1.
Rev. bras. ortop ; 52(supl.1): 40-45, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-899219

RESUMO

Abstract Objective To radiographically evaluate the quality of cementation and implantation technique using a polished, triple-tapered femoral stem in total hip arthroplasty (THA). Method Retrospective study with radiographic evaluation of 86 hips in 83 patients who underwent to primary THA with the triple-tapered cemented femoral stem C-Stem (DePuy Orthopedics, Warsaw, Indiana). Cases with at least one-year of follow-up were included, and data related to preoperative, immediate postoperative, and late postoperative radiographic evolution were recorded. This study analyzed, among others, the proximal femoral anatomy, the quality of cementation as described by Barrack, and the implant positioning. Cementation was also evaluated and quantified in the Gruen zones with one-year of follow-up. Results The mean age was 62.85 years. Proximal femoral anatomical conformation was Dorr type A in 34 (39.53%) cases, type B in 52 (60.46%), and no type C cases were found. Five (5.81%) cases were defined as type A by Barrack's cementation classification system, 46 (56.49%) type B, 27 (31.40%) type C, and eight (9.30%) type D. The greatest cement mantle thickness was observed in zones four (15.53 mm) and 11 (15.64 mm), and the smallest in zone nine (3.51 mm). Positioning in varus was observed in eight (9.3%) cases, valgus in 25 (29%), forward deviation in two (5%), and backward deviation in 55 (63.95%). Conclusions The C-Stem femoral system presented satisfactory results related to cementation pattern, positioning, osteolysis, and stress shielding with regard to literature referring to double-tapered or triple-tapered models, demonstrating to be a safe method, with a predictable and reliable cementing pattern.


Resumo Objetivo Avaliar radiograficamente a qualidade da técnica de cimentação e implantação de hastes femorais polidas e tripla cunha em artroplastias totais do quadril (ATQ). Método Estudo retrospectivo com avaliação de radiografias de 86 quadris em 83 pacientes submetidos à ATQ com componente femoral cimentado polido em tripla cunha C-Stem (DePuy Orthopaedics, Varsóvia, Ind.). Incluímos casos com pelo menos um ano de seguimento, foram registrados dados relacionados à evolução radiográfica pré-operatória, pós-operatória imediata e pós-operatória tardia. Avaliamos, entre outros dados, a anatomia do fêmur, a qualidade da cimentação segundo descrito por Barrack e o posicionamento da haste. A cimentação também foi avaliada e quantificada em cada zona de Gruen com um ano de seguimento. Resultados A idade média foi de 62,85 anos. A conformação do fêmur proximal foi do tipo A de Dorr em 34 (39,53%) casos, tipo B em 52 (60,46%) e não foram observados casos do tipo C. Cinco (5,81%) casos foram definidos como tipo A segundo a classificação de cimentação de Barrack, 46 (56,49%) tipo B, 27 (31,40%) tipo C e oito (9,30%) tipo D. A maior espessura média do manto foi observada nas zonas 4 (15,53 mm) e 11 (15,64 mm), a menor foi na zona 9 (3,51 mm). Foi observado posicionamento em varo em oito (9,3%) casos e em valgo em 25 (29%). Conclusão A haste femoral C-Stem apresentou resultados satisfatórios quanto ao padrão de cimentação, posicionamento, à presença de osteólise e stress shielding, tanto em relação à literatura referente aos modelos em dupla cunha quanto referente ao mesmo modelo de implante, mostrou-se um método seguro e com padrão de cimentação previsível e confiável.


Assuntos
Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril , Cimentos Ósseos , Cimentação/métodos , Prótese de Quadril
2.
Rev Col Bras Cir ; 37(1): 58-63, 2010 Feb.
Artigo em Português | MEDLINE | ID: mdl-20414578

RESUMO

OBJECTIVE: This is an experimental study with the objective of analyses the increase of rigidity in synthetic tibia bones with external fixators, with single and double connecting rods and with stable and unstable fracture patterns. METHODS: The external fixators were used in the monoplanar, half pin configuration submitted to an axial compression load using the connecting bar in different patterns. Forty-eight similar models to the human tibia had been used. In all the models were left an interval of 0,5 cm between the fragments and were made cuts of 15 masculine and 45 masculine to simulate stable and unstable fracture patterns, respectively. The models had been divided in four groups in accordance with the cut (15 masculine and 45 masculine) and the number of metallic bars in assembly (1 and 2 bars). The study used the Instron testing machine which the models were submitted to the axial load until the fragments that were separated by a gap made full contact. RESULTS: The instability forces in the assembly with a double bar had been sufficiently superior to the forces with only one bar. It was still observed that the group with unstable fracture pattern and with only one connecting rod had a lesser variability compared with the other groups and presented more homogeneous results, with a minor average. CONCLUSION: The assembly with a double longitudinal connecting rod in the studied models is more stable than the others to stand compression load.


Assuntos
Força Compressiva , Fixadores Externos , Modelos Anatômicos , Poliuretanos , Tíbia , Fraturas da Tíbia/cirurgia , Desenho de Equipamento
3.
Rev. Col. Bras. Cir ; 37(1): 058-063, ene.-feb. 2010. ilus, graf
Artigo em Português | LILACS | ID: lil-554493

RESUMO

OBJETIVO: Analisar a resistência (rigidez) do sistema de fixação externa tubular uniplanar, com hastes de conexão única e dupla, com traços de fraturas estáveis e instáveis. MÉTODOS: Foram utilizados 48 modelos semelhantes à tíbia. Em todos foi deixado um intervalo de 0,5 cm entre os fragmentos e realizados cortes com angulações de 15º e 45º para simular fraturas estáveis e instáveis, respectivamente. Os modelos foram divididos em quatro grupos de acordo com o traço fraturário (15º e 45º) e o número de barras metálicas na montagem (1 e 2 barras). Os modelos de prova foram adaptados à uma máquina de testes Instron®, pelas suas extremidades, e submetidos à compressão axial até que os fragmentos tiveram contato total. Avaliou-se a força necessária para efetuar o completo contato dos fragmentos do modelo. RESULTADOS: As forças instabilizadoras na montagem do fixador com barra dupla foram bastante superiores às com barra única. Observou-se ainda que o grupo com barra única instável apresentou variabilidade muito menor que os demais grupos, ou seja, apresenta resultados mais homogêneos, além de ter apresentado a menor média. CONCLUSÃO: A montagem do fixador externo com uma haste longitudinal dupla nos modelos estudados é mais estável que as demais quando submetidas à uma força de compressão axial.


OBJECTIVE: This is an experimental study with the objective of analyses the increase of rigidity in synthetic tibia bones with external fixators, with single and double connecting rods and with stable and unstable fracture patterns. METHODS: The external fixators were used in the monoplanar, half pin configuration submitted to an axial compression load using the connecting bar in different patterns. Forty-eight similar models to the human tibia had been used. In all the models were left an interval of 0,5 cm between the fragments and were made cuts of 15º and 45º to simulate stable and unstable fracture patterns, respectively. The models had been divided in four groups in accordance with the cut (15º and 45º) and the number of metallic bars in assembly (1 and 2 bars). The study used the Instron® testing machine which the models were submitted to the axial load until the fragments that were separated by a gap made full contact. RESULTS: The instability forces in the assembly with a double bar had been sufficiently superior to the forces with only one bar. It was still observed that the group with unstable fracture pattern and with only one connecting rod had a lesser variability compared with the other groups and presented more homogeneous results, with a minor average. CONCLUSION: The assembly with a double longitudinal connecting rod in the studied models is more stable than the others to stand compression load.


Assuntos
Força Compressiva , Fixadores Externos , Modelos Anatômicos , Poliuretanos , Tíbia , Fraturas da Tíbia/cirurgia , Desenho de Equipamento