Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Zhongguo Zhong Yao Za Zhi ; 37(20): 3056-61, 2012 Oct.
Artigo em Zh | MEDLINE | ID: mdl-23311153

RESUMO

OBJECTIVE: To study the extraction system of hirudin emulsion liquid membrane with the Poecilobdella manillensis as raw material, di-(2-ethylhexyl) phosphate (D2EHPA) as carrier, Span 80 as emulsifier, octane and D2EHPA mixed to constitute membrane solution, diluted HCl solutions as internal aqueous phase. METHOD: Using the orthogonal experiment to optimize the extraction conditions of hirudin reference substance such as membrane phase, internal aqueous phase volume ratio (MIPVR), external aqueous phase pH, internal aqueous phase pH, mobile carrier concentration and so on, and then using hirudin crude extracts to do purifying experiment, and gaining experimental samples. RESULT: The optimal conditions of hirudin extraction were as follows: MIPVR 10: 3, internal aqueous phase pH 2.6, external aqueous phase pH 3.4, the mass fraction of carrier D2EHPA 2%. In the optimal extraction conditions, when the initial concentration of hirudin was one anti-thrombin activity units (ATU) x mL(-1), ATU recovery rate of the reference substance was 83.06%. In the purifying experiment of crude extracts, ATU recovery rate was 82.99%, and the specific activity of sample was 3 289.48 the ATU x mg(-1). Discontinuous polyacrylamide gel electrophoresis and spectral scanning, the results showed that the purity and reference substance were considerable. CONCLUSION: The method of preparation hirudin was relatively simple, the purity of the experimental samples and ATU recovery were both high.


Assuntos
Hirudinas/isolamento & purificação , Sanguessugas/química , Extração em Fase Sólida/métodos , Animais , Emulsões/química , Hirudinas/análise , Membranas Artificiais , Extração em Fase Sólida/instrumentação
2.
J Mass Spectrom ; 54(2): 189-194, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30597687

RESUMO

Urinary biopterin (Bio) and neopterin (Neo) are important markers for clinical diagnosis of hyperphenylalaninemia. Herein, we developed a high-throughput analysis method based on electrospray ionization mass spectrometry (ESI-MS) with polymer tips for the rapid quantitative detection of Bio and Neo in clinical urine samples. Different polymer tips were investigated. It is found that the best detection sensitivity was achieved with hydrophobic polymer tip, ie, polyethylene tips. The high-throughput polymer tip-ESI-MS method allowed a rapid analysis speed at ~40 seconds per sample. The limits of quantification (LOQ) (S/N ≥ 10) for the detection of Bio and Neo were improved to be 5.0 ng/mL. Acceptable relative standard deviation (RSD) values for Neo and Bio were measured to be 12.2% and 13.4% for direct measurement of Bio and Neo in raw urine samples, respectively. Furthermore, Bio and Neo were directly quantified from 18 clinical urine samples by presented method. The ratios of urinary Bio-to-Neo were analyzed for diagnosis of hyperphenylalaninemia. The results demonstrated that the present polymer tip-ESI-MS method is a promising strategy for the rapid analysis of clinical samples.


Assuntos
Biopterinas/urina , Neopterina/urina , Polímeros/química , Biomarcadores/urina , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Fenilcetonúrias/diagnóstico , Solventes , Espectrometria de Massas por Ionização por Electrospray/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA