Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int Wound J ; 21(1): e14609, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38272798

RESUMO

Postoperative wound infections (PWIs), a subtype of surgical site infections, are a significant concern for patients undergoing caesarean sections (C-sections). Understanding risk factors and pathogen profiles can greatly assist in early diagnosis and effective treatment. This study aimed to identify risk factors and analyse the pathogenic landscape contributing to PWIs in C-sections. A nested case-control study was carried out, utilising stringent criteria for case selection and control matching. Diagnostic criteria for surgical site infections included both clinical and microbiological parameters. Risk variables examined included patient age, Body Mass Index, duration of surgery and several other clinical indicators. Microbiological analysis was performed using the BD Phoenix-100 Automated Bacterial Identification System. Statistical analyses were conducted using SPSS version 26.0, and risk factors were evaluated through both univariate and multivariate analyses. A total of 50 patients, aged between 20 and 45 years (mean age 26.3 ± 5.6), developed PWIs following C-sections. The study revealed a temporal distribution and various clinical indicators of PWIs, including elevated white blood cell count and C-reactive protein levels. Gram-negative bacteria were found to be more prevalent at 57.4%. Notable pathogens included Pseudomonas aeruginosa and Acinetobacter baumannii. Antimicrobial resistance patterns were also identified, highlighting the need for a targeted antibiotic approach. Increased infection risks were linked to lack of prophylactic antibiotics, absence of preoperative povidone-iodine antisepsis, operations over an hour, anaemia, amniotic fluid contamination, diabetes, GTI, premature rupture of membranes and white blood cells counts above 10 × 109 /L. The study provides critical insights into the risk factors and microbial agents contributing to PWIs following C-sections. Our findings emphasise the importance of early diagnosis through clinical and laboratory parameters, as well as the need for constant surveillance and reassessment of antibiotic stewardship programs.


Assuntos
Cesárea , Infecção da Ferida Cirúrgica , Humanos , Feminino , Gravidez , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/epidemiologia , Cesárea/efeitos adversos , Estudos de Casos e Controles , Povidona-Iodo/uso terapêutico , Antibacterianos/uso terapêutico , Fatores de Risco
2.
Transfusion ; 63(1): 125-133, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36342237

RESUMO

BACKGROUND: Acute normovolemic hemodilution (ANH) is one of the important techniques predominantly used in cardiac, hepatic, and vascular surgery for decreasing allogeneic blood transfusion. However, the effect of ANH in orthognathic surgery has been rarely studied. Therefore, this study aims to assess the ANH-mediated reduction in the allogeneic red blood cell transfusion for orthognathic surgery patients. STUDY DESIGN AND METHODS: In this single-center study, 18-80 years old patients were recruited. Patients with hemoglobin ≥11 g/dL and normal coagulation function were randomly divided into ANH or standard treatment group. RESULTS: Ninety six patients underwent ANH, and 101 patients received standard treatment. No differences in demographic or major pre-operative characteristics were observed between the two groups. One patient in the ANH and three patients in the standard treatment group received allogeneic blood [3(2.97%) vs. 1(1.16%), control vs. ANH, p = .395]. Multivariate logistic regression analysis revealed that ANH treatment was not associated with transfusion of allogeneic blood (p = .763). After retransfusing autologous blood, PT and APTT in the ANH group significantly increased compared to standard treatment group (PT: -1.73 ± 1.09 vs. -2.15 ± 1.06, p = .035; APTT: -6.39 ± 5.76 vs. -8.16 ± 5.70, p = .031; control vs. ANH). No significant differences between the two groups were observed for changes in coagulation parameters at first postoperative day. However, platelet counts in the ANH group decreased compared to the standard group. No significant difference in major adverse outcomes was observed between the two groups. CONCLUSION: ANH did not reduce the incidence of allogeneic transfusion in patients undergoing orthognathic surgery.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Cirurgia Ortognática , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Hemodiluição/efeitos adversos , Hemodiluição/métodos , Transfusão de Sangue , Coagulação Sanguínea
3.
Macromol Rapid Commun ; 44(11): e2200778, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36404104

RESUMO

Covalent organic frameworks (COFs) are a type of crystalline porous polymers that possess ordered structures and eternal pores. Because of their unique structural characteristics and diverse functional groups, COFs have been used in various application fields, such as adsorption, catalysis, separation, ion conduction, and energy storage. Among COFs, the fluorine-containing COFs (fCOFs) have been developed for special applications by virtue of special physical and chemical properties resulting from fluorine element, which is a nonmetallic halogen element and possesses strong electronegativity. In the organic chemistry field, introducing fluorine into chemicals enables those chemicals to exhibit many interesting properties, and fluorine chemistry increasingly plays an important role in the history of chemical development. The introduction of fluorine in COFs can enhance the crystallinity, porosity, and stability of COFs, making COFs having superior performances and some new applications. In this review, the synthesis and application of fCOFs are systematically summarized. The application involves photocatalytic production of hydrogen peroxide, photocatalytic water splitting, electrocatalytic CO2 reduction, adsorption for different substances (H2 , pesticides, per-/polyfluoroalkyl substances, polybrominated diphenyl ethers, bisphenols, and positively charged organic dye molecules), oil-water separation, energy storage (e.g., zinc-ion batteries, lithium-sulfur batteries), and proton conduction. Perspectives of remaining challenges and possible directions for fCOFs are also discussed.


Assuntos
Flúor , Estruturas Metalorgânicas , Halogênios , Polímeros
4.
Ann Hum Biol ; 48(1): 23-29, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32657156

RESUMO

AIMS: To measure the number of days of enamel formation between periodic striae of Retzius growth lines, the Retzius periodicity (RP), and to compare this multi-day, or multidien rhythm, to body height and weight among people from Beijing, China and Lhasa, Tibet/China. SUBJECTS AND METHODS: Subjects requiring dental extractions from clinics in Beijing, China (N = 338) and Lhasa, Tibet/China (N = 227) provided a tooth and body size information. Multiple observers examined histological sections of the teeth and recorded RP. RP values were statistically compared to body height and weight. RESULTS: In Beijing and Lhasa samples, respectively, average height was 166.38 and 165.70 cm, average weight was 59.53 and 66.53 kg, and average RP was 7.47 and 7.69 d. Statistically significant differences were found between Beijing and Lhasa weight and RP means. Correlations for height and weight against RP were significant, but only comparatively strong for height. CONCLUSIONS: Supporting the negative correlation presented in previous studies, RP is negatively associated with height and weight among a large intraspecific sample of people from Beijing and Lhasa. RP represents a metabolic-mediated multidien biological timing mechanism responsible for the rate of cell proliferation and maintenance of the body.


Assuntos
Tamanho Corporal , Peso Corporal , Esmalte Dentário/crescimento & desenvolvimento , Adulto , Idoso , Idoso de 80 Anos ou mais , Pequim , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Periodicidade , Tibet , Adulto Jovem
5.
J Prosthet Dent ; 125(3): 544.e1-544.e8, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33243474

RESUMO

STATEMENT OF PROBLEM: Information on the bond strength of milled polymethyl methacrylate interim restorations when relined with chairside reline materials is lacking. PURPOSE: The purpose of this in vitro study was to measure the shear bond strength of various combinations of 3 different chairside reline materials bonded to milled polymethyl methacrylate blocks with 3 different types of surface treatments. MATERIALS AND METHODS: Uniform blocks (10×10×22 mm) were milled from tooth-colored polymethyl methacrylate disks (Vivid PMMA; Pearson Dental Supply Co). The surface treatments tested were airborne-particle abrasion with 50-µm particle size aluminosilicate, application of acrylic resin monomer (Jet Liquid; Lang Dental Manufacturing Co) for 180 seconds, and airborne-particle abrasion with monomer application. The control groups were blocks with no surface treatment. The chairside reline materials tested were Jet acrylic resin (Jet Powder; Lang Dental Manufacturing Co), bis-acryl resin (Integrity; Dentsply Sirona), and flowable composite resin (Reveal; Bisco). All materials were applied through a Ø1.5×3-mm bonding ring. Ten specimens for each of the 12 groups were tested in a universal testing machine. Load was applied at a crosshead speed of 1 mm/min. Fracture surfaces were then analyzed for cohesive versus adhesive or mixed failure. Data were analyzed using 2-way ANOVA and Tukey-Kramer post hoc analysis (α=.05). RESULTS: The mean shear bond strength values ranged from 1.77 ±0.79 MPa to 28.49 ±5.75 MPa. ANOVA revealed that reline material (P<.05), surface treatment (P<.05), and their interactions (P<.05) significantly affected the shear bond strength among the experimental groups. The strongest combination was Jet acrylic resin applied on specimens treated with airborne-particle abrasion and monomer. All 3 failure modalities (adhesive, cohesive, and mixed modes) were observed. CONCLUSIONS: Of the materials tested, the most reliable material to bond to milled polymethyl methacrylate was Jet acrylic resin, and the bond strength values were increased substantially when the milled polymethyl methacrylate surface was airborne-particle abraded and monomer was applied.


Assuntos
Colagem Dentária , Polimetil Metacrilato , Óxido de Alumínio , Coroas , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície
6.
Anal Chem ; 92(22): 15079-15086, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33118803

RESUMO

Redox homeostasis between hypochlorous acid (HClO/ClO-) and ascorbic acid (AA) significantly impacts many physiological and pathological processes. Herein, we report a new electrochemical sensor for the simultaneous determination of HClO and AA in body fluids. We first coated a carbon fiber microelectrode (CFME) with a three-dimensional nanocomposite consisting of graphene oxide (GO) and carbon nanotubes (CNTs) to fabricate the CFME/GO-CNT electrode. After the electrochemical reduction of GO (ERGO), we integrated a latent 1-(3,7-bis(dimethylamino)-10H-phenothiazin-10-yl)-2-methylpropan-1-one (MBS) electrochemical molecular recognition probe to monitor HClO and employed anthraquinone (AQ) as an internal reference. The compact CFME/ERGO-CNT/AQ + MBS sensor enabled the accurate and simultaneous measurement of HClO and AA with excellent selectivity and sensitivity. Measurements were highly reproducible, and the sensor was stable and exceptionally biocompatible. We successfully detected changes in the redox cycles of HClO and AA in human body fluids. This sensor is a significant advance for the investigation of reactions involved in cellular redox regulation. More importantly, we have devised a strategy for the design and construction of ratiometric electrochemical biosensors for the simultaneous determination of various bioactive species.


Assuntos
Ácido Ascórbico/análise , Líquidos Corporais/química , Eletroquímica/instrumentação , Ácido Hipocloroso/análise , Ácido Ascórbico/química , Fibra de Carbono/química , Grafite/química , Humanos , Ácido Hipocloroso/química , Limite de Detecção , Oxirredução , Fatores de Tempo
7.
Biomacromolecules ; 20(3): 1455-1463, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-30764611

RESUMO

Nonconjugated red fluorescent polymers have been increasingly studied to improve the biocompatibility and penetration depth over conventional fluorescent materials. However, the accessibility of such polymers remains challenging due to the scarcity of nonconjugated fluorophores and lacking relevant mechanism of red-shifted fluorescence. Herein, we discovered that the combination of hydrogen bonding and π-π stacking interactions provides nonconjugated poly(amide-imide) with a large bathochromic shift (>100 nm) from blue-green fluorescence to red emission. The amphiphilic PEGylated poly(amide-imide) derived from in situ PEGylation self-assembled into nanovesicles in water, which isolated the aminosuccinimide fluorophore from the solvents and suppressed the hydrogen bonds formation between aminosuccinimide fluorophores and water. Therefore, the fluorescence of PEGylated poly(amide-imide) in water was soundly retained. Furthermore, the strong hydrogen bonding and hydrophobic interactions with water provided PEGylated poly(amide-imide) with a reversible thermoresponsiveness and presented a concentration-dependent behavior. Finally, accompanied by the excellent biostability and photostability, PEGylated poly(amide-imide) exhibited as a good candidate for cell imaging.


Assuntos
Amidas/química , Corantes Fluorescentes/química , Imidas/química , Polímeros/química , Fluorescência , Ligação de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas
8.
Analyst ; 144(21): 6432-6437, 2019 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-31584576

RESUMO

An electrochemical platform was proposed for highly sensitive and selective analysis of sialic acid based on molecularly imprinted polymers (MIPs), which were electropolymerized with the monomer molecules of 3-aminophenylboronic acid (ABA) on a carbon cloth (CC) electrode in the presence of template molecules. The fabricated sensor, named the PABA/CC-based MIP electrode, could be used for the detection of sialic acid because the reversible and covalent boronic acid-diol binding was sensitive to the electrochemical potential of the prepared sensor. The utilization of a CC film as the substrate could improve the sensitivity due to its good electrical conductivity and large surface area. Under the optimized conditions, a good relationship between the change in potential and the concentration of sialic acid was obtained in the range from 40 µM to 440 µM with a detection limit of 0.5 µM. The resulting MIP sensor also displayed good selectivity, reproducibility and stability. Moreover, this sensor was successfully applied for the evaluation of the sialic acid level in infant formulas.


Assuntos
Ácidos Borônicos/química , Carbono , Impressão Molecular , Ácido N-Acetilneuramínico/análise , Polímeros/síntese química , Potenciometria/instrumentação , Têxteis , Ácido 4-Aminobenzoico/química , Humanos , Concentração de Íons de Hidrogênio , Lactente , Fórmulas Infantis/química , Fenômenos Mecânicos , Polímeros/química
9.
Muscle Nerve ; 57(5): 859-862, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29236290

RESUMO

INTRODUCTION: Mutations in gap junction protein beta 1 (GJB1) on the X chromosome represent one of the most common causes of hereditary neuropathy. We assessed manifestations associated with a rare 3' untranslated region mutation (UTR) of GJB1 in a large family with X-linked Charcot-Marie-Tooth disease (CMTX). METHODS: Clinical, electrophysiological, and molecular genetic analyses were performed on an 8-generation family with CMTX. RESULTS: There were 22 affected males and 19 symptomatic females, including an 83-year-old woman followed for 40 years. Electrophysiological studies showed a primarily axonal neuropathy. The c.*15C>T mutation in the GJB1 3' UTR was identified in 4 branches of the family with a log of odds (LOD) of 4.91. This created a BstE II enzyme recognition site that enabled detection by restriction digestion. DISCUSSION: The c.*15C>T mutation in the GJB1 3' UTR segregates with CMTX1 in 8 generations. Penetrance in males and females is essentially complete. A straightforward genetic method to detect this mutation is described. Muscle Nerve 57: 859-862, 2018.


Assuntos
Regiões 3' não Traduzidas/genética , Doença de Charcot-Marie-Tooth/genética , Conexinas/genética , Saúde da Família , Mutação/genética , Adolescente , Adulto , Doença de Charcot-Marie-Tooth/fisiopatologia , Criança , Feminino , Perfilação da Expressão Gênica , Testes Genéticos , Genótipo , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Análise de Sequência com Séries de Oligonucleotídeos , Proteína beta-1 de Junções Comunicantes
10.
Ann Bot ; 121(2): 255-266, 2018 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-29267935

RESUMO

Background and Aims: To understand the link between species diversity and phenotype developmental evolution is an important issue in evolutionary biology. Yarrows in the genus Achillea (Asteraceae) show a great diversity in leaf serrate or pinnate dissection patterns. In Arabidopsis thaliana, the development of leaf serration requires the activity of the transcription factor CUC2. Does this regulator also work for leaf dissections of the Asteraceae plants? If so, how do the conserved regulatory 'tools' work differently to produce diverse leaf forms? Methods: Seedling leaf morphology was observed, and morphogenesis of leaf serration or lobes was examined by scanning electron microscopy (SEM). NAM genes, orthologues of arabidopsis CUC2, were isolated from A. acuminata with serrate leaves and A. asiatica with three-pinnatisect leaves, respectively. By means of whole-mount in situ mRNA hybridization and two quantitative gene expression assays, the droplet digital PCR (ddPCR) and quantitative real-time PCR (qPCR), expression patterns of the NAM genes during leaf dissection development were checked in both species for comparison. Key Results: For both species, the development of leaf dissection initiated when a leaf blade was about 300-400 µm long. In A. acuminata, in situ hybridization showed NAM expression signals at leaf margins where teeth are growing, or later on, in the sinuses of the teeth, whilst in A. asiatica, hybridization signals appear not only on leaf margins but further on the margins of leaf lobes. Both ddPCR and qPCR revealed a continuous decline of AacNAM expression from the early to the late developmental stages of a single leaf of A. acuminata, whereas a relatively long maintenance and fluctuation of AasNAM expression was seen in a leaf of A. asiatica. Conclusions: Differential spatiotemporal patterns of NAM expression were found between the two yarrow species during development of leaf dissection. This study provides the first evidence for NAM activity in the development of leaf dissection of the Asteraceae plants, and demonstrates that leaf form diversity is correlated to the altered NAM expression dynamic.


Assuntos
Achillea/anatomia & histologia , Genes de Plantas/fisiologia , Folhas de Planta/anatomia & histologia , Achillea/genética , Achillea/ultraestrutura , Passeio de Cromossomo , Regulação da Expressão Gênica de Plantas , Genes de Plantas/genética , Hibridização In Situ , Microscopia Eletrônica de Varredura , Filogenia , Folhas de Planta/genética , Folhas de Planta/ultraestrutura , Proteínas de Plantas/genética , Proteínas de Plantas/fisiologia , Reação em Cadeia da Polimerase em Tempo Real , Plântula/anatomia & histologia , Plântula/ultraestrutura , Fatores de Transcrição/genética , Fatores de Transcrição/fisiologia
11.
J Biomech Eng ; 139(12)2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28816344

RESUMO

The method used in biomechanical modeling for finite element method (FEM) analysis needs to deliver accurate results. There are currently two solutions used in FEM modeling for biomedical model of human bone from computerized tomography (CT) images: one is based on a triangular mesh and the other is based on the parametric surface model and is more popular in practice. The outline and modeling procedures for the two solutions are compared and analyzed. Using a mandibular bone as an example, several key modeling steps are then discussed in detail, and the FEM calculation was conducted. Numerical calculation results based on the models derived from the two methods, including stress, strain, and displacement, are compared and evaluated in relation to accuracy and validity. Moreover, a comprehensive comparison of the two solutions is listed. The parametric surface based method is more helpful when using powerful design tools in computer-aided design (CAD) software, but the triangular mesh based method is more robust and efficient.


Assuntos
Análise de Elementos Finitos , Mandíbula , Fenômenos Mecânicos , Fenômenos Biomecânicos , Imageamento Tridimensional , Mandíbula/diagnóstico por imagem , Mandíbula/fisiologia , Amplitude de Movimento Articular , Tomografia Computadorizada por Raios X
12.
Photochem Photobiol Sci ; 15(2): 181-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26787048

RESUMO

A facile method for in situ fabrication of three-dimensional gold nanoparticle micropatterns in a cell-resistant polyethylene glycol hydrogel has been developed by combining photochemical synthesis of gold nanoparticles with photolithography technology. The gold nanoparticle micropatterns were further bio-modified with cell integrated polypeptide NcysBRGD based on a gold-thiol bond to improve cell behaviors. Primary cell tests showed that NcysBRGD can enhance cell adhesion very well on the surface of gold nanoparticle micropatterns.


Assuntos
Ouro/química , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Nanopartículas Metálicas/química , Peptídeos/química , Sequência de Aminoácidos , Materiais Biocompatíveis/química , Adesão Celular , Desenho de Equipamento , Células HeLa , Humanos , Nanopartículas Metálicas/ultraestrutura , Microtecnologia , Dados de Sequência Molecular , Compostos de Sulfidrila/química , Análise Serial de Tecidos/instrumentação
13.
Soft Matter ; 11(30): 6029-36, 2015 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-26132425

RESUMO

Biocompatible and degradable injectable materials prepared via bioorthogonal reactions are highly promising for biomedical applications because they can be formed in situ and administered in a minimally invasive way. In this work, a PEG-based injectable hydrogel was fabricated via a copper-free, strain-promoted azide-alkyne cycloaddition (SPAAC) click chemistry. Azide and cyclooctyne moieties on the PEG backbones underwent a rapid click reaction to trigger the formation of the hydrogel within several minutes. Resulting from the introduction of ester groups into the cross-linked network, the hydrogel presented pH-dependent hydrolysis and biological fast degradability. Good biocompatibility of the hydrogel was verified by in vitro cytotoxicity assay and in vivo studies. The hydrogel formed in situ after subcutaneously injecting the gel precursors into Kungming (KM) mice. The implanted hydrogel caused a mild inflammatory response in vivo, and the surrounding tissues fully recovered a week after the injection. The injectable and fast-degradable hydrogel fabricated by the bioorthogonal click reaction may be useful as biomaterials such as embolic agents for interventional therapy.


Assuntos
Plásticos Biodegradáveis/química , Química Click , Polietilenoglicóis/química , Alcinos/química , Animais , Azidas/química , Plásticos Biodegradáveis/farmacologia , Hidrogel de Polietilenoglicol-Dimetacrilato/administração & dosagem , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Camundongos , Polietilenoglicóis/administração & dosagem
14.
Nanotechnology ; 26(39): 395602, 2015 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-26357961

RESUMO

In this paper, we first synthesized a novel disulfide-coupled bis-(cyclic carbonate) (TDCSS) monomer. After ring-opening co-polymerization (ROP) of TDCSS and trimethylene carbonate (TMC) initiated by mono-methoxyl poly(ethylene glycol), the crosslinked reduction-sensitive copolymer PEG-P(TMC-co-TDCSS) was obtained via a facile one-step procedure for efficient delivery of doxorubicin (DOX) into cancer cells. To serve as controls, PEG-P(TMC-co-TDCCC), which has an analogous structure without disulfide bond, and a linear polymer PEG-PTMC were also prepared. The copolymers could self-assemble to form nano-sized micelles in an aqueous solution. As compared to PEG-PTMC, crosslinked PEG-P(TMC-co-TDCSS) and PEG-P(TMC-co-TDCCC) showed lower CMC values and thus induced a much better micelle-forming ability. In vitro release studies revealed that the drug release behavior of DOX-loaded PEG-P(TMC-co-TDCSS) micelles, which could be accelerated in the presence of 10 mM dithiothreitol (DTT), showed a similar trend in the absence of DTT compared to DOX-loaded PEG-P(TMC-co-TDCCC) micelles. Furthermore, confocal laser scanning microscopy (CLSM) indicated that DOX-loaded PEG-P(TMC-co-TDCSS) micelles were efficiently internalized into HeLa cells, releasing DOX into the cytoplasm after which the drug finally entered the nuclei, while MTT assays also demonstrated potent cytotoxic activity against HeLa cells. DOX was mainly located in the cytoplasm for reduction-insensitive PEG-P(TMC-co-TDCCC) and PEG-PTMC controls.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Doxorrubicina/administração & dosagem , Sistemas de Liberação de Medicamentos , Micelas , Nanopartículas/química , Polietilenoglicóis/química , Tensoativos/síntese química , Antibióticos Antineoplásicos/farmacocinética , Doxorrubicina/farmacocinética , Células HeLa , Humanos , Estrutura Molecular , Nanopartículas/ultraestrutura , Tamanho da Partícula
15.
J Mater Sci Mater Med ; 26(12): 265, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26507198

RESUMO

Ti-10Cu sintered alloy has shown very strong in vitro and in vivo antibacterial property and in vitro cell compatibility. In this paper, Ti-10Cu implant (Ti-Cu group) and commercial pure Ti implant (cp-Ti group) were implanted in rabbit femurs to investigate in vivo bone response to the Ti-10Cu alloy. X-ray photo, fluorescent microscopy, routine pathological examination and immunohistochemistry have been used to analyze bone growth, mineral apposition rate (MAR), bone implant contact (BIC), BMP-2 expression and TGF-ß1 expression. In both Ti-Cu and cp-Ti groups, new bone tissue was found at bone/implant interfaces 4 weeks postimplantation and completely filled the interfaces gap bone 12 weeks postimplantation. A significant MOD value in BMP-2 expression was observed at week 1 and week 4 in the Ti-Cu group with lower values of week 2 and 3 in both groups, which indicated strong positive activity. MOD value in TGF-ß1 expression decreased with the extension of implantation. However, no difference can be found in MAR, BIC and TGF-ß1 expression between the two groups at all intervals. It was deduced that Ti-Cu alloy exhibited as good bone response as cp-Ti. The good bone compatibility suggests that Ti-10Cu alloy might have potential application in orthopedic surgery and dental implant.


Assuntos
Ligas/química , Antibacterianos/farmacologia , Materiais Biocompatíveis , Osso e Ossos/efeitos dos fármacos , Cobre/química , Titânio/química , Animais , Feminino , Microscopia de Fluorescência , Coelhos
16.
Nano Lett ; 13(3): 1271-7, 2013 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-23438038

RESUMO

Flexible and transparent power sources are highly desirable in realizing next-generation all-in-one bendable, implantable, and wearable electronic systems. The developed power sources are either flexible but opaque or semitransparent but lack of flexibility. Therefore, there is increasing recognition of the need for a new concept of electrochemical device structure design that allows both high flexibility and transparency. In this paper, we present a new concept for electrochemical device design--a two-dimensional planar comb-teeth architecture on PET substrate--to achieve both high mechanical flexibility and light transparency. Two types of prototypes--dye-sensitized solar cells and supercapacitors--have been fabricated as planar devices and demonstrated excellent device performance, such as good light transparency, excellent flexibility, outstanding multiple large bending tolerance, light weight, effective prevention of short circuits during bending, and high device integration with up-date microelectronics, compared to conventional sandwich structure devices. Our planar design provides an attractive strategy toward the development of flexible, semitransparent electrochemical devices for fully all-in-one elegant and wearable energy management.

17.
Toxics ; 12(6)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38922093

RESUMO

The bioaccessibility of particle-bound hydrophobic organic contaminants, such as polycyclic aromatic hydrocarbons (PAHs), and the factors influencing their re-release are crucial for assessing potential human health risks via inhalation and hand-mouth exposure. However, the mechanisms by which various factors affect the re-release of PAHs in body fluids, particularly in response to environmental changes like freeze-thaw cycles, remain unclear. To obtain a better understanding, an in vitro method was employed to investigate the re-release processes of PAHs from different soil types (ferrallitic soil and calcareous soil) in simulated body fluids (simulated lung fluid and simulated saliva) under varying freeze-thaw conditions (0, 15, and 30 cycles). The findings indicated that the bioaccessibilities of phenanthrene and pyrene decreased with the frequency of freeze-thaw cycles, which were constrained by soil nature and simulated body fluids compositions as well. Additionally, this study observed that the portion of reversible adsorption of PAHs declined after exposure to freeze-thaw cycles in a nonlinear manner, suggesting that the potential human health risk associated with PAHs could be mitigated due to the "aging effect" which occurred as PAHs became less bioaccessible over time. These results underscore the importance of considering the characteristics of pollutants, body fluids, and environmental media when conducting a precise assessment of the human health risks posed by such contaminants.

18.
Arch Osteoporos ; 19(1): 38, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750277

RESUMO

Data from English randomized controlled trials comparing unilateral versus bilateral PKP for the treatment of OVCFs were retrieved and analyzed, and the results showed that unilateral PKP is a better choice for the treatment of patients with OVCFs, which will provide a reliable clinical rationale for the treatment of OVCFs. PURPOSE: To investigate the advantages of unilateral percutaneous kyphoplasty (PKP) for the treatment of osteoporotic vertebral compression fractures(OVCFs). METHODS: The systematic evaluation program met all program requirements (CRD 42023422383) by successfully passing the PROSPERO International Prospective Systematic Evaluation Registry. Researchers searched the references of English-language randomized controlled trials comparing unilateral and bilateral PKP for the treatment of osteoporotic vertebral compression fractures published between 2010 and 2023 and manually searched for known primary and review articles. The study statistically analyzed data from all the included literature, which primarily included time to surgery, visual pain score(VAS) and Oswestry disability index(ODI) at postoperative follow-up time points, polymethylmethacrylate (PMMA, bone cement) injection dose, cement leakage, radiation dose, and improvement in kyphotic angle. RESULTS: This meta-analysis searched 416 articles published from 2010 to 2023 based on keywords, and 18 articles were finally included in this study. The results of the forest plot showed that unilateral PKP operative time, amount of bone cement used, and radiation dose to the patient were significantly reduced (p < 0.01, p < 0.01, and p < 0.01, respectively), and unilateral and bilateral PKP had comparable cement leakage (p = 0.49, 95% CI = 0.58-1.30), and there was no significant difference in the kyphotic angle between unilateral and bilateral PKP (p = 0.42, 95% CI = - 2.29-0.96). During follow-up, there was no significant difference in pain relief between unilateral and bilateral PKP (p = 0.70, 95% CI = - 0.09-0.06), nor was there a significant difference in ODI (p = 0.27, 95% CI = - 0.35-1.24). CONCLUSIONS: There is no difference in clinical efficacy between unilateral PKP and bilateral PKP, but unilateral PKP has a shorter operative time, a lower incidence of cement leakage, a lower amount of cement, and a lower radiation dose to the patient and operator. Unilateral PKP is a better option for patients with OVCFs.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Humanos , Cifoplastia/métodos , Fraturas por Compressão/cirurgia , Fraturas por Osteoporose/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Cimentos Ósseos/uso terapêutico , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
19.
Adv Healthc Mater ; 13(7): e2302901, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38102773

RESUMO

Bone metastases severely threaten the lives of patients. Although surgical treatment combined with adjuvant chemotherapy significantly improves the survival rate of patients, tumor recurrence, or metastasis after surgical resection and bone defects caused by surgical treatment remain major challenges for clinicians. Given the abovementioned clinical requirements, barium titanate-containing iron-coated porous titanium alloy scaffolds have been proposed to promote bone defect repair and inhibit tumor recurrence. Fortunately, in vitro and in vivo experimental research confirms that barium titanate containing iron-coated porous titanium alloy scaffolds promote osteogenesis and bone reconstruction in defect repair via mechanoelectric conversion and inhibit tumor recurrence via photothermal effects. Furthermore, the underlying and intricate mechanisms of bone defect repair and tumor recurrence prevention of barium titanate-containing iron-coated porous titanium alloy scaffolds are explored. A win-win strategy for mechanoelectrical conversion and photothermal functionalization provides promising insights into bone reconstruction of tumor-resected defects.


Assuntos
Alicerces Teciduais , Titânio , Humanos , Titânio/farmacologia , Porosidade , Bário , Recidiva Local de Neoplasia , Osteogênese , Ligas , Ferro
20.
J Periodontal Implant Sci ; 54(1): 53-62, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37336523

RESUMO

PURPOSE: This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. METHODS: This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006-2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan-Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. RESULTS: Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between external- and internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. CONCLUSIONS: Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA