Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 93(7): E394-E399, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30536530

RESUMO

BACKGROUND: Trans-catheter closure of coronary artery fistulae (CAF) has become a successful alternative to cardiac surgery with excellent results and acceptable low rate of complications. Different techniques and devices are available to treat the extreme anatomical variability of CAF. AIM: We retrospectively describe our case series of five patients trans-radially treated using an Amplatzer vascular plug IV (AVP-IV) with telescoping catheter technique. RESULTS: Trans-radial closure of CAF using the "Child in Mother" technique with dedicated catheters to deliver the vascular plugs AVP-IV was successfully performed in all patients, in one case for a complex CAF, an hybrid step approach using coils and plugs was needed. CONCLUSIONS: Trans-radial closure of CAF using AVP-IV and a telescoping catheter appeared to be safe and feasible in our case series. A persistent closure of CAF was achieved in all patients at 2 year coronary angiography follow-up.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateterismo Periférico , Anomalias dos Vasos Coronários/terapia , Embolização Terapêutica/instrumentação , Artéria Radial , Fístula Vascular/terapia , Adulto , Idoso , Ligas , Cateterismo Cardíaco/efeitos adversos , Cateteres Cardíacos , Cateterismo Periférico/efeitos adversos , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/fisiopatologia , Embolização Terapêutica/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Estudos Retrospectivos , Resultado do Tratamento , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/fisiopatologia
2.
Eur Heart J ; 39(26): 2448-2456, 2018 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-29788263

RESUMO

Aims: Delayed healing and endothelial dysfunction may occur with drug-eluting stents (DES), promoting accelerated infiltration of lipids in the neointima and development of neoatherosclerosis (NA). Pathology data suggest durable polymer (DP) of DES to play a major role in this process. Whether biodegradable polymer (BP) may address these issues is uncertain. We compared in vivo vessel healing and NA of current generation BP- or DP-DES using serial optical coherence tomography (OCT) assessments. Methods and results: Ninety patients with multivessel coronary artery disease were randomized 1:1 to BP everolimus-eluting stents (EES, Synergy) or DP zotarolimus-eluting stents (ZES, Resolute Integrity). Co-primary endpoints were the maximum length of uncovered struts at 3 months (powered for non-inferiority) and the percentage of patients presenting with frames of NA at 18 months (powered for superiority) as measured by OCT. The maximum length of uncovered struts at 3 months was 10 ± 8 mm in the BP-EES group and 11 ± 7 mm in the DP-ZES group (mean difference -1 mm; upper 97.5% confidence interval +2 mm; P = 0.05 for non-inferiority; P = 0.45 for superiority). The percentage of patients presenting with frames of NA at 18 months was low and similar between BP-EES and DP-ZES groups (11.6% vs. 15.9%; P = 0.56). There was no stent thrombosis in both groups at 24 months. Conclusion: BP-EES and DP-ZES showed a similar healing response at 3 months and a low incidence of NA at 18 months. Biocompatible polymers, regardless of whether they are durable or biodegradable, may favourably impact the long-term vascular response to current-generation DES.


Assuntos
Implantes Absorvíveis , Aterosclerose/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Neointima/diagnóstico por imagem , Intervenção Coronária Percutânea , Idoso , Materiais Biocompatíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Everolimo/administração & dosagem , Feminino , Humanos , Imunossupressores/administração & dosagem , Masculino , Pessoa de Meia-Idade , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Tomografia de Coerência Óptica , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA