Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Oral Investig ; 24(11): 3863-3870, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32170546

RESUMO

OBJECTIVES: To obtain radicular measurements of two separate mesiobuccal (MB) root canals in maxillary first molars using micro-computed tomography (µCT) with customized software. MATERIALS AND METHODS: Human maxillary first molar MB roots (N = 36) with two separate canals (MB1, MB2) and apical foramina were scanned by µCT and analyzed with Kappa2 software to reconstruct three-dimensional (3D) surface models of roots and canals. These models were sectioned at 0.1 mm intervals perpendicular to the central axis of each canal. Canal widths, 3D curvatures, and surrounding dentine thicknesses were measured concurrently on each section. Dentine thicknesses were analyzed statistically for differences between each direction and the different levels of both canals. RESULTS: Dentine walls around MB1 were thicker than MB2 (p < 0.05). Thinnest dentine was most often located at disto-inside direction in both canals. Canal widths were significantly smaller in MB2 than MB1 (p < 0.01). Apical constrictions were smaller (p < 0.05) and further (p < 0.05) from the apex in MB2 than MB1. Canal curvatures were greatest in the apical third of both canals (p < 0.001), and they were greater in MB2 than MB1 (p < 0.05). CONCLUSIONS: MB2 canals had shorter lengths, smaller widths, and more severe curvatures and were surrounded by thinner dentine walls. In MB2, apical constrictions were between 1 and 2 mm from the apex, compared to about 1 mm for MB1. CLINICAL RELEVANCE: These detailed measurements and in-depth 3D analyses of maxillary first molar MB roots with two separate canals and apical foramina provide morphologic references for root canal therapy.


Assuntos
Cavidade Pulpar , Maxila , Cavidade Pulpar/diagnóstico por imagem , Humanos , Maxila/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Microtomografia por Raio-X
2.
Odontology ; 108(2): 194-201, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31512103

RESUMO

The purpose of this study is to assess the effect of autoclave sterilization on the cyclic fatigue and torsional fracture resistance of ProTaper Universal (PTU), K3XF, HyFlex EDM (EDM), and TF adaptive (TFA). Sixty instruments from each file type were divided into two categories for cyclic fatigue group (CGr) and torsional fracture group (TGr). CGr and TGr were divided into three subgroups, respectively, consisting of ten instruments from each file type. Cyclic fatigue fracture test was performed using artificial canal made of stainless steel, and the mean number of cycles to failure (NCF) were determined. CGr1, the files were tested to establish baseline for NCF; CGr2, the files were tested cyclic fatigue after 10 cycles of autoclave; CGr3, instruments were autoclaved after being cycled to 25, 50, and 75% of corresponding NCF determined in CGr1, followed by cyclic fatigue test. The torsional fracture test was performed without autoclave (TGr1), after 3-cycle autoclave (TGr2), and 7-cycle autoclave (TGr3), respectively, which evaluated maximum torque and angular deflection. NCF, maximum torque and angular deflection were compared using one-way ANOVA with Bonferroni test. Two-way ANOVA was performed to determine the interaction between 'autoclave treatment' and 'type of NiTi file'. EDM showed highest NCF within the same autoclave treatment. TFA presented the lowest maximum torque and the highest angular deflection, and PTU presented the lowest angular deflection. Within the same NiTi file systems, most of NCF, maximum torque and angular deflection of tested files were not significantly influenced by autoclave condition.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular , Ligas Dentárias , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Esterilização , Estresse Mecânico , Titânio
3.
Int J Mol Sci ; 21(1)2019 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-31861863

RESUMO

Human ß defensin-3-C15, an epithelium-derived cationic peptide that has antibacterial/antifungal and immuno-regulatory properties, is getting attention as potential therapeutic agent in endodontics. This study aimed to investigate if synthetic human ß defensin-3-C15 (HBD3-C15) peptides could inhibit inflammatory responses in human dental pulp cells (hDPCs), which had been induced by gram-positive endodontic pathogen. hDPC explant cultures were stimulated with Streptococcus gordonii lipoprotein extracts for 24 h to induce expression of pro-inflammatory mediators. The cells were then treated with either HBD3-C15 (50 µg/mL) or calcium hydroxide (CH, 100 µg/mL) as control for seven days, to assess their anti-inflammatory effects. Quantitative RT-PCR analyses and multiplex assays showed that S. gordonii lipoprotein induced the inflammatory reaction in hDPCs. There was a significant reduction of IL-8 and MCP-1 within 24 h of treatment with either CH or HBD3-C15 (p < 0.05), which was sustained over 1 week of treatment. Alleviation of inflammation in both medications was related to COX-2 expression and PGE2 secretion (p < 0.05), rather than TLR2 changes (p > 0.05). These findings demonstrate comparable effects of CH and HDB3-C15 as therapeutic agents for inflamed hDPCs.


Assuntos
Anti-Inflamatórios/farmacologia , Lipoproteínas/imunologia , Infecções Estreptocócicas/imunologia , Streptococcus gordonii/imunologia , beta-Defensinas/farmacologia , Anti-Inflamatórios/síntese química , Células Cultivadas , Polpa Dentária/citologia , Polpa Dentária/efeitos dos fármacos , Polpa Dentária/imunologia , Humanos , Inflamação/tratamento farmacológico , Inflamação/etiologia , Inflamação/imunologia , Modelos Moleculares , Infecções Estreptocócicas/complicações , Infecções Estreptocócicas/tratamento farmacológico , beta-Defensinas/síntese química
4.
Lasers Med Sci ; 33(6): 1237-1244, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29455306

RESUMO

The purpose of this study was to compare dentinal tubule sealing effects of a 532-nm diode-pumped solid-state (DPSS) laser, gallic acid/Fe3+ complex, and three commercially available dentin desensitizers. Human premolars (n = 44) extracted for orthodontics had standardized cervical cavities prepared, etched (37% phosphoric acid) and randomly assigned to either a control (n = 4), or one of five treatment groups (n = 8/group). Desensitizing treatments were either a 532-nm DPSS laser, gallic acid/Fe3+ complex, oxalate-based Super Seal™ (SS), DIO™ Enamel Coating Pen Pro Tooth (Dio), or adhesive-type Hybrid Coat™ (HC). Dentinal fluid flow (DFF) was monitored continuously in real time during the application of each desensitizing agent, by using a nanoliter-scaled fluid flow-measuring device. Following treatment, morphological changes on dentinal surfaces and within tubules were observed by scanning electron microscopy (SEM). DFF rates were significantly reduced after treatment in all experimental groups (P < 0.05), except SS (P > 0.05). The gallic acid/Fe3+ complex reduced DFF rates the most, and significantly (P < 0.05) more than the three commercial dentin desensitizers. There were no significant differences in DFF reduction rates between the gallic acid/Fe3+ complex and the DPSS laser groups (P > 0.05). There were no significant differences in DFF reduction rates among the three commercial dentin desensitizers (P > 0.05). SEM examination of treated dentin showed that the degree of occlusion of dentinal tubules correlated closely with the corresponding reduction in DFF rates. The gallic acid/Fe3+ complex and 532-nm DPSS laser were superior to other desensitizing methods in occluding dentinal tubules and reducing DFF rates.


Assuntos
Dessensibilizantes Dentinários/uso terapêutico , Sensibilidade da Dentina/tratamento farmacológico , Ácido Gálico/química , Ferro/química , Lasers de Estado Sólido/uso terapêutico , Dentina/efeitos dos fármacos , Dentina/ultraestrutura , Dessensibilizantes Dentinários/farmacologia , Líquido Dentinal/efeitos dos fármacos , Líquido Dentinal/efeitos da radiação , Humanos
5.
Acta Odontol Scand ; 74(4): 298-306, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26807656

RESUMO

OBJECTIVE: The aim of this study was to evaluate the combined effects of mineral trioxide aggregate (MTA) and human placental extract (HPE) on cell growth, differentiation and in vitro angiogenesis of human dental pulp cells (HDPCs) and to identify underlying signal transduction mechanisms. In vivo dental pulp responses in rats for a pulp-capping agent were examined. MATERIALS AND METHODS: MTS assay. ALP activity test, alizarin red S staining and RT-PCR for marker genes were carried out to evaluate cell growth and differentiation. HUVEC migration, mRNA expression and capillary tube formation were measured to evaluate angiogenesis. Signal transduction was analysed using Western blotting and confocal microscopy. The pulps of rat maxillary first molars were exposed and capped with either MTA or MTA plus HPE. Histologic observation and scoring were performed. RESULTS: Compared to treatment of HDPCs with either HPE or MTA alone, the combination of HPE and MTA increased cell growth, ALP activity, mineralized nodules and expression of marker mRNAs. Combination HPE and MTA increased migration, capillary tube formation and angiogenic gene expression compared with MTA alone. Activation of Akt, mammalian target of rapamycin (mTOR), p38, JNK and ERK MAPK, Akt, and NF-κB were significantly increased by combining HPE and MTA compared with MTA alone. Pulp capping with MTA plus HPE in rats showed superior dentin bridge formation, odontoblastic layers and dentinal tubules and lower inflammatory cell response, compared to the MTA alone group. CONCLUSIONS: This study demonstrates for the first time that the use of MTA with HPE promotes cell growth, differentiation and angiogenesis in HDPCs, which were associated with mTOR, MAPK and NF-κB pathways. Direct pulp capping with HPE plus MTA showed superior results when compared with MTA alone. Thus, the combination of MTA and HPE may be useful for regenerative endodontics.


Assuntos
Compostos de Alumínio/farmacologia , Compostos de Cálcio/farmacologia , Polpa Dentária/efeitos dos fármacos , Óxidos/farmacologia , Extratos Placentários/farmacologia , Silicatos/farmacologia , Fosfatase Alcalina/efeitos dos fármacos , Compostos de Alumínio/uso terapêutico , Animais , Calcificação Fisiológica/efeitos dos fármacos , Compostos de Cálcio/uso terapêutico , Capilares/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Linhagem Celular , Movimento Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Polpa Dentária/irrigação sanguínea , Polpa Dentária/citologia , Dentina Secundária/efeitos dos fármacos , Combinação de Medicamentos , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Humanos , MAP Quinase Quinase 4/efeitos dos fármacos , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Masculino , Proteínas Quinases Ativadas por Mitógeno/efeitos dos fármacos , NF-kappa B/efeitos dos fármacos , Neovascularização Fisiológica/efeitos dos fármacos , Odontoblastos/citologia , Odontoblastos/efeitos dos fármacos , Óxidos/uso terapêutico , Extratos Placentários/uso terapêutico , Proteínas Proto-Oncogênicas c-akt/efeitos dos fármacos , Agentes de Capeamento da Polpa Dentária e Pulpectomia/uso terapêutico , Ratos , Ratos Sprague-Dawley , Transdução de Sinais/efeitos dos fármacos , Silicatos/uso terapêutico , Serina-Treonina Quinases TOR/efeitos dos fármacos , Proteínas Quinases p38 Ativadas por Mitógeno/efeitos dos fármacos
6.
Acta Odontol Scand ; 73(6): 427-32, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25385684

RESUMO

OBJECTIVE: Micro-computed tomography (MCT) with alternative image reformatting techniques shows complex and detailed root canal anatomy. This study compared two-dimensional (2D) and 3D MCT image reformatting with standard tooth clearing for studying mandibular first molar mesial root canal morphology. MATERIALS AND METHODS: Extracted human mandibular first molar mesial roots (n=31) were scanned by MCT (Skyscan 1172). 2D thin-slab minimum intensity projection (TS-MinIP) and 3D volume rendered images were constructed. The same teeth were then processed by clearing and staining. For each root, images obtained from clearing, 2D, 3D and combined 2D and 3D techniques were examined independently by four endodontists and categorized according to Vertucci's classification. Fine anatomical structures such as accessory canals, intercanal communications and loops were also identified. RESULTS: Agreement among the four techniques for Vertucci's classification was 45.2% (14/31). The most frequent were Vertucci's type IV and then type II, although many had complex configurations that were non-classifiable. Generally, complex canal systems were more clearly visible in MCT images than with standard clearing and staining. Fine anatomical structures such as intercanal communications, accessory canals and loops were mostly detected with a combination of 2D TS-MinIP and 3D volume-rendering MCT images. CONCLUSIONS: Canal configurations and fine anatomic structures were more clearly observed in the combined 2D and 3D MCT images than the clearing technique. The frequency of non-classifiable configurations demonstrated the complexity of mandibular first molar mesial root canal anatomy.


Assuntos
Cavidade Pulpar/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Preparo de Canal Radicular/métodos , Microtomografia por Raio-X/métodos , Adulto , Anatomia Transversal/métodos , Corantes , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Raiz Dentária/diagnóstico por imagem
7.
Materials (Basel) ; 17(10)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38793436

RESUMO

This study aimed to compare the nanoleakage of retrograde fillings with premixed calcium silicate-based putty and mineral trioxide aggregate (MTA), using two different techniques (traditional and Lid). Sixty-four extracted human teeth were decoronated, then root canals and ends were instrumented for retrograde filling and divided into four groups according to the retrograde filling technique: the traditional and the Lid technique. Each group (n = 15) was filled with Ceraseal + Well-Root putty, Well-Root putty, Ceraseal + ProRoot MTA, and ProRoot MTA. The nanoleakage was evaluated using the Nanoflow device (IB Systems) on days 1, 3, 7, 15 and 30. Data were collected twice per second at the nanoscale (nL/s) and calculated after archiving the stabilization of fluid flow. The Kruskal-Wallis and Mann-Whitney U-tests were used for statistical analysis. All groups showed enhanced sealing ability over time. Regardless of filling materials, the Well-Root putty, Ceraseal+Well-Root putty, and Ceraseal+ProRoot MTA groups indicated less nanoleakage than the ProRoot MTA group in the first week of evaluation (p < 0.05). Although all groups did not show significant differences after 2 weeks, the Ceraseal+ProRoot MTA group leaked less than ProRoot MTA on Days 3 and 7 (p < 0.05). The scanning electron microscopic examined good adaptation to the cavity wall, which was similar to nanoleakage results. Premixed calcium silicate-based putty retrograde filling material alone and using the "lid technique" were shown to be faster and less prone to nanoleakage when compared to MTA.

8.
Clin Oral Investig ; 17(6): 1541-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23053704

RESUMO

OBJECTIVES: Detailed information of complex anatomical configuration of mesiobuccal (MB) root is essential for successful endodontic treatment in maxillary first molars. The aims of this study were to investigate the configuration types present in multiple-canalled MB roots of maxillary first molars using micro-computed tomography (µCT) and to evaluate whether further modification to current configuration classifications are needed for in-depth morphology study of MB root canal system. MATERIALS AND METHODS: One hundred and fifty-four extracted human maxillary first molar MB roots were scanned by µCT (Skyscan) and their canals were reconstructed by 3D modeling software. Root canal configurations were categorized according to the classifications proposed by Weine and Vertucci. Canal configurations that did not fit into both classifications were categorized as non-classifiable. RESULTS: One hundred and thirteen (73.4 %) MB roots had multiple canals. The most predominant canal configuration was Weine type III (two orifices and two foramens). Thirty-three (29.2 %) and 20 (17.7 %) MB roots had non-classifiable configuration types that could not be classified by the Weine and Vertucci classification, respectively. Three configurations (types 1-3, 2-3-2-3-2, and 2-3-4-3-2) were first reported in maxillary first molar MB roots. CONCLUSIONS: The present µCT study provided an in-depth analysis of canal configurations of the MB roots of maxillary first molar and suggests that additional modification of current configuration classifications may be needed to more accurately reflect the morphology configurations of MB roots. CLINICAL RELEVANCE: Clinicians should consider the complex canal configurations of the maxillary first molar MB roots during surgical or nonsurgical endodontic procedures.


Assuntos
Cavidade Pulpar/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Adulto , Idoso , Variação Anatômica , Classificação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Maxila , Pessoa de Meia-Idade , Ápice Dentário/diagnóstico por imagem
9.
J Dent Sci ; 17(4): 1586-1594, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36299316

RESUMO

Background/purpose: Several brands of calcium silicate-based cements (CSBCs) are currently marketed. Here we compared physicochemical and biological properties of new products Ortho MTA (BioMTA), Retro MTA (BioMTA), and EZ-Seal (Ezekiel) to widely used ProRoot MTA (Dentsply Tulsa). Materials and methods: CSBCs were analyzed by X-ray diffractometry and examined by scanning electron microscopy. Elemental composition was determined by energy dispersive spectroscopy. Particle size was measured by particle size analyzer. Human stem cells from apical papilla (SCAPs) were incubated with eluates from CSBCs. Survival of SCAP cells was evaluated with MTT assay. The Alizarin red S stain was used to identify calcified nodules formed in SCAP cultures. The effects of CSBC eluates on SCAP proliferation and migration were examined using an in-vitro scratch "wound-healing" assay. Results: All CSBC specimens showed similar X-ray diffraction patterns. The average particle size of EZ-Seal was smaller than ProRoot MTA, Ortho MTA, and Retro MTA (P < 0.001). The least cytotoxicity of eluates was found for EZ-Seal. In the Alizarin red S staining test, calcified nodules were observed in cultures with ProRoot MTA, Ortho MTA, and Retro MTA, however, no calcified nodules were observed in cultures with EZ-Seal. SCAP proliferation and migration capacity in presence of EZ-Seal was higher than with ProRoot MTA, Ortho MTA, and Retro MTA (P < 0.001). Conclusion: EZ-Seal has a smaller average particle size and a better cytocompatibility than all other examined CSBCs.

10.
Biomater Res ; 25(1): 39, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34819173

RESUMO

BACKGROUND: The addition of bioactive glass (BG), a highly bioactive material with remineralization potential, might improve the drawback of weakening property of mineral trioxide aggregates (MTA) when it encounters with body fluid. This study aims to evaluate the effect of BG addition on physical properties of MTA. METHODS: ProRoot (MTA), and MTA with various concentrations of BG (1, 2, 5 and 10% BG/MTA) were prepared. Simulated body fluid (SBF) was used to investigate the effect of the storage solution on dentin remineralization. Prepared specimens were examined as following; the push-out bond strength to dentin, compressive strength, setting time solubility and X-ray diffraction (XRD) analysis. RESULTS: The 2% BG/MTA showed higher push-out bond strengths than control group after 7 days of SBF storage. The 2% BG/MTA exhibited the highest compressive strength. Setting times were reduced in the 1 and 2% BG/MTA groups, and solubility of all experimental groups were clinically acceptable. In all groups, precipitates were observed in dentinal tubules via SEM. XRD showed the increased hydroxyapatite peaks in the 2, 5 and 10% BG/MTA groups. CONCLUSION: It was verified that the BG-added MTA increased dentin push-out bond strength and compressive strength under SBF storage. The addition of BG did not negatively affect the MTA maturation reaction; it increased the amount of hydroxyapatite during SBF maturation.

11.
J Endod ; 47(8): 1285-1293.e1, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34044040

RESUMO

INTRODUCTION: This study aimed to investigate microbiota and the histopathology of infected immature teeth microenvironments after disinfection with calcium hydroxide, triple antibiotic paste, and a synthetic antimicrobial peptide (synthetic human beta-defensin-3-C15) for regenerative endodontic procedures (REPs). The null hypothesis was that there is no difference among intracanal medications on disinfection in REPs. METHODS: Pulp necrosis and periapical lesions were induced in immature beagle dog premolars. Block randomized teeth were uninfected (negative control, n = 6), left infected (positive control, n = 6), or medicated with a disinfectant (n = 6/group). After disinfection (2 weeks), teeth were reaccessed, irrigated with 17% EDTA, blood clot induced, sealed with ProRoot MTA (Dentsply Tulsa Dental, Tulsa, OK), and restored with resin-modified glass ionomer. Animals were monitored radiographically and euthanized (12 weeks) for histopathologic and metagenomic analyses. RESULTS: REP-treated roots showed radiographic repair of periapical radiolucency (67.65%, 23/34), continued root development (73.53%, 25/34), and apical closure (70.59%, 24/34) regardless of the disinfectant used (P > .05). Canal microenvironments histologically devoid of bacteria contained new mineralized and pulp-like tissues in characteristic patterns that varied by disinfectant. Next-generation sequencing (16S ribosomal RNA) identified Firmicutes, Proteobacteria, Actinobacteria, and Bacteroidetes as dominant phyla of microbiota in immature teeth. Infection-induced teeth showed changes in diversity and richness of microbiota from negative controls. Compared with positive controls, all treated teeth exhibited depleted operational taxonomic units, with lower phylogenic diversity from synthetic human beta-defensin-3-C15-treated teeth. CONCLUSIONS: There were no differences among the medicaments investigated in radiologic treatment outcomes, but disinfectants in REPs showed altered microbiota from normal and diseased immature teeth with different histologic patterns of regeneration.


Assuntos
Microbiota , Periodontite Periapical , Endodontia Regenerativa , Animais , Necrose da Polpa Dentária/terapia , Cães , Periodontite Periapical/terapia , Tratamento do Canal Radicular
12.
Oper Dent ; 35(3): 330-6, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20533634

RESUMO

This study evaluated the effects of blood contamination and decontamination methods during different steps of bonding procedures on the microtensile bond strength of two-step self-etch adhesives to dentin. Sixty extracted human molars were ground flat to expose occlusal dentin. The 60 molars were randomly assigned to three groups, each treated with a different two-step self-etch adhesive: Clearfil SE Bond, AdheSE and Tyrian SPE. In turn, these groups were subdivided into five subgroups (n = 20), each treated using different experimental conditions as follows: control group-no contamination; contamination group 1-CG1: primer application/ contamination/primer re-application; contamination group 2-CG2: primer application/contamination/wash/dry/primer re-application; contamination group 3-CG3: primer application/adhesive application/light curing/contamination/ adhesive re-application/light curing; contamina- tion group 4-CG4: primer application/adhesive application/light curing/contamination/wash/ dry/adhesive re-application/light curing. Composite buildup was performed using Z250. After 24 hours of storage in distilled water at 37 degrees C, the bonded specimens were trimmed to an hourglass shape and serially sectioned into slabs with 0.6 mm2 cross-sectional areas. Microtensile bond strengths (MTBS) were assessed for each specimen using a universal testing machine. The data were analyzed by two-way ANOVA followed by a post hoc LSD test. SEM evaluations of the fracture modes were also performed. The contaminated specimens showed lower bond strengths than specimens in the control group (p < 0.05), with the exception of CG1 in the Clearfil SE group and CG2 and CG3 in the Tyrian SPE group. Among the three self-etch adhesives, the Tyrian SPE group exhibited a significantly lower average MTBS compared to the Clearfil SE Bond and AdheSE (p < 0.05) groups. Based on the results of the current study, it was found that blood contamination reduced the MTBS of all three self-etch adhesives to dentin, and water-rinsing was unable to overcome the effects of blood contamination.


Assuntos
Sangue , Descontaminação/métodos , Colagem Dentária , Adesivos Dentinários/química , Dentina/ultraestrutura , Resinas Acrílicas/química , Resinas Compostas/química , Materiais Dentários/química , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Resistência à Tração , Fatores de Tempo , Água/química
13.
Bioinorg Chem Appl ; 2020: 8892561, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33029113

RESUMO

The objective of root canal obturation is to achieve a fluid-tight seal. Recently, GuttaFlow bioseal (GB), a root canal sealer composed of polydimethylsiloxane, gutta-percha particles, and bioactive glass ceramics, has been developed, to enhance the sealing ability of root canal filling material. The objective of this study was to assess the sealing ability of GB using a subnanoliter-scaled fluid-flow measuring device and to compare with that of AH Plus (AH). The fluid flow in root canal-filled teeth using either gutta-percha cone (GP) with AH (GAR; n = 10) or GP with GB (GBR; n = 10) and in GP inserted in AH blocks (GA; n = 10) or GP inserted in GB blocks (GB; n = 10) was measured. In addition, fluid flow in sealer blocks of AH (A; n = 10) and GB (B; n = 10), which served as negative controls, was measured. Root canal-filled teeth using GP without any sealer (GR) acted as positive controls (n = 10). The leakage was obtained by calculating the volume of moved water by time (s), after stabilization of the fluid flow was achieved. Statistical analysis was performed using the Kruskal-Wallis test and Mann-Whitney U-test with Bonferroni correction. A p value less than 0.00238 (0.05/21) was considered significantly different. The mean leakages (nL/s) in the groups are as follows: GAR, 0.0958 ± 0.0543; GBR, 0.0223 ± 0.0246; GA, 0.0644 ± 0.0803; GB, 0.0267 ± 0.0182; A, 0.0055 ± 0.0057; B, 0.0052 ± 0.005; and GR, 0.2892 ± 0.3018. The mean leakage in the GBR group was lower than that in the GAR group (p = 0.001), while the mean leakages in the GA and GB groups were not significantly different. GuttaFlow bioseal can be useful in single-cone obturation technique.

14.
J Clin Med ; 9(1)2020 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-31963371

RESUMO

Various three-dimensional (3D) culture methods have been introduced to overcome the limitations of in vitro culture and mimic in vivo conditions. This study aimed to evaluate two microsphere-forming culture methods and a monolayer culture method. We evaluated cell morphology, viability, osteo-, adipo-, and chondrogenic differentiation potential of dental pulp stem cells (DPSCs) cultured in 3D culture plates: ultra-low attachment (ULA) and U-bottomed StemFit 3D (SF) plates, and a two-dimensional (2D) monolayer plate. RNA sequencing (RNA-seq) revealed differentially expressed gene (DEG) profiles of the DPSCs. In contrast to an increasing pattern in the 2D group, cell viability in 3D groups (ULA and SF) showed a decreasing pattern; however, high multilineage differentiation was observed in both the 3D groups. RNA-seq showed significantly overexpressed gene ontology categories including angiogenesis, cell migration, differentiation, and proliferation in the 3D groups. Hierarchical clustering analysis revealed a similar DEG regulation pattern between the 3D groups; however, a comparatively different DEG was observed between the 2D and 3D groups. Taken together, this study shows that DPSCs cultured in microsphere-forming plates present superior multilineage differentiation capacities and demonstrate higher DEG expression in regeneration-related gene categories compared to that in DPSCs cultured in a conventional monolayer plate.

15.
J Investig Clin Dent ; 10(3): e12409, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30848100

RESUMO

AIM: The aim of the present study was to evaluate the resistance to cyclic fatigue of heat-treated single files used in proper or in reciprocating optimum torque reverse motions. METHODS: Ninety-six HyFlex electrical discharge machining (EDM), Reciproc R25 (Rec), WaveOne Primary (WO), and WaveOne Gold (WOG) Primary were used. Resistance to cyclic fatigue was determined by recording time to fracture in a stainless steel artificial canal. Differential scanning calorimetric analysis was performed. Data were analyzed by two-way analysis of variance and Bonferroni post-hoc tests at 0.05. RESULTS: In both movements, HyFlex EDM showed higher time to fracture than other files (P < 0.0001). Rec showed higher time to fracture than WO (P < 0.0001), while WOG showed higher cyclic fatigue resistance than Rec and WO with both movements (P < 0.005). CONCLUSIONS: Reciprocating optimum torque reverse motion improved significantly cyclic fatigue resistance of gold and controlled memory wire single files.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular , Fenômenos Biomecânicos , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Titânio , Torque
16.
Biomed Res Int ; 2019: 6368958, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31828110

RESUMO

Nickel-titanium (NiTi) rotary files have enabled efficient root canal preparations that maintain the canal center with fewer aberrations compared to hand files. However, NiTi rotary files are susceptible to fracture, which can thereby compromise root canal treatment. Therefore, NiTi files have been developed to enhance fracture resistance by modifying design and thermal treatment. The objective of this study was to compare the torsional fatigue resistance and bending resistance of NiTi files manufactured from different alloys and treatments. ProTaper NEXT X2 (PTN; M-wire), V taper 2H (V2H; controlled memory wire), NRT (heat-treated), and One Shape (OS; conventional alloy) instruments of tip size #25 were compared. Torsional fatigue was evaluated by embedding the 3 mm tip of each instrument (N = 10/brand) in resin and the repetitive application of torsional stress (300 rpm, 1.0 N·cm) by an endodontic motor with autostop when the file fractured. The number of loading cycles to fracture was recorded and analyzed by Kruskal-Wallis and Mann-Whitney U tests with Bonferroni's correction. Bending resistance of the instruments was tested using a cantilever bending test to the 3 mm point from the tip (N = 10/brand). The stress was measured when deflection of 3 mm was subjected and statistically analyzed with a one-way analysis of variance and Tukey's honest significance difference test (α = 0.05). V2H withstood the highest number of load applications during torsional fatigue testing (p < 0.05), followed by NRT, PTN, and OS, where the differences between NRT and PTN (p=0.035) and between PTN and OS (p=0.143) were not statistically significant. V2H showed the lowest bending stiffness, followed by NRT, PTN, and OS (p < 0.001). Thermal treatment of NiTi wire resulted in improved mechanical properties, and controlled memory wire provided improved flexibility and torsional fatigue resistance.


Assuntos
Ligas/química , Ligas Dentárias/química , Teste de Materiais , Níquel/química , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular
17.
Bioinorg Chem Appl ; 2018: 2784632, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29487618

RESUMO

Chemical composition and porosity characteristics of calcium silicate-based endodontic cements are important determinants of their clinical performance. Therefore, the aim of this study was to investigate the chemical composition and porosity characteristics of various calcium silicate-based endodontic cements: MTA-angelus, Bioaggregate, Biodentine, Micromega MTA, Ortho MTA, and ProRoot MTA. The specific surface area, pore volume, and pore diameter were measured by the porosimetry analysis of N2 adsorption/desorption isotherms. Chemical composition and powder analysis by scanning electron microscope (SEM) and energy dispersive spectroscopy (EDS) were also carried out on these endodontic cements. Biodentine and MTA-angelus showed the smallest pore volume and pore diameter, respectively. Specific surface area was the largest in MTA-angelus. SEM and EDS analysis showed that Bioaggregate and Biodentine contained homogenous, round and small particles, which did not contain bismuth oxide.

18.
Restor Dent Endod ; 43(2): e25, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29765904

RESUMO

OBJECTIVES: To evaluate the mechanical properties and metallurgical characteristics of the M3 Rotary and M3 Pro Gold files (United Dental). MATERIALS AND METHODS: One hundred and sixty new M3 Rotary and M3 Pro Gold files (sizes 20/0.04 and 25/0.04) were used. Torque and angle of rotation at failure (n = 20) were measured according to ISO 3630-1. Cyclic fatigue resistance was tested by measuring the number of cycles to failure in an artificial stainless steel canal (60° angle of curvature and a 5-mm radius). The metallurgical characteristics were investigated by differential scanning calorimetry. Data were analyzed using analysis of variance and the Student-Newman-Keuls test. RESULTS: Comparing the same size of the 2 different instruments, cyclic fatigue resistance was significantly higher in the M3 Pro Gold files than in the M3 Rotary files (p < 0.001). No significant difference was observed between the files in the maximum torque load, while a significantly higher angular rotation to fracture was observed for M3 Pro Gold (p < 0.05). In the DSC analysis, the M3 Pro Gold files showed one prominent peak on the heating curve and 2 prominent peaks on the cooling curve. In contrast, the M3 Rotary files showed 1 small peak on the heating curve and 1 small peak on the cooling curve. CONCLUSIONS: The M3 Pro Gold files showed greater flexibility and angular rotation than the M3 Rotary files, without decrement of their torque resistance. The superior flexibility of M3 Pro Gold files can be attributed to their martensite phase.

19.
Materials (Basel) ; 11(4)2018 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-29641475

RESUMO

This study evaluated the sealing ability of gutta-percha (GP) with a calcium silicate-based sealer and a novel calcium zirconate containing calcium silicate cement (ZC). The root canals of the extracted premolars were prepared, which were then randomly allocated to three experimental groups (12 root canals per group) for obturation by continuous wave of condensation with the GP and AH 26 sealer (CW); obturation using a single GP with a calcium silicate-based EndoSequence BC sealer (SC); or obturation with ZC. The roots were inserted into sterile Eppendorf tubes, which were inoculated coronally with Porphyromonas gingivalis. The amount of endotoxin leakage into the apical reservoirs were measured using the Limulus Amebocyte Lysate (LAL) assay over 21 days, with comparisons made using one-way ANOVA and Scheffe's tests (α = 0.05). After 21 days, 75% of the canals that had been obturated by SC, 50% of those obturated by CW and 42% of those obturated by ZC showed endotoxin leakage. The amount of leakage was higher in the SC canals than in the CW (p = 0.031) or ZC (p = 0.03) canals, although there was no significant difference in the amount of leakage for CW and ZC (p > 0.05). X-ray diffraction revealed the presence of tricalcium silicate (Ca3SiO5) and calcium zirconate (CaZrO3) in the synthesized ZC. Scanning electron microscopy revealed mineralized precipitates on the dentin of canals obturated by ZC. The novel calcium zirconate silicate cement appears to promote biomineralization and seal root canals at least as effectively as the conventional sealer.

20.
Biomed Res Int ; 2017: 4528601, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29318149

RESUMO

The aim of this study was to investigate the effect of thermomechanical treatment on mechanical and metallurgical properties of nickel-titanium (NiTi) rotary instruments. Eight kinds of NiTi rotary instruments with sizes of ISO #25 were selected: ProFile, K3, and One Shape for the conventional alloy; ProTaper NEXT, Reciproc, and WaveOne for the M-wire alloy; HyFlex CM for the controlled memory- (CM-) wire; and TF for the R-phase alloy. Torsional fracture and cyclic fatigue fracture tests were performed. Products underwent a differential scanning calorimetry (DSC) analysis. The CM-wire and R-phase groups had the lowest elastic modulus, followed by the M-wire group. The maximum torque of the M-wire instrument was comparable to that of a conventional instrument, while those of the CM-wire and R-phase instruments were lower. The angular displacement at failure (ADF) for the CM-wire and R-phase instruments was higher than that of conventional instruments, and ADF of the M-wire instruments was lower. The cyclic fatigue resistance of the thermomechanically treated NiTi instruments was higher. DSC plots revealed that NiTi instruments made with the conventional alloy were primarily composed of austenite at room temperature; stable martensite and R-phase were found in thermomechanically treated instruments.


Assuntos
Ligas/química , Instrumentos Odontológicos , Humanos , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA