Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Prosthet Dent ; 130(6): 936.e1-936.e9, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37802736

RESUMO

STATEMENT OF PROBLEM: Selecting the sterilization method is important because sterilization can alter the surface chemistry of implant materials, including zirconia, and influence their cellular biocompatibility. Studies on the biological effects of sterilization on implant materials are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the biocompatibility of gamma-ray irradiated 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) compared with unirradiated titanium, 3Y-TZP, and pure gold. MATERIAL AND METHODS: Disk-shaped specimens each of commercially pure grade 4 titanium, 3Y-TZP, gamma-rayed 3Y-TZP, and pure gold were prepared and evaluated for osteogenic potential by using a clonal murine cell line of immature osteoblasts derived from mice (MC3T3-E1 cells). The surface topography (n=3), chemical analysis of the disks (n=3), and cell morphology cultured on these surfaces were examined using scanning electron microscopy, confocal laser scanning microscopy, and energy dispersive spectroscopy. Cellular biocompatibility was analyzed for 1 and 3 days after seeding. Cell adhesion and spreading were evaluated using confocal laser scanning microscopy (n=3). Cell proliferation was evaluated using methyl thiazolyl tetrazolium assay (n=3). Kruskal-Wallis and Bonferroni corrections were used to evaluate the statistical significance of the intergroup differences (α=.05). RESULTS: Gamma-ray sterilization of 3Y-TZP showed significantly higher surface roughness compared with titanium and gold (P<.002). On day 1, the proliferation and adhesion of MC3T3-E1 cells cultured on gamma-rayed 3Y-TZP were significantly higher than those cultured on gold (P<.05); however, cell spreading was significantly lower than that of titanium on days 1 and 3 (P<.05). On day 3, cell proliferation of gamma-rayed 3Y-TZP was significantly lower than that of unirradiated 3Y-TZP (P<.05). Cell adhesion of gamma-rayed 3Y-TZP was slightly lower than that of zirconia and titanium but without significant difference (P>.05). CONCLUSIONS: Gamma-rayed zirconia exhibited increased surface roughness compared with titanium and significantly decreased bioactivity compared with titanium and zirconia. The use of gamma-ray sterilization on zirconia is not promising regarding biocompatibility, and the effect of this sterilization method on implant materials warrants further investigation.


Assuntos
Materiais Dentários , Titânio , Camundongos , Animais , Teste de Materiais , Materiais Dentários/química , Zircônio/química , Ítrio/química , Propriedades de Superfície
2.
J Prosthet Dent ; 129(3): 478-485, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36621357

RESUMO

STATEMENT OF PROBLEM: Support structures are essential for the quality of resin-based prostheses made by the digital light processing (DLP), but few studies have evaluated the effect of support structure on the accuracy of zirconia-based anatomic contour prostheses. PURPOSE: The purpose of this in vitro study was to evaluate the effect of maximum support attachment angle (MSA) on the intaglio surface trueness of anatomic contour prostheses made by DLP and compare the trueness of 2-unit anatomic contour prostheses with that of those produced by milling. MATERIAL AND METHODS: Anatomic contour single-unit prostheses were manufactured using DLP and a suspension with 3-mol% yttria-stabilized zirconia. Four different conditions of MSA values to the vertical axis of the object (50, 55, 60, and 65 degrees) were applied (n=10). After printing, postprocessing, and sintering, all successfully produced prostheses were evaluated for intaglio surface trueness by considering the root mean square (RMS). Using the MSA showing the highest trueness, the 2-unit prostheses made by DLP (DLP group) were compared with milled (MIL group) prostheses in terms of intaglio accuracy (n=10). One-way analysis of variance and a post hoc pairwise comparison or independent t test were used for trueness analysis (α=.05). RESULTS: Three MSA groups (50, 55, and 60 degrees) were successfully produced with significant differences between the trueness of the single-unit prostheses for the groups with different MSA values (P<.05). The highest trueness was in the 50-degree MSA group. The 2-unit prostheses of the DLP group with 50-degree MSA showed significantly lower trueness than those of the MIL group (P<.05); however, the RMS values of both groups were lower than 50 µm. CONCLUSIONS: The intaglio surface trueness of anatomic contour DLP-generated prostheses can be improved by changing the MSA. The 50-degree MSA was beneficial for the accuracy of both single-unit and 2-unit DLP-generated prostheses, produced within clinically acceptable limits.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Zircônio , Prótese Total
3.
J Prosthodont ; 32(7): 608-615, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37421209

RESUMO

PURPOSE: This in vitro study aimed to evaluate the effects of restorative materials and scanning aid conditions on the accuracy and time efficiency of intraoral scans. MATERIALS AND METHODS: Identical anatomic contour crowns were fabricated using the following materials: hybrid ceramic, 3 mol% yttria-stabilized tetragonal zirconia, 4 mol% yttria-partially stabilized zirconia, 5 mol% yttria-partially stabilized zirconia, cobalt-chromium (Co-Cr), resin, lithium disilicate, and feldspathic ceramic. The models were digitized and analyzed for accuracy (n = 10) under three scanning aid conditions (powder-based, liquid-based, and none). Additionally, the effect of metal restorations on the scan accuracy of other crowns was investigated. The scan time for complete arches was also recorded. One-way analysis of variance, Welch analysis of variance, and post-hoc comparison or independent t-tests were used for trueness analysis, and the F-test was used to examine precision (α = 0.05). RESULTS: Significant differences were observed in the trueness of the different restorative materials under the no-scanning aid condition (P < 0.05). In contrast, no statistically significant difference among the groups was observed with the powder- or liquid-based scanning aid. For each restorative material, the no-scanning aid condition showed significantly lower trueness than that with powder- or liquid-based scanning aids. The presence of a Co-Cr crown did not affect the trueness of other restorations in the arch. The scan time efficiency significantly increased on applying a powder- or liquid-based scanning aid. CONCLUSIONS: Using a scanning aid was effective to improve the scan accuracy of the tested restorative materials and scan time efficiency. Applying scanning aids to existing intraoral restorations can help improve prosthesis quality and reduce the need for clinical adjustment at the occlusal or proximal contacts.


Assuntos
Cerâmica , Materiais Dentários , Pós , Coroas , Desenho Assistido por Computador
4.
J Dent ; 147: 105142, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38906454

RESUMO

OBJECTIVES: To compare implant supported crowns (ISCs) designed using deep learning (DL) software with those designed by a technician using conventional computer-aided design software. METHODS: Twenty resin-based partially edentulous casts (maxillary and mandibular) used for fabricating ISCs were evaluated retrospectively. ISCs were designed using a DL-based method with no modification of the as-generated outcome (DB), a DL-based method with further optimization by a dental technician (DM), and a conventional computer-aided design method by a technician (NC). Time efficiency, crown contour, occlusal table area, cusp angle, cusp height, emergence profile angle, occlusal contacts, and proximal contacts were compared among groups. Depending on the distribution of measured data, various statistical methods were used for comparative analyses with a significance level of 0.05. RESULTS: ISCs in the DB group showed a significantly higher efficiency than those in the DM and NC groups (P ≤ 0.001). ISCs in the DM group exhibited significantly smaller volume deviations than those in the DB group when superimposed on ISCs in the NC group (DB-NC vs. DM-NC pairs, P ≤ 0.008). Except for the number and intensity of occlusal contacts (P ≤ 0.004), ISCs in the DB and DM groups had occlusal table areas, cusp angles, cusp heights, proximal contact intensities, and emergence profile angles similar to those in the NC group (P ≥ 0.157). CONCLUSIONS: A DL-based method can be beneficial for designing posterior ISCs in terms of time efficiency, occlusal table area, cusp angle, cusp height, proximal contact, and emergence profile, similar to the conventional human-based method. CLINICAL SIGNIFICANCE: A deep learning-based design method can achieve clinically acceptable functional properties of posterior ISCs. However, further optimization by a technician could improve specific outcomes, such as the crown contour or emergence profile angle.


Assuntos
Desenho Assistido por Computador , Coroas , Aprendizado Profundo , Oclusão Dentária , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Humanos , Estudos Retrospectivos , Planejamento de Prótese Dentária/métodos , Software , Arcada Parcialmente Edêntula/reabilitação , Implantes Dentários
5.
J Dent ; 141: 104820, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38128820

RESUMO

OBJECTIVES: This study aimed to investigate the antimicrobial properties of three dimensionally-printed dental polymers (3DPs) incorporated with microencapsulated phytochemicals (MPs) and to assess their surface characteristics and cytotoxicity. METHODS: MPs derived from phytoncide oil and their specific chemical components were introduced into suspensions of three microbial species: Streptococcus gordonii, Streptococcus oralis, and Candida albicans. Optical density was measured to determine the microbial growth in the presence of MPs for testing their antimicrobial activity. MPs at 5% (w/w) were mixed with dental polymers and dispersants to 3DP discs. These microbial species were then seeded onto the discs and incubated for 24 h. The antibacterial and antifungal activities of MP-containing 3DPs were evaluated by counting the colony-forming units (n = 3). The biofilm formation on the 3DP was assessed by crystal violet staining assay (n = 3). Microbial viability was determined using a live-dead staining and CLSM observation (n = 3). Surface roughness and water contact angle were assessed (n = 10). Cytotoxicity of MP-containing 3DPs for human gingival fibroblast was evaluated by MTT assay. RESULTS: MPs, particularly (-)-α-pinene, suppressed the growth of all tested microbial species. MP-containing 3DPs significantly reduced the colony count (P ≤ 0.001) and biofilm formation (P ≤ 0.009), of all tested microbial species. Both surface roughness (P < 0.001) and water contact angle (P < 0.001) increased. The cytotoxicity remained unchanged after incorporating MPs to the 3DPs (P = 0.310). CONCLUSIONS: MPs effectively controlled the microbial growth on 3DPs as evidenced by the colony count, biofilm formation, and cell viability. Although MPs modified the surface characteristics, they did not influence the cytotoxicity of 3DPs. CLINICAL SIGNIFICANCE: Integration of MPs into 3DPs could produce dental prostheses or appliances with antimicrobial properties. This approach not only provides a proactive solution to reduce the risk of oral biofilm-related infection but also ensures the safety and biocompatibility of the material, thereby improving dental care.


Assuntos
Anti-Infecciosos , Biofilmes , Humanos , Propriedades de Superfície , Anti-Infecciosos/farmacologia , Candida albicans , Compostos Fitoquímicos/farmacologia , Água
6.
J Dent ; 141: 104830, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38163455

RESUMO

OBJECTIVES: This study compared the tooth morphology, internal fit, occlusion, and proximal contacts of dental crowns automatically generated via two deep learning (DL)-based dental software systems with those manually designed by an experienced dental technician using conventional software. METHODS: Thirty partial arch scans of prepared posterior teeth were used. The crowns were designed using two DL-based methods (AA and AD) and a technician-based method (NC). The crown design outcomes were three-dimensionally compared, focusing on tooth morphology, internal fit, occlusion, and proximal contacts, by calculating the geometric relationship. Statistical analysis utilized the independent t-test, Mann-Whitney test, one-way ANOVA, and Kruskal-Wallis test with post hoc pairwise comparisons (α = 0.05). RESULTS: The AA and AD groups, with the NC group as a reference, exhibited no significant tooth morphology discrepancies across entire external or occlusal surfaces. The AD group exhibited higher root mean square and positive average values on the axial surface (P < .05). The AD and NC groups exhibited a better internal fit than the AA group (P < .001). The cusp angles were similar across all groups (P = .065). The NC group yielded more occlusal contact points than the AD group (P = .006). Occlusal and proximal contact intensities varied among the groups (both P < .001). CONCLUSIONS: Crowns designed by using both DL-based software programs exhibited similar morphologies on the occlusal and axial surfaces; however, they differed in internal fit, occlusion, and proximal contacts. Their overall performance was clinically comparable to that of the technician-based method in terms of the internal fit and number of occlusal contact points. CLINICAL SIGNIFICANCE: DL-based dental software for crown design can streamline the digital workflow in restorative dentistry, ensuring clinically-acceptable outcomes on tooth morphology, internal fit, occlusion, and proximal contacts. It can minimize the necessity of additional design optimization by dental technician.


Assuntos
Aprendizado Profundo , Porcelana Dentária , Cerâmica , Coroas , Desenho Assistido por Computador , Planejamento de Prótese Dentária/métodos , Adaptação Marginal Dentária , Software
7.
Dent Mater J ; 43(2): 216-226, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38417860

RESUMO

This study aimed to investigate the effects of sandblasting on the physical properties and bond strength of two types of translucent zirconia: niobium-oxide-containing yttria-stabilized tetragonal zirconia polycrystals ((Y, Nb)-TZP) and 5 mol% yttria-partially stabilized zirconia (5Y-PSZ). Fully sintered disc specimens were either sandblasted with 125 µm alumina particles or left as-sintered. Surface roughness, crystal phase compositions, and surface morphology were explored. Biaxial flexural strength (n=10) and shear bond strength (SBS) (n=12) were evaluated, including thermocycling conditions. Results indicated a decrease in flexural strength of 5Y-PSZ from 601 to 303 MPa upon sandblasting, while (Y, Nb)-TZP improved from 458 to 544 MPa. Both materials significantly increased SBS after sandblasting (p<0.001). After thermocycling, (Y, Nb)-TZP maintained superior SBS (14.3 MPa) compared to 5Y-PSZ (11.3 MPa) (p<0.001). The study concludes that (Y, Nb)-TZP is preferable for sandblasting applications, particularly for achieving durable bonding without compromising flexural strength.


Assuntos
Materiais Dentários , Nióbio , Óxidos , Materiais Dentários/química , Teste de Materiais , Propriedades de Superfície , Zircônio/química , Ítrio/química , Óxido de Alumínio , Resistência ao Cisalhamento
8.
J Dent ; 138: 104739, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37804938

RESUMO

OBJECTIVES: To evaluate the time efficiency, occlusal morphology, and internal fit of dental crowns designed using generative adversarial network (GAN)-based dental software compared to conventional dental software. METHODS: Thirty datasets of partial arch scans for prepared posterior teeth were analyzed. Each crown was designed on each abutment using GAN-based software (AI) and conventional dental software (non-AI). The AI and non-AI groups were compared in terms of time efficiency by measuring the elapsed work time. The difference in the occlusal morphology of the crowns before and after design optimization and the internal fit of the crown to the prepared abutment were also evaluated by superimposition for each software. Data were analyzed using independent t tests or Mann-Whitney test with statistical significance (α=.05). RESULTS: The working time was significantly less for the AI group than the non-AI group at T1, T5, and T6 (P≤.043). The working time with AI was significantly shorter at T1, T3, T5, and T6 for the intraoral scan (P≤.036). Only at T2 (P≤.001) did the cast scan show a significant difference between the two groups. The crowns in the AI group showed less deviation in occlusal morphology and significantly better internal fit to the abutment than those in the non-AI group (both P<.001). CONCLUSIONS: Crowns designed by AI software showed improved outcomes than that designed by non-AI software, in terms of time efficiency, difference in occlusal morphology, and internal fit. CLINICAL SIGNIFICANCE: The GAN-based software showed better time efficiency and less deviation in occlusal morphology during the design process than the conventional software, suggesting a higher probability of optimized outcomes of crown design.


Assuntos
Coroas , Planejamento de Prótese Dentária , Adaptação Marginal Dentária , Desenho Assistido por Computador , Software , Porcelana Dentária
9.
Materials (Basel) ; 12(19)2019 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-31590370

RESUMO

A single-visit zirconia restoration can be easily achieved if direct milling of a fully sintered zirconia block can be performed without much effort. However, no studies have yet been reported regarding the evaluation of the trueness of crown fabricated from chairside-milling of a fully sintered zirconia block in the chairside computer-aided design and computer-aided manufacturing (CAD-CAM) system for single-visit dentistry. This in vitro study aimed to evaluate the trueness of crowns fabricated by milling a fully sintered zirconia block in the chairside CAD-CAM system and investigate the clinical implications for single-visit chairside restoration. Crowns were fabricated either by chairside-milling a fully sintered block of niobium oxide containing yttria-stabilized tetragonal zirconia polycrystals ((Y, Nb)-TZP) without the sintering process (n = 12) in a chairside single-visit dentistry system (Chairside group) or by laboratory-milling a partially sintered 3 mol% block of yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP) followed by the sintering process (n = 12) in a conventional laboratory system (Labside group). Crown fabrication time, milling tool diameter and the trueness of each crown were evaluated. All trueness values of both groups were within the clinically acceptable range, although a significant difference between the Chairside (43.0 ± 3.67 µm) and Labside groups (37.4 ± 2.41 µm) was observed (P < 0.05). Mean fabrication time was 0.52 h and 1.42 h for Chairside and Labside groups, respectively. A decrease in the tool diameter was observed for the Chairside group.

10.
PLoS One ; 12(7): e0180506, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28700729

RESUMO

BACKGROUND: Little is known about oral health related to electronic-cigarette (EC) use, even though EC use is increasing rapidly. The aim of this study is to assess the relationship between EC use and oral health, including 'gingival pain and/or bleeding', 'tongue and/or inside-cheek pain', and 'cracked or broken teeth' among adolescents. METHODS: A total of 65,528 students in 2016 were included in this cross-sectional study. RESULTS: For EC use, 0.5% (n = 297) students were daily users, 1.9% (n = 1259) were '1 to 29 days past month users', and 5.9% (n = 3848) were former users. Overall, 18.5% students reported they had experienced 'gingival pain and/or bleeding', 11.0% reported 'tongue and/or inside-cheek pain', and 11.4% reported a 'cracked or broken tooth' within the past 12 months. When comparing 'daily EC users', '1 to 29 days past month EC users', and 'former EC users' with 'never EC users', the adjusted ORs for 'cracked or broken tooth' were 1.65 (95% CI: 1.19-2.27), 1.26 (95% CI: 1.06-1.51), and 1.16 (95% CI: 1.04-1.30), respectively. Comparing 'daily EC users' with 'never EC users', the adjusted OR for 'tongue and/or inside-cheek pain' was 1.54 (1.05-2.26). However, EC use among adolescents was not associated with 'gingival pain and/or bleeding' when adjusted for the potential confounders. CONCLUSIONS: Based on the results, the odds of cracked or broken teeth among daily, '1 to 29 days past month', and former EC users were significantly higher than those among never EC users. The odds of tongue and/or inside-cheek pain among daily EC users were significantly higher than those among never EC users. In conclusion, the results suggest that daily EC use among adolescents may be a risk factor for cracked or broken teeth and tongue and/or inside-cheek pain.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina/efeitos adversos , Fraturas dos Dentes/etiologia , Adolescente , Bochecha/patologia , Estudos Transversais , Feminino , Gengiva/patologia , Hemorragia/etiologia , Humanos , Masculino , Análise Multivariada , Razão de Chances , Dor/etiologia , Dor/patologia , Fatores de Risco , Inquéritos e Questionários , Língua/patologia , Fraturas dos Dentes/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA