Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BMC Infect Dis ; 19(1): 632, 2019 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-31315573

RESUMO

BACKGROUND: Hepatitis B virus (HBV) testing in oral fluid samples may provide advantages in diagnosis, screening or prevalence studies, especially among individuals with venous access difficulties. This study aims to optimize one commercially available assay for detecting total anti-HBc marker in oral fluid samples and to evaluate its utility under real life conditions in different settings for the purposes of prevalence and diagnostic studies. METHODS: Oral fluid was collected using a Salivette device and some parameters were initially evaluated: type of elution buffer and sample volume. Thereafter, the utility of oral fluid samples for detection of anti-HBc was evaluated in real life conditions in which, 1296 individuals gave serum and oral fluid samples. All serum samples were submitted to commercial EIAs to detect total anti-HBc, according to the manufacturer's instructions and oral fluid samples according to previous optimization. RESULTS: In optimization evaluation, PBS/BSA 0.5% and 100 µL of oral fluid (volume was two-fold increased compared to serum in EIA) were chosen as transport buffer and sample volume. In the field study, anti-HBc was detected in 211 out of 1296 serum samples giving overall oral fluid sensitivity of 52.6% and specificity of 96%. Concordance was higher in ambulatory setting (67.7) compared to general population (31.8). Mean ± standard deviation values of optical density/cutoff (OD/CO) in serum samples were higher in false-negative oral fluid samples than those seen in true positive samples. Sensitivity was higher in those presenting active infection compared to anti-HBc isolate and past infection. Sensitivity also increased in the ambulatory group when HCV individuals were excluded. CONCLUSIONS: It was possible to optimize a commercial EIA for detecting anti-HBc in oral fluid samples and where the highest concordance was found in ambulatory settings and among individuals with active infection.


Assuntos
Anticorpos Anti-Hepatite B/análise , Hepatite B/diagnóstico , Técnicas Imunoenzimáticas/métodos , Saliva/virologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
2.
J Med Virol ; 89(8): 1435-1441, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28165155

RESUMO

The use of saliva and dried blood spots (DBS) could increase access to HCV diagnosis for high-risk populations, such as HIV-infected individuals, but the performance of these assays has not been well established in this group. This study aims to evaluate HIV status, particularly TCD4+ cell count and viral load, in the performance of anti-HCV testing using DBS and saliva. A total of 961 individuals classified as HCV+, HIV+, or HIV/HCV+, as well as negative controls, donated serum, DBS, and saliva samples for anti-HCV testing using a commercial enzyme immunoassay. Sample volume was modified for DBS and saliva, and an ROC curve was used for cut-off determination in saliva. Anti-HCV sensitivities were greater than 93% using DBS and saliva in the HCV+ group, while they were 83.3% and 95.6% for HCV/HIV+ individuals for DBS and saliva assays, respectively. Specificity varied from 91.7% to 100% using saliva and DBS in HIV monoinfected and control subjects. When only anti-HCV/HCV RNA+ serum samples, that is, true positives, were considered, the sensitivities were 98.3% and 100% for DBS and saliva, respectively, in the HCV+ group and 91.6% and 94.8% for DBS and saliva, respectively, in the HIV/HCV+ group. High absorbance values were observed among those presenting with HCV RNA in serum and low HIV viral load (less than 50 copies/mL). In conclusion, DBS and saliva samples could be used for anti-HCV detection, particularly to identify active HCV cases, but low sensitivity was observed for anti-HCV testing using DBS in the HIV/HCV+ group.


Assuntos
Sangue/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Infecções por HIV/complicações , Anticorpos Anti-Hepatite C/análise , Anticorpos Anti-Hepatite C/sangue , Hepatite C/diagnóstico , Saliva/imunologia , Adulto , Idoso , Contagem de Linfócito CD4 , Dessecação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Inquéritos e Questionários , Carga Viral
3.
J Clin Lab Anal ; 27(3): 186-94, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23440736

RESUMO

BACKGROUND: Oral fluid (OF) sample collection and stability for HBsAg detection are not fully established. This study aims to investigate the applicability of OF collectors and sample stability for Hepatitis B virus surface antigen detection. METHODS: Paired serum and OF samples were obtained from 191 individuals, and Chembio (Chembio Diagnostic System, USA) and Salivette (Sarstedt, Germany) devices were used for OF collection. Two HBsAg enzyme immunoassays (EIAs) were used (HBsAg One kit, Radim, Rome, Italy and ETI-MAK-4, DiaSorin, Vercelli, Italy) to determine the most efficient method according OF collector. Sample volume, incubation time, and cutoff (CO) value were evaluated. The stability of OF samples was determined under different environmental conditions. RESULTS: Chembio samples analyzed using DiaSorin EIA without modification of the manufacturer's instructions, demonstrated a sensitivity of 95.24% and a specificity of 100%. Salivette samples analyzed with Radim EIA with receiver operating characteristic (ROC) curve for calculating the CO showed a sensitivity of 78.26% and a specificity of 89.88%. HBsAg was detected in Chembio and Salivette samples under different environmental conditions, but the Chembio samples were the most stable. CONCLUSIONS: Both collectors can be used for HBsAg detection in OF samples, but some modifications of commercial EIAs should be incorporated for Salivette device. OF samples were reliably stable and could be stored for up to 90 days at 2-8°C.


Assuntos
Antígenos de Superfície da Hepatite B/isolamento & purificação , Hepatite B/epidemiologia , Saliva , Manejo de Espécimes/métodos , Adolescente , Adulto , Idoso , Brasil , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Feminino , Hepatite B/diagnóstico , Hepatite B/virologia , Antígenos de Superfície da Hepatite B/sangue , Antígenos de Superfície da Hepatite B/química , Humanos , Técnicas Imunoenzimáticas , Masculino , Pessoa de Meia-Idade , Prevalência , Curva ROC , Saliva/química , Saliva/virologia , Estudos Soroepidemiológicos , Manejo de Espécimes/instrumentação , Temperatura , Fatores de Tempo
4.
J Clin Lab Anal ; 25(2): 134-41, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21438008

RESUMO

In this study, a modified enzyme immunoassay (EIA) was evaluated for the Hepatitis B surface antigen (HBsAg) among whole saliva and oral fluid samples. Specimens were collected from 115 individuals who gave serum and oral fluid using Salivette (Sarstedt, Nümbrecht, Germany) and whole saliva. Saliva specimens were tested following a modified ELISA, and the results were compared with paired serum specimens that were tested according to the supplier's instructions. Transport buffer for the oral fluids, sample volume for assay, incubation period of sample with conjugate as well as cut-off values were evaluated to optimize the assay. The highest sensitivity and specificity were obtained by increasing the incubation of sample and conjugate to 16 hr and using the area under the receiver operating characteristic curve to calculate cut-off values. HBsAg was detected in 40 oral fluids and 44 whole saliva samples out of 47 paired positive serum specimens and not detected in 64 oral fluids and 63 whole saliva samples out of 68 matched negative sera samples by the ELISA assay. There was excellent agreement between the results for the serum and saliva specimens kappa value (κ): 0.80 for oral fluid and κ: 0.87 for whole saliva and there was excellent reproducibility. Using an optimized protocol, the sensitivities of whole saliva and oral fluid were 93.6 and 85.1%, respectively, whereas specificities of whole saliva and oral fluid were 92.6 and 94.1%, respectively. Our data showed a significant promise for the use of whole saliva and oral fluid together with the modified commercial EIA for Hepatitis B virus infection surveillance.


Assuntos
Antígenos de Superfície da Hepatite B/análise , Vírus da Hepatite B/isolamento & purificação , Hepatite B/diagnóstico , Saliva/virologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ensaio de Imunoadsorção Enzimática , Feminino , Hepatite B/imunologia , Vírus da Hepatite B/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
5.
World J Hepatol ; 13(4): 504-514, 2021 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-33959230

RESUMO

BACKGROUND: To achieve the elimination of hepatitis B and C, there is an urgent need to develop alternative strategies to increase the access of diagnosis, particularly among key populations such as people living with human immunodeficiency virus (HIV), individuals with coagulopathies and chronic kidney disease (CKD) patients. AIM: To evaluate the use of dried blood spot (DBS) in the detection of hepatitis B virus (HBV) and hepatitis C virus (HCV) markers. METHODS: A total of 430 individuals comprised of people living with HIV, coagulopathies and CKD provided paired serum and DBS samples. HBsAg, anti-HBc and anti-HCV were tested in those samples using a commercial electrochemiluminescence. Demographic and selected behavioral variables were evaluated to assess possible association with HBV and HCV positivity. RESULTS: Using DBS, HBsAg prevalence varied from 3.9% to 22.1%, anti-HBc rates varied from 25.5% to 45.6% and anti-HCV positivity ranged from 15.9% to 41.2% in key populations. Specificities of HBV and HCV tests using DBS varied from 88.9% to 100%. The HBsAg assay demonstrated the best performance in CKD and coagulopathy individuals and the anti-HCV test had a sensitivity and specificity of 100% in people living with HIV. Accuracy of HBV and HCV detection in DBS varied from 90.2% to 100%. In the CKD group, HBsAg positivity was associated with infrequent use of condoms, and anti-HBc positivity was associated with sharing nail cutters/razors/toothbrushes. Anti-HCV reactivity was positively associated with a history of transplantation and length of time using hemodialysis in both specimens. In people living with HIV, only the male gender was associated with anti-HBc positivity in serum and DBS. CONCLUSION: DBS with electrochemiluminescence are useful tools for the diagnosis and prevalence studies of hepatitis B and C among key populations and may increase the opportunity to foster prevention and treatment.

6.
J Virol Methods ; 247: 32-37, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28506632

RESUMO

Influence of HIV status in HBV markers detection in saliva and dried blood spots (DBS) was not well established. This study aims to evaluate the performance of optimized commercial immunoassay for identifying HBsAg and anti-HBc in saliva and DBS according HIV status. A sum of 535 individuals grouped as HIV+, HBV+, HIV/HBV+ and HIV/HBV- were recruited where 347 and 188 were included for HBsAg and anti-HBc evaluation, respectively. Serum, DBS collected in Whatman 903 paper and saliva obtained using salivette device were analyzed using EIA. Increased sample volume and ROC curve analysis for cut off determination were used for DBS and saliva testing. HBsAg detection in saliva and DBS exhibited sensitivities of 80.9% and 85.6% and specificities of 86.8% and 96.3%. Sensitivity of anti-HBc in saliva and DBS were 82.4% and 76.9% and specificities in saliva and DBS were 96.9% and 91.7%. Low sensitivities were observed for HBsAg (62%) and anti-HBc (47%) detection in saliva of HIV/HBV+ individuals. OD values were also lower for HBsAg detection in DBS and saliva of HIV/HBV+ individuals compared to their serum samples. Statistical significance was found for sensitivities in HBsAg detection between saliva and DBS demonstrating high sensitivity for DBS specimens. In conclusion, HIV status or antiretroviral treatment appears to interfere in the performance of HBsAg and anti-HBc detection in DBS and saliva samples using the adapted commercial EIA.


Assuntos
Sangue/virologia , Anticorpos Anti-Hepatite B/análise , Anticorpos Anti-Hepatite B/sangue , Antígenos de Superfície da Hepatite B/análise , Antígenos de Superfície da Hepatite B/sangue , Hepatite B/diagnóstico , Saliva/virologia , Dessecação , Infecções por HIV/complicações , Humanos , Técnicas Imunoenzimáticas , Sensibilidade e Especificidade , Manejo de Espécimes/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA