidróxido de Sódio/química , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Cães , Microscopia Eletrônica de Varredura , Procedimentos Cirúrgicos Ortognáticos , Osseointegração/efeitos dos fármacos , Porosidade , Próteses e Implantes/veterinária , Espectrometria por Raios X , Tomografia Computadorizada por Raios X
8.
PLoS One ; 10(7): e0132709, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26230940

RESUMO

A new family of non-toxic biocides based on low melting point (1250°C) transparent glasses with high content of ZnO (15-40wt%) belonging to the miscibility region of the B2O3-SiO2-Na2O-ZnO system has been developed. These glasses have shown an excellent biocide activity (logarithmic reduction >3) against Gram- (E. coli), Gram+ (S. aureus) and yeast (C. krusei); they are chemically stable in different media (distilled water, sea-like water, LB and DMEN media) as well as biocompatible. The cytotoxicity was evaluated by the Neutral Red Uptake using NIH-3T3 (mouse embryonic fibroblast cells) and the cell viability was >80%. These new glasses can be considered in several and important applications in the field of inorganic non-toxic biocide agents such as medical implants, surgical equipment, protective apparels in hospitals, water purifications systems, food packaging, food storages or textiles.


Assuntos
Antibacterianos/farmacologia , Antifúngicos/farmacologia , Materiais Biocompatíveis/farmacologia , Vidro/química , Óxido de Zinco/farmacologia , Candida/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Teste de Materiais , Testes de Sensibilidade Microbiana , Staphylococcus aureus/efeitos dos fármacos
9.
PLoS One ; 10(10): e0140374, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26489088

RESUMO

OBJECTIVES: The aim of the present study is to evaluate, in a ligature-induced peri-implantitis model, the efficacy of three antimicrobial glassy coatings in the prevention of biofilm formation, intrasulcular bacterial growth and the resulting peri-implant bone loss. METHODS: Mandibular premolars were bilaterally extracted from five beagle dogs. Four dental implants were inserted on each hemiarch. Eight weeks after, one control zirconia abutment and three with different bactericidal coatings (G1n-Ag, ZnO35, G3) were connected. After a plaque control period, bacterial accumulation was allowed and biofilm formation on abutments was observed by Scanning Electron Microscopy (SEM). Peri-implantitis was induced by cotton ligatures. Microbial samples and peri-implant crestal bone levels of all implant sites were obtained before, during and after the breakdown period. RESULTS: During experimental induce peri-implantitis: colony forming units counts from intrasulcular microbial samples at implants with G1n-Ag coated abutment remained close to the basal inoculum; G3 and ZnO35 coatings showed similar low counts; and anaerobic bacterias counts at control abutments exhibited a logarithmic increase by more than 2. Bone loss during passive breakdown period was no statistically significant. Additional bone loss occurred during ligature-induce breakdown: 0.71 (SD 0.48) at G3 coating, 0.57 (SD 0.36) at ZnO35 coating, 0.74 (SD 0.47) at G1n-Ag coating, and 1.29 (SD 0.45) at control abutments; and statistically significant differences (p<0.001) were found. The lowest bone loss at the end of the experiment was exhibited by implants dressing G3 coated abutments (mean 2.1; SD 0.42). SIGNIFICANCE: Antimicrobial glassy coatings could be a useful tool to ward off, diminish or delay peri-implantitis progression.


Assuntos
Perda do Osso Alveolar/prevenção & controle , Anti-Infecciosos/farmacologia , Biofilmes/crescimento & desenvolvimento , Implantação Dentária Endóssea/métodos , Peri-Implantite/prevenção & controle , Animais , Bactérias/crescimento & desenvolvimento , Dente Pré-Molar/cirurgia , Biofilmes/efeitos dos fármacos , Compostos de Cálcio/farmacologia , Dente Suporte/microbiologia , Implantação Dentária Endóssea/efeitos adversos , Implantes Dentários/efeitos adversos , Placa Dentária/microbiologia , Planejamento de Prótese Dentária , Cães , Vidro/química , Testes de Sensibilidade Microbiana , Microscopia Eletrônica de Varredura , Modelos Animais , Osseointegração , Óxidos/farmacologia , Prata/farmacologia , Hidróxido de Sódio/farmacologia , Propriedades de Superfície , Leveduras/crescimento & desenvolvimento , Óxido de Zinco/análogos & derivados , Óxido de Zinco/farmacologia
10.
PLoS One ; 9(1): e86926, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24466292

RESUMO

The aim of the present study was to evaluate bone loss at implants connected to abutments coated with a soda-lime glass containing silver nanoparticles, subjected to experimental peri-implantitis. Also the aging and erosion of the coating in mouth was studied. Five beagle dogs were used in the experiments. Three implants were placed in each mandible quadrant: in 2 of them, Glass/n-Ag coated abutments were connected to implant platform, 1 was covered with a Ti-mechanized abutment. Experimental peri-implantitis was induced in all implants after the submarginal placement of cotton ligatures, and three months after animals were euthanatized. Thickness and morphology of coating was studied in abutment cross-sections by SEM. Histology and histo-morphometric studies were carried on in undecalfied ground slides. After the induced peri-implantitis: 1.The abutment coating shown losing of thickness and cracking. 2. The histometry showed a significant less bone loss in the implants with glass/n-Ag coated abutments. A more symmetric cone of bone resorption was observed in the coated group. There were no significant differences in the peri-implantitis histological characteristics between both groups of implants. Within the limits of this in-vivo study, it could be affirmed that abutments coated with biocide soda-lime-glass-silver nanoparticles can reduce bone loss in experimental peri-implantitis. This achievement makes this coating a suggestive material to control peri-implantitis development and progression.


Assuntos
Perda do Osso Alveolar/patologia , Implantes Dentários/efeitos adversos , Nanopartículas Metálicas/efeitos adversos , Perda do Osso Alveolar/etiologia , Animais , Compostos de Cálcio , Dente Suporte , Cães , Vidro , Nanopartículas Metálicas/química , Óxidos , Peri-Implantite/fisiopatologia , Prata , Titânio
11.
Sci Rep ; 4: 5440, 2014 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-24961911

RESUMO

In the attempt to find valid alternatives to classic antibiotics and in view of current limitations in the efficacy of antimicrobial-coated or loaded biomaterials, this work is focused on the development of a new glass-ceramic with antibacterial performance together with safe biocompatibility. This bactericidal glass-ceramic composed of combeite and nepheline crystals in a residual glassy matrix has been obtained using an antimicrobial soda-lime glass as a precursor. Its inhibitory effects on bacterial growth and biofilm formation were proved against five biofilm-producing reference strains. The biocompatibility tests by using mesenchymal stem cells derived from human bone indicate an excellent biocompatibility.


Assuntos
Antibacterianos/farmacologia , Cerâmica/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Viabilidade Microbiana/efeitos dos fármacos , Compostos de Alumínio/química , Antibacterianos/química , Apoptose/efeitos dos fármacos , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Compostos de Cálcio/química , Caspase 3/metabolismo , Adesão Celular/efeitos dos fármacos , Células Cultivadas , Cerâmica/química , Materiais Revestidos Biocompatíveis/química , Ativação Enzimática/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Escherichia coli/fisiologia , Humanos , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/enzimologia , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Óxidos/química , Silicatos/química , Compostos de Sódio/química , Hidróxido de Sódio/química , Propriedades de Superfície , Termografia , Fatores de Tempo , Difração de Raios X
12.
PLoS One ; 7(8): e42393, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22879961

RESUMO

This paper reports the effect of soda-lime-glass-nAg coating on the viability of an in vitro biofilm of Streptococcus oralis. Three strains (ATCC 35037 and two clinical isolates from periodontitis patients) were grown on coated with glass, glass containing silver nanoparticles, and uncoated titanium alloy disks. Two different methods were used to quantify biofilm formation abilities: crystal violet staining and determination of viable counts. The influence of the surface morphology on the cell attachment was studied. The surface morphology was characterized by scanning electron microscopy (SEM) and using a profilometer. SEM was also used to study the formation and the development of biofilm on the coated and uncoated disks. At least a >99.7% inocula reduction of biofilm respect to titanium disks and also to glass coated disks was observed in the glass-nAg coated disks for all the studied strains. A quantitative evaluation of the release of silver was conducted in vitro to test whether and to what extend the biocidal agent (silver) could leach from the coating. These findings suggest that the biofilm formation of S. oralis strains is highly inhibited by the glass-nAg and may be useful for materials which require durable antibacterial effect on their surfaces, as it is the case of dental implants.


Assuntos
Biofilmes/efeitos dos fármacos , Compostos de Cálcio/farmacologia , Vidro/química , Nanopartículas Metálicas/química , Óxidos/farmacologia , Prata/farmacologia , Hidróxido de Sódio/farmacologia , Streptococcus oralis/fisiologia , Titânio/farmacologia , Ligas , Aderência Bacteriana/efeitos dos fármacos , Violeta Genciana , Humanos , Nanopartículas Metálicas/ultraestrutura , Plâncton/efeitos dos fármacos , Coloração e Rotulagem , Streptococcus oralis/efeitos dos fármacos , Streptococcus oralis/ultraestrutura , Propriedades de Superfície , Temperatura
13.
PLoS One ; 7(12): e52861, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23285206

RESUMO

The objective of the present study is to evaluate bone loss at implant abutments coated with a soda-lime glass containing silver nanoparticles subjected to experimental peri-implantitis. Five beagle dogs were used in the experiments, 3 implants were installed in each quadrant of the mandibles. Glass/n-Ag coted abutments were connected to implant platform. Cotton floss ligatures were placed in a submarginal position around the abutment necks and the animals were subject to a diet which allowed plaque accumulation, and after 15 weeks the dogs were sacrificed. Radiographs of all implant sites were obtained at the beginning and at the end of the experimentally induced peri-implantitis. The radiographic examination indicated that significant amounts of additional bone loss occurred in implants without biocide coating, considering both absolute and relative values of bone loss. Percentages of additional bone loss observed in implants dressed with a biocide coated abutment were about 3 times lower (p<0.006 distal aspect; and p<0.031 at mesial aspect) than the control ones. Within the limits of the present study it seems promising the use of soda-lime glass/nAg coatings on abutments to prevent peri-implant diseases.


Assuntos
Perda do Osso Alveolar/diagnóstico por imagem , Dente Suporte , Implantes Dentários/efeitos adversos , Desinfetantes/administração & dosagem , Doenças Maxilares/diagnóstico por imagem , Peri-Implantite/diagnóstico por imagem , Titânio , Algoritmos , Perda do Osso Alveolar/etiologia , Animais , Materiais Revestidos Biocompatíveis/efeitos adversos , Materiais Revestidos Biocompatíveis/farmacologia , Dente Suporte/efeitos adversos , Implantação Dentária Endóssea/efeitos adversos , Implantação Dentária Endóssea/métodos , Implantação Dentária Endóssea/microbiologia , Planejamento de Prótese Dentária , Cães , Doenças Maxilares/etiologia , Peri-Implantite/complicações , Peri-Implantite/prevenção & controle , Radiografia , Propriedades de Superfície , Titânio/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA