Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Oral Maxillofac Surg ; 79(5): 1107-1121, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33549539

RESUMO

PURPOSE: The relationship between pharyngeal airway morphology and jawbone movements in skeletal Class III patients with mandibular asymmetry after orthognathic surgery remains unclear. This study was to measure the changes in pharyngeal airway morphology in skeletal Class III patients with mandibular asymmetry after bimaxillary surgery and evaluate associations between changes in pharyngeal airway morphology and skeletal movements. METHODS: In this retrospective cohort study, skeletal Class III patients who underwent bimaxillary surgery were enrolled. The predictor variable was facial symmetry status divided into 2 groups, asymmetric (Group A) and symmetric (Group B). The primary outcome variables were changes in airway parameters, including cross-sectional linear distances, cross-sectional area (CSA), minimum CSA (Min-CSA), and volume; and airway asymmetry index between the preoperative and 6-month postoperative imaging studies. Correlation analysis was performed between upper airway and skeletal changes. RESULTS: Twenty-five patients were included in this study, with 15 patients in Group A (mean age: 23.00 years; BMI: 22.83) and 10 patients in Group B (mean age: 22.30 years; BMI: 22.48). Group A showed a higher asymmetry index than Group B at T0; however, no significant differences compared to Group B at T1. The airway volume was significantly decreased in the oropharynx in Group A at T1, whereas it showed no significant differences in Group B (P < .05). Lateral movement of B point and Menton showed positive correlations with changes in Min-CSA in the oropharynx and negative correlations with changes in airway asymmetry index (P < .05). CONCLUSIONS: Pharyngeal airway exhibited an asymmetrical and constricted morphology in Group A before surgery. The airway morphology in Group A showed a tendency to adopt a symmetrical and less constricted shape after surgery. The airway space was reduced in the oropharynx in Group A after surgery. Surgical correction of mandibular asymmetry correlated with the improvement of pharyngeal airway morphology.


Assuntos
Má Oclusão Classe III de Angle , Cirurgia Ortognática , Procedimentos Cirúrgicos Ortognáticos , Adulto , Cefalometria , Tomografia Computadorizada de Feixe Cônico , Humanos , Má Oclusão Classe III de Angle/diagnóstico por imagem , Má Oclusão Classe III de Angle/cirurgia , Faringe/diagnóstico por imagem , Estudos Retrospectivos , Adulto Jovem
2.
Medicina (Kaunas) ; 56(11)2020 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-33207656

RESUMO

The complete removal of obturation material can be a challenge in nonsurgical root canal retreatment. The insufficient removal of obturation material is a reason for root canal retreatment failure. The purpose of this study was to assess the efficacy of different final root canal irrigation activation methods in removing debris and smear layers in the apical and middle portions of root canals during retreatment. Sixty-six distal roots of freshly extracted molars were randomly divided into six groups: (1) primary root canal treatment with no obturation (negative control); (2) retreatment with only conventional instrumentation and irrigation (positive control); (3) retreatment with additional ultrasonic irrigation using the Piezon Master 700; (4) ultrasonic irrigation with the ENDOSONIC Blue; (5) sonic irrigation with the EDDY; and (6) multisonic irrigation with the GentleWave system. Roots were split and prepared for scanning electron microscopic (SEM) evaluation. Acquired images were assessed to quantify the amount of debris and smear remaining. Among the treatment groups, Group 6 had a significantly lower debris score than Group 2 (positive control) in both the middle and apical regions (p = 0.004, p = 0.012). All treatment groups showed significantly lower smear scores than Group 2 in the middle and apical regions (p < 0.05). The GentleWave multisonic System showed a more optimal cleaning efficacy of the root canal debris but did not differ significantly with the tested passive ultrasonic or sonic irrigation method.


Assuntos
Camada de Esfregaço , Cavidade Pulpar , Humanos , Retratamento , Irrigantes do Canal Radicular , Preparo de Canal Radicular
3.
BMC Oral Health ; 17(1): 110, 2017 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-28697771

RESUMO

BACKGROUND: Although many studies have compared the properties of ultrasonic scaling instruments, it remains controversial as to which is most suitable for implant scaling. This study evaluated the safety and efficiency of novel metallic ultrasonic scaler tips made by the powder injection molding (PIM) technique on titanium surfaces. METHODS: Mechanical instrumentation was carried out using four types of metal scaler tips consisting of copper (CU), bronze (BR), 316 L stainless steel (316 L), and conventional stainless steel (SS) tips. The instrumented surface alteration image of samples was viewed with scanning electron microscope (SEM) and surface profile of the each sample was investigated with confocal laser scanning microscopy (CLSM). Arithmetic mean roughness (Ra) and maximum height roughness (Rmax) of titanium samples were measured and dissipated power of the scaler tip was estimated for scaling efficiency. RESULTS: The average Ra values caused by the 316 L and SS tip were about two times higher than those of the CU and BR tips (p < 0.05). The Rmax value showed similar results. The efficiency of the SS tip was about 3 times higher than that of CU tip, the 316 L tip is about 2.7 times higher than that of CU tip, and the BR tip is about 1.2 times higher than that of CU tip. CONCLUSIONS: Novel metallic bronze alloy ultrasonic scaler tip minimally damages titanium surfaces, similar to copper alloy tip. Therefore, this bronze alloy scaler tip may be promising instrument for implant maintenance therapy.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária/métodos , Planejamento de Prótese Dentária/instrumentação , Humanos , Microscopia Confocal , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Titânio , Ultrassom
4.
Dent Mater J ; 41(5): 780-786, 2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-35768223

RESUMO

This study aimed to investigate in vitro biologic properties of mineral trioxide aggregate (MTA) mixed with 3% PVA (MTA-3% PVA) and in vivo dental pulp responses to direct capping in comparison with MTA mixed with distilled water (MTA-DW). Cell proliferation and osteogenic differentiation in culture of human dental pulp cells (hDPCs), and pH changes were evaluated. Pulps in 24 mandibular premolars of four 9-month-old beagle dogs were mechanically exposed and direct pulp capping was performed. Histological specimens were scored according to the degree of mineralization. MTA-3% PVA showed similar cell proliferation and similar or superior osteogenic differentiation of hDPCs compared with MTA-DW. All specimens were associated with calcified bridge formation and there were no significant differences in mineralization scores between the groups (p>0.05). The results suggested that MTA-3% PVA exhibited favorable biocompatibility and osteogenic differentiation in vitro compared with MTA-DW. Furthermore, both groups demonstrated similar results when used as pulp-capping agents in vivo.


Assuntos
Produtos Biológicos , Osteogênese , Animais , Pré-Escolar , Cães , Humanos , Compostos de Alumínio/farmacologia , Compostos de Cálcio/farmacologia , Polpa Dentária , Capeamento da Polpa Dentária/métodos , Combinação de Medicamentos , Óxidos/farmacologia , Polímeros , Silicatos/farmacologia , Água
5.
Materials (Basel) ; 13(19)2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33019753

RESUMO

The present study aimed to investigate the effects of different obturation techniques on the main and accessory canal filling quality of a premixed calcium silicate endodontic sealer (Endoseal TCS). We also highlighted the validity of the methods used for evaluating the canal filling quality. Thirty single-rooted premolars were used for the main canal filling and 75 were used for accessory canal filling. The canals were instrumented and randomly divided into three groups according to the filling techniques: (1) single-cone technique (SC), (2) single-cone with ultrasonic activation (SU), and (3) warm vertical compaction (WV). Voids in relation to the root canal fillings were assessed using cross-section images from microcomputed tomography (µCT) scans or transversely sectioned tooth specimens (n = 10). After demineralization and clearing of the teeth, the incidence, number, and completeness of the accessory canal fillings were evaluated (n = 25). One-way analysis of variance (ANOVA) and Tukey's post hoc test was used for the evaluation of the voids in the main root canal and the incidence and number of filled accessory canals. Pearson's chi-squared (χ2) test was used for the evaluation of the filling completeness (α = 0.05). In the stereomicroscopic evaluation of the sectioned specimen, the SC group had significantly higher void occurrence than the other groups (p < 0.05), although there was no difference between groups in the µCT evaluation. However, there was no difference between the SU and WV. There was no difference between all the groups regarding the incidence, number, and completeness of the accessory canal fillings. When the premixed calcium silicate sealer is used with SC, the ultrasonic activation is recommended to obtain a better main canal filling quality. In contrast, the obturation techniques did not affect the accessory canal filling. We also recommend using the sectioning method when the void formation in the root canal filling materials is evaluated.

6.
J Biomed Mater Res B Appl Biomater ; 107(5): 1440-1451, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30270515

RESUMO

A modified mineral-trioxide-aggregate (mMTA) with rapid setting capacity was newly synthesized by spray-pyrolysis following a sol-gel reaction. Its faster setting capacity and initially higher compressive strength compared with Portland cement (PC) were evaluated. The precursor solution of the mMTA was prepared through condensation following hydrolysis among Ca(NO3 )2 ·4H2 O, Si(OC2 H5 )4 , and Al(NO3 )3 ·9H2 O under nitric acid. The mMTA powder was then synthesized by spray-pyrolysis at 1500°C. The particle shape was spherical with an average particle size of 0.8 ± 0.3 µm, while PC particles were irregular and 3.9 ± 3.0 µm in size. The mMTA consisted of mostly Ca3 SiO5 , Ca3 Al2 O6 , and partial Ca2 SiO4 phases, while the PC comprised mainly Ca3 SiO5 , Ca2 SiO4 , and partial Ca3 Al2 O6 phases. The final setting times of mMTA and PC measured under 95% relative humidity were about 11 min and 3 h, respectively. The early stage of setting in mMTA was dominated by the rapid formation of hexagonal-plate-like Ca3 Al2 O6 ·6H2 O crystals, while that in PC was dominated by needle-like calcium-silicate-hydrate gels and columnar-shaped Ca(OH)2 crystals. The late stage of setting in mMTA was dominated by calcium-silicate-hydrate gels and Ca(OH)2 crystals, while that in PC was dominated by Ca3 Al2 O6 ·6H2 O crystals. The compressive strengths of mMTA and PC after 30 min of setting were 4.5 and 0.2 MPa, respectively. The results suggest that mMTA has potential to be used as a filling material for accidental pulp-exposure or pulpal floor perforation cases that require rapid setting capacity and initial good strength. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1440-1451, 2019.


Assuntos
Compostos de Alumínio/química , Compostos de Cálcio/química , Força Compressiva , Teste de Materiais , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Combinação de Medicamentos , Humanos
7.
Materials (Basel) ; 12(21)2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-31731396

RESUMO

The purpose of this study was to compare disinfection and the biofilm removal efficacy of the GentleWave System (Sonendo, Inc., Laguna Hills, CA, USA) with passive ultrasonic activation method. Forty-seven freshly extracted human molars were inoculated with Enterococcus faecalis and cultured for five weeks to establish biofilm. Eight molars were tested for confirmation of infection. Four of the eight teeth were not inoculated in order to provide a negative control. The remaining 39 inoculated molars were randomly separated into three treatment groups (n = 13 per group): Group 1-no treatment, Group 2-conventional rotary instrumentation and passive ultrasonic activation, and Group 3-minimal instrumentation and the GentleWave System treatment. Roots were subsequently prepared per standard histological tissue processing procedures. Modified Brown and Brenn stained sections and Hematoxylin and Eosin stained sections were visualized at 4× and 13.5× magnification using a stereomicroscope. The sections were scored and blindly analyzed by two independent evaluators, including a histopathologist, to evaluate the presence of biofilm on canal wall. A significant difference was found between Group 2 and Group 3 in both apical and middle regions (p = 0.001) of the mesial roots of mandibular molars and mesiobuccal roots of maxillary molars. Group 3 revealed significantly less biofilm than the controls (p = 0.003). The GentleWave System demonstrated significantly greater reduction in biofilm within the mesial roots of mandibular molars and mesiobuccal roots of maxillary molars than those treated with conventional rotary instrumentation and passive ultrasonic activation protocol.

8.
J Biomed Mater Res B Appl Biomater ; 106(1): 31-39, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29218856

RESUMO

A new method to deliver fluoride using biodegradable poly(lactic-co-glycolic acid) microcapsules to suppress cariogenic bacterial growth during orthodontic treatment was investigated. A coaxial ultrasonic atomizer was used to encapsulate KF solution into microcapsules. The orthodontic adhesive resin disk containing fluoride loaded microcapsules (DFLM) was prepared by LED light curing. The microstructure of microcapsules, successful loading of KF, fracture strength, and shear bonding strength were assessed by FE-SEM, confocal laser scanning microscope, and general purpose testing machine, respectively. Fluoride release from the DFLM in phosphate buffered saline and pH changes were measured after different periods of soaking time. Antibacterial activity of the DFLM was assessed in tryptic soy broth containing mutant streptococci. The starting inoculum and the orthodontic resin disk containing microcapsules not loaded with KF were used as negative and positive controls, respectively. As results, the cumulative amount of KF after 49 days was about 85% of the initial amount of fluoride contained in the microcapsules. The fracture and shear bonding strengths of the orthodontic resin disks with and without the microcapsules were similar to each other. The DFLM showed lower bacterial growth than the control groups, whereas no statistically significant differences were found between the negative and positive controls. It can be concluded that the microcapsules loaded with fluoride prepared by a coaxial ultrasonic atomizer have good potential for application as an antibacterial agent due to their excellent cariogenic antibacterial activity when incorporated into orthodontic adhesive resin. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 31-39, 2018.


Assuntos
Cárie Dentária/microbiologia , Fluoretos , Resinas Sintéticas , Streptococcus sobrinus/crescimento & desenvolvimento , Ondas Ultrassônicas , Cápsulas , Fluoretos/química , Fluoretos/farmacologia , Ácido Láctico/química , Ácido Láctico/farmacologia , Ácido Poliglicólico/química , Ácido Poliglicólico/farmacologia , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Resinas Sintéticas/química , Resinas Sintéticas/farmacologia
9.
Korean J Orthod ; 47(4): 229-237, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28670564

RESUMO

OBJECTIVE: The aim of this study was to compare the initial stability as insertion and removal torque and the clinical applicability of novel orthodontic zirconia micro-implants made using a powder injection molding (PIM) technique with those parameters in conventional titanium micro-implants. METHODS: Sixty zirconia and 60 titanium micro-implants of similar design (diameter, 1.6 mm; length, 8.0 mm) were inserted perpendicularly in solid polyurethane foam with varying densities of 20 pounds per cubic foot (pcf), 30 pcf, and 40 pcf. Primary stability was measured as maximum insertion torque (MIT) and maximum removal torque (MRT). To investigate clinical applicability, compressive and tensile forces were recorded at 0.01, 0.02, and 0.03 mm displacement of the implants at angles of 0°, 10°, 20°, 30°, and 40°. The biocompatibility of zirconia micro-implants was assessed via an experimental animal study. RESULTS: There were no statistically significant differences between zirconia micro-implants and titanium alloy implants with regard to MIT, MRT, or the amount of movement in the angulated lateral displacement test. As angulation increased, the mean compressive and tensile forces required to displace both types of micro-implants increased substantially at all distances. The average bone-to-implant contact ratio of prototype zirconia micro-implants was 56.88 ± 6.72%. CONCLUSIONS: Zirconia micro-implants showed initial stability and clinical applicability for diverse orthodontic treatments comparable to that of titanium micro-implants under compressive and tensile forces.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA