Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Zhongguo Ying Yong Sheng Li Xue Za Zhi ; 37(1): 104-112, 2021 Jan.
Artigo em Zh | MEDLINE | ID: mdl-34672470

RESUMO

Objective: We tried to implant the ultra-fast polymer optical fiber chemical oxygen sensor (POFCOS) into arterial blood vessel,connect with photoelectric conversion measurement system to record the continuous dynamic rapid changes of arterial PO2(PaO2) in whole living animals. It should be the experimental evidence for the new theory of holistic integrative physiology and medicine(HIPM) forexplain the mechanism of respiratory control and regulation in whole circusof respiration-circulation-metabolism. Methods: ①Fabrication of ultrafast POFCOS, calibration and its measuring system: The distal part of 2 m optical fiber was heated and pulled until it became a tapered tip. After cleaning and drying, the tip of 1 mm tapered optical fiber was dip-coated into the luminophore doped polymer solution, then was slowly pumped out while solvent was quickly evaporated to form an oxygen sensing tip, which was dried at room temperature for 24 hours. ②Animal experiments: Under general anesthesia and intubation, goatwas mechanically ventilated with 40%~60% oxygen. We exposed both right and left carotid arteries and the left femoral artery by skin cutting, and inserted the POFCOS directly into the arteries via indwelling catheter. The end of POFCOS were connected to the personal computer through optical fiber, excitation and detection Y-type optical fiber coupler through photoelectric conversion, so as we can realize the continuous dynamic response of living goat carotid PaO2 under mechanical ventilation. We mainly analyzed the intra-breath wave-form alternate increase and decrease of PaO2 and their time delay between lung and carotid arteries.We completes breathing control whole loop to explain the mechanism of mutual breathing and the switching of inspiration and exhalation. Results: The POFCOS has a very fast T90 response time was set 100 ms for liquid. When the heart rate of 40%~60% oxygen mechanical ventilated living goat was ~110 bpm, the PaO2 of left and right carotid artery showed a same wave-sizeup and down following with the inspiration and expiration of ventilator, with a range of up to 15 mmHg. There weresignificant noises of PaO2 change recorded in the left femoral artery. The lung-carotid artery time delay is 1.5~1.7 s after inhalation and exhalation, PaO2 at both left and right carotid arteries starts toincrease and decrease. After two-three heartbeats after the start of lung ventilation, thealternate up-down wave-form information of the arterialized pulmonary vein blood after pulmonary capillaries waspumpedby left ventricle to the position of peripheral chemoreceptors,thus realizing the whole cycle of inhalation and exhalation. It alternately interrupted inhalation, i.e. switching inhalation to exhalation, and then interrupted exhalation,i.e. switching exhalation to inhalation. Conclusion: The ultra-fast reactive implantableoxygen sensor and its measuring system can measure the physiological waveform changes of PaO2 in living animals, which can provide experimental evidence for explaining the mechanism of switching of inspiration-expiration in HIPM.


Assuntos
Polímeros , Respiração Artificial , Animais , Fibras Ópticas , Oxigênio , Pressão Parcial
2.
Mater Sci Eng C Mater Biol Appl ; 76: 1216-1223, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28482488

RESUMO

This paper demonstrates Ca-P-rich bio-ceramic and hydroxyapatite (HA) coatings formed directly from the solution of calcium acetate (CA) and sodium dihydrogen phosphate (SDP) on α-Ti-alloy substrates by Growing Integration Layer (GIL) technology under DC power supply. The composition of the α-Ti-alloy was Ti7Cu5Sn. The GIL coated films formed in 30min time with different voltages applied had porous and rough ceramic surfaces. They consisted mostly of various oxides like rutile, anatase, and calcium phosphates (including hydroxyapatite) that reduce corrosion rate and increase biocompatibility. An important feature was the reduction of Cu at the surfaces of the alloys. Furthermore, along with the applied voltage, the content of HA, the size of micro-pores, and hardness all increased, while the number of micro-pores in the ceramic membrane got reduced. The potential, current and resistance of corrosion were identified by potentiodynamic (PD) polarization and electrochemical impedance spectroscopy (EIS). The higher applied voltage improved the surface quality, HA formation rate, and the anti-corrosion behavior. Consequently, the samples - prepared at 350V and surface current density of 3A/cm2 - possessed the most compact HA films, and also had the best corrosion resistance - in 0.9wt% NaCl solution at 37±1°C.


Assuntos
Cerâmica , Ligas , Fosfatos de Cálcio , Corrosão , Durapatita , Teste de Materiais , Propriedades de Superfície , Titânio
3.
Curr Neurovasc Res ; 14(3): 274-289, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28721809

RESUMO

BACKGROUND: Promoting angiogenesis provides a possible therapeutic approach in treating spinal cord injury (SCI). Vascular endothelial growth factor (VEGF) is a pro-angiogenic substance that is involved in endothelial cell (EC) proliferation, migration, and survival. Exogenous administration of VEGF to the lesion epicenter of the spinal cord has been recently revealed as a potential method for promoting the blood vessel sprouting. METHODS: Spinal cord hemisection in a rat model was established and angiogenesis was studied through implant of an acellular spinal cord scaffold (ASCS) with sustained delivery of VEGF<sub>165</sub>. The poly (lactic-co-glycolic acid) (PLGA) nanoparticles (NPs) encapsulating VEGF<sub>165</sub> were fabricated on basis of an emulsion and solvent evaporation method and conjugated to ASCS by a Genipin (GP) crosslinking technology. The resultant scaffolds were marked as V-ASCS. VEGF<sub>165</sub> entrapment efficiency (EE) and released kinetics were determined by an ultraviolet absorption measurement. Angiogenesis and vascular remodeling were observed via a high-resolution micro-CT and analyzed quantitatively by vascular morphometric parameters. Spinal cord histology and Basso, Beattie, and Bresnahan (BBB) locomotor rating scale were further studied. RESULTS: VEGF<sub>165</sub> was entrapped with high efficiency (90.8±3.1) %. In vitro VEGF<sub>165</sub> release kinetics study showed an initial burst of 1.966 µg mg NPs-1 and 1.045µg mg V-ASCS-1 respectively in the first 24 hours. In the phase of sustained release, approximately 0.040µg mg NPs-1 and 0.022µg mg V-ASCS-1 per day was on-going until 720h. In the rat spinal cord hemisection model, implant of V-ASCS at the injured site showed a promotion of angiogenesis and vascular remodeling following SCI. A better outcome can be confirmed histologically. However, functional improvement is limited in the animal model. CONCLUSION: The results indicate that progress of vascular reconstruction is accelerated in the V-ASCS implanted SCI rats.


Assuntos
Sistemas de Liberação de Medicamentos , Lateralidade Funcional/fisiologia , Traumatismos da Medula Espinal/tratamento farmacológico , Fator A de Crescimento do Endotélio Vascular/administração & dosagem , Remodelação Vascular/efeitos dos fármacos , Animais , Modelos Animais de Doenças , Imageamento Tridimensional , Masculino , Atividade Motora/fisiologia , Poliésteres/uso terapêutico , Ratos , Ratos Sprague-Dawley , Recuperação de Função Fisiológica/efeitos dos fármacos , Traumatismos da Medula Espinal/diagnóstico por imagem , Traumatismos da Medula Espinal/patologia , Tomografia Computadorizada por Raios X
4.
Electrophoresis ; 28(10): 1579-86, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17447239

RESUMO

Microelectrodes have been adopted in electrochemical detection for CE or microchip CE in recent years. In this paper, the use of nanoelectrodes (with tip diameter of 100-300 nm) as the electrochemical detector in microchip CE is firstly reported. The experimental results indicated that both the sensitivity and resolution of microchip CE with the carbon fiber nanoelectrode (CFNE) amperometric detection have been improved markedly comparing with the traditional microelectrodes. The detection limit of dopamine (S/N = 3) is 5.9x10(-8) M, which is one or two orders of magnitude lower than that reported so far, and the resolution of dopamine (DA) and isoprenaline (IP) has also improved from 0.6 (using 7 mum carbon fiber microelectrodes, CFME) to 1.0. We assembled a novel and easily operated microchip CE system with end-column amperometric detection, which allows the convenient and fast replacement of the passivated electrodes. Under the optimized condition, the RSDs of peak height and migration time are 1.47 and 0.31%, respectively (n = 40), indicating that the system displays excellent reproducibility. The nanoelectrode-based microchip CE system has been successfully applied to the determination of DA in cultured rat pheochromocytoma (PC12) cells, and the average content of DA in an individual PC12 cell is 0.54 +/- 0.07 fmol, which is in good agreement with that reported in the literature.


Assuntos
Dopamina/análise , Eletroforese em Microchip/instrumentação , Microeletrodos/classificação , Nanotubos de Carbono/classificação , Feocromocitoma/química , Animais , Carbono/classificação , Fibra de Carbono , Extratos Celulares , Condutometria/métodos , Dopamina/química , Eletroforese em Microchip/métodos , Microquímica/instrumentação , Miniaturização/instrumentação , Células PC12 , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA