Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Am J Kidney Dis ; 65(5): 773-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25746151

RESUMO

BACKGROUND: Biocompatible solutions may lower peritonitis rates, but are more costly than conventional solutions. The aim of the present study was to assess the additional costs and health outcomes of biocompatible over conventional solutions in incident peritoneal dialysis patients to guide practice decisions. STUDY DESIGN: Secondary economic evaluation of a randomized controlled trial. SETTING & POPULATION: 185 participants in the balANZ trial. MODEL, PERSPECTIVE, & TIMEFRAME: Cost-effectiveness of biocompatible compared to standard solution over the 2 years using an Australian health care funder perspective. INTERVENTION: Intervention group received biocompatible solutions and control group received standard solutions over 2 years. OUTCOMES: Costs included dialysis charges, costs of treating peritonitis, non-peritonitis-related hospital stays, and medication. Peritonitis was the health outcome of interest; incremental cost-effectiveness ratios were reported in terms of the additional cost per additional patient avoiding peritonitis at 2 years. RESULTS: Mean total per-patient costs were A$57,451 and A$53,930 for the biocompatible and standard-solution groups, respectively. The base-case analysis indicated an incremental cost of A$17,804 per additional patient avoiding peritonitis at 2 years for biocompatible compared to standard solution. In a sensitivity analysis excluding extreme outliers for non-peritonitis-related hospitalizations, mean per-patient costs were A$49,159 and A$52,009 for the biocompatible and standard-solution groups, respectively. Consequently, the incremental cost-effectiveness ratio also was reduced significantly: biocompatible solution became both less costly and more effective than standard solution and, in economic terms, was dominant over standard solution. LIMITATIONS: Peritonitis was a secondary outcome of the balANZ trial. Health outcomes measured only in terms of patients avoiding peritonitis over 2 years may underestimate the longer term benefits (eg, prolonged technique survival). CONCLUSIONS: Biocompatible dialysis solutions may offer a cost-effective alternative to standard solutions for peritoneal dialysis patients. Reductions in peritonitis-related hospital costs may offset the higher costs of biocompatible solution.


Assuntos
Soluções para Diálise/química , Soluções para Diálise/economia , Adulto , Idoso , Materiais Biocompatíveis/economia , Análise Custo-Benefício , Feminino , Humanos , Concentração de Íons de Hidrogênio , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Anos de Vida Ajustados por Qualidade de Vida
2.
J Am Soc Nephrol ; 23(6): 1097-107, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22440906

RESUMO

The clinical benefits of using "biocompatible" neutral pH solutions containing low levels of glucose degradation products for peritoneal dialysis compared with standard solutions are uncertain. In this multicenter, open-label, parallel-group, randomized controlled trial, we randomly assigned 185 incident adult peritoneal dialysis patients with residual renal function to use either biocompatible or conventional solution for 2 years. The primary outcome measure was slope of renal function decline. Secondary outcome measures comprised time to anuria, fluid volume status, peritonitis-free survival, technique survival, patient survival, and adverse events. We did not detect a statistically significant difference in the rate of decline of renal function between the two groups as measured by the slopes of GFR: -0.22 and -0.28 ml/min per 1.73 m(2) per month (P=0.17) in the first year in the biocompatible and conventional groups, respectively, and, -0.09 and -0.10 ml/min per 1.73 m(2) per month (P=0.9) in the second year. The biocompatible group exhibited significantly longer times to anuria (P=0.009) and to the first peritonitis episode (P=0.01). This group also had fewer patients develop peritonitis (30% versus 49%) and had lower rates of peritonitis (0.30 versus 0.49 episodes per year, P=0.01). In conclusion, this trial does not support a role for biocompatible fluid in slowing the rate of GFR decline, but it does suggest that biocompatible fluid may delay the onset of anuria and reduce the incidence of peritonitis compared with conventional fluid in peritoneal dialysis.


Assuntos
Materiais Biocompatíveis/farmacologia , Soluções para Diálise/farmacologia , Falência Renal Crônica/terapia , Diálise Peritoneal/métodos , Peritonite/induzido quimicamente , Adulto , Idoso , Intervalos de Confiança , Estudos Cross-Over , Feminino , Seguimentos , Taxa de Filtração Glomerular , Glucose/farmacologia , Humanos , Concentração de Íons de Hidrogênio , Estimativa de Kaplan-Meier , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/mortalidade , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Diálise Peritoneal/efeitos adversos , Diálise Peritoneal/mortalidade , Peritonite/epidemiologia , Peritonite/fisiopatologia , Valores de Referência , Medição de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
3.
Perit Dial Int ; 36(2): 146-53, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26429421

RESUMO

UNLABELLED: ♦ BACKGROUND: The longitudinal trends of lipid parameters and the impact of biocompatible peritoneal dialysis (PD) solutions on these levels remain to be fully defined. The present study aimed to a) evaluate the influence of neutral pH, low glucose degradation product (GDP) PD solutions on serum lipid parameters, and b) explore the capacity of lipid parameters (total cholesterol [TC], triglyceride [TG], high density lipoprotein [HDL], TC/HDL, low density lipoprotein [LDL], very low density lipoprotein [VLDL]) to predict cardiovascular events (CVE) and mortality in PD patients. ♦ METHODS: The study included 175 incident participants from the balANZ trial with at least 1 stored serum sample. A composite CVE score was used as a primary clinical outcome measure. Multilevel linear regression and Poisson regression models were fitted to describe the trend of lipid parameters over time and its ability to predict composite CVE, respectively. ♦ RESULTS: Small but statistically significant increases in serum TG (coefficient 0.006, p < 0.001), TC/HDL (coefficient 0.004, p = 0.001), and VLDL cholesterol (coefficient 0.005, p = 0.001) levels and a decrease in the serum HDL cholesterol levels (coefficient -0.004, p = 0.009) were observed with longer time on PD, whilst the type of PD solution (biocompatible vs standard) received had no significant effect on these levels. Peritoneal dialysis glucose exposure was significantly associated with trends in TG, TC/HDL, HDL and VLDL levels. Baseline lipid parameter levels were not predictive of composite CVEs or all-cause mortality. ♦ CONCLUSION: Serum TG, TC/HDL, and VLDL levels increased and the serum HDL levels decreased with increasing PD duration. None of the lipid parameters were significantly modified by biocompatible PD solution use over the time period studied or predictive of composite CVE or mortality.


Assuntos
Soluções para Diálise/uso terapêutico , Lipídeos/sangue , Diálise Peritoneal , Insuficiência Renal Crônica/terapia , Idoso , Materiais Biocompatíveis/uso terapêutico , Doenças Cardiovasculares/prevenção & controle , Feminino , Glucose/metabolismo , Humanos , Concentração de Íons de Hidrogênio , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Análise de Regressão
4.
Perit Dial Int ; 32(5): 497-506, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22991015

RESUMO

BACKGROUND: A multicenter, multi-country randomized controlled trial (the balANZ study) recently reported that peritonitis rates significantly improved with the use of neutral-pH peritoneal dialysis (PD) solutions low in glucose degradation products ("biocompatible") compared with standard solutions. The present paper reports a secondary outcome analysis of the balANZ trial with respect to peritonitis microbiology, treatment, and outcomes. METHODS: Adult incident PD patients with residual renal function were randomized to receive either biocompatible or conventional (control) PD solutions for 2 years. RESULTS: The safety population analysis for peritonitis included 91 patients in each group. The unadjusted geometric mean peritonitis rates in those groups were 0.30 [95% confidence interval (CI): 0.22 to 0.41] episodes per patient-year for the biocompatible group and 0.49 (95% CI: 0.39 to 0.62) episodes per patient-year for the control group [incidence rate ratio (IRR): 0.61; 95% CI: 0.41 to 0.90; p = 0.01]. When specific causative organisms were examined, the rates of culture-negative, gram-positive, gram-negative, and polymicrobial peritonitis episodes were not significantly different between the biocompatible and control groups, although the biocompatible group did experience a significantly lower rate of non-pseudomonal gram-negative peritonitis (IRR: 0.41; 95% CI: 0.18 to 0.92; p = 0.03). Initial empiric antibiotic regimens were comparable between the groups. Biocompatible fluid use did not significantly reduce the risk of peritonitis-associated hospitalization (adjusted odds ratio: 0.80; 95% CI: 0.48 to 1.34), but did result in a shorter median duration of peritonitis-associated hospitalization (6 days vs 11 days, p = 0.05). Peritonitis severity was more likely to be rated as mild in the biocompatible group (37% vs 10%, p = 0.001). Overall peritonitis-associated technique failures and peritonitis-related deaths were comparable in the two groups. CONCLUSIONS: Biocompatible PD fluid use was associated with a broad reduction in gram-positive, gram-negative, and culture-negative peritonitis that reached statistical significance for non-pseudomonal gram-negative organisms. Peritonitis hospitalization duration was shorter, and peritonitis severity was more commonly rated as mild in patients receiving biocompatible PD fluids, although other peritonitis outcomes were comparable between the groups.


Assuntos
Materiais Biocompatíveis/farmacologia , Soluções para Diálise/farmacologia , Falência Renal Crônica/terapia , Diálise Peritoneal/métodos , Peritônio/microbiologia , Peritonite/microbiologia , Adulto , Antibacterianos , Austrália , Soluções para Diálise/química , Feminino , Hospitalização , Humanos , Concentração de Íons de Hidrogênio , Falência Renal Crônica/complicações , Falência Renal Crônica/microbiologia , Masculino , Nova Zelândia , Diálise Peritoneal/efeitos adversos , Peritônio/efeitos dos fármacos , Peritonite/tratamento farmacológico , Peritonite/epidemiologia , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA