Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Molecules ; 27(19)2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-36234783

RESUMO

The main objective of this work was to assess Eucalyptus globulus lignin as an adsorbent and compare the results with kraft lignin, which has previously been demonstrated to be an effective adsorbent. Eucalypt lignin was extracted (by the dioxane technique), characterised, and its adsorption properties for Cr(VI) ions were evaluated. The monomeric composition of both types of lignin indicated a high content of guaiacyl (G) and syringyl (S) units but low content of p-hydroxyphenyl (H), with an H:G:S ratio of 1:50:146 (eucalypt lignin) and 1:16:26 (kraft lignin), as determined by Py-GC/MS. According to elemental analysis, sulphur (2%) and sodium (1%) were found in kraft lignin, but not in eucalypt lignin. The adsorption capacity of the eucalypt lignin was notably higher than the kraft lignin during the first 8 h, but practically all the ions had been absorbed by both the eucalypt and kraft lignin after 24 h (93.4% and 95%, respectively). Cr(VI) adsorption onto both lignins fitted well using the Langmuir adsorption isotherm model, with capacities of 256.4 and 303.0 mg/g, respectively, for eucalypt and kraft. The study's overall results demonstrate the great potential of eucalypt lignin as a biosorbent for Cr(VI) removal from aqueous solutions.


Assuntos
Cromo , Poluentes Químicos da Água , Adsorção , Dioxanos , Concentração de Íons de Hidrogênio , Íons , Cinética , Lignina , Sódio , Enxofre
2.
EuroIntervention ; 17(3): 233-239, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-33433389

RESUMO

BACKGROUND: The BioFreedom drug-coated stent with a stainless steel platform (BF-SS) has been demonstrated to be efficacious in patients at high bleeding risk and receiv-ing only one-month dual antiplatelet therapy. AIMS: The aim of this study was to evaluate the efficacy of the new BioFreedom Ultra drug-coated stent with a thin-strut cobalt-chromium platform (BF-CoCr) compared to the BF-SS in an all-comers population undergoing percutaneous coronary intervention (PCI). METHODS: This was a prospective, multicentre, non-inferiority trial. The primary endpoint was in-stent late lumen loss (LLL) as determined by quantitative coronary angiography at nine-month follow-up. Clinical evaluation was performed at one year. RESULTS: A total of 200 patients were randomised (1:1) to either the BF-CoCr or the BF-SS stent at eight centres in Spain and Denmark. Baseline clinical and lesion characteristics were similar between the groups. Mean age was 66 years and 23% were female. The mean number of stents implanted per patient was 1.5. At nine-month follow-up, mean in-stent LLL was 0.34±0.49 mm in the BF-CoCr group versus 0.29±0.37 mm in the BF-SS group, p=0.005 for non-inferiority. At one year, target lesion failure was similar between the groups (7.3% in BF-CoCr vs 9.3% in the BF-SS group; p=0.60). CONCLUSIONS: The BF-CoCr was non-inferior to the BF-SS in terms of in-stent LLL at nine months. Larger studies powered for clinical endpoints are warranted to compare the efficacy of this new platform with currently available DES.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Idoso , Feminino , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sirolimo/uso terapêutico , Espanha , Stents , Resultado do Tratamento
3.
Int J Cardiovasc Imaging ; 34(3): 353-365, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28965166

RESUMO

The aim of this study was to compare neointima proliferation in three drug-eluting stents (DES) produced by the same company (Balton, Poland) which are covered with a biodegradable polymer and elute sirolimus (concentration: 1.0 and 1.2 µg/mm2), but have different stent platforms and strut thickness: stainless steel Prolim® (115 µm) and BiOSS LIM® (120 µm) and cobalt-chromium Alex® (70 µm). We analyzed data of patients with quantitative coronary angiography (QCA) and optical coherence tomography (OCT) at 12 months from BiOSS LIM Registry, Prolim Registry and Alex OCT clinical trial. There were 56 patients enrolled, in whom 29 Prolim® stents were deployed, in 11-BiOSS LIM® and in 16-Alex stents. The late lumen loss was the smallest in Prolim® subgroup (0.26 ± 0.17 mm) and did not differ from Alex® subgroup (0.28 ± 0.47 mm). This parameter was significantly bigger in BiOSS® subgroup (0.38 ± 0.19 mm; p < 0.05). In OCT analysis there was no statistically significant difference between Prolim® and Alex® subgroups in terms of mean neointima burden (24.6 ± 8.6 vs. 19.27 ± 8.11%) and neointima volume (28.16 ± 15.10 vs. 24.51 ± 17.64 mm3). In BiOSS® group mean neointima burden (30.9 ± 6.2%) and mean neointima volume (44.9 ± 4.9 mm3) were significantly larger. The morphological analysis revealed that in most cases in all groups the neointima was homogenous with plaque presence only around stent struts. In the QCA and OCT analysis regular DES (Prolim® and Alex®) obtained similar results, whereas more pronounced response from the vessel wall was found in the BiOSS® subgroup.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/efeitos adversos , Proliferação de Células , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
4.
EuroIntervention ; 14(7): 780-788, 2018 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-29901444

RESUMO

AIMS: This study aimed to establish the early healing and neointimal transformation profile of the new polymer-free BioFreedom stent through sequential optical coherence tomography (OCT) within the first nine months following stent implantation. METHODS AND RESULTS: We randomly assigned 104 BFS recipients to one of five groups with angiography and OCT follow-up at 1, 2, 3, 4, or 5 months, together with another follow-up for all at nine months. The primary endpoint was the degree of OCT-detected strut coverage at nine months. From 1, 2, 3, 4, and 5 months, median neointimal strut coverage increased from 85.8, 87.0, 88.6, 96.8 to 97.1%, respectively, to 99.6% (IQR 98.2-99.9) at nine months. At nine months, median percent neointimal volume was 13.0% and angiographic late lumen loss was 0.21±0.30 mm. Major adverse cardiac events (MACE) were limited to one non-cardiac death, one non-ST-elevation myocardial infarction not related to BFS, and two target lesion revascularisations without stent thrombosis (MACE rate 4.0%). CONCLUSIONS: Neointimal strut coverage of the BFS was rapid and the BFS was shown to be clinically safe and effective.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Humanos , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica , Resultado do Tratamento
5.
JACC Cardiovasc Interv ; 10(18): 1832-1838, 2017 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-28935075

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the outcomes of the novel Fantom coronary bioresorbable scaffold at 6 months. BACKGROUND: The Fantom sirolimus-eluting bioresorbable scaffold incorporates a unique proprietary iodinated, polycarbonate copolymer of tyrosine analogs that is radiopaque, with thin struts (125 µm) that facilitate device delivery and precise target lesion treatment. METHODS: The 6-month outcomes and performance of the Fantom scaffold were evaluated in 117 patients with single de novo native coronary artery lesions of length ≤20 mm and reference vessel diameter 2.5 to 3.5 mm. The primary angiographic endpoint was mean late lumen loss at 6 months measured by quantitative coronary angiography. Procedural outcomes were categorized as short-term technical success, short-term procedural success, and clinical procedural success. The primary clinical endpoint was major adverse cardiac events at 6 months, the composite of cardiac death, myocardial infarction (MI), or clinically driven target lesion revascularization (TLR). RESULTS: Short-term technical success, short-term procedural success, and clinical procedural success were achieved in 96.6%, 99.1%, and 99.1% of patients, respectively. Mean 6-month in-stent late lumen loss was 0.25 ± 0.40 mm (n = 100). Binary restenosis was present in 2 patients (2.0%). Major adverse cardiac events within 6 months occurred in 3 patients (2.6%), including no deaths, 2 MIs, and 2 TLRs (1 patient had both an MI and TLR). Scaffold thrombosis occurred in 1 patient (0.9%). CONCLUSIONS: The clinical results from 117 patients enrolled in cohort A of the multicenter FANTOM II (Safety & Performance Study of the FANTOM Sirolimus-Eluting Bioresorbable Coronary Scaffold) study demonstrate favorable 6-month outcomes of this novel device in the treatment of noncomplex coronary artery disease.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
6.
J Am Coll Cardiol ; 45(8): 1180-5, 2005 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-15837246

RESUMO

OBJECTIVES: We sought to determine whether gender influences the results of paclitaxel-eluting stent implantation. BACKGROUND: The TAXUS-IV trial demonstrated the safety and effectiveness of the slow-release, polymer-based, paclitaxel-eluting TAXUS stent compared to bare-metal stents in patients undergoing elective coronary intervention. Whether these results are generalizable to women is not known. METHODS: A total of 1,314 patients with coronary lesions 10- to 28-mm long in 2.5- to 3.75-mm vessels were randomized to TAXUS stent versus bare-metal EXPRESS stents (Boston Scientific Corp., Natick, Massachusetts). Outcomes examined were stratified by gender. RESULTS: A total of 662 patients (including 187 women) were assigned to the TAXUS stent, and 652 (180 women) received the control stent. Women were older than men, and had more hypertension, diabetes, renal insufficiency, unstable angina, and heart failure, but less smoking. Among patients receiving the TAXUS stent, women compared with men had higher unadjusted one-year rates of target lesion revascularization (TLR) (7.6% vs. 3.2%, p = 0.03), though female gender was not an independent predictor of TLR (odds ratio [OR] = 1.72 [95% confidence interval (CI) 0.68 to 4.37], p = 0.25). Moreover, restenosis rates were similar in men and women treated with the TAXUS stent (8.6% vs. 7.6%, respectively, p = 0.80), as was late loss (0.22 vs. 0.23 mm, p = 0.90). Compared to control stents, treatment with the TAXUS stent in women resulted in a significant reduction in nine-month restenosis (8.6% vs. 29.2%, p = 0.0001) and one-year TLR (7.6% vs. 14.9%, p = 0.02). The only independent predictor of freedom from restenosis in women was randomization to the TAXUS stent (OR = 0.28 [95% CI 0.11 to 0.74], p = 0.01). CONCLUSIONS: The benefits of the paclitaxel-eluting stent in reducing clinical and angiographic restenosis are generalizable to women.


Assuntos
Antineoplásicos/administração & dosagem , Doença das Coronárias/terapia , Paclitaxel/administração & dosagem , Stents , Fatores Etários , Idoso , Angiografia Coronária , Reestenose Coronária/prevenção & controle , Feminino , Humanos , Masculino , Revascularização Miocárdica , Polímeros , Fatores Sexuais , Resultado do Tratamento
7.
Am J Cardiol ; 98(4): 443-6, 2006 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16893694

RESUMO

This report describes angiographic findings of the first-in-human evaluation of the Biolimus A9 drug-eluting stent (Biolimus stent) in the treatment of noncomplex coronary lesions. In total, 120 patients with 122 de novo coronary lesions (2.75- to 4.00-mm vessels, < or = 24-mm lesion length) were prospectively randomized in a 2:1 ratio to receive the Biolimus stent (n = 80, 82 lesions) or the control uncoated stent (n = 40). Baseline lesion and angiographic characteristics were similar between groups. At 6-month follow-up, late lumen loss was significantly decreased with the Biolimus stent in the stent (0.26 +/- 0.43 vs 0.74 +/- 0.45 mm, p < 0.001) and in the segment (0.14 +/- 0.45 vs 0.40 +/- 0.41 mm, p = 0.004). In-stent restenosis was 3.9% in the Biolimus stent group versus 7.7% in the control group (p = 0.40). There was no exaggerated hyperplasia at the proximal and/or distal edge of the stent.


Assuntos
Implante de Prótese Vascular/instrumentação , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Imunossupressores/uso terapêutico , Sirolimo/uso terapêutico , Stents , Estenose Coronária/cirurgia , Estudos de Viabilidade , Seguimentos , Humanos , Estudos Prospectivos , Sirolimo/análogos & derivados , Resultado do Tratamento
8.
Am J Cardiol ; 98(3): 370-4, 2006 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-16860026

RESUMO

Coronary artery perforation is a rare, but dreaded, complication of percutaneous coronary intervention. Conventional treatment, including reversal of anticoagulation and prolonged balloon inflation, is associated with a high incidence of death, Q-wave myocardial infarction, and emergency coronary bypass surgery. Although a number of case reports have demonstrated the feasibility of sealing coronary perforations with synthetic material-covered stent grafts, the efficacy of this treatment has not been reported in a large, multicenter series. We used a retrospective international registry to examine the outcomes of the polytetrafluoroethylene-coated JOSTENT coronary stent graft (CSG) in 41 cases of coronary perforations. Perforations were relatively severe: 16.7% Ellis grade 1, 54.2% grade 2, and 29.1% grade 3. Of the 41 patients, > 1/3 (n = 14) experienced life-threatening complications before stent graft implantation, including pericardial tamponade (12.2%), cardiogenic shock (9.8%), and cardiac arrest (2.4%). A total of 52 CSGs were used to treat the 41 perforations (mean 1.3 per lesion). All CSGs were placed successfully, with 92.9% of the perforations sealed completely and 7.1% partially. One patient developed abrupt vessel closure after CSG deployment, resulting in an overall procedure success rate of 96.4%. No in-hospital Q-wave myocardial infarctions, emergency coronary bypass surgeries, or deaths resulted. The CSG may be a reliable and highly effective treatment option for sealing coronary perforations complicating percutaneous coronary interventions.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Implante de Prótese Vascular/instrumentação , Materiais Revestidos Biocompatíveis , Doença das Coronárias/terapia , Vasos Coronários/lesões , Politetrafluoretileno , Stents , Idoso , Cineangiografia , Doença das Coronárias/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Ruptura
9.
Am J Cardiol ; 98(4): 464-9, 2006 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16893698

RESUMO

The everolimus-eluting stent (EES) has been shown to significantly decrease neointimal proliferation at 6 months compared with the bare metal stent (BMS) in patients with de novo coronary lesions. We report mid-term outcomes based on different vessel sizes in the combined FUTURE I and II trials. In the prospective, randomized, FUTURE I trial (single center) and expanded FUTURE II trial (multicenter), 106 patients (107 lesions) were randomized to EESs (n = 49 lesions) or BMSs (n = 58 lesions). Patients were categorized into 3 groups based on preprocedure reference diameter as assessed by quantitative coronary angiography (small vessel < 2.75 mm, medium vessel 2.75 to 3.25 mm, and large vessel > 3.25 mm). At 6-month follow-up, EESs decreased in-stent late lumen loss (decreased rate range of 78% to 94%), resulting in significantly larger minimum lumen area as assessed by intravascular ultrasound (increased range of 34% to 42%) compared with the BMS across all vessel sizes. There were no cases of in-stent restenosis with EESs at any vessel size but 8 cases with BMSs (5 in small vessels). No stent thrombosis, aneurysm formation, or late stent incomplete apposition was observed in any group. The EES appears to be effective for treatment of de novo coronary lesions in decreasing neointimal proliferation at 6-month follow-up compared with BMSs, regardless of vessel size.


Assuntos
Implante de Prótese Vascular/instrumentação , Materiais Revestidos Biocompatíveis , Reestenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Imunossupressores/uso terapêutico , Sirolimo/análogos & derivados , Stents , Idoso , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Everolimo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sirolimo/uso terapêutico , Resultado do Tratamento , Ultrassonografia de Intervenção
10.
Am J Cardiol ; 98(4): 436-42, 2006 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16893693

RESUMO

We investigated the fate of postprocedural incomplete stent apposition (ISA) after sirolimus-eluting stent (SES) implantation by evaluating long-term intravascular ultrasound findings in 168 consecutive patients (182 de novo lesions). Postprocedural ISA was defined as > or = 1 stent strut that was clearly separated from the vessel wall with evidence of blood speckle behind the strut without overlapping a side branch. After SES implantation, there were 61 ISA sites in 46 stents in 31 patients (23 at the proximal edge, 7 at the distal edge, and 31 within the stent body). There were no clinical, procedural, or intravascular ultrasound measurement differences between patients and lesions with versus without ISA. At follow-up, 15 acute ISA sites (25%) in 11 patients completely resolved and 40 sites (75%) in 20 patients persisted, although 32 of 46 persisting ISA sites (70%) decreased. There was a greater decrease in effective lumen area and a greater increase in peristent plaque area in the complete-resolution group than in the persistent-ISA group. No lesion developed stent thrombosis or in-stent restenosis (angiographic diameter stenosis > 50%). Six acute ISA sites were also associated with new, late acquired ISA, only 1 of which resulted in aneurysm formation. Although most ISAs after SES implantation do not resolve completely, the incidence of restenosis or thrombosis is not affected.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Materiais Revestidos Biocompatíveis , Estenose Coronária/diagnóstico por imagem , Imunossupressores/uso terapêutico , Sirolimo/uso terapêutico , Stents , Ultrassonografia de Intervenção/métodos , Doença Aguda , Implante de Prótese Vascular/instrumentação , Estenose Coronária/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Falha de Prótese
11.
JACC Cardiovasc Interv ; 9(1): 51-64, 2016 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-26762911

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the efficacy and long-term outcomes of a novel polymer/carrier-free drug-coated stent (DCS) in patients with de novo coronary lesions. BACKGROUND: The BioFreedom (BFD) DCS incorporates a low-profile, stainless-steel platform, with a surface that has been modified to create a selectively microstructured abluminal surface that allows adhesion and further release of Biolimus A9 (Biosensors Europe SA, Morges, Switzerland). METHODS: A total of 182 patients (183 lesions) were randomized into a 1:1:1 ratio for treatment with BFD "standard dose" (BFD) or BFD "low dose" (BFD-LD) versus first-generation paclitaxel-eluting stents (PES) at 4 sites in Germany. RESULTS: Baseline and procedural characteristics were well matched. At 4-month angiographic follow-up (Cohort 1, n = 75), in-stent late lumen loss (LLL) was significantly lower with BFD and BFD-LD versus PES (0.08 and 0.12 mm vs. 0.37 mm, respectively; p < 0.0001 for BFD vs. PES, and p = 0.002 for BFD-LD vs. PES). At 12 months (Cohort 2, n = 107), in-stent LLL (primary endpoint) was 0.17 mm in BFD versus 0.35 mm in PES (p = 0.001 for noninferiority; p = 0.11 for superiority); however, the BFD-LD (0.22 mm) did not reach noninferiority (p = 0.21). At 5 years (175 of 182), there were no significant differences in major adverse cardiac events (23.8%, 26.4%, and 20.3%) and clinically indicated target lesion revascularization (10.8%, 13.4%, and 10.2%) for BFD, BFD-LD, and PES, respectively; also, there was no definite/probable stent thrombosis reported. CONCLUSIONS: The BFD, but not the BFD-LD, demonstrated noninferiority versus PES in terms of in-stent LLL, a surrogate of neointimal hyperplasia, at 12-month follow-up. At 5 years, clinical event rates were similar, without occurrence of stent thrombosis in all groups. (BioFreedom FIM Clinical Trial; NCT01172119).


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/tratamento farmacológico , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Vasos Coronários/diagnóstico por imagem , Feminino , Alemanha , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Neointima , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Sirolimo/administração & dosagem , Aço Inoxidável , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento
12.
JACC Cardiovasc Interv ; 9(6): 565-74, 2016 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-27013155

RESUMO

OBJECTIVES: This study sought to report the late multimodality imaging and clinical outcomes of the novel poly-l-lactic-acid-based DESolve novolimus-eluting bioresorbable coronary scaffold for the treatment of de novo coronary lesions. BACKGROUND: Bioresorbable scaffolds are an alternative to drug-eluting metallic stents and provide temporary vascular scaffolding, which potentially may allow vessel restoration and reduce the risk of future adverse events. METHODS: Overall, 126 patients were enrolled at 13 international sites between November 2011 and June 2012. The primary endpoint was in-scaffold late lumen loss at 6 months. Major adverse cardiac events, the main safety endpoint, were defined as the composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. All patients underwent angiography at 6 months. Serial intravascular ultrasound and optical coherence tomography were performed in a subset of patients. RESULTS: The scaffold device success rate was 97% (n = 122 of 126), and procedural success was 100% (n = 122 of 122). The major adverse cardiac event rate was 3.3% (n = 4 of 122) at 6 months and 7.4% (n = 9 of 122) at 24 months, including 1 probable stent thrombosis within the first month. At 6-month angiographic follow-up, in-scaffold late lumen loss was 0.20 ± 0.32 mm. Paired intravascular ultrasound analysis demonstrated a significant increase in vessel, lumen and scaffold dimensions between post-procedure and 6-month follow-up, and strut-level optical coherence tomography analysis showed full strut coverage in 99 ± 1.7%. CONCLUSIONS: Our results showed favorable performance of the DESolve scaffold, effective inhibition of neointimal hyperplasia, and for the first time, early luminal and scaffold growth at 6 months with sustained efficacy and safety through 2 years. (Elixir Medical Clinical Evaluation of the DESolve Novolimus Eluting Bioresorbable Coronary Scaffold System-The DESolve Nx Trial; NCT02086045).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Macrolídeos/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Brasil , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Vasos Coronários/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Hiperplasia , Macrolídeos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Neointima , Nova Zelândia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
13.
EuroIntervention ; 12(12): 1498-1509, 2016 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-26448577

RESUMO

AIMS: Fully bioresorbable Absorb poly-L-lactic-acid (PLLA) scaffolds (Abbott Vascular, Santa Clara, CA, USA) are a novel approach for the treatment of coronary narrowing. Due to the translucency of the material (PLLA), the optical coherence tomography (OCT) measurement methods used in the ABSORB trials were unique but not applicable for permanent metallic stents. When the Absorb scaffold and metallic stents are compared in the context of randomised trials, it is challenging to compare the two devices using the conventional methods. The primary purpose of this report is to explain the biases in conventional methodologies applied for metallic stents and for PLLA scaffolds at baseline and follow-up, and to propose a new standard methodology that enables us to compare two different devices using an almost identical and methodological language. METHODS AND RESULTS: A consensus amongst multiple core labs and expert researchers of OCT was reached on a new standard OCT measurement methodology that enables us to compare these two different devices. In brief, the proposed OCT methods are summarised as follows. 1) Both endoluminal and abluminal scaffold/stent contours should be traced. 2) Consistently, endoluminal and abluminal incomplete stent apposition areas should be measured. 3) The area occupied by scaffold/stent struts should be quantified directly or virtually. 4) The strut area should be systematically excluded from the flow area as well as the neointimal area. 5) Additional information on the degree of embedment could be reported using the interpolated lumen contour. Interobserver variability of the proposed method was excellent (intraclass correlation 0.89-100). CONCLUSIONS: A standardised OCT measurement methodology is proposed. This should be implemented in ongoing and future trials comparing the Absorb scaffolds and metallic stents.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Tomografia de Coerência Óptica , Angiografia Coronária/métodos , Stents Farmacológicos/efeitos adversos , Everolimo/uso terapêutico , Seguimentos , Humanos , Intervenção Coronária Percutânea/métodos , Poliésteres , Desenho de Prótese , Tomografia de Coerência Óptica/métodos
14.
Cardiovasc Ther ; 33(6): 367-71, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26352896

RESUMO

AIMS: To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. METHODS: This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. RESULTS: After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. CONCLUSIONS: The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Brasil , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Trombose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
16.
EuroIntervention ; 9(4): 493-500, 2013 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-23965355

RESUMO

AIMS: We report the initial human evaluation of the novel BioMimeTM sirolimus-eluting stent (SES) (Meril Life Sciences Pvt. Ltd., Gujarat, India) with an ultra-thin stent platform (65 µm) and a biodegradable polymer for the treatment of de novo coronary lesions. METHODS AND RESULTS: The meriT-1 trial was a prospective, non-randomised, single-arm, single-centre, first-in-human evaluation of the safety, feasibility and performance of the BioMime SES. Lesion criteria included non-occlusive stenosis ≤ 19 mm in length located in native coronary vessels. Clinical follow-up (FU) was performed at 1, 8 and 12 months; all patients were assigned for angiographic FU at eight months. A total of 30 patients (30 lesions) were enrolled between March 2009 and February 2010. Mean age was 49.9 years, 30% were diabetics, and 36.7% had previous myocardial infarction (MI). Baseline median [25%, 75% interquartile range] lesion length, reference diameter and % diameter stenosis were 15.51 mm [12.74, 20.27], 2.94 mm [2.71, 3.34], and 80.5% [67.0%, 90.7%], respectively. Overall, there was one stent implanted per lesion and procedural success was 100%. At eight-month angiographic FU (26/30), median in-stent late lumen loss was 0.15 mm [0.09, 0.33]; also, there were no cases of binary restenosis within the treated segment. Clinical FU at 12 months (100%) demonstrated absence of MACE (cardiac death, MI and target lesion revascularisation) and stent thrombosis (ST). CONCLUSIONS: The novel BioMime SES demonstrated excellent performance in single coronary lesions including high procedural success and efficacy, as demonstrated by the relatively low late lumen loss (a surrogate of neointimal hyperplasia) at eight-month angiographic FU. Overall, there were no safety concerns in this preliminary evaluation including absence of MACE or ST up to 12 months.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/cirurgia , Stents Farmacológicos , Sirolimo/uso terapêutico , Adulto , Idoso , Reestenose Coronária/terapia , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Sirolimo/efeitos adversos , Resultado do Tratamento
17.
J Am Coll Cardiol ; 60(19): 1975-84, 2012 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-23103033

RESUMO

OBJECTIVES: This study sought to evaluate the potential utility of a novel polyethylene terephthalate micronet mesh-covered stent (MGuard) in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing percutaneous coronary intervention (PCI). BACKGROUND: Suboptimal myocardial reperfusion after PCI in STEMI is common and results in increased infarct size and mortality. The MGuard is a novel thin-strut metal stent with a polyethylene terephthalate micronet covering designed to trap and exclude thrombus and friable atheromatous debris to prevent distal embolization. METHODS: A total of 433 patients with STEMI presenting within 12 h of symptom onset undergoing PCI were randomized at 50 sites in 9 countries to the MGuard (n = 217) or commercially available bare metal or drug-eluting stents (n = 216). The primary endpoint was the rate of complete (≥70%) ST-segment resolution measured 60 to 90 min post-procedure. RESULTS: Baseline characteristics were well matched between the groups. The primary endpoint of post-procedure complete ST-segment resolution was significantly improved in patients randomized to the MGuard stent compared with control patients (57.8% vs. 44.7%; difference: 13.2%; 95% confidence interval: 3.1% to 23.3%; p = 0.008). By core laboratory analysis, the MGuard stent compared with control stents also resulted in superior rates of Thrombolysis In Myocardial Infarction 3 flow (91.7% vs. 82.9%, p = 0.006) with comparable rates of myocardial blush grade 2 or 3 (83.9% vs. 84.7%, p = 0.81). Mortality (0% vs. 1.9%, p = 0.06) and major adverse cardiac events (1.8% vs. 2.3%, p = 0.75) at 30 days were not significantly different between patients randomized to the MGuard stent and control stent, respectively. CONCLUSIONS: Among patients with acute STEMI undergoing emergent PCI, the MGuard micronet mesh-covered stent compared with conventional metal stents resulted in superior rates of epicardial coronary flow and complete ST-segment resolution. A larger randomized trial is warranted to determine whether these benefits result in reduced infarct size and/or improved clinical outcomes. (Safety and Efficacy Study of MGuard Stent After a Heart Attack [MASTER]; NCT01368471).


Assuntos
Angiografia Coronária , Stents Farmacológicos , Dispositivos de Proteção Embólica , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/instrumentação , Polietilenotereftalatos , Idoso , Trombose Coronária/prevenção & controle , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Complicações Pós-Operatórias , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
18.
EuroIntervention ; 7(11): 1301-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22433193

RESUMO

AIMS: To demonstrate the acute and early outcomes of the novel Nile PAX dedicated polymer-free paclitaxel-coated stents (Minvasys SAS, Gennevilliers, France) in the treatment of de novo coronary bifurcation lesions. METHODS AND RESULTS: The Nile PAX device incorporates a cobalt-chromium alloy with a side aperture in the mid-stent designed to optimise scaffold at the bifurcation carina and side branch (SB) ostium, while maintaining SB access during procedure. From December 2008 to February 2010, 101 patients were prospectively enrolled in a non-randomised, multicentre study. Lesion criteria were: vessel size 2.5-3.5 mm in the parent vessel (PV) and 2.0-3.0 mm in the SB, and lesion length <14 mm in the PV, and <5 mm in the SB. Mean age was 63 years, 29% had diabetes, LAD/Dg was involved in 80.4%, and 61.7% had significant involvement of both branches. The study stent was successfully attempted and implanted in 98%. SB received additional stent in 26% final kissing-balloon inflation was performed in 93% and lesion (angiographic) success was achieved in 98%. There was only one non-Q myocardial infarction during hospitalisation, and no additional events up to 30 days. CONCLUSIONS: Preliminary results of the prospective, non-randomised, multicentre BIPAX clinical trial demonstrated encouraging results with the novel Nile PAX bifurcation DES in the treatment of coronary bifurcation lesions, including high device and procedural success. Overall, there was only one major adverse cardiac event during hospitalisation, with no additional events up to 30 days follow-up. Long-term follow-up is warranted.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Moduladores de Tubulina/administração & dosagem
20.
JACC Cardiovasc Interv ; 3(2): 191-202, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20170877

RESUMO

OBJECTIVES: The aim of this study was to evaluate the novel CardioMind Sparrow (CMS) stent (CardioMind, Inc., Sunnyvale, California) against the Multi-Link Pixel (MLP) stent (Guidant Corp., Santa Clara, California) for small vessel percutaneous coronary intervention (PCI). BACKGROUND: The CMS consists of a guidewire-based, self-expandable, ultra-thin nitinol stent with smaller profile and improved flexibility and deliverability. The performance of this novel device against a standard balloon-expandable stent for small vessel PCI has not been determined. METHODS: Twenty-one patients were treated with the CMS and compared with 30 patients treated with MLP. Only single de novo lesions <14 mm in length, in native vessels of 2.0 to 2.5 mm were included. The primary goal was the comparison of quantitative coronary angiography lumen loss and intravascular ultrasound intimal hyperplasia (IH) formation between groups at 6 months. RESULTS: Clinical characteristics were similar between groups. The CMS cohort had smaller vessels (2.20 +/- 0.20 mm vs. 2.43 +/- 0.16 mm, p < 0.0001) and shorter lesions (10.86 +/- 3.19 mm vs. 13.12 +/- 2.79 mm, p = 0.0091). Six-month late loss was significantly lower among CMS cohort (0.73 +/- 0.57 mm vs. 1.11 +/- 0.72 mm, p = 0.038). By intravascular ultrasound, 6-month IH volume was similar between groups (1.45 +/- 0.46 mm(3)/mm vs. 1.65 +/- 1.02 mm(3)/mm, p = 0.50). However, CMS presented a mean 13.39% expansion of its volumes, resulting in a significantly lower percentage of IH volumetric obstruction (31.94 +/- 8.19% vs. 39.90 +/- 4.72%, p = 0.0005). CONCLUSIONS: Despite producing similar amounts of IH volume, the self-expanding CMS stent presented chronic expansion of its volumes, better accommodating the neoformed tissue and resulting in significantly lower late loss and percent of IH volumetric obstruction in comparison with the MLP stent.


Assuntos
Ligas/uso terapêutico , Angioplastia Coronária com Balão , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Stents , Ultrassonografia de Intervenção , Ligas/administração & dosagem , Angioplastia com Balão , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA