Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Prosthodont ; 28(1): e383-e394, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29855127

RESUMO

PURPOSE: The purpose of this in vitro study was to evaluate the cytotoxic and apoptotic effects of seven new-generation all-ceramic materials for CAD/CAM (Lava Ultimate [LU], VITA Mark II [VM], InCoris TZI [IC], IPS e.max CAD [EM], VITA Suprinity [VS], Cerasmart [CS], IPS Empress CAD [EC]) and six provisional materials (Protemp 4 [PT], Telio CAD [TC], CAD-Temp [CT], Telio Lab [TL], Temdent Classic [TD], Telio CS C&B [TS]) on L929 mouse fibroblast cells. MATERIALS AND METHODS: 24 disc-shaped specimens (∅ = 5 mm, h = 2 mm) were prepared from each test material. Medium extracts were collected at the 1st, 3rd, and 7th days for each group and tested using the L929 cell line. Cytotoxicity was evaluated using XTT assay, and apoptosis was determined by Annexin-V/PI staining. Data were analyzed using one-way ANOVA, Tukey's multiple comparison tests at a significance level of p < 0.05. RESULTS: The cell viability results among all-ceramic material groups after the 1st and 7th days of incubation periods showed statistically significant differences (p < 0.05). There were significant differences within the ceramic groups in different incubation periods regarding apoptosis rate (p < 0.05). Throughout the entire test period, LU and VM from the CAD/CAM all-ceramic materials and PT and TC from the provisional restoration materials showed cell viability higher than 90%. EC and TD showed the lowest cell viability and highest apoptosis rates in their own groups. For the provisional materials, there were significant differences in cell viability and apoptosis rate in all the incubation periods for each material (p < 0.05). CONCLUSIONS: Although some new-generation CAD/CAM and provisional restoration materials display slight cytotoxicity values, the results are still within the reliable range, and they can safely be used in clinical conditions.


Assuntos
Cerâmica/uso terapêutico , Fibroblastos/efeitos dos fármacos , Resinas Acrílicas/efeitos adversos , Resinas Acrílicas/uso terapêutico , Animais , Apoptose/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Cerâmica/efeitos adversos , Resinas Compostas/efeitos adversos , Resinas Compostas/uso terapêutico , Materiais Dentários/efeitos adversos , Materiais Dentários/uso terapêutico , Porcelana Dentária/efeitos adversos , Porcelana Dentária/uso terapêutico , Técnicas In Vitro , Camundongos
2.
J Prosthet Dent ; 120(4): 546-552, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29703672

RESUMO

STATEMENT OF PROBLEM: The color of resin cements and computer-aided-design and computer-aided-manufacturing (CAD-CAM) restorations may change with aging. PURPOSE: The purpose of this in vitro study was to analyze the influence of thermocycling on the color of CAD-CAM materials with underlying resin cement. MATERIAL AND METHODS: Seven different CAD-CAM materials, composite resins and glass-ceramics were cut into 0.7-mm and 1.2-mm thicknesses (n=10) and cemented with a dual-polymerizing resin cement, a light-polymerizing resin cement, and a preheated composite resin (N=420). Color values were measured by using spectrophotometry. Specimens were subjected to thermocycling (5°C and 55°C; 5000 cycles). The measured color difference (ΔE) data were analyzed by using descriptive statistics. Normality of data distribution was tested by using the Kolmogorov-Smirnov test. Three-way and 1-way ANOVA followed by the Scheffé post hoc test and unpaired 2-sample Student t test were computed to determine the significant differences among the tested parameters (α=.05). RESULTS: ΔE values were significantly influenced by the CAD-CAM material (ηp2=0.85, P<.001) and the resin composite cement (ηP2=0.03, P=.003) but were not influenced by thickness (P=.179). Significant interactions were present among thickness, cement, and CAD-CAM materials (P<.001). Vita Suprinity and GC Cerasmart showed significantly the lowest ΔE values (P<.001). The highest ΔE values were observed for IPS Empress CAD. The dual-polymerizing resin cement showed significantly lower ΔE values than the preheated composite resin (P=.003). CONCLUSIONS: Restoration materials and composite resin cement types used for cementation influence the amount of color change due to aging.


Assuntos
Resinas Compostas/uso terapêutico , Desenho Assistido por Computador , Cimentos Dentários/uso terapêutico , Planejamento de Prótese Dentária , Restauração Dentária Permanente , Pigmentação em Prótese , Humanos , Técnicas In Vitro , Temperatura
3.
Odovtos (En línea) ; 21(2): 53-62, May.-Aug. 2019. tab
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1091481

RESUMO

ABSTRACT The purpose of this study is to evaluate the effect of thermocycling on the color change of the amine-free dual-cure resin cements. IPS e.max CAD blocs were cut into specimens of 1 mm thickness (N=28) and cemented with one of the 4 different amine-free dual-cure resin cements (NX3 Nexus [NX], Kerr Dental; Variolink Esthetic DC [VE], Ivoclar Vivadent; Panavia V5 [PV], Kuraray Dental; G-CEM Linkforce [GC], GC Corporation) (n=7). A spectrophotometer was used for color measurements. Specimens were subjected to thermocycling (5°C and 55°C; 5000 and 10000 cycles). Normality of data distribution was tested by using the Kolmogorov-Smirnov test. Statistical analysis was performed using a two-way analysis of variance (ANOVA) and Tukey's multiple comparison tests at a significance level of p<0.05.∆E values were significantly influenced by the resin cements and the cycle periods (p<0.05). There were no significant differences between NX and VE groups after 5000 thermocycling, however after 10000 thermocycling VE group showed higher ∆E1 values than NX group (p>0.05). There were no statistically significant differences between the ∆E0 and ∆E1 values of the GC group, however the other groups were affected after 10000 thermocycling (p>0.05). Amine-free resin cements used for cementation showed color change after thermocycling except GC group. All resin cements were showed clinically acceptable color change after thermocycling (∆E<3.5).


RESUMEN El propósito de este estudio es evaluar el efecto del termociclaje en el cambio de color de los cementos de resina de doble curado sin aminas. Los bloques IPS e.max CAD se cortaron en muestras de 1 mm de espesor (N=28) y se cementaron con uno de los 4 diferentes cementos de resina de curado doble libres de aminas (NX3 Nexus [NX], Kerr Dental; Variolink Esthetic DC [VE], Ivoclar Vivadent; Panavia V5 [PV], Kuraray Dental; G-CEM Linkforce [GC], GC Corporation) (n=7). Se usó un espectrofotómetro para las mediciones de color. Las muestras se sometieron a termociclaje (5°C y 55°C; 5000 y 10000 ciclos). La normalidad de la distribución de datos se probó utilizando la prueba de Kolmogorov-Smirnov. El análisis estadístico se realizó mediante un análisis de varianza de dos vías (ANOVA) y las pruebas de comparación múltiple de Tukey a un nivel de significación de p<0.05. Los valores de ∆E fueron significativamente influenciados por los cementos de resina y los períodos de ciclo (p<0.05). No hubo diferencias significativas entre los grupos NX y VE después de 5000 termociclos, sin embargo, después de 10000, el grupo VE mostró valores ∆E1 mayores que el grupo NX (p>0.05). No hubo diferencias estadísticamente significativas entre los valoresn∆E0 y ∆E1 del grupo GC, no obstante, los otros grupos se vieron afectados después de 10000 termociclos (p>0.05). Cementos de resina libres de aminas. utilizados para la cementación mostró cambio de color después del termociclaje, excepto el grupo GC. Todos los cementos de resina mostraron un cambio de color clínicamente aceptable después del termociclaje (∆E<3.5).


Assuntos
Pigmentação em Prótese , Cimentos de Resina , Envelhecimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA