Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 303
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
J Craniofac Surg ; 35(4): 1197-1200, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38829145

RESUMO

BACKGROUND: Odontogenic cutaneous fistula (OCF) is a pathologic communication between the cutaneous surface of the face and oral cavity. Majority of oral cutaneous fistulas are reported to arise from chronic dental infection. Delay in treatment may result in chronic tissue injury as well as cosmetic deformities. Lesions are often misdiagnosed, leading to delayed management. Misdiagnosis may be the result of the variability of clinical morphological presentation and location of lesions compounded by the lack of knowledge that these lesions can have dental etiology. It is estimated that half of patients with OCF undergo multiple dermatologic surgical operations, antibiotic regimens, and other excisions and biopsies before a correct diagnosis is made. Herein, we present a systematic review to detail cases of odontogenic cutaneous lesions that had been previously misdiagnosed or managed inappropriately. In addition, we include a case report from our own institution. The aims are to demonstrate various presentations of OCF, increase awareness of plastic surgeons and oral maxillofacial surgeons to this pathological condition, and reinforce the importance of prompt diagnosis and treatment. METHODS: The study was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. A literature search was conducted in PubMed, Web of Science, and Cochrane databases from January 1, 2013 to July 24, 2023. The following search terms were utilized: "odontogenic cutaneous fistula" OR "odontogenic cutaneous sinus." RESULTS: Twenty-three articles published between 2013 and 2023 were included in this review. In addition, we report a case from our own institution. A total of 28 cases were included in the review. CONCLUSIONS: Diagnosis of OCF is challenging for numerous reasons. Misdiagnosis can lead to multiple trials of antibiotics and surgical procedures as well as reoccurrence of the lesion. Cases summarized highlight the importance of communication between oral maxillofacial surgery, plastic surgery, other medical subspecialists, and dentists in the evaluation of patients with head and neck lesions. Physicians should consider dental etiology in the differential diagnosis of orofacial skin lesions, even if teeth appear normal on oral examination.


Assuntos
Fístula Cutânea , Adulto , Humanos , Masculino , Fístula Cutânea/diagnóstico , Fístula Cutânea/cirurgia , Fístula Dentária/diagnóstico , Diagnóstico Diferencial , Erros de Diagnóstico
2.
J Craniofac Surg ; 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39028179

RESUMO

The use of porcine-derived collagen membranes (PDCM) to improve intraoral soft tissue rehabilitation remains under investigation. Different degrees of crosslinking have yielded differences in resorption time and inflammation surrounding collagen membranes. The aim of this study was to evaluate the in vivo performance of bilayered PDCMs with varying degrees of crosslinking for the regeneration of oral soft tissue defects. Bilateral split-thickness oral mucosa defects were created in mandibles of beagles (n=17) and assigned to one of the following: bilayer PDCM (high crosslinking porcine dermis in sheet form-H-xlink) and (low crosslinking porcine dermis in sheet form-L-xlink), bilayer PDCM (non-crosslinked predicate collagen membrane in spongy form-Ctrl), or negative control (Sham) and compared with positive control (unoperated). Animals were euthanized after 4-, 8-, or 12-weeks of healing to evaluate soft tissue regeneration and remodeling through histomorphometric analyses. H-xlink membranes presented delayed healing with a poorly developed epithelial layer (analogous to the sham group) across time points. Relative to Ctrl at 8 and 12 weeks, defects treated with H-xlink presented no difference in semiquantitative scores ( P > 0.05), while L-xlink exhibited greater healing ( P = 0.042, P = 0.043, at 8 and 12 weeks, respectively). Relative to positive control, L-xlink exhibited similar healing at 8 weeks and greater healing at 12 weeks ( P = 0.037) with a well-developed epithelial layer. Overall, groups treated with L-xlink presented with greater healing relative to the positive control after 12 weeks of healing and may serve as an alternative to autologous grafts for intraoral soft tissue regeneration.

3.
J Esthet Restor Dent ; 36(2): 381-390, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37676053

RESUMO

PURPOSE: To evaluate the reliability and failure modes of ultrathin (0.5 mm) lithium disilicate, translucent and ultra-translucent zirconia crowns for posterior teeth restorations. MATERIALS AND METHODS: Fifty-four mandibular first molar crowns of three ceramic materials: (1) Lithium disilicate (e.max CAD, Ivoclar Vivadent), (2) 3Y-TZP (Zirconn Translucent, Vipi), and (3) 5Y-PSZ (Cercon XT, Dentsply Sirona), with 0.5 mm of thickness were milled and cemented onto composite resin abutments. Eighteen samples of each group were tested under mouth-motion step-stress accelerated life testing in a humid environment using mild, moderate, and aggressive profiles. Data was subjected to Weibull statistics. Use level curves were plotted and reliability was calculated for a given mission of 100,000 cycles at 100, 200, and 300 N. Fractographic analyses of representative samples were performed in scanning electron microscope. RESULTS: Beta (ß) values suggest that failures were dictated by material's strength for lithium disilicate and by fatigue damage accumulation for both zirconias. No significant differences were detected in Weibull modulus and characteristic strength among groups. At a given mission of 100,000 cycles at 100 N, lithium disilicate presented higher reliability (98% CB: 95-99) regarding 3Y-TZP and 5Y-PSZ groups (84% CB: 65%-93% and 79% CB: 37&-94%, respectively). At 200 N, lithium disilicate reliability (82% CB: 66%-91%) was higher than 5Y-PSZ (20% CB: 4%-44%) and not significantly different from 3Y-TZP (54% CB: 32%-72%). Furthermore, at 300 N no significant differences in reliability were detected among groups, with a notable reduction in the reliability of all materials. Fractographic analyses showed that crack initiated at the interface between the composite core and the ceramic crowns due to tensile stress generated at the intaglio surface. CONCLUSIONS: Ultrathin lithium disilicate crowns demonstrated higher reliability relative to zirconia crowns at functional loads. Lithium disilicate and zirconia crown's reliability decreased significantly for missions at higher loads and similar failure modes were observed regardless of crown material. The indication of 0.5 mm thickness crowns in high-load bearing regions must be carefully evaluated. CLINICAL SIGNIFICANCE: Ultraconservative lithium disilicate and zirconia crowns of 0.5 mm thickness may be indicated in anterior restorations and pre-molars. Their clinical indication in high-load requirement regions must be carefully evaluated.


Assuntos
Coroas , Porcelana Dentária , Reprodutibilidade dos Testes , Teste de Materiais , Cerâmica , Zircônio , Análise do Estresse Dentário , Falha de Restauração Dentária , Desenho Assistido por Computador
4.
J Prosthet Dent ; 130(5): 739.e1-739.e8, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37684141

RESUMO

STATEMENT OF PROBLEM: The bonding of implant-supported prostheses is determined by abutment material, convergence angle, height, surface treatment, and luting agents. However, studies evaluating the bonding of luting agents to titanium base abutments with different heights under fatigue conditions are scarce. PURPOSE: The purpose of this in vitro study was to evaluate the retention of zirconia crowns bonded with different luting agents to titanium base abutments of different heights before and after fatigue testing. MATERIAL AND METHODS: Zirconia crowns were designed, milled, and distributed into 4 experimental groups according to the luting agents (G-Multi Primer/G-Cem LinkForce [MP/GC] and Scotchbond Universal/RelyX Ultimate [SU/RU]) and titanium base abutment heights (2.5 mm and 4 mm) (n=10). Pull-out testing was performed in a universal testing machine at a crosshead speed of 1 mm/min until crown displacement. Fatigue testing was performed by an electric precision fatigue simulator (1×106 cycles; 100 N; and 15 Hz), followed by pull-out testing of fatigued specimens. Collected data were statistically evaluated by using a linear mixed model after post hoc comparisons by the least significant difference test (α=.05). RESULTS: Luting agents, abutment heights, and fatigue influenced the bonding retention of zirconia crowns to titanium base abutments. SU/RU agents promoted higher pull-out compared with MP/GC for both abutment heights before and after fatigue. Higher abutment height increased pull-out regarding lower abutment height for SU/RU materials before and after fatigue testing. Although fatigue had no significant effect on the pull-out of MP/GC, lower bond retention was observed for SU/RU after fatigue, regardless of abutment height. CONCLUSIONS: Luting agent composition and the interaction with abutment height and fatigue influenced the retention of zirconia crowns to titanium base abutments.


Assuntos
Cimentos Dentários , Implantes Dentários , Cimentos Dentários/química , Titânio/química , Coroas , Zircônio/química , Teste de Materiais , Dente Suporte , Análise do Estresse Dentário
5.
Int J Mol Sci ; 23(10)2022 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-35628440

RESUMO

It is well known that Semaphorin 4D (Sema4D) inhibits IGF-1-mediated osteogenesis by binding with PlexinB1 expressed on osteoblasts. However, its elevated level in the gingival crevice fluid of periodontitis patients and the broader scope of its activities in the context of potential upregulation of osteoclast-mediated periodontal bone-resorption suggest the need for further investigation of this multifaceted molecule. In short, the pathophysiological role of Sema4D in periodontitis requires further study. Accordingly, attachment of the ligature to the maxillary molar of mice for 7 days induced alveolar bone-resorption accompanied by locally elevated, soluble Sema4D (sSema4D), TNF-α and RANKL. Removal of the ligature induced spontaneous bone regeneration during the following 14 days, which was significantly promoted by anti-Sema4D-mAb administration. Anti-Sema4D-mAb was also suppressed in vitro osteoclastogenesis and pit formation by RANKL-stimulated BMMCs. While anti-Sema4D-mAb downmodulated the bone-resorption induced in mouse periodontitis, it neither affected local production of TNF-α and RANKL nor systemic skeletal bone remodeling. RANKL-induced osteoclastogenesis and resorptive activity were also suppressed by blocking of CD72, but not Plexin B2, suggesting that sSema4D released by osteoclasts promotes osteoclastogenesis via ligation to CD72 receptor. Overall, our data indicated that ssSema4D released by osteoclasts may play a dual function by decreasing bone formation, while upregulating bone-resorption.


Assuntos
Perda do Osso Alveolar , Periodontite , Perda do Osso Alveolar/etiologia , Animais , Antígenos CD , Regeneração Óssea , Modelos Animais de Doenças , Camundongos , Periodontite/patologia , Semaforinas , Fator de Necrose Tumoral alfa
6.
J Oral Implantol ; 48(6): 541-549, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35446950

RESUMO

The aim of this study was to clinically evaluate the guided bone regeneration (GBR) potential of allograft, xenograft, and alloplastic materials in combination with resorbable membranes in extraction sockets. The qualitative and quantitative assessments of this prospective study were accomplished through histologic and histomorphometric analysis. Three experimental groups and 1 control group for comparison (n = 8) received either an allograft (human cancellous bone, freeze dried, Deutsches Institut für Zell und Gewebeersatz, Berlin, Germany), xenograft (BioOss, Geistlich Pharma AG, Wolhusen, Switzerland), or alloplast (biphasic calcium sulphate, Bondbone, MIS Implants Technologies Ltd., Charlotte, NC). The negative control group received no regenerative material. Tissue samples were then qualitatively and quantitatively evaluated as a function of percentage of new vital bone, graft particles content, soft tissue, and bone marrow over time. All 3 study groups presented bone volume suitable for the successful placement of a dental implant. The xenograft group yielded significantly less amount of vital bone compared with the allograft and alloplast groups. When comparing the percentage of residual graft particles, there was significantly greater amounts associated with the xenograft group in contrast to the allograft and alloplast groups. Similarly, a significantly increased amount of soft tissue percentage was observed within the xenograft group relative to all other groups. No significant differences were observed in the percentage of residual graft particles between the allograft and alloplast groups. There were also no significant differences detected in vital bone percentage between the allograft, alloplast, and control groups. When evaluating the bone marrow percentage, the only significant difference detected was between the xenograft and alloplast materials. Overall, no complications (ie, fever, malaise, purulence or fistula) were observed during the entirety of clinical trial among all patients. The greatest GBR potential was associated with the allograft material because of the greater degree of vital bone and the lowest percentage of residual graft particles. All studied bone substitute materials resulted in bone apposition for efficient use in alveolar ridge preservation procedures.


Assuntos
Aumento do Rebordo Alveolar , Alvéolo Dental , Humanos , Xenoenxertos , Alvéolo Dental/cirurgia , Estudos Prospectivos , Transplante Homólogo , Aumento do Rebordo Alveolar/métodos , Transplante Ósseo/métodos , Extração Dentária , Aloenxertos/patologia , Aloenxertos/transplante , Membranas Artificiais
7.
J Oral Maxillofac Surg ; 79(2): 346-355, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33137302

RESUMO

PURPOSE: The aim of the present study was to systematically analyze how a multifactorial surgical instrumentation approach affects osseointegration on both narrow-diameter and wide-diameter short implants. MATERIALS AND METHODS: Twelve skeletally mature female sheep were used in the study along with 144 plateau-root-form healing chamber titanium (Ti-6Al-4V) implants (Bicon LLC, Boston, MA), evenly distributed between narrow (3.5 mm) and wide (6.0 mm) diameters. The presence or the absence of irrigation, different drilling speeds, and 2 time points quantifying bone-implant contact (BIC) and bone area fraction occupancy (BAFO) to evaluate the osteogenic parameters around the implants. RESULTS: There were no signs of inflammation, infection, or failure of the implants observed at either healing period. The narrow 3.5-mm implant, at 6 weeks, yielded significant differences in terms of BIC at a drilling speed of 50 rotations per minute (RPM), with higher values of the samples using irrigation (30.6 ± 6.1%) compared with those without (19.7 ± 6.1%). No statistical differences were detected for 500 and 1,000 RPM with or without irrigation. The wide 6-mm diameter implant showed differences with respect to drilling speed, 500 and 1,000 RPM, with higher values associated with samples subjected to irrigation. BAFO results, for both diameters, only detected statistical differences between the 2 times (3 vs 6 weeks); no statistical differences were detected when evaluating as a function of time, drilling speed, and irrigation. CONCLUSIONS: Surgical instrumentation variables (ie, drilling speed [RPM] and irrigation) yielded to be more of an effect for BIC at longer healing time (6 weeks) for the wider implants. Furthermore, deploying narrow or wide plateau-root-form implants, where conditions allow, has shown to be a safe alternative, considering the high BIC and BAFO values observed, independent of irrigation.


Assuntos
Implantes Dentários , Osseointegração , Animais , Boston , Implantação Dentária Endóssea , Ovinos , Propriedades de Superfície , Titânio
8.
Clin Oral Investig ; 25(10): 5867-5878, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33765194

RESUMO

OBJECTIVES: To evaluate peri-implant bone formation of titanium implants using an in vivo rat model with and without uncontrolled diabetes mellitus (DM) to evaluate osseointegration of hydrophobic (Neoporos®) and hydrophilic (Acqua®) surfaces. MATERIALS AND METHODS: 54 rats were divided into two groups: DM group (DMG) (streptozotocin-induced diabetes) and a control group (CG). Implants with hydrophobic (Neoporos®) and hydrophilic surfaces (Acqua®) were placed in the left or right tibia of animals. Animals were further divided into three groups (n = 9) euthanized after 7, 14, or 28 days. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were assessed in total, cortical, and medullary areas. RESULTS: The DMG group, after a 7-day healing period, yielded with the Acqua implants presented significantly higher total BIC (+37.9%; p=0.03) and trabecular BIC (%) (+46.3%; p=0.02) values in comparison to the Neoporos implants. After 28 days of healing, the CG yielded that the cortical BAFO of Acqua implants to be significantly, 14%, higher (p=0.04) than Neoporos implants. CONCLUSION: The positive effects of the Acqua surface were able to counteract the adverse impact of uncontrolled DM at early osseointegration periods. After 28 days in vivo, the metabolic systemic impairment caused by DM overcame the surface treatment effect, leading to impaired osseointegration in both hydrophilic and hydrophobic implants. CLINICAL RELEVANCE: The adverse effects of diabetes mellitus with respect to bone healing may be minimized by deploying implants with strategically modified surfaces. This study evaluated the effects of implants with Acqua® and Neoporos® surfaces in both diabetic and healthy animals. During the initial healing period in diabetic animals, the hydrophilic surface was demonstrated to have beneficial effect on osseointegration in comparison to the hydrophobic surface. The results provide an insight into early healing, but the authors suggest that a future short-term and long-term clinical study is needed to assess the possible benefit of the Acqua® implant as well as in increasing the predictability of implant osseointegration.


Assuntos
Implantes Dentários , Diabetes Mellitus Experimental , Animais , Osseointegração , Ratos , Propriedades de Superfície , Tíbia/cirurgia , Titânio
9.
Nat Mater ; 18(6): 627-637, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31114073

RESUMO

Cells are transplanted to regenerate an organs' parenchyma, but how transplanted parenchymal cells induce stromal regeneration is elusive. Despite the common use of a decellularized matrix, little is known as to the pivotal signals that must be restored for tissue or organ regeneration. We report that Alx3, a developmentally important gene, orchestrated adult parenchymal and stromal regeneration by directly transactivating Wnt3a and vascular endothelial growth factor. In contrast to the modest parenchyma formed by native adult progenitors, Alx3-restored cells in decellularized scaffolds not only produced vascularized stroma that involved vascular endothelial growth factor signalling, but also parenchymal dentin via the Wnt/ß-catenin pathway. In an orthotopic large-animal model following parenchyma and stroma ablation, Wnt3a-recruited endogenous cells regenerated neurovascular stroma and differentiated into parenchymal odontoblast-like cells that extended the processes into newly formed dentin with a structure-mechanical equivalency to native dentin. Thus, the Alx3-Wnt3a axis enables postnatal progenitors with a modest innate regenerative capacity to regenerate adult tissues. Depleted signals in the decellularized matrix may be reinstated by a developmentally pivotal gene or corresponding protein.


Assuntos
Proteínas de Homeodomínio/metabolismo , Tecido Parenquimatoso/fisiologia , Dente/citologia , Dente/embriologia , Adolescente , Animais , Feminino , Proteínas de Homeodomínio/genética , Humanos , Incisivo/citologia , Incisivo/embriologia , Camundongos Endogâmicos , Dente Serotino/citologia , Técnicas de Cultura de Órgãos , Tecido Parenquimatoso/citologia , Gravidez , Regiões Promotoras Genéticas , Regeneração , Células Estromais/fisiologia , Suínos , Fator A de Crescimento do Endotélio Vascular/genética , Proteína Wnt3A/genética , Proteína Wnt3A/metabolismo
10.
Periodontol 2000 ; 81(1): 139-151, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31407440

RESUMO

This paper is aimed to present a biomaterials perspective in implant therapy that fosters improved bone response and long-term biomechanical competence from surgical instrumentation to final prosthetic rehabilitation. Strategies to develop implant surface texturing will be presented and their role as an ad hoc treatment discussed in light of the interplay between surgical instrumentation and implant macrogeometric configuration. Evidence from human retrieved implants in service for several years and from in vivo studies will be used to show how the interplay between surgical instrumentation and implant macrogeometry design affect osseointegration healing pathways, and bone morphologic and long-term mechanical properties. Also, the planning of implant-supported prosthetic rehabilitations targeted at long-term performance will be appraised from a standpoint where personal preferences (eg, cementing or screwing a prosthesis) can very often fail to deliver the best patient care. Lastly, the acknowledgement that every rehabilitation will have its strength degraded over time once in function will be highlighted, since the potential occurrence of even minor failures is rarely presented to patients prior to treatment.


Assuntos
Implantes Dentários , Materiais Biocompatíveis , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Humanos , Osseointegração
11.
J Craniofac Surg ; 30(2): 607-610, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30507887

RESUMO

OBJECTIVE: The aim of this in vivo study is to compare the osseointegration of endosteal implants placed in atrophic mandibular alveolar ridges with alveolar ridge expansion surgical protocol via an experimental osseodensification drilling versus conventional osteotome technique. METHODS: Twelve endosteal implants, 4 mm × 13 mm, were placed in porcine models in horizontally atrophic mandibular ridges subsequent to prior extraction of premolars. Implants were placed with osseodensification drilling technique as the experimental group (n = 6) and osteotome site preparation as the control group (n = 6). After 4 weeks of healing, samples were retrieved and stained with Stevenel's Blue and Van Gieson's Picro Fuschin for histologic evaluation. Quantitative analysis via bone-to-implant contact (BIC%) and bone area fraction occupancy (BAFO%) were obtained as mean values with corresponding 95% confidence interval. A significant omnibus test, post-hoc comparison of the 2 drilling techniques' mean values was accomplished using a pooled estimate of the standard error with P-value set at 0.05. RESULTS: The mean BIC% value was approximately 62.5% in the osseodensification group, and 31.4% in the regular instrumentation group. Statistical analysis showed a significant effect of the drilling technique (P = 0.018). There was no statistical difference in BAFO as a function of drilling technique (P = 0.198). CONCLUSION: The combined osseodensification drilling-alveolar ridge expansion technique showed increased evidence of osseointegration and implant primary stability from a histologic and biomechanical standpoint, respectively. Future studies will focus on expanding the sample size as well as the timeline of the study to allow investigation of long-term prognosis of this novel technique.


Assuntos
Processo Alveolar/cirurgia , Implantação Dentária Endóssea/métodos , Mandíbula/cirurgia , Osseointegração/fisiologia , Osteotomia/métodos , Animais , Suínos
12.
J Surg Res ; 223: 115-122, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29433862

RESUMO

BACKGROUND: Vascularized bone tissue transfer, commonly used to reconstruct large mandibular defects, is challenged by long operative times, extended hospital stay, donor-site morbidity, and resulting health care. 3D-printed osseoconductive tissue-engineered scaffolds may provide an alternative solution for reconstruction of significant mandibular defects. This pilot study presents a novel 3D-printed bioactive ceramic scaffold with osseoconductive properties to treat segmental mandibular defects in a rabbit model. METHODS: Full-thickness mandibulectomy defects (12 mm) were created at the mandibular body of eight adult rabbits and replaced by 3D-printed ceramic scaffold made of 100% ß-tricalcium phosphate, fit to defect based on computed tomography imaging. After 8 weeks, animals were euthanized, the mandibles were retrieved, and bone regeneration was assessed. Bone growth was qualitatively assessed with histology and backscatter scanning electron microscopy, quantified both histologically and with micro computed tomography and advanced 3D image reconstruction software, and compared to unoperated mandible sections (UMSs). RESULTS: Histology quantified scaffold with newly formed bone area occupancy at 54.3 ± 11.7%, compared to UMS baseline bone area occupancy at 55.8 ± 4.4%, and bone area occupancy as a function of scaffold free space at 52.8 ± 13.9%. 3D volume occupancy quantified newly formed bone volume occupancy was 36.3 ± 5.9%, compared to UMS baseline bone volume occupancy at 33.4 ± 3.8%, and bone volume occupancy as a function of scaffold free space at 38.0 ± 15.4%. CONCLUSIONS: 3D-printed bioactive ceramic scaffolds can restore critical mandibular segmental defects to levels similar to native bone after 8 weeks in an adult rabbit, critical sized, mandibular defect model.


Assuntos
Mandíbula/cirurgia , Impressão Tridimensional , Alicerces Teciduais , Animais , Regeneração Óssea , Cerâmica , Coelhos
13.
J Oral Maxillofac Surg ; 76(1): 71-79, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28893541

RESUMO

PURPOSE: This work evaluated the nanomechanical properties of bone surrounding submerged and immediately loaded implants after 3 years in vivo. It was hypothesized that the nanomechanical properties of bone would markedly increase in immediately and functionally loaded implants compared with submerged implants. MATERIALS AND METHODS: The second, third, and fourth right premolars and the first molar of 10 adult Doberman dogs were extracted. After 6 months, 4 implants were placed in 1 side of the mandible. The mesial implant received a cover screw and remained unloaded. The remaining 3 implants received fixed dental prostheses within 48 hours after surgery that remained in occlusal function for 3 years. After sacrifice, the bone was prepared for histologic and nanoindentation analysis. Nanoindentation was carried out under wet conditions on bone areas within the plateaus. Indentations (n = 30 per histologic section) were performed with a maximum load of 300 µN (loading rate, 60 µN per second) followed by a holding and unloading time of 10 and 2 seconds, respectively. Elastic modulus (E) and hardness (H) were computed in giga-pascals. The amount of bone-to-implant contact (BIC) also was evaluated. RESULTS: The E and H values for cortical bone regions were higher than those for trabecular bone regardless of load condition, but this difference was not statistically significant (P > .05). The E and H values were higher for loaded implants than for submerged implants (P < .05) for cortical and trabecular bone. For the same load condition, the E and H values for cortical and trabecular bone were not statistically different (P > .05). The loaded and submerged implants presented BIC values (mean ± standard deviation) of 57.4 ± 12.1% and 62 ± 7.5%, respectively (P > .05). CONCLUSION: The E and H values of bone surrounding dental implants, measured by nanoindentation, were higher for immediately loaded than for submerged implants.


Assuntos
Processo Alveolar/ultraestrutura , Implantação Dentária Endóssea/métodos , Implantes Dentários , Mandíbula/cirurgia , Animais , Dente Pré-Molar , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Cães , Implantes Experimentais , Dente Molar
14.
J Oral Maxillofac Surg ; 76(8): 1677-1687, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29572133

RESUMO

PURPOSE: The increasing prevalence of obesity or metabolic syndrome (O/MS) and type 2 diabetes mellitus (DM) remains a global health concern. Clinically relevant and practical translational models mimicking human characteristics of these conditions are lacking. This study aimed to demonstrate proof of concept of the induction of stable O/MS and type 2 DM in a Göttingen minipig model and validate both of these disease-adjusted Göttingen minipig models as impaired healing models for the testing of dental implants. MATERIALS AND METHODS: Nine minipigs were split into 3 groups-control (normal diet), obese (cafeteria diet), and diabetic (cafeteria diet plus low-dosage streptozotocin)-followed by placement of dental implants. Inflammatory markers including tumor necrosis factor α, C-reactive protein, and cortisol were recorded for each study group. Removal torque was measured, and histomorphometric analysis (bone-to-implant contact and bone area fraction occupancy) was performed. RESULTS: O/MS pigs showed, on average, a 2-fold increase in plasma C-reactive protein (P < .05) and cortisol (P < .09) concentrations compared with controls; DM pigs showed, on average approximately, a 40-fold increase in plasma tumor necrosis factor α levels (P < .05) and a 2-fold increase in cortisol concentrations (P < .05) compared with controls. The impact of O/MS and DM on implants was determined. The torque to interface failure was highest in the control group (200 N-cm) and significantly lower in the O/MS (90 N-cm) and DM (60 N-cm) groups (P < .01). Bone formation around implants was significantly greater in the control group than in the O/MS and DM groups (P < .02). CONCLUSIONS: Both O/MS and DM minipigs express a human-like disease phenotype, and both presented bone-healing impairment around dental implants. Our finding of no significant difference between type 2 DM and O/MS in bone formation around implants provides evidence that further investigation of the impact of O/MS is warranted.


Assuntos
Implantes Dentários , Diabetes Mellitus Tipo 2/fisiopatologia , Síndrome Metabólica/fisiopatologia , Osseointegração/fisiologia , Animais , Biomarcadores/sangue , Modelos Animais de Doenças , Fenótipo , Projetos Piloto , Estudo de Prova de Conceito , Suínos , Porco Miniatura , Cicatrização/fisiologia
15.
Implant Dent ; 27(2): 165-170, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29351113

RESUMO

PURPOSE: To evaluate the probability of survival and failure modes of different external hexagon connection systems restored with anterior cement-retained single-unit crowns. The postulated null hypothesis was that there would be no differences under accelerated life testing. MATERIALS AND METHODS: Fifty-four external hexagon dental implants (∼4 mm diameter) were used for single cement-retained crown replacement and divided into 3 groups: (3i) Full OSSEOTITE, Biomet 3i (n = 18); (OL) OEX P4, Osseolife Implants (n = 18); and (IL) Unihex, Intra-Lock International (n = 18). Abutments were torqued to the implants, and maxillary central incisor crowns were cemented and subjected to step-stress-accelerated life testing in water. Use-level probability Weibull curves and probability of survival for a mission of 100,000 cycles at 200 N (95% 2-sided confidence intervals) were calculated. Stereo and scanning electron microscopes were used for failure inspection. RESULTS: The beta values for 3i, OL, and IL (1.60, 1.69, and 1.23, respectively) indicated that fatigue accelerated the failure of the 3 groups. Reliability for the 3i and OL (41% and 68%, respectively) was not different between each other, but both were significantly lower than IL group (98%). Abutment screw fracture was the failure mode consistently observed in all groups. CONCLUSION: Because the reliability was significantly different between the 3 groups, our postulated null hypothesis was rejected.

16.
Implant Dent ; 27(5): 582-587, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30134265

RESUMO

PURPOSE: To evaluate Ti-Base abutment height and cement type on the retentiveness of zirconia-based restorations. MATERIAL AND METHODS: Four millimeter (tall) and 2.5-mm-height (short) abutments along with temporary (provisional), glass ionomer (Meron), self-adhesive (U200), and conventional resin cement (Ultimate) were evaluated using pull-out testing (n = 10 crowns/group). RESULTS: Tall and short abutments demonstrated similar retention for all within cement comparisons, except U200 (P = 0.032). Resin cements exhibited superior retentiveness than others (P < 0.01). Although no significant difference was evidenced between resin cements for short abutments, Ultimate evidenced higher retention than U200 for tall abutments (P = 0.043). CONCLUSIONS: Although Ti-Base abutment height has not influenced zirconia superstructures' retentiveness, resin-based cements significantly evidenced higher retention than glass ionomer and temporary cements.


Assuntos
Desenho Assistido por Computador , Coroas , Dente Suporte , Cimentos Dentários/uso terapêutico , Projeto do Implante Dentário-Pivô , Planejamento de Prótese Dentária , Zircônio , Planejamento de Prótese Dentária/métodos , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro/uso terapêutico , Humanos , Cimentos de Resina/uso terapêutico
17.
J Prosthet Dent ; 119(1): 103-107, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28461048

RESUMO

STATEMENT OF PROBLEM: Few studies have investigated the voids and gaps produced during the cementation of fiber posts using different techniques. PURPOSE: The purpose of this study was to evaluate and quantify void and gap area formations of different fiber post cementation techniques using microcomputed tomography (µCT). MATERIAL AND METHODS: Standardized endodontically treated acrylic resin roots (N=24) were divided into 4 groups (n=6) according to different fiber posts cemented with the resin cement (FB); fiber posts relined with composite resin followed by cementation (FBR); fiber posts cemented using an ultrasonic device (FBU); and fiber posts relined with composite resin and cemented using an ultrasonic device (FBRU). Each specimen was scanned twice using micro-computed tomography (µCT; empty root, followed by after fiber post cementation). Digital imaging and communications in medicine (DICOM) files were transferred into 3-dimensional (3D) reconstruction software for analysis. Void volume in the cementation system and gap area formation were evaluated; quantitative and qualitative analyses were performed. The data were analyzed using 2-way ANOVA and the Tukey honest significant difference post hoc test (α=.05). RESULTS: FBR showed a lower percentage of voids than obtained for FB (P<.05). Groups FB, FBU, and FBRU did not show significant difference in void formation (P>.05). No significant differences were found in gap area formations among the experimental groups (P>.05). CONCLUSIONS: The use of a composite resin to reline the fiber post significantly decreased the void formation in the cementation procedure when no ultrasonic device was used. The use of an ultrasonic device did not decrease the percentage of void or gap formation for any technique evaluated.


Assuntos
Cimentação/métodos , Resinas Compostas , Dentina/diagnóstico por imagem , Técnica para Retentor Intrarradicular , Raiz Dentária/diagnóstico por imagem , Microtomografia por Raio-X , Humanos , Técnicas In Vitro
18.
J Prosthodont ; 27(7): 659-664, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27859976

RESUMO

PURPOSE: To evaluate the reliability of narrow diameter dental implants (NDIs) with similar macrogeometry and 3 implant-abutment connection designs. MATERIALS AND METHODS: Eighty-four NDIs (3.5 × 10 mm) were selected and divided into 4 groups (n = 21/group) according to implant-abutment connection design, as follows: EH - external hexagon, IH - internal hexagon, IC - internal conical, and IC-M - internal conical connected to a monolithic titanium abutment. Identical abutments were torqued to the implants, and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. Use of level probability Weibull curves, and reliability for a mission of 50,000 cycles at 75 N and 200 N were calculated. RESULTS: The beta (ß) values were: 1.48 for IC, 1.40 for IC-M, 8.54 for EH, and 1.98 for IH, indicating that damage accumulation was an acceleration factor for failure of all groups. At 75 N the probability of survival was not significantly different between groups. A decrease in reliability was observed for all groups at 200 N with no significant differences between IC (81.71%) and IC-M (94.28%), or between EH and IH (0%) which presented the lowest values. EH failures were primarily restricted to the screw, while IH involved screw and implant fracture. IC and IC-M were restricted to prosthetic failures (fracture and bending). CONCLUSIONS: Narrow implants with external or internal hexagon connections presented the lowest reliability at high loads compared to internal conical connections. Failure modes differed among connections.


Assuntos
Coroas , Projeto do Implante Dentário-Pivô , Falha de Restauração Dentária , Análise do Estresse Dentário , Incisivo , Teste de Materiais , Titânio , Torque
19.
J Prosthodont ; 27(1): 83-87, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26916603

RESUMO

PURPOSE: A ceramic and metal abutment prototype was fatigue tested to determine the probability of survival at various loads. MATERIALS AND METHODS: Lithium disilicate CAD-milled abutments (n = 24) were cemented to titanium sleeve inserts and then screw attached to titanium fixtures. The assembly was then embedded at a 30° angle in polymethylmethacrylate. Each (n = 24) was restored with a resin-cemented machined lithium disilicate all-ceramic central incisor crown. Single load (lingual-incisal contact) to failure was determined for three specimens. Fatigue testing (n = 21) was conducted employing the step-stress method with lingual mouth motion loading. Failures were recorded, and reliability calculations were performed using proprietary software. Probability Weibull curves were calculated with 90% confidence bounds. Fracture modes were classified with a stereomicroscope, and representative samples imaged with scanning electron microscopy. RESULTS: Fatigue results indicated that the limiting factor in the current design is the fatigue strength of the abutment screw, where screw fracture often leads to failure of the abutment metal sleeve and/or cracking in the implant fixture. Reliability for completion of a mission at 200 N load for 50K cycles was 0.38 (0.52% to 0.25 90% CI) and for 100K cycles was only 0.12 (0.26 to 0.05)-only 12% predicted to survive. These results are similar to those from previous studies on metal to metal abutment/fixture systems where screw failure is a limitation. No ceramic crown or ceramic abutment initiated fractures occurred, supporting the research hypothesis. The limiting factor in performance was the screw failure in the metal-to-metal connection between the prototyped abutment and the fixture, indicating that this configuration should function clinically with no abutment ceramic complications. CONCLUSION: The combined ceramic with titanium sleeve abutment prototype performance was limited by the fatigue degradation of the abutment screw. In fatigue, no ceramic crown or ceramic abutment components failed, supporting the research hypothesis with a reliability similar to that of all-metal abutment fixture systems. A lithium disilcate abutment with a Ti alloy sleeve in combination with an all-ceramic crown should be expected to function clinically in a satisfactory manner.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô , Porcelana Dentária , Análise do Estresse Dentário , Cerâmica , Desenho Assistido por Computador , Humanos , Titânio
20.
J Oral Maxillofac Surg ; 75(5): 1004.e1-1004.e9, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28137635

RESUMO

PURPOSE: To investigate the influence of different materials and fixation methods on maximum principal stress (MPS) and displacement in reconstruction plates using in silico 3-dimensional finite element analysis (3D-FEA). MATERIALS AND METHODS: Computer-assisted designed (CAD) models of the mandible and teeth were constructed. Champy and AO/ASIF plates and fixation screws were designed with CAD software. 3D-FEA was performed by image-based CAE software. Maximum and minimum values of biomechanical stability, MPS, and displacement distribution were compared in Champy and AO/ASIF plates made from commercially pure titanium grade 2 (cp-Ti) and a titanium-and-molybdenum (14.47% wt) alloy (Ti-15Mo). RESULTS: For plates fixed on a model of a fractured left angle of the mandible, the maximum and minimum values of MPS in the cp-Ti-constructed Champy plate, upper AO/ASIF plate, and lower AO/ASIF plate were 19.5 and 20.3%, 15.2 and 25.3%, and 21.4 and 4.6% lower, respectively, than those for plates made from Ti-15Mo. In the same model, the maximum and minimum values of displacement in the cp-Ti-constructed Champy plate, upper AO/ASIF plate, and lower AO/ASIF plate were 1.6 and 3.8%, 3.1 and 2.7%, and 5.4 and 10.4% higher, respectively, than those for plates made from Ti-15Mo. CONCLUSIONS: This in silico 3D-FEA shows that Ti-15Mo plates have greater load-bearing capability.


Assuntos
Placas Ósseas , Simulação por Computador , Fraturas Mandibulares/cirurgia , Titânio , Fenômenos Biomecânicos , Humanos , Procedimentos Ortopédicos/métodos , Procedimentos de Cirurgia Plástica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA