Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Revista
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Hernia ; 15(6): 677-84, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21607571

RESUMO

PURPOSE: The purpose of this study is to evaluate the histologic response to fibrin sealant (FS) as an alternative fixation method for laparoscopic ventral hernia repair. METHODS: One non-absorbable barrier mesh (Composix™) and three absorbable barrier meshes (Sepramesh™, Proceed™, and Parietex™ Composite) were used for the study, with uncoated macroporous polypropylene mesh (ProLite Ultra™) as the control. Three methods of fixation were used: #0-polypropylene suture + FS (ARTISS™, Baxter Healthcare Corp.), FS alone (ARTISS™), or tacks alone (n = 10 for each group). Two pieces of mesh (of dimensions 4 × 4-cm) were secured intraperitoneally in 75 New Zealand white rabbits. After 8 weeks, hematoxylin and eosin (H&E)-stained specimens were evaluated for host tissue response. Statistical significance (P < 0.05) was determined using a one-way analysis of variance (ANOVA) with Fisher's least significant difference (LSD) post hoc test. RESULTS: Composix™ with FS only showed significantly greater cellular infiltration than with suture + FS (P = 0.0007), Proceed™ with FS only had significantly greater neovascularization than with suture + FS (P = 0.0172), and ProLite Ultra™ with suture + FS had significantly greater neovascularization than with tacks only (P = 0.046). Differences due to mesh type showed that Composix™ exhibited less extensive cellular infiltration (P ≤ 0.0032), extracellular matrix (ECM) deposition, and neovascularization, and demonstrated less inflammatory cells and more fibroblasts compared to the other meshes (P < 0.05). CONCLUSIONS: FS did not have a significant histologic effect compared to tacks when utilized for the fixation of mesh to the peritoneum of New Zealand White rabbits. However, the mesh type did have a significant histologic effect. The permanent barrier mesh (Composix™) was associated with less histologic incorporation than absorbable barrier and macroporous meshes, as evidenced by lower levels of cellular infiltration, ECM deposition, and neovascularization, independent of the fixation method used.


Assuntos
Implantes Absorvíveis , Peritônio/anatomia & histologia , Peritônio/patologia , Telas Cirúrgicas , Adesivos Teciduais , Implantes Absorvíveis/efeitos adversos , Análise de Variância , Animais , Materiais Revestidos Biocompatíveis , Matriz Extracelular/metabolismo , Teste de Materiais , Neovascularização Fisiológica , Peritônio/irrigação sanguínea , Peritonite/etiologia , Polipropilenos , Coelhos , Telas Cirúrgicas/efeitos adversos , Suturas , Adesivos Teciduais/efeitos adversos
2.
Hernia ; 15(4): 423-31, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21279663

RESUMO

PURPOSE: To evaluate the biocompatibility of heavyweight polypropylene (HWPP), lightweight polypropylene (LWPP), and monofilament knit polytetrafluoroethylene (mkPTFE) mesh by comparing biomechanics and histologic response at 1, 3, and 5 months in a porcine model of incisional hernia repair. METHODS: Bilateral full-thickness abdominal wall defects measuring 4 cm in length were created in 27 Yucatan minipigs. Twenty-one days after hernia creation, animals underwent bilateral preperitoneal ventral hernia repair with 8 × 10 cm pieces of mesh. Repairs were randomized to Bard(®)Mesh (HWPP, Bard/Davol, http://www.davol.com), ULTRAPRO(®) (LWPP, Ethicon, http://www.ethicon.com), and GORE(®)INFINIT Mesh (mkPTFE, Gore & Associates, http://www.gore.com). Nine animals were sacrificed at each timepoint (1, 3, and 5 months). At harvest, a 3 × 4 cm sample of mesh and incorporated tissue was taken from the center of the implant site and subjected to uniaxial tensile testing at a rate of 0.42 mm/s. The maximum force (N) and tensile strength (N/cm) were measured with a tensiometer, and stiffness (N/mm) was calculated from the slope of the force-versus-displacement curve. Adjacent sections of tissue were stained with hematoxylin and eosin (H&E) and analyzed for inflammation, fibrosis, and tissue ingrowth. Data are reported as mean ± SEM. Statistical significance (P < 0.05) was determined using a two-way ANOVA and Bonferroni post-test. RESULTS: No significant difference in maximum force was detected between meshes at any of the time points (P > 0.05 for all comparisons). However, for each mesh type, the maximum strength at 5 months was significantly lower than that at 1 month (P < 0.05). No significant difference in stiffness was detected between the mesh types or between timepoints (P > 0.05 for all comparisons). No significant differences with regard to inflammation, fibrosis, or tissue ingrowth were detected between mesh types at any time point (P > 0.09 for all comparisons). However, over time, inflammation decreased significantly for all mesh types (P < 0.001) and tissue ingrowth reached a slight peak between 1 and 3 months (P = 0.001) but did not significantly change thereafter (P > 0.09). CONCLUSIONS: The maximum tensile strength of mesh in the abdominal wall decreased over time for HWPP, LWPP, and mkPTFE mesh materials alike. This trend may actually reflect inability to adequately grip specimens at later time points rather than any mesh-specific trend. Histologically, inflammation decreased with time (P = 0.000), and tissue ingrowth increased (P = 0.019) for all meshes. No specific trends were observed between the polypropylene meshes and the monofilament knit PTFE, suggesting that this novel construction may be a suitable alternative to existing polypropylene meshes.


Assuntos
Parede Abdominal/patologia , Hérnia Ventral/cirurgia , Polipropilenos , Politetrafluoretileno , Telas Cirúrgicas , Análise de Variância , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Elasticidade , Inflamação/patologia , Teste de Materiais , Polipropilenos/efeitos adversos , Politetrafluoretileno/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Suínos , Resistência à Tração , Fatores de Tempo
3.
Hernia ; 15(2): 157-64, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21222009

RESUMO

PURPOSE: Biologic meshes have unique physical properties as a result of manufacturing techniques such as decellularization, crosslinking, and sterilization. The purpose of this study is to directly compare the biocompatibility profiles of five different biologic meshes, AlloDerm(®) (non-crosslinked human dermal matrix), PeriGuard(®) (crosslinked bovine pericardium), Permacol(®) (crosslinked porcine dermal matrix), Strattice(®) (non-crosslinked porcine dermal matrix), and Veritas(®) (non-crosslinked bovine pericardium), using a porcine model of ventral hernia repair. METHODS: Full-thickness fascial defects were created in 20 Yucatan minipigs and repaired with the retromuscular placement of biologic mesh 3 weeks later. Animals were euthanized at 1 month and the repair sites were subjected to tensile testing and histologic analysis. Samples of unimplanted (de novo) meshes and native porcine abdominal wall were also analyzed for their mechanical properties. RESULTS: There were no significant differences in the biomechanical characteristics between any of the mesh-repaired sites at 1 month postimplantation or between the native porcine abdominal wall without implanted mesh and the mesh-repaired sites (P > 0.05 for all comparisons). Histologically, non-crosslinked materials exhibited greater cellular infiltration, extracellular matrix (ECM) deposition, and neovascularization compared to crosslinked meshes. CONCLUSIONS: While crosslinking differentiates biologic meshes with regard to cellular infiltration, ECM deposition, scaffold degradation, and neovascularization, the integrity and strength of the repair site at 1 month is not significantly impacted by crosslinking or by the de novo strength/stiffness of the mesh.


Assuntos
Parede Abdominal/patologia , Materiais Biocompatíveis , Hérnia Ventral/cirurgia , Teste de Materiais , Pele Artificial , Alicerces Teciduais , Parede Abdominal/cirurgia , Animais , Fenômenos Biomecânicos , Feminino , Modelos Animais , Maleabilidade , Suínos , Resistência à Tração
4.
Hernia ; 14(5): 505-9, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20454989

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the acute fixation strength of fibrin sealant as an alternative fixation method for laparoscopic ventral hernia repair (LVHR) when utilized with absorbable and nonabsorbable barrier meshes. METHODS: Representative mesh types for LVHR included one nonabsorbable barrier mesh (Bard Composix) and three absorbable barrier meshes (Sepramesh, Proceed, and Parietex Composite Mesh). Macroporous polypropylene mesh (Prolite Ultra) served as a control. An associated pilot study demonstrated that acute fixation was not achieved with C-Qur or Dualmesh, thus these meshes were not subjected to further analysis. Two fibrin sealants varying in thrombin concentration (TISSEEL 500 IU/ml or ARTISS 4 IU/ml) were each utilized to secure a 3 x 4 cm piece of mesh to the peritoneal surface of harvested abdominal wall from New Zealand white rabbits. Ten samples were prepared for each mesh and fibrin sealant combination. The resulting mesh-tissue interface (3 x 3 cm) underwent lap shear testing at a rate of 0.42 mm/s using a tensiometer (Instron 5542, Norwood, MA). The maximum load sustained by the construct was recorded as the acute fixation strength in units of Newtons (N). Data are given as means +/- SEM. Statistical significance (P < 0.05) was determined using a two-way ANOVA and Bonferroni post-test. RESULTS: There was no significant difference (P > 0.05) in the acute fixation strength achieved by ARTISS versus TISSEEL with Composix, Sepramesh, Proceed, and Parietex Composite Mesh. However, Prolite Ultra fixed with ARTISS (7.099 +/- 1.01 N) had a significantly higher tensile strength (P < 0.001) than Prolite Ultra fixed with TISSEEL (3.405 +/- 0.72 N). Among meshes fixed with TISSEEL, Parietex Composite (3.936 +/- 0.73 N) was significantly stronger than Sepramesh (1.760 +/- 0.33 N) (P < 0.05). CONCLUSIONS: Acute fixation strength is equivalent for TISSEEL and ARTISS fibrin sealants for selected nonabsorbable (Composix) and absorbable barrier-coated (Sepramesh, Proceed, and Parietex Composite Mesh) meshes. Previous evaluations in this model indicated fibrin sealant alone did not appear to be a suitable method of fixation with C-Qur or DualMesh against the peritoneum. Long-term evaluation is needed to evaluate the efficacy of this method of fixation using absorbable and nonabsorbable barrier-coated meshes in a model of LVHR.


Assuntos
Materiais Revestidos Biocompatíveis , Hérnia Ventral/cirurgia , Teste de Materiais/métodos , Polipropilenos , Politetrafluoretileno , Telas Cirúrgicas , Animais , Modelos Animais de Doenças , Adesivo Tecidual de Fibrina , Laparoscopia/métodos , Desenho de Prótese , Coelhos , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA