Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Endovasc Ther ; 23(3): 424-32, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27044270

RESUMO

PURPOSE: To identify intravascular ultrasound (IVUS) measurements that can predict angiographic in-stent restenosis (ISR) following nitinol stent implantation in superficial femoral artery (SFA) lesions. METHODS: A retrospective review was conducted of 97 patients (mean age 72.9±8.9 years; 63 men) who underwent IVUS examination during endovascular treatment of 112 de novo SFA lesions between July 2012 and December 2014. Self-expanding bare stents were implanted in 46 lesions and paclitaxel-eluting stents in 39 lesions. Six months after stenting, follow-up angiography was conducted to assess stent patency. The primary endpoint was angiographic ISR determined by quantitative vascular angiography analysis at the 6-month follow-up. Variables associated with restenosis were sought in multivariate analysis; the results are presented as the odds ratio (OR) and 95% confidence interval (CI). RESULTS: At follow-up, 27 (31.8%) angiographic ISR lesions were recorded. The lesions treated with uncoated stents were more prevalent in the ISR group compared with the no restenosis group (74.1% vs 44.8%, p=0.02). Lesion length was longer (154.4±79.5 vs 109.0±89.3 mm, p=0.03) and postprocedure minimum stent area (MSA) measured by IVUS was smaller (13.9±2.8 vs 16.3±1.6 mm(2), p<0.001) in the ISR group. Multivariate analysis revealed that bare stent use (OR 7.11, 95% CI 1.70 to 29.80, p<0.01) and longer lesion length (OR 1.08, 95% CI 1.01 to 1.16, p=0.04) were predictors of ISR, while increasing postprocedure MSA (OR 0.58, 95% CI 0.41 to 0.82, p<0.01) was associated with lower risk of ISR. Receiver operating characteristic analysis identified a MSA of 15.5 mm(2) as the optimal cutpoint below which the incidence of restenosis increased (area under the curve 0.769). CONCLUSION: Postprocedure MSA can predict ISR in SFA lesions, which suggests that adequate stent enlargement during angioplasty might be required for superior patency.


Assuntos
Ligas , Angiografia , Angioplastia com Balão/instrumentação , Constrição Patológica , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/terapia , Stents , Ultrassonografia de Intervenção , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Área Sob a Curva , Fármacos Cardiovasculares/administração & dosagem , Distribuição de Qui-Quadrado , Stents Farmacológicos , Feminino , Artéria Femoral/fisiopatologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Paclitaxel/administração & dosagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Valor Preditivo dos Testes , Desenho de Prótese , Curva ROC , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Catheter Cardiovasc Interv ; 83(1): 19-24, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23413202

RESUMO

OBJECTIVES: The aim of this study was to evaluate the Sparrow sirolimus-eluting stent (Sparrow-SES) against the Sparrow bare-metal stent (Sparrow-BMS) and conventional balloon-expandable bare-metal stent (BMS: Driver/Micro-Driver stent, Medtronic Vascular, Santa Rosa, CA). BACKGROUND: The Sparrow stent (Biosensors International, Singapore) consists of a guide wire-based, self-expandable, ultra-thin nitinol stent. The performance of this device with sirolimus in a fully biodegradable polymer has not been determined. METHODS: A total of 74 patients were included in this intravascular ultrasound (IVUS) sub-study of the CARE II trial, which was a prospective, randomized, multicenter trial in the treatment of single de novo native coronary artery lesions in vessels ranging from 2.0 mm to 2.75 mm in diameter (Sparrow-SES: n = 31, Sparrow-BMS: n = 22, BMS: n = 21). RESULTS: Stent volume index (VI) was significantly increased 8-month later in Sparrow-SES and Sparrow-BMS, but not in BMS (4.0 ± 1.0 to 4.6 ± 1.0 mm(3) /mm, p<0.0001, 4.0 ± 0.6 to 4.4 ± 0.8 mm(3) /mm, p<0.05, and 5.2 ± 1.0 to 5.1 ± 0.9 mm(3) /mm, p=0.421, respectively). % neointimal obstruction in Sparrow-SES was significantly smaller than those in Sparrow-BMS and BMS at follow-up (17.6 ± 9.4 vs. 36.2 ± 13.8 and 39.9 ± 11.1%, p<0.001). Sparrow-SES showed a mean 15% stent expansion and good suppression of neointimal proliferation, resulting in a significantly lower percentage of change in lumen VI during follow-up period (Sparrow-SES: -6.2 ± 16.2%, Sparrow-BMS: -30.4 ± 11.6%, BMS: -40.4 ± 10.0%, p<0.001). CONCLUSIONS: The self-expanding Sparrow-SES demonstrated chronic stent expansion, good suppression of neointimal proliferation and resulted in a more preserved lumen in stented small vessels compared with the Sparrow-BMS and conventional balloon expandable BMS.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Sirolimo/administração & dosagem , Stents , Ultrassonografia de Intervenção , Idoso , Ligas , Angioplastia Coronária com Balão/efeitos adversos , Proliferação de Células , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 81(4): E199-205, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22639187

RESUMO

OBJECTIVES: To elucidate the optimal cutoff and accuracy of duplex ultrasonography (DUS) parameters for in-stent restenosis (ISR) after nitinol stenting in the superficial femoral artery (SFA). BACKGROUND: Few data are available regarding the performance of DUS for binary ISR based on quantitative vessel analysis (QVA) in the era of SFA nitinol stenting. METHODS: This retrospective study included 74 in-stent stenoses of SFA who underwent DUS before follow-up angiography. DUS parameters, such as peak systolic velocity (PSV) and the peak systolic velocity ratio (PSVR), were compared with percent diameter stenosis (%DS) from a QVA basis. RESULTS: There was a statistically significant correlation (P < 0.001) between "%DS and PSV" and "%DS and PSVR," and the correlation with %DS proved to be stronger in PSVR (R = 0.720) than in PSV (R = 0.672). The best performing parameter for ISR (50% or greater stenosis) was revealed PSVR, as the areas under the receiver operator characteristics curves using PSVR and PSV were 0.908 and 0.832, respectively. A PSVR cut off value of 2.85 yielded the best predictive value with sensitivity of 88%, specificity of 84%, and accuracy of 86%. The positive predictive value was 85% and the negative predictive value was 88%. CONCLUSIONS: A PSVR of 2.85 is the optimal threshold for ISR after nitinol stenting in the SFA. Further large prospective studies are required for the validation and establishment of uniform criteria for DUS parameters.


Assuntos
Angioplastia com Balão/instrumentação , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Stents , Ultrassonografia Doppler Dupla , Idoso , Idoso de 80 Anos ou mais , Ligas , Angioplastia com Balão/efeitos adversos , Área Sob a Curva , Velocidade do Fluxo Sanguíneo , Constrição Patológica , Feminino , Artéria Femoral/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/fisiopatologia , Valor Preditivo dos Testes , Desenho de Prótese , Curva ROC , Radiografia , Recidiva , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
4.
Cardiovasc Interv Ther ; 38(2): 210-222, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36255689

RESUMO

BACKGROUND: Mechanism of femoropopliteal in-stent restenosis has been underappreciated. AIM: The aim of this animal study was to elucidate vascular response after femoropopliteal bare nitinol self-expanding stents (SESs) implantation. METHODS: Misago, Smart Flex, or Innova stent was randomly implanted in 36 swine femoropopliteal arteries. At week 4, quantitative vessel analysis (QVA) was performed on 36 legs, of which 18 underwent histological evaluation after angiography. The remaining 18 legs underwent QVA and histological evaluation at week 13. RESULTS: Fibrin deposition was excessive at week 4. Internal elastic lamina (IEL) progressively enlarged over time, and vessel injury developed from mild level at week 4 to moderate level at week 13. Vessel inflammatory reaction was mild to moderate at week 4, and was moderate to severe at week 13. Increased fibrin deposition was an early-acting, IEL enlargement and increased vessel inflammation were long-acting, and increased vessel injury and giant cells infiltration were late-acting contributors to neointimal hyperplasia (NIH). Stent type altered time-dependent process of vessel injury, vessel inflammation, eosinophils and giant cells infiltration. Misago had less fibrin deposition and vessel enlargement, and less progressive vessel injury, vessel inflammation, and eosinophils and giant cells infiltration. Net lumen as assessed by percent diameter stenosis or minimum lumen diameter was preserved with Misago, but was not preserved with the other stents. CONCLUSIONS: In the context of bare nitinol SES platform with less progressive mechanical stress and inflammatory reaction, the advantage of less NIH outweighed the disadvantage of less vessel enlargement, leading to net lumen preservation.


Assuntos
Artéria Femoral , Stents , Animais , Ligas , Artéria Femoral/cirurgia , Artéria Femoral/patologia , Fibrina , Desenho de Prótese , Stents/efeitos adversos , Suínos , Resultado do Tratamento
5.
Circ J ; 74(10): 2097-102, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20689221

RESUMO

BACKGROUND: The Resolute stent is a newly developed system with a bio-histocompatible polymer that allows programmed drug delivery up to 180 days. The aim of this intravascular ultrasound (IVUS) analysis was to evaluate the short- (4 months) and mid-term (9 months) efficacy using the Resolute stent. METHODS AND RESULTS: Data were derived from the RESOLUTE trial, a prospective, multicenter, non-randomized, single-arm study to treat de novo native coronary artery lesions. This trial included 2 cohorts with different follow-up periods, and all enrollment patients in this trial received IVUS study. Follow-up IVUS was available in 24 patients (4-month group) and 88 patients (9-month group). Neointimal obstruction (%) was defined as neointimal volume divided by stent volume. Cross-sectional narrowing (CSN, %) was defined as neointimal area divided by stent area. No significant differences in vessel, lumen and stent volume at post-procedure were observed within stented segments between the 4- and 9-month follow-up groups. Although neointimal volume and % neointimal obstruction showed no significant difference between the 2 groups (% neointimal obstruction: 2.2 ± 2.5 vs 3.7 ± 4.0%, P=0.09), maximum CSN was significantly larger in the 9-month group. There were 7 cases of late incomplete stent apposition. CONCLUSIONS: These IVUS results showed minimum growth of neointimal proliferation by the Resolute stent throughout the stented segment up to 9 months follow up.


Assuntos
Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos/normas , Polímeros/uso terapêutico , Sirolimo/análogos & derivados , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/patologia , Sirolimo/administração & dosagem , Fatores de Tempo , Ultrassonografia de Intervenção
6.
JACC Cardiovasc Interv ; 13(1): 116-127, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31918929

RESUMO

OBJECTIVES: The aim of this study was to investigate the vascular responses and fates of the scaffold after bioresorbable vascular scaffold (BVS) implantation using multimodality imaging. BACKGROUND: Serial comprehensive image assessments after BVS implantation in the context of a randomized trial have not yet been reported. METHODS: In the ABSORB Japan trial, 400 patients were randomized to a BVS (n = 266) or a cobalt-chromium everolimus-eluting stent (n = 134). Through 3 years, patients underwent serial angiography and intravascular ultrasound or optical coherence tomography (OCT). RESULTS: Luminal dimension at 3 years was consistently smaller with the BVS than with the cobalt-chromium everolimus-eluting stent (mean angiographic minimal luminal diameter 2.04 ± 0.63 mm vs. 2.40 ± 0.56 mm, mean difference -0.37 mm [95% confidence interval: -0.50 to -0.24 mm]; p < 0.001), mainly because of smaller device area (6.13 ± 2.03 mm2 vs. 7.15 ± 2.16 mm2, mean difference -1.04 mm2 [95% confidence interval: -1.66 to -0.42 mm2]; p < 0.001), and larger neointimal area (2.10 ± 0.61 mm2 vs. 1.86 ± 0.64 mm2, mean difference 0.24 mm2 [95% confidence interval: 0.06 to 0.43 mm2]; p = 0.01) by OCT. BVS-treated vessels did not show previously reported favorable vessel responses, such as positive vessel remodeling, late luminal enlargement, and restoration of vasomotion, although the OCT-based healing score was on average zero (interquartile range: 0.00 to 0.00). At 3 years, intraluminal scaffold dismantling (ISD) was observed in 14% of BVS. On serial OCT, ISD was observed in 6 lesions at 2 years, where the struts had been fully apposed at post-procedure, while ISD was observed in 12 lesions at 3 years, where 8 lesions were free from ISD on 2-year OCT. In 5 cases of very late scaffold thrombosis, strut discontinuities were detected in all 4 cases with available OCT immediately before reintervention. CONCLUSIONS: In this multimodality serial imaging study, luminal dimension at 3 years was smaller with the BVS than with the cobalt-chromium everolimus-eluting stent. ISD, suspected to be one of the mechanisms of very late BVS thrombosis, was observed in a substantial proportion of cases at 3 years, which developed between post-procedure and 2 years and even beyond 2 years. (AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 [Absorb™ BVS] in Japanese Population [ABSORB JAPAN]; NCT01844284).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/administração & dosagem , Imagem Multimodal , Intervenção Coronária Percutânea/instrumentação , Stents , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Everolimo/efeitos adversos , Humanos , Japão , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
7.
Catheter Cardiovasc Interv ; 73(1): 34-41, 2009 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-19089934

RESUMO

OBJECTIVE: To assess the efficacy of the AXXESS stent on the treatment of left main coronary artery (LMCA) bifurcation lesions using IVUS. BACKGROUND: The treatment of LMCA bifurcation lesions remains challenging even with the use of drug-eluting stents. The AXXESS system is a biolimus A9-eluting self-expanding stent, dedicated to the treatment of bifurcation lesions. METHODS: Data were obtained from the AXXENT trial, a prospective, single-arm, multicenter study designed to evaluate the efficacy of the AXXESS stent on the treatment of LMCA bifurcation lesions. IVUS was available in 26 cases at 6-months follow-up. Volumetric and cross-sectional analyses within the AXXESS stent, and cross-sectional analyses at the ostia of left anterior descending (LAD) and left circumflex coronary arteries (LCX) were performed. RESULTS: Within the AXXESS stent, percent neointimal volume obstruction was (3.0 +/- 4.1)% with a minimal lumen area of 10.3 +/- 2.6 mm(2). AXXESS stent volume showed an 12.4% increase at follow-up compared with postprocedure (P = 0.04). Lumen area was significantly smaller in the LCX ostium compared with the LAD ostium at follow-up (3.6 +/- 1.3 mm(2) vs. 5.5 +/- 2.0 mm(2), P = 0.0112). There was greater neointimal formation in the LCX ostium compared with the LAD ostium (1.37 +/- 1.20 mm(2) vs. 0.30 +/- 0.36 mm(2), P = 0.0003). CONCLUSIONS: The AXXESS stent in the LMCA showed enlargement through 6-months follow-up and significant neointimal suppression. Greater neointimal formation and relatively inadequate stent expansion may contribute to luminal narrowing in the LCX ostium.


Assuntos
Ligas , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Stents , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Proliferação de Células , Angiografia Coronária , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/patologia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Túnica Íntima/patologia , Estados Unidos
8.
Am J Cardiol ; 100(5): 818-23, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17719326

RESUMO

Zotarolimus-eluting phosphorylcholine-coated cobalt-chromium alloy Driver stents (ZES) demonstrated significant reductions in target lesion revascularization rate with few apparent adverse events compared with bare metal stents (BMS; uncoated Driver stents) in a prospective, multicenter, double-blind, randomized controlled trial in de novo coronary lesions. The aim of this study was to examine detailed vascular responses to ZES compared with BMS using serial intravascular ultrasound analysis. A total of 343 patients (ZES n = 178, BMS n = 165) were enrolled in this formal, prespecified intravascular ultrasound substudy of the Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE Zotarolimus-Eluting Driver Coronary Stent in de Novo Native Coronary Artery Lesions (ENDEAVOR II), a prospective, multicenter, double-blind, randomized controlled trial to compare ZES and BMS in de novo native coronary artery lesions. Quantitative and qualitative intravascular ultrasound analyses were performed postprocedurally and at 8-month follow-up in stented and reference segments. ZES showed significantly less neointima, with a larger lumen than BMS at 8 months (percentage neointimal volume 17.6 +/- 10.1% vs 29.4 +/- 17.2%, p <0.0001; maximum percentage neointimal area 32.9 +/- 13.0% vs 47.6 +/- 18.6%, p <0.0001; minimum luminal area 4.9 +/- 1.6 vs 4.0 +/- 1.7 mm(2), p <0.0001) and no unfavorable edge effect. In the 18-mm single stents, ZES showed evenly inhibited neointima compared with BMS. Neither persistent stent-edge dissection nor late-acquired incomplete stent apposition was observed in either group. In conclusion, ZES showed evenly inhibited neointima with no apparent adverse vascular response in stented and reference segments at 8 months compared with BMS.


Assuntos
Ligas de Cromo/química , Materiais Revestidos Biocompatíveis/química , Doença da Artéria Coronariana/cirurgia , Endossonografia , Imunossupressores/uso terapêutico , Fosforilcolina/química , Sirolimo/análogos & derivados , Stents , Estudos de Coortes , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sirolimo/administração & dosagem , Sirolimo/uso terapêutico , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/efeitos dos fármacos
9.
Am J Cardiol ; 98(4): 464-9, 2006 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16893698

RESUMO

The everolimus-eluting stent (EES) has been shown to significantly decrease neointimal proliferation at 6 months compared with the bare metal stent (BMS) in patients with de novo coronary lesions. We report mid-term outcomes based on different vessel sizes in the combined FUTURE I and II trials. In the prospective, randomized, FUTURE I trial (single center) and expanded FUTURE II trial (multicenter), 106 patients (107 lesions) were randomized to EESs (n = 49 lesions) or BMSs (n = 58 lesions). Patients were categorized into 3 groups based on preprocedure reference diameter as assessed by quantitative coronary angiography (small vessel < 2.75 mm, medium vessel 2.75 to 3.25 mm, and large vessel > 3.25 mm). At 6-month follow-up, EESs decreased in-stent late lumen loss (decreased rate range of 78% to 94%), resulting in significantly larger minimum lumen area as assessed by intravascular ultrasound (increased range of 34% to 42%) compared with the BMS across all vessel sizes. There were no cases of in-stent restenosis with EESs at any vessel size but 8 cases with BMSs (5 in small vessels). No stent thrombosis, aneurysm formation, or late stent incomplete apposition was observed in any group. The EES appears to be effective for treatment of de novo coronary lesions in decreasing neointimal proliferation at 6-month follow-up compared with BMSs, regardless of vessel size.


Assuntos
Implante de Prótese Vascular/instrumentação , Materiais Revestidos Biocompatíveis , Reestenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Imunossupressores/uso terapêutico , Sirolimo/análogos & derivados , Stents , Idoso , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Everolimo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sirolimo/uso terapêutico , Resultado do Tratamento , Ultrassonografia de Intervenção
10.
EuroIntervention ; 12(12): 1551-1558, 2016 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-27998849

RESUMO

AIMS: This study sought to investigate differences in vascular response between self-expanding bare metal nitinol stents (BMS) and paclitaxel-eluting nitinol stents (PES), in superficial femoral artery (SFA) disease, using optical frequency domain imaging (OFDI). METHODS AND RESULTS: Six months after stent implantation, follow-up quantitative vascular angiography (QVA) and OFDI assessment were scheduled to evaluate vascular response. Volume index (VI) was defined as volume divided by stent length. The primary endpoint was OFDI-derived late lumen area loss, defined as lumen VI post stent implantation minus lumen VI at follow-up. A total of 28 SFA lesions were analysed, with cases randomised to receive either BMS or PES implantation. QVA-derived diameter stenosis at six-month follow-up was lower in the PES group than in the BMS group (28.5% vs. 39.7%, p=0.04). After six months, BMS VI increased by 33.8% (20.7±3.7 to 27.7±3.5 mm3/mm), whilst PES exhibited an increase of 32.1% (19.0±2.3 to 25.1±4.7 mm3/mm). Neointimal VI was smaller (7.4±2.6 mm3/mm vs. 10.5±3.2 mm3/mm, p<0.01) and late lumen area loss was lower (2.9±1.3 mm3/mm vs. 5.6±2.8 mm3/mm, p<0.01) in the PES group. CONCLUSIONS: Serial volumetric OFDI analyses confirmed significantly smaller amounts of neointimal tissue and lower late lumen area loss following PES implantation for SFA lesions at short-term follow-up.


Assuntos
Ligas/uso terapêutico , Stents Farmacológicos , Artéria Femoral/cirurgia , Neointima/cirurgia , Imagem Óptica , Paclitaxel/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/diagnóstico , Imagem Óptica/métodos , Ultrassonografia de Intervenção/métodos
11.
EuroIntervention ; 12(12): 1498-1509, 2016 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-26448577

RESUMO

AIMS: Fully bioresorbable Absorb poly-L-lactic-acid (PLLA) scaffolds (Abbott Vascular, Santa Clara, CA, USA) are a novel approach for the treatment of coronary narrowing. Due to the translucency of the material (PLLA), the optical coherence tomography (OCT) measurement methods used in the ABSORB trials were unique but not applicable for permanent metallic stents. When the Absorb scaffold and metallic stents are compared in the context of randomised trials, it is challenging to compare the two devices using the conventional methods. The primary purpose of this report is to explain the biases in conventional methodologies applied for metallic stents and for PLLA scaffolds at baseline and follow-up, and to propose a new standard methodology that enables us to compare two different devices using an almost identical and methodological language. METHODS AND RESULTS: A consensus amongst multiple core labs and expert researchers of OCT was reached on a new standard OCT measurement methodology that enables us to compare these two different devices. In brief, the proposed OCT methods are summarised as follows. 1) Both endoluminal and abluminal scaffold/stent contours should be traced. 2) Consistently, endoluminal and abluminal incomplete stent apposition areas should be measured. 3) The area occupied by scaffold/stent struts should be quantified directly or virtually. 4) The strut area should be systematically excluded from the flow area as well as the neointimal area. 5) Additional information on the degree of embedment could be reported using the interpolated lumen contour. Interobserver variability of the proposed method was excellent (intraclass correlation 0.89-100). CONCLUSIONS: A standardised OCT measurement methodology is proposed. This should be implemented in ongoing and future trials comparing the Absorb scaffolds and metallic stents.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Tomografia de Coerência Óptica , Angiografia Coronária/métodos , Stents Farmacológicos/efeitos adversos , Everolimo/uso terapêutico , Seguimentos , Humanos , Intervenção Coronária Percutânea/métodos , Poliésteres , Desenho de Prótese , Tomografia de Coerência Óptica/métodos
12.
Circulation ; 109(18): 2168-71, 2004 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-15123533

RESUMO

BACKGROUND: Everolimus, an active immunosuppressive and antiproliferative agent of the same family as sirolimus (rapamycin), has demonstrated significant reduction of neointimal proliferation in animal studies. The First Use To Underscore restenosis Reduction with Everolimus (FUTURE) I trial was the first in-human experience to evaluate the safety and efficacy of everolimus-eluting stents (EES), coated with a bioabsorbable polymer, compared with bare metal stents (BMS). METHODS AND RESULTS: FUTURE I was a prospective, single-blind, randomized trial that enrolled 42 patients with de novo coronary lesions (EES 27, BMS 15). Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low at 30 days and 6 months, without any early or late stent thrombosis for either group (P=NS). Between 6 and 12 months, there were no additional reports of major adverse cardiac events. The 6-month angiographic in-stent restenosis rate was 0% versus 9.1% (1 patient) (P=NS), with an associated late loss of 0.11 mm versus 0.85 mm (P<0.001), and the in-segment restenosis rate was 4% (1 patient) and 9.1% (1 patient) (P=NS) for EES and BMS, respectively. Intravascular ultrasound analysis revealed a significant reduction of percent neointimal volume in EES compared with BMS (2.9+/-1.9 mm3/mm versus 22.4+/-9.4 mm3/mm, P<0.001). There was no late stent malapposition in either group. The safety and efficacy of the EES appeared to be sustained at 12 months. CONCLUSIONS: In this initial clinical experience, EES with bioabsorbable polymer demonstrated a safe and efficacious method to reduce in-stent neointimal hyperplasia and restenosis.


Assuntos
Reestenose Coronária/prevenção & controle , Estenose Coronária/terapia , Inibidores do Crescimento/uso terapêutico , Imunossupressores/uso terapêutico , Sirolimo/uso terapêutico , Stents , Idoso , Anticoagulantes/uso terapêutico , Cateterismo , Cineangiografia , Materiais Revestidos Biocompatíveis , Comorbidade , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Estenose Coronária/tratamento farmacológico , Implantes de Medicamento , Everolimo , Feminino , Seguimentos , Inibidores do Crescimento/administração & dosagem , Humanos , Hiperplasia , Imunossupressores/administração & dosagem , Ácido Láctico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/prevenção & controle , Poliésteres , Polímeros , Estudos Prospectivos , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Aço Inoxidável , Resultado do Tratamento , Túnica Íntima/patologia , Ultrassonografia de Intervenção
13.
Am J Cardiol ; 96(10): 1404-7, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16275187

RESUMO

To assess whether asymmetric stent expansion affects suppression of neointimal hyperplasia after sirolimus-eluting stent implantation, 64 patients in the SIRolImUS-coated Bx Velocity stent trial who underwent single 18-mm stent implantation and 3-dimensional intravascular ultrasonography at 8-month follow-up were enrolled. To assess the longitudinal stent asymmetric expansion, 2 cross sections with a maximal/minimal stent area were chosen in each patient. To assess for tomographic stent asymmetric expansion, stent eccentricity was determined by dividing the minimum stent diameter by the maximum stent diameter. At the 2 cross sections with a maximal/minimal stent area, a sirolimus-eluting stent reduced neointimal hyperplasia significantly with no interaction between the treatment and stent areas. A sirolimus-eluting stent also significantly reduced neointimal hyperplasia in the concentric and eccentric stent groups.


Assuntos
Materiais Revestidos Biocompatíveis/uso terapêutico , Imunossupressores/uso terapêutico , Sirolimo/uso terapêutico , Stents , Túnica Íntima/patologia , Angioplastia Coronária com Balão , Implante de Prótese Vascular , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Método Duplo-Cego , Seguimentos , Humanos , Hiperplasia/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Resultado do Tratamento , Túnica Íntima/efeitos dos fármacos , Túnica Íntima/cirurgia , Ultrassonografia de Intervenção
14.
Am J Cardiol ; 96(9): 1237-41, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16253589

RESUMO

The effect of lesion characteristics on neointimal hyperplasia after sirolimus-eluting stent implantation was examined in 45 patients who underwent successful preinterventional intravascular ultrasound. There were no differences in neointimal hyperplasia between the moderate/severe calcified lesion group (calcium arc >120 degrees ) and the non/mild calcified lesion group or between the positive vessel remodeling group (external elastic membrane area at the minimal lumen area site larger than that at the proximal reference site) and negative vessel remodeling group. No correlation between preinterventional plaque burden and neointimal hyperplasia was found. In patients who have coronary artery disease, sirolimus-eluting stents continue to demonstrate striking suppression of neointimal proliferation, irrespective of lesion characteristics previously associated with greater restenotic risk.


Assuntos
Implante de Prótese Vascular/instrumentação , Materiais Revestidos Biocompatíveis/efeitos adversos , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Sirolimo/farmacologia , Stents/efeitos adversos , Ultrassonografia de Intervenção , Implante de Prótese Vascular/efeitos adversos , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Progressão da Doença , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Hiperplasia/diagnóstico por imagem , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Falha de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/patologia
15.
Am J Cardiol ; 96(9): 1251-3, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16253592

RESUMO

To study the interaction of the sirolimus-eluting stent and vessel margins, we analyzed the intravascular ultrasound parameters in 317 edges of 167 stents having 18 edge stenoses at 8 months of follow-up from the SIRIUS trial. Of the baseline parameters, a larger reference percentage of plaque area and a larger edge stent area/reference minimum lumen area were associated with edge stenosis in the sirolimus-eluting stent cohort compared with the incidence of edge stenosis in the bare metal stent cohort. Thus, full lesion coverage and matching the stented segment properly to the adjacent segment using intravascular ultrasound guidance may improve sirolimus-eluting stent implantation efficacy further.


Assuntos
Implante de Prótese Vascular/instrumentação , Materiais Revestidos Biocompatíveis , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Sirolimo/farmacologia , Stents , Ultrassonografia de Intervenção , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Seguimentos , Humanos , Imunossupressores/farmacologia , Metais , Estudos Multicêntricos como Assunto , Razão de Chances , Valor Preditivo dos Testes , Prognóstico , Falha de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco
16.
J Invasive Cardiol ; 15(3): 109-14, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12612382

RESUMO

Treatment with antiproliferative drugs via coated stents appears to be a promising approach to both mechanically remodel target lesions and biologically reduce neointimal hyperplasia. Drug-eluting stents can maximize local drug effects and minimize the potential for systemic toxic effects. The purpose of this review is to describe the effects of a lipophilic microtubular inhibitor, paclitaxel, a strong antiproliferative agent under clinical investigation, and to define the vascular response to taxol-based eluting stents by intravascular ultrasound.


Assuntos
Inibidores da Angiogênese/farmacologia , Inibidores da Angiogênese/uso terapêutico , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/uso terapêutico , Paclitaxel/farmacologia , Paclitaxel/uso terapêutico , Stents , Implante de Prótese Vascular , Procedimentos Cirúrgicos Cardíacos , Ensaios Clínicos como Assunto , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Humanos , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção
17.
Cardiovasc Revasc Med ; 15(1): 18-22, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24315045

RESUMO

BACKGROUND: The Cobra-P drug-eluting stent (DES) system consists of cobalt chromium alloy with bio-absorbable siloxane sol-gel matrix coating that elutes low dose paclitaxel within 6 months. The aim of this first-in-man trial was to evaluate the safety and performance of 2 doses of the Cobra-P DES. METHODS: A total of 60 lesions (54 patients) were sequentially assigned to 2 different paclitaxel doses: group A (3.7 µg/18mm, n=30) or group B (8 µg/18mm, n=30). The primary endpoint was MACE at 4 months defined as cardiac death, myocardial infarction, and target lesion revascularization. RESULTS: Patient and lesion characteristics were matched between the 2 groups except for male sex. MACE at 4 months was 3.3% and 0% respectively (P=1.000) and at 1-year follow-up remained unchanged. In-stent late loss at 4 months was similar in both groups (0.36 ± 0.30mm and 0.34 ± 0.20mm P=.773). CONCLUSIONS: In this FIM study, implantation of the Cobra-P low dose paclitaxel-eluting stent with a bioabsorbable sol-gel coating was proven to be feasible and safe. Moderate neointimal proliferation was observed as well as an acceptable MACE rate up to 1 year.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Idoso , Proliferação de Células , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Reestenose Coronária/etiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 6(10): 1026-34, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24055443

RESUMO

OBJECTIVES: This first-in-human multicenter study sought to examine prospectively the safety and efficacy of a new, cobalt chromium thin-strut, coronary absorbable polymer-coated, sirolimus-eluting stent. BACKGROUND: Bioabsorbable polymers on drug-eluting stents may lower the long-term risks of inflammation, delayed healing, and adverse events. METHODS: We enrolled patients with symptomatic coronary artery disease with stable or unstable angina pectoris and >50% diameter stenosis, amenable to coverage with a ≤23-mm long stent in a vessel 2.5 to 3.5 mm in diameter. All patients received dual antiplatelet therapy after implantation. Patients, in groups of 10, underwent repeat angiography, intravascular ultrasound, and optical coherence tomography at 4, 6, or 8 months, and all patients were seen or contacted at 18 months of follow-up. RESULTS: The median (range) in-stent late lumen loss (LLL) was 0.03 mm (-0.22 to 0.21 mm), 0.10 mm (-0.03 to 1.2 mm), and 0.08 mm (-0.01 to 0.28 mm), at 4, 6, and 8 months, respectively. At 18 months, the median in-stent LLL was 0.08 mm (-0.30 to 0.46 mm). On optical coherence tomography, the proportion of uncovered stent struts decreased from a median of 7.3% (range 0.4% to 46.3%) at 4 months to 0% (range: 0% to 3.4%) at 18 months. The percentage of neointimal volume obstruction by intravascular ultrasound increased from a median of 5.3% to 9.1% between 4 and 6 months and remained nearly unchanged thereafter through 18 months of follow-up. The only recorded major adverse cardiac event was a myocardial infarction. CONCLUSIONS: At 18 months of follow-up, this absorbable polymer-coated, cobalt chromium sirolimus-eluting stent was associated with a low and stable in-stent LLL, complete strut coverage, and no stent thrombosis. (First-In-Human Trial of the MiStent Drug-Eluting Stent [DES] in Coronary Artery Disease [DESSOLVE-I]; NCT01247428).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Estável/diagnóstico , Angina Estável/terapia , Angina Instável/diagnóstico , Angina Instável/terapia , Austrália , Bélgica , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/patologia , Quimioterapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Neointima , Nova Zelândia , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
19.
Cardiovasc Revasc Med ; 13(2): 111-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22406056

RESUMO

BACKGROUND: Dedicated IVUS analyses of the second CObalt chromium STent with Antiproliferative for Restenosis (COSTAR II) trial have not been documented. We aim to compare IVUS findings between CoStar paclitaxel-eluting stent (PES) and Taxus PES in patients enrolled in the COSTAR II trial. We also attempted to examine the possible regional impact of multiple stenting. METHODS AND MATERIALS: Among the 1700 patients enrolled, 238 were assigned to an IVUS cohort including 168 patients treated by provisional multiple stenting. At 9 months, qualitative and quantitative IVUS observations including incomplete stent apposition (ISA) and neointimal proliferation (neointimal obstruction: neointimal volume/stent volume ×100) were compared between CoStar and Taxus PESs. RESULTS: In qualitative analysis, late-acquired ISA was observed in 1 patient treated by Taxus PES. Impaired strut continuity suggestive of stent fracture was observed in 2 out of 33 patients treated by multiple CoStar, and 4 out of 21 patients treated by multiple Taxus (P=.14). No such findings were found in single-stented patients in either stent subset. Quantitative analysis showed greater neointimal obstruction in CoStar (19.7%±13.4%, n=52) than in Taxus (10.7%±9.9%, n=38), whereas no significant difference in neointimal obstruction was found between single and multiple stenting in either CoStar or Taxus PES. CONCLUSIONS: The CoStar PES exhibits greater neointimal proliferation compared with Taxus PES at 9 months but with similar qualitative outcomes including late-acquired ISA. IVUS findings suggestive of stent fracture were found only in multiple-stenting cases irrespective of the stent used.


Assuntos
Ligas de Cromo , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Neointima/prevenção & controle , Paclitaxel/farmacologia , Ultrassonografia de Intervenção/métodos , Antineoplásicos Fitogênicos/farmacologia , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/diagnóstico por imagem , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
20.
Circ Cardiovasc Interv ; 4(3): 248-55, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21586691

RESUMO

BACKGROUND: Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS: Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; P<0.001). Greater maximum cross-sectional narrowing and higher neointima-free frame ratio, suggesting less neointimal coverage, were observed in Resolute compared with other stent groups. Multiple regression analysis confirmed that the biodurable polymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. CONCLUSIONS: The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.


Assuntos
Angioplastia Coronária com Balão , Stents Farmacológicos , Neointima/patologia , Polímeros/química , Sirolimo/análogos & derivados , Idoso , Proliferação de Células , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Sirolimo/administração & dosagem , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA