Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Clin Oral Implants Res ; 28(9): 1067-1073, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27393033

RESUMO

AIM: To evaluate by histopathological analysis the peri-implant bone inflammation degree, in certain time intervals (7, 14, 21 and 28 days), following mini-incision flapless and flap implant placement. MATERIAL AND METHODS: The experiment was conducted on four domestic pigs. Nine weeks prior to implant insertion, second and third mandibular premolars were extracted. Each animal received six implants in lower jaw. On one randomly chosen side of jaw flapless technique using mini-incision was performed, while on the other side implants were inserted after flap raising. After 7, 14, 21, and 28 days, the experimental animals were sacrificed. Following mandibular resection and decalcification, the samples for histopathological analysis of the peri-implant bone were obtained in the empty implant bed area, from the buccal side of the mandible, adjacent to implant neck region and parallel to crestal edge of implant bed. The degree of inflammatory response of the peri-implant bone was estimated through ordinal scores from 0 to 2. RESULTS: Seven days after the surgery all samples in the flap group had score 2 indicating high inflammation degree, in contrast to lower inflammatory reaction in flapless group. On the 14th and 21st postoperative day decreasing of inflammation degree was noted in all samples of the flapless group (score 1), while in flap group samples presented scores 1 and 2. Twenty-eight days after the implant placement, further reduction of inflammation in the flapless group (33% of samples had score 0) was observed. CONCLUSION: Flapless technique in comparison to conventional flap procedure minimizes postoperative bone inflammatory reactions.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Mandíbula/patologia , Peri-Implantite/patologia , Retalhos Cirúrgicos , Animais , Feminino , Sus scrofa
2.
Clin Oral Implants Res ; 28(10): 1241-1247, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27539149

RESUMO

OBJECTIVES: To compare the peri-implant bone healing between TiZr implants with hydrophilic SLActive and hydrophobic SLA implant surface in patients receiving anticoagulants, to assess the implant survival and success rate, as well as to evaluate whether small-diameter TiZr implants could be used in patients on OAT in order to avoid augmentation procedures. MATERIAL AND METHODS: A total of 80 small-diameter tissue-level TiZr implants with SLActive and SLA surfaces were placed in 20 anticoagulated patients, following the "split-mouth" study design. Implant stability was measured up to the third postoperative month by resonance frequency measurements (RFA). One-year implant survival and success rate were evaluated. RESULTS: After one year, 100% implant survival and success rate were observed. A significant decrease in ISQ comparing to baseline values was noted in the SLActive group from the first postoperative week, and in the SLA group, from the 3rd week after the surgery. In both groups, a statistically significant decline in ISQ was observed between second and third postoperative week. No significant differences in ISQ values between SLActive and SLA implants were noted, at any time point. CONCLUSIONS: Titanium-zirconium small-diameter implants with SLActive and SLA surface predictably achieve and maintain adequate bone tissue integration in patients receiving anticoagulants. OAT appears to influence the bone healing events resulting in lower ISQ in the end of 3-month period in comparison with baseline values, although without compromising implant stability.


Assuntos
Anticoagulantes/farmacologia , Implantes Dentários , Interações Hidrofóbicas e Hidrofílicas , Osseointegração/efeitos dos fármacos , Ferida Cirúrgica , Cicatrização/efeitos dos fármacos , Condicionamento Ácido do Dente , Idoso , Planejamento de Prótese Dentária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Propriedades de Superfície/efeitos dos fármacos , Titânio , Zircônio
3.
Clin Oral Implants Res ; 24(7): 798-805, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22469169

RESUMO

OBJECTIVES: The study aimed to investigate the effect of surgical technique, implant macrodesign and insertion torque on bone temperature changes during implant placement. MATERIAL AND METHODS: In the in vitro study, 144 self-tapping (blueSKY(®) 4 × 10 mm; Bredent) and 144 non-self-tapping (Standard implant(®) 4.1 × 10 mm; Straumann) were placed in osteotomies prepared in pig ribs by lateral bone condensing or bone drilling techniques. The maximum insertion torque values of 30, 35 and 40 Ncm were used. Real-time bone temperature measurement during implant placement was performed by three thermocouples positioned vertically, in tripod configuration around every osteotomy, at a distance of 5 mm from it and at depths of 1, 5 and 10 mm. Data were analysed using Kruskal-Wallis, Mann-Whitney U-tests and Regression analysis. RESULTS: Significant predictor of bone temperature at the osteotomy depth of 1 mm was insertion torque (P = 0.003) and at the depth of 10-mm implant macrodesign (P = 0.029), while no significant predictor at depth of 5 mm was identified (P > 0.05). Higher insertion torque values as well as non-self-tapping implant macrodesign were related to higher temperatures. Implant placement in sites prepared by bone drilling induced significantly higher temperature increase (P = 0.021) compared with bone condensing sites at the depth of 5 mm, while no significant difference was recorded at other depths. Compared with 30 Ncm, insertion torque values of 35 and 40 Ncm produced significantly higher temperature increase (P = 0.005; P = 0.003, respectively) at the depth of 1 mm. There was no significant difference in temperature change induced by 35 and 40 Ncm, neither by implant macrodesign at all investigated depths (P > 0.05). CONCLUSIONS: Placement of self-tapping implants with low insertion torque into sites prepared by lateral bone condensing technique might be advantageous in terms of thermal effect on bone.


Assuntos
Temperatura Corporal/fisiologia , Densidade Óssea/fisiologia , Implantação Dentária Endóssea/métodos , Implantes Dentários , Planejamento de Prótese Dentária , Animais , Implantação Dentária Endóssea/instrumentação , Temperatura Alta , Masculino , Modelos Animais , Osteotomia/instrumentação , Osteotomia/métodos , Distribuição Aleatória , Costelas/cirurgia , Suínos , Termômetros , Torque
4.
Nanomaterials (Basel) ; 12(14)2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-35889677

RESUMO

The surface quality of denture base resins allows for easy colonization by microorganisms including Candida albicans and Staphylococcus aureus, which cause major diseases of the oral cavity such as denture stomatitis. The widespread use of silver nanoparticles (AgNPs) in various fields of medicine has led to research of their possible application in dentistry, mostly in the prevention of bacterial adhesion, proliferation, and biofilm formation. The aim of the study was to synthesize cold and heat-curing denture base resins modified with AgNPs and AgCl, and evaluate the potential of the modified resins to reduce the growth of C. albicans and S.aureus. The produced material was characterized by Fourier transform infrared spectroscopy (FTIR). The antimicrobial potential of the modified material was demonstrated by the disc-diffusion method, microdilution method, and a modified microdilution method (i.e., disk-diffusion method in broth with viable counting). Spectroscopy confirmed the incorporation of biocidal materials into the structure of the denture base resins. The AgCl and AgNPs modified resins showed an antimicrobial effect. The significance of the study is in the potential therapeutic effects of the modified materials for prevention and threating staphylococci and candida in elderly patients, who are in most cases denture wearers and have a greater susceptibility to develop opportunistic infections. Modified denture base resins can significantly reduce the presence of infection at the point of contact between the denture and the mucous membrane of the prosthetic restoration. Biological tests of modified denture base resins will follow.

5.
Clin Implant Dent Relat Res ; 17(5): 1004-13, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24461229

RESUMO

PURPOSES: The primary aim of the study was to investigate a 1-year success rate of early-loaded bone level implants with a chemically modified sand-blasted, large grit, acid-etched surface (SLActive®, Institut Straumann AG, Basel, Switzerland) in the posterior maxilla. Secondary objectives included stability of these implants and peri-implant bone level. MATERIALS AND METHODS: Bone level® implants (Institut Straumann AG) inserted into premolar and/or molar maxillary sites were loaded after 6 weeks of healing. The implants were monitored for 1 year using the following outcome measures: implant success, primary and secondary stability, and peri-implant bone level. RESULTS: Out of 37 implants placed in 13 patients, 36 reached sufficient stability and were early loaded, whereas one underwent a delayed loading protocol. One-year success rate of early-loaded implants was 100%. Implant stability at baseline was 71.7 ± 5. 6 to be steadily increased thereafter up to 1 year (80.3 ± 3.3), except at 2 weeks when a nonsignificant decrease was noticed (71.9 ± 3.9). Continuous and significant bone loss was observed, reaching 0.4 ± 0.1 mm in the first postoperative year. CONCLUSION: Bone level implants with the SLActive surface placed into low-density bone and loaded after 6 weeks of healing can predictably achieve and maintain a successful tissue integration.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Maxila/cirurgia , Osseointegração , Adulto , Prótese Dentária , Feminino , Humanos , Masculino , Maxila/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA