Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Environ Manage ; 253: 109685, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31654928

RESUMO

The efficacy of a baffled osmotic membrane bioreactor-microfiltration (OMBR-MF) hybrid system equipped with thin film forward osmosis membrane for wastewater treatment was evaluated at laboratory scale. The novel OMBR-MF hybrid system involved baffles, that separate oxic and anoxic zones in the aerobic reactor for simultaneous nitrification and denitrification (SND), and a bioreactor comprised of thin film composite-forward osmosis (TFC-FO) and polyether sulfone-microfiltration (PES-MF) membranes. The evaluation was conducted under four different oxic-anoxic cycle patterns. Changes in flux, salinity build-up, and microbial activity (e.g., extracellular polymeric substances (EPS) were assessed. Over the course of a 34 d test, the OMBR-MF hybrid system achieved high removal of total organic carbon (TOC) (86-92%), total nitrogen (TN) (63-76%), and PO4-P (57-63%). The oxic-anoxic cycle time of 0.5-1.5 h was identified to be the best operating condition. Incorporation of MF membrane effectively alleviated salinity build-up in the reactor, allowing stable system operation.


Assuntos
Águas Residuárias , Purificação da Água , Reatores Biológicos , Desnitrificação , Membranas Artificiais , Nitrificação , Nitrogênio , Osmose
2.
Chemosphere ; 288(Pt 3): 132610, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34678340

RESUMO

Achieving high water recovery using reverse osmosis membranes is challenging during water recycling because the increased concentrations of organics and inorganics in wastewater can cause rapid membrane fouling, necessitating frequent cleaning using chemical agents. This study evaluated the potential of membrane distillation to purify reverse osmosis-concentrated wastewater and achieve 98% overall water recovery for potable water reuse. The results indicate that membrane fouling during membrane distillation treatment was low (4% reduction in permeability) until 98% water recovery. In contrast, membrane fouling during reverse osmosis treatments was high (73% reduction in permeability) before reaching 90% water recovery. Furthermore, membrane distillation showed superior performance in removing dissolved ions (99.9%) from wastewater as compared with reverse osmosis (98.9%). However, although membrane distillation removed most trace organic chemicals tested in this study, a negligible rejection (11%) was observed for N-nitrosodimethylamine, a disinfection byproduct regulated in potable water reuse. In contrast, RO treatment exhibited a high removal of N-nitrosodimethylamine (70%). Post-treatment (e.g., advanced oxidation) after reverse osmosis and membrane distillation may be needed to comply with the N-nitrosodimethylamine regulations. Overall, the membrane distillation process had the capacity to purify reverse osmosis concentrate with insignificant membrane fouling.


Assuntos
Água Potável , Purificação da Água , Destilação , Membranas Artificiais , Osmose , Águas Residuárias
3.
Chemosphere ; 265: 129056, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33272664

RESUMO

Membrane fouling is a major challenge toward achieving direct nanofiltration (NF) treatment of surface water. This study aimed to evaluate the potential of the novel submerged flat-sheet NF membrane module to achieve low fouling propensity and high separation performance during the direct filtration of surface water. Laboratory-scale NF tests showed that the transmembrane pressure (TMP) increased only by 10 kPa over 24 d during the direct treatment of river and dam water. The NF system showed high (>80%) and stable rejection of color and organics, as well as low and variable conductivity rejection (28-47%). The rejection of negatively charged trace organic chemicals (TOrCs) was >50%, while that of uncharged or positively charged TOrCs was <50%. Another NF test that was conducted at a drinking water treatment plant showed negligible membrane fouling with a TMP increase of 3 kPa over 35 d. Separation performance of the NF system remained high: total organic carbon (TOC) removal was >70%, which was greater than the conventional rapid sand filtration system with powdered activated carbon and intermediate chlorine doses (TOC removal = 20-60%). Overall, this study demonstrated high water quality and stable system operation of the submerged flat-sheet NF system during direct treatment of surface water.


Assuntos
Água Potável , Purificação da Água , Filtração , Membranas Artificiais , Compostos Orgânicos/análise
4.
Sci Total Environ ; 714: 136768, 2020 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-31982761

RESUMO

Real-time bacteriological counting technology is capable of providing an online profile of bacterial removal during the wastewater treatment process, and can enhance the safety of recycled water for potable water reuse. However, autofluorescence emanating from dissolved organic compounds present in treated wastewater interferes with the analysis. In this study, a novel approach is adopted, viz., dialysis treatment for the removal of dissolved interfering substances from treated wastewater, and the efficiency of this treatment protocol is evaluated as a pre-treatment technique for real-time bacteriological counting. Dialysis using membranes having a molecular weight cut-off (MWCO) of 1000 kDa and 6-8 kDa were found to successfully reduce the intensity of autofluorescence emitted from the interfering substances; whereas the courser dialysis membrane having a MWCO of 1000 kDa was found to be more effective in removing the interfering substances. Here we demonstrate for the first time that continuous online dialysis treatment aids in the direct determination of the bacterial counts in ultrafiltration- and membrane bioreactor-treated wastewaters. The results of the study indicate that the dialysis pre-treatment technique is effective for continuously reducing the concentration of interfering substances in treated wastewater, and thus allows for direct online counting of bacteria.


Assuntos
Carga Bacteriana , Reatores Biológicos , Diálise , Membranas Artificiais , Ultrafiltração , Águas Residuárias , Purificação da Água
5.
Chemosphere ; 257: 127263, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32512337

RESUMO

Pre-concentration of wastewater using a forward osmosis (FO) membrane prior to processing by an anaerobic digester can enhance biogas production. However, biofouling caused by microbes in wastewater remains a challenge. The study aimed to evaluate the efficacy of chloramination in mitigating the biofouling of an FO membrane during a single-pass concentration of primary wastewater effluent. Pre-disinfection at a chloramine dose of 22-121 mg/L successfully alleviated membrane fouling. Bacterial cell counts in the feed and concentrate showed that most of the bacterial cells in the wastewater were trapped on the membrane surface or spacer. The FO membrane surfaces in non-chloraminated/chloraminated systems were fully-covered by intact/damaged bacterial cells, respectively, indicating that chloramination effectively mitigated biofouling. However, due to high permeate-recovery and low cross-flow velocity in a single-pass concentration process, organic fouling on the membrane surface (and possibly on the interior wall of the membrane-pores) appeared to cause a gradual reduction in permeate-flux. This study demonstrated successful biofouling control using chloramination during a single-pass and high-recovery pre-concentration of primary wastewater effluent.


Assuntos
Eliminação de Resíduos Líquidos/métodos , Incrustação Biológica , Cloraminas , Membranas Artificiais , Osmose , Águas Residuárias , Purificação da Água
6.
Sci Total Environ ; 667: 540-544, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30833252

RESUMO

Safety of potable reuse can be enhanced by improved water quality monitoring techniques for assessing water treatment processes. This study evaluated the efficacy of online bacterial counting for continuous monitoring of reverse osmosis (RO) membranes to remove bacteria using real-time bacteriological commercial counters and an on-site pilot-scale RO system. Prior to on-site assessments, the online bacterial counting was verified by comparing the measurement of fluorescent particles in water with flow cytometry. During a seven day pilot test of RO treatment at a water reclamation plant, online bacterial counts in RO permeate were monitored below 15 counts/mL; whereas the bacterial counts in RO feed water were approximately 2500 to 10,000 counts/mL. Removal rates of bacterial counts ranged from 2.6 to 3.1-log (average = 2.9-log) by continuously monitoring bacterial removal. This is greater than a 2-log reduction frequently determined using other water quality surrogates (i.e., electrical conductivity). Overall, the continuous monitoring of bacteria in RO feed and permeate can be implemented without the addition of chemicals to provide near real-time bacterial counts to measure their reduction after RO treatment. This can be developed for continuous performance monitoring of the RO process, providing greater assurance of microbial water quality after RO treatment.


Assuntos
Eliminação de Resíduos Líquidos/métodos , Microbiologia da Água , Filtração , Membranas Artificiais , Osmose , Purificação da Água/métodos , Qualidade da Água
7.
Chemosphere ; 200: 80-85, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29475031

RESUMO

The security of recycled water quality in potable reuse can be enhanced by improving the credibility of reverse osmosis (RO) treatment for the removal of trace organic chemicals (TOrCs). This study evaluated the potential of online monitoring of N-nitrosodimethylamine (NDMA) before and after RO treatment as a surrogate indicator for TOrC removal by RO. This pilot-scale study monitored NDMA concentrations in RO feedwater (ultrafiltration-treated wastewater) and RO permeate every 22 min using novel online NDMA analyzers-high-performance liquid chromatography followed by photochemical reaction and chemiluminescence detection. NDMA rejection by RO varied considerably in response to changes in operating conditions (permeate flux and feedwater temperature). A high linear correlation between NDMA rejection and the rejection of six other TOrCs was observed. The linear correlation was also identified for an RO membrane damaged with chlorine. The correlation between another potential surrogate indicator (conductivity rejection) and TOrC rejection was relatively low. NDMA, which is the smallest compound among regulated TOrCs, revealed rejections lower than the other TOrCs, indicating that NDMA rejection can be a conservative surrogate indicator capable of predicting changes in TOrC removal.


Assuntos
Dimetilnitrosamina/análise , Dimetilnitrosamina/química , Limite de Detecção , Osmose , Purificação da Água/métodos , Qualidade da Água , Dimetilnitrosamina/isolamento & purificação , Filtração , Membranas Artificiais , Padrões de Referência , Águas Residuárias/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/normas
8.
Water Res ; 131: 45-51, 2018 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-29268083

RESUMO

Direct potable reuse is becoming a feasible option to cope with water shortages. It requires more stringent water quality assurance than indirect potable reuse. Thus, the development of a high-rejection reverse osmosis (RO) membrane for the removal of one of the most challenging chemicals in potable reuse - N-nitrosodimethylamine (NDMA) - ensures further system confidence in reclaimed water quality. This study aimed to achieve over 90% removal of NDMA by modifying three commercial and one prototype RO membrane using heat treatment. Application of heat treatment to a prototype membrane resulted in a record high removal of 92% (1.1-log) of NDMA. Heat treatment reduced conductivity rejection and permeability, while secondary amines, selected as N-nitrosamine precursors, were still well rejected (>98%) regardless of RO membrane type. This study also demonstrated the highly stable separation performance of the heat-treated prototype membrane under conditions of varying feed temperature and permeate flux. Fouling propensity of the prototype membrane was lower than a commercial RO membrane. This study identified a need to develop highly selective RO membranes with high permeability to ensure the feasibility of using these membranes at full scale.


Assuntos
Dimetilnitrosamina/isolamento & purificação , Membranas Artificiais , Purificação da Água/métodos , Osmose , Permeabilidade , Temperatura , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/instrumentação , Qualidade da Água
9.
Artigo em Inglês | MEDLINE | ID: mdl-30261685

RESUMO

Pre-concentration is essential for energy and resource recovery from municipal wastewater. The potential of forward osmosis (FO) membranes to pre-concentrate wastewater for subsequent biogas production has been demonstrated, although biofouling has also emerged as a prominent challenge. This study, using a cellulose triacetate FO membrane, shows that chloramination of wastewater in the feed solution at 3⁻8 mg/L residual monochloramine significantly reduces membrane biofouling. During a 96-h pre-concentration, flux in the chloraminated FO system decreased by only 6% and this flux decline is mostly attributed to the increase in salinity (or osmotic pressure) of the feed due to pre-concentration. In contrast, flux in the non-chloraminated FO system dropped by 35% under the same experimental conditions. When the feed was chloraminated, the number of bacterial particles deposited on the membrane surface was significantly lower compared to a non-chloraminated wastewater feed. This study demonstrated, for the first time, the potential of chloramination to inhibit bacteria growth and consequently biofouling during pre-concentration of wastewater using a FO membrane.


Assuntos
Incrustação Biológica/prevenção & controle , Cloraminas/química , Filtração/métodos , Osmose , Águas Residuárias/química , Purificação da Água/métodos , Concentração de Íons de Hidrogênio , Japão , Membranas Artificiais
10.
Water Res ; 118: 187-195, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28431351

RESUMO

The impact of fouling substances on the rejection of four N-nitrosamines by a reverse osmosis (RO) membrane was evaluated by characterizing individual organic fractions in a secondary wastewater effluent and deploying a novel high-performance liquid chromatography-photochemical reaction-chemiluminescence (HPLC-PR-CL) analytical technique. The HPLC-PR-CL analytical technique allowed for a systematic examination of the correlation between the fouling level and the permeation of N-nitrosamines in the secondary wastewater effluent and synthetic wastewaters through an RO membrane. Membrane fouling caused by the secondary wastewater effluent led to a notable decrease in the permeation of N-nitrosodimethylamine (NDMA) while a smaller but nevertheless discernible decrease in the permeation of N-nitrosomethylethylamine (NMEA), N-nitrosopyrrolidine (NPYR) and N-nitrosomorpholine (NMOR) was also observed. Fluorescence spectrometry analysis revealed that major foulants in the secondary wastewater effluent were humic and fulvic acid-like substances. Analysis using the size exclusion chromatography technique also identified polysaccharides and proteins as additional fouling substances. Thus, further examination was conducted using solutions containing model foulants (i.e., sodium alginate, bovine serum albumin, humic acid and two fulvic acids). Similar to the secondary wastewater effluent, membrane fouling with fulvic acid solutions resulted in a decrease in N-nitrosamine permeation. In contrast, membrane fouling with the other model foulants resulted in a negligible impact on N-nitrosamine permeation. Overall, these results suggest that the impact of fouling on the permeation of N-nitrosamines by RO is governed by specific small organic fractions (e.g. fulvic acid-like organics) in the secondary wastewater effluent.


Assuntos
Membranas Artificiais , Nitrosaminas , Purificação da Água , Filtração , Osmose
11.
Water Res ; 47(16): 6141-8, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24008222

RESUMO

This study aims to provide longitudinal and spatial insights to the rejection of N-nitrosamines by reverse osmosis (RO) membranes during sampling campaigns at three full-scale water recycling plants. Samples were collected at all individual filtration stages as well as at a cool and a warm weather period to elucidate the impact of recovery and feed temperature on the rejection of N-nitrosamines. N-nitrosodimethylamine (NDMA) was detected in all RO feed samples varying between 7 and 32 ng/L. Concentrations of most other N-nitrosamines in the feed solutions were determined to be lower than their detection limits (3-5 ng/L) but higher concentrations were detected in the feed after each filtration stage. As a notable exception, in one plant, N-nitrosomorpholine (NMOR) was observed at high concentrations in RO feed (177-475 ng/L) and permeate (34-76 ng/L). Overall rejection of NDMA among the three RO systems varied widely from 4 to 47%. Data presented here suggest that the feed temperature can influence rejection of NDMA. A considerable variation in NDMA rejection across the three RO stages (14-78%) was also observed. Overall NMOR rejections were consistently high ranging from 81 to 84%. On the other hand, overall rejection of N-nitrosodiethylamine (NDEA) varied from negligible to 53%, which was considerably lower than values reported in previous laboratory-scale studies. A comparison between results reported here and the literature indicates that there can be some discrepancy in N-nitrosamine rejection data between laboratory- and full-scale studies probably due to differences in water recoveries and operating conditions (e.g. temperature, membrane fouling, and hydraulic conditions).


Assuntos
Membranas Artificiais , Nitrosaminas/química , Purificação da Água/métodos , Filtração , Osmose
12.
Bioresour Technol ; 141: 41-5, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23415945

RESUMO

This study investigated the fate of eight N-nitrosamines during membrane bioreactor (MBR) treatment. The results suggest that biodegradation is mainly responsible for the removal of N-nitrosamines during MBR treatment. Other removal mechanisms were insignificant (e.g. adsorption to sludge) or not expected (e.g. photolysis and volatilization) given the experimental conditions and physicochemical properties of the N-nitrosamines studied here. N-nitrosamine removal efficiencies were from 24% to 94%, depending on their molecular properties. High removal of N-nitrosamines such as N-nitrosodimethylamine and N-nitrosodiethylamine could be explained by the presence of strong electron donating functional groups (EDG) in their structure. In contrast, N-nitrosomorpholine possessing the weak EDG morpholine was persistent to biodegradation. The removal efficiency of N-nitrosomorpholine was 24% and was the lowest amongst all N-nitrosamines investigated in this study.


Assuntos
Nitrosaminas/química , Poluentes da Água/análise , Adsorção , Reatores Biológicos , Membranas Artificiais , Nitrosaminas/análise , Esgotos , Poluentes da Água/química , Purificação da Água/métodos
13.
Intern Med ; 49(18): 1987-90, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20847504

RESUMO

We report a case of type 1 diabetes onset and recurrence of Graves' disease during pegylated interferon (PEG-IFN)-alpha plus ribavirin treatment for chronic hepatitis C. The patient was a 55-year-old woman diagnosed with chronic hepatitis at age 46 years. She was treated for Graves' disease at 50 years of age. Because Graves' disease remitted, PEG-IFN-alpha plus ribavirin treatment was started for chronic hepatitis C. She was examined because of complaints of general fatigue, weight loss, and palpitations after 24 weeks of the treatment. She was diagnosed with a recurrence of Graves' disease, and methimazole treatment was started. However, she complained of malaise, thirst, polyuria, and loss of body weight. Her fasting blood glucose level was 292 mg/dL and HbA1c was 9.3%. Serum anti-GAD (glutamic acid decarboxylase) antibodies were 2.2 U/mL. She was diagnosed with type 1 diabetes with ketosis, and insulin treatment was started. Serum anti-GAD antibodies gradually increased to 15.1 U/mL. Graves' disease and type 1 diabetes are often complicated, and the coincidental occurrence of these 2 diseases is known as autoimmune polyglandular syndrome type III. However, only a few cases have shown that these diseases occur after IFN treatment.


Assuntos
Diabetes Mellitus Tipo 1/induzido quimicamente , Doença de Graves/induzido quimicamente , Hepatite C Crônica/tratamento farmacológico , Interferon-alfa/efeitos adversos , Polietilenoglicóis/efeitos adversos , Ribavirina/efeitos adversos , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/diagnóstico , Quimioterapia Combinada , Feminino , Doença de Graves/complicações , Doença de Graves/diagnóstico , Hepatite C Crônica/complicações , Hepatite C Crônica/diagnóstico , Humanos , Interferon alfa-2 , Interferon-alfa/administração & dosagem , Pessoa de Meia-Idade , Poliendocrinopatias Autoimunes/induzido quimicamente , Poliendocrinopatias Autoimunes/complicações , Poliendocrinopatias Autoimunes/diagnóstico , Polietilenoglicóis/administração & dosagem , Proteínas Recombinantes , Ribavirina/administração & dosagem , Prevenção Secundária , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA