Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Prosthet Dent ; 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38228448

RESUMO

STATEMENT OF PROBLEM: Visual shade selection in dentistry may be influenced by factors that include the background color and the illuminant. PURPOSE: The purpose of this clinical study was to evaluate the influence of using a gray background and a light-correcting device on visual shade selection. MATERIAL AND METHODS: Two experienced clinicians assessed the incisor color of 30 volunteers using the VITA 3D-MASTER shade guide. Visual analyses were carried out using or not (control) a gray background, with and without (control) a light-correcting device (Smile Lite). Furthermore, the use of a polarizing filter was evaluated. Data from a clinical spectrophotometer were defined as the standard instrumental analysis. The agreement and the similarity (based on the whitening indexes of tabs) were evaluated between instrumental and visual analyses. Statistical testing was conducted through ordinal logistic regression and repeated-measures ANOVA. The Shapiro-Wilk test was used to confirm the data distribution, and homogeneity of variance was assessed with the Levene test (α=.05) RESULTS: The use of Smile Lite resulted in lighter tabs than indicated by the instrumental analysis, and the opposite was observed in its absence. The polarizing filter did not affect the results (P>.05). For similarity, the illuminant improved the results (P<.001). The gray background reduced the differences between visual and instrumental analysis only in the absence of the Smile Lite (P<.001). CONCLUSIONS: The color similarity between visual and instrumental analysis improved with the use of a light-correcting device with or without a polarization filter. A gray background was useful only without the light-correcting device.

2.
Rev. Flum. Odontol. (Online) ; 1(63): 1-12, jan-abr. 2024.
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: biblio-1566732

RESUMO

A hiperpigmentação melânica ocorre devido à deposição anormal de melanina na camada basal e suprabasal do epitélio, criando uma aparência escurecida. É fisiológica, por isso não representa dano à saúde, podendo ser apenas uma queixa estética do paciente. O objetivo deste trabalho foi realizar uma revisão de literatura narrativa sobre o uso da técnica cirúrgica com bisturi, da abrasão com instrumento rotatório e da ablação com laser como métodos para realizar a remoção da hiperpigmentação melânica gengival de etiologia fisiológica. Muitas técnicas têm sido utilizadas para fazer a despigmentação, diferentes resultados e fatores, como conforto do paciente, cuidado pós-operatório e recorrência, têm sido apresentados. A técnica cirúrgica com bisturi é considerada o padrão ouro devido aos seus bons resultados, material de fácil acesso e baixo custo. A abrasão com instrumentos rotatórios não requer nenhum equipamento ou material sofisticado, é relativamente simples e segura. E a terapia a laser é uma modalidade de tratamento eficaz, minimamente invasiva, com trans e pós-operatório confortável. Entretanto, são necessários mais estudos sobre o uso da abrasão com instrumento rotatório que acompanhem os pacientes em longo prazo e pesquisas que descrevam o uso e resultados proporcionados pelos diversos tipos de laser de alta potência. Tendo em vista a presente revisão de literatura pode-se concluir que a repigmentação não ocorre por uma média de um a dois anos. Porém, são necessários mais estudos para especificar qual técnica apresenta menor índice de repigmentação.


Melanic hyperpigmentation occurs due to abnormal deposition of melanin in the basal and suprabasal layers of the epithelium, creating a darkened appearance. It is physiological, so it does not represent harm to health, and may be just an aesthetic complaint by the patient. The objective of this work was to carry out a narrative literature review on the use of surgical technique with a scalpel, abrasion with a rotary instrument and laser ablation as methods to remove gingival melanin hyperpigmentation of physiological etiology. Many techniques have been used to perform depigmentation, different results and factors, such as patient comfort, postoperative care and recurrence, have been presented. The surgical technique with a scalpel is considered the gold standard due to its good results, easily accessible material and low cost. Abrasion with rotary instruments does not require any sophisticated equipment or material, is relatively simple and safe. And laser therapy is an effective treatment modality, minimally invasive, with comfortable trans and postoperative. However, more studies are needed on the use of abrasion with a rotary instrument to monitor patients in the long term and research that describe the use and results provided by the different types of high-power lasers. In view of the present literature review, it can be concluded that repigmentation does not occur for an average of one to two years. However, further studies are needed to specify wich technique has the lowest rate of repigmentation.


Assuntos
Hiperpigmentação , Terapia a Laser/métodos
3.
Rev. Flum. Odontol. (Online) ; 3(65): 31-50, set-dez.2024.
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: biblio-1567828

RESUMO

A sociedade está cada vez mais exigente e em busca de excelência quando o assunto é estética facial. O sorriso tem grande impacto na harmonia da face e, atualmente, os pacientes estão mais conscientes sobre a influência da gengiva na beleza do sorriso. A exposição da gengiva em excesso, conhecida como sorriso gengival, afeta a estética, podendo interferir na autoestima e nas relações sociais dos pacientes. Existem diversos procedimentos descritos para solucionar o problema e, para o planejamento do caso e escolha do método, é preciso determinar a etiologia e levar em consideração o desejo do paciente. A injeção da proteína botulínica é uma alternativa minimamente invasiva que está sedo cada vez mais utilizada para a correção do sorriso gengival. Com isso, o objetivo do presente trabalho monográfico foi realizar uma revisão de literatura sobre o uso da toxina botulínica na correção do sorriso gengival, analisando técnicas de injeção, identificando o efeito imediato e a longo prazo da toxina nos músculos elevadores do lábio superior, além de avaliar a relevância desse método na correção do sorriso gengival, sozinho ou em conjunto com outros procedimentos. Foi realizada uma revisão de literatura nas bases de dados PubMed e Scielo, buscando artigos dos anos de 2013 até 2022, utilizando os descritores "botulinum toxin", "botox", "gummy smile", "gingival display" e "gingival exposure". Essa revisão analisa 15 artigos que discorrem sobre o método, durabilidade e eficácia da aplicação de proteína botulínica para correção do sorriso gengival. Algumas variantes diferenciam as técnicas de aplicação, como a marca do produto e recomendações do fabricante, classificação do sorriso e extensão da exposição gengival. Com base na revisão de literatura, pôde-se concluir que, apesar de ser transitório, esse procedimento se mostrou eficaz, tanto ao ser realizado como método principal, quanto como coadjuvante no tratamento. Além de ser comprovadamente seguro, rápido, minimamente invasivo e ser o tratamento de preferência entre os pacientes, com alto índice de satisfação, são raras as complicações relacionadas a aplicação da proteína botulínica para esse fim.


Society is becoming increasingly demanding, seeking excellence in facial aesthetics. The smile greatly impacts facial harmony, and nowadays, patients are more aware of the influence of the gums on smile beauty. Excessive gum exposure, known as gummy smile, affects aesthetics and can interfere with patients' self-esteem and social relationships. There are various procedures described to address this issue, and for case planning and method selection, it is necessary to determine the etiology and take into account the patient's desires. The injection of botulinum protein is a minimally invasive alternative that is increasingly being used for gummy smile correction. Thus, the aim of this monographic work was to conduct a literature review on the use of botulinum toxin in gummy smile correction, analyzing injection techniques, identifying the immediate and long-term effects of the toxin on the upper lip elevator muscles, and evaluating the relevance of this method in gummy smile correction, either alone or in conjunction with other procedures. A literature review was conducted in the PubMed and Scielo databases, seeking articles from 2013 to 2022, using the descriptors "botulinum toxin", "botox", "gummy smile", "gingival display", and "gingival exposure". This review analyzes 15 articles that discuss the method, durability, and effectiveness of botulinum toxin application for gummy smile correction. Some variations differentiate the application techniques, such as the product brand and manufacturer's recommendations, smile classification, and extent of gum exposure. Based on the literature review, it was possible to conclude that, despite being temporary, this procedure proved to be effective, both when performed as the main method and as an adjunct in treatment. In addition to being proven safe, fast, minimally invasive, and the preferred treatment among patients, with a high satisfaction rate, complications related to botulinum toxin application for this purpose are rare.


Assuntos
Sorriso , Toxinas Botulínicas , Resultado do Tratamento , Toxinas Botulínicas Tipo A , Gengiva
4.
Rev. Flum. Odontol. (Online) ; 3(65): 87-96, set-dez.2024. ilus
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: biblio-1567859

RESUMO

O objetivo do presente estudo foi estabelecer um protocolo clínico de aplicação do produto DSP Desensitizer Gluhem em dentes com exposição radicular sem perda de estrutura dentária, e fazer uma análise dissertativa sobre o principal componente desse produto: glutaraldeído, no tratamento da hipersensibilidade dentinária. Para isso, a paciente apresentou-se à Clínica Odontológica da UFF| Niterói ­ RJ, queixando-se de sensibilidade intensa ao frio nos elementos 13 e 34. Primeiramente, foram coletadas informações durante a anamnese, e ao exame clínico foi observada recessão gengival e exposição radicular nesses elementos, porém não havia perda de estrutura dentária. Inicialmente foi feita a avaliação do nível de dor, com uso da Escala Analógica de Dor que pontua os níveis de dor de 0 a 10, sendo 0 "nenhuma dor' e 10 "pior dor possível". Após o questionamento, fez-se a secagem da região com jato de ar e aplicou-se o dessensibilizante Gluhem em solução por toda região cervical do elemento 13 até a margem gengival por 40 segundos com posterior secagem e lavagem com água. Também foi feita a aplicação da formulação em gel no elemento 34 seguindo o mesmo protocolo. A paciente não reagiu a dor após o protocolo. Conclui-se que o produto DSP Gluhem tanto na apresentação de solução como em gel atuaram efetivamente na sintomatologia dolorosa da HDC nas duas aplicações realizadas.


The objective of the present study was to establish a clinical protocol for the application of the product GSP Desensitizer Gluhem in teeth with root exposure without loss of tooth structure, and to carry out a dissertation analysis on the main component of this product: glutaraldehyde, in the treatment of dentin hypersensitivity. For this, the patient went to the Dental Clinic of UFF| Niterói - RJ, complaining of intense sensitivity to cold in elements 13 and 34. First, information was collected during the anamnesis, and the clinical examination showed gingival recession and root exposure in these elements, but there was no loss of tooth structure. Initially, the pain level was evaluated using the Analog Pain Scale, which scores pain levels from 0 to 10, with 0 being "no pain" and 10 "worst possible pain". After questioning, the region was dried with an air jet and the desensitizing Gluhem solution was applied throughout the entire cervical region of element 13 up to the gingival margin for 40 seconds with subsequent drying and washing with water. The gel formulation was also applied to element 34 following the same protocol. The patient did not react to pain after the protocol. It is concluded that the product DSP Gluhem, both in solution and in gel presentation, effectively acted on the painful symptomatology of HDC in the two applications performed.


Assuntos
Humanos , Feminino , Adulto , Protocolos Clínicos , Glutaral/uso terapêutico , Sensibilidade da Dentina , Dessensibilizantes Dentinários
5.
Rev. Flum. Odontol. (Online) ; 1(63): 74-86, jan-abr. 2024.
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: biblio-1566914

RESUMO

Na era contemporânea, a Odontologia está cada vez mais se voltando para o meio virtual. Os indivíduos não somente querem consumir um produto ou ter acesso a um serviço, mas querem entender também sobre quem está atrás daquilo ofertado. Nesse sentido, a Odontologia teve diversos benefícios com o advento das mídias sociais e das recorrências clínicas de toda Tecnologia da Informação. Com a chegada das redes e a troca exponencial de dados, Cirurgiões Dentistas tiveram muito a ganhar com maior possibilidade de divulgação e troca de dados. Cada vez mais os profissionais liberais utilizam meios para angariar pacientes e alavancar lucros, ou, ainda, aumentar o potencial de seu trabalho, seja de cunho científico, social ou pedagógico. Analogamente, questões éticas e aspectos legais são levantadas diariamente ao analisar o uso das mídias sociais pelos profissionais, visto as infrações de princípios morais cometidos, além dos excessos que banalizam e causam a perda de toda magnitude da profissão. O objetivo desse estudo foi analisar, através de uma revisão de literatura, os impactos das mídias sociais na Odontologia, dessa forma, buscando entender como os cirurgiões-dentistas, a sociedade e o mercado têm lidado com toda a mudança trazida pela Tecnologia da Informação e suas confluências. Com base na revisão de literatura realizada, foi possível concluir que as redes sociais são ferramentas imprescindíveis para a disseminação de informações e conteúdo de valor na Odontologia, que os profissionais, os pacientes e o universo acadêmico e científico têm muito a ganhar com os recursos tecnológicos provenientes das mídias sociais, principalmente, pela sua flexibilidade, por ser um meio democrático e oferecer baixo custo. Todavia, na dualidade apresentada pelo uso das redes sociais, o seu uso precisa ser criterioso e intencional, demonstrando ser uma questão de saúde pública, que envolve aspectos éticos e legais no meio odontológico, necessitando ter sua utilização profissional mais abordada nos meios acadêmicos e científicos. Ainda, indo na contramão das atuais tendências negativas das redes sociais e da Tecnologia da Informação, a Odontologia não deve perder a sua magnitude e profundidade para se adequar nos moldes da efemeridade das mídias sociais. O saber científico e a primazia técnica devem vir ainda em primeiro lugar, mesmo que isso não favoreça os algoritmos de alcance das redes sociais ou vá de encontro a interesses mercadológicos.


In the contemporary era, dentistry is increasingly turning to the virtual environment. Individuals not only want to consume a product or have access to a service, but also want to understand who is behind what is offered. In this sense, Dentistry has had several benefits with the advent of social media and the clinical recurrences of all Information Technology. With the arrival of networks and the exponential exchange of data, Dental Surgeons had a lot to gain from greater possibilities for disseminating and exchanging data. Liberal professionals are increasingly using means to attract patients and leverage profits, or even increase the potential of their work, whether of a scientific, social or pedagogical nature. Similarly, ethical issues and legal aspects are raised daily when analyzing the use of social media by professionals, given the violations of moral principles committed, in addition to the excesses that trivialize and cause the loss of all magnitude of the profession. The objective of this study was to analyze, through a literature review, the impacts of social media on Dentistry, thus seeking to understand how dentists, society and the market have dealt with all the changes brought about by Information Technology and their confluences. Based on the literature review carried out, it was possible to conclude that social networks are essential tools for the dissemination of information and valuable content in Dentistry, that professionals, patients and the academic and scientific universe have much to gain from technological resources. from social media, mainly because of its flexibility, because it is a democratic means and offers low cost. However, in the duality presented by the use of social networks, their use needs to be judicious and intentional, proving to be a public health issue, which involves ethical and legal aspects in the dental environment, needing to have its professional use more addressed in academic and scientific circles. . Still, going against the current negative trends of social networks and Information Technology, Dentistry must not lose its magnitude and depth to adapt to the molds of the ephemerality of social media. Scientific knowledge and technical primacy must still come first, even if this does not favor social media reach algorithms or go against market interests


Assuntos
Informática Médica , Odontologia , Ética Odontológica , Mídias Sociais
6.
Rev. Flum. Odontol. (Online) ; 1(63): 180-198, jan-abr. 2024.
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: biblio-1567032

RESUMO

A Odontologia Estética baseia- se em princípios de estética com condutas e técnicas de procedência lógica, como também intuitiva, para planejar um sorriso harmônico. Com seu atual perfil mais conservador atrelado às inúmeras ferramentas disponíveis no mercado, é possível arquitetar procedimentos priorizando o sucesso do tratamento, restabelecendo a função e harmonia, com maior segurança e previsibilidade. O fluxo digital inclui Softwares e equipamentos automatizados que podem otimizar o tempo clínico, apresentando benefícios tanto para o Cirurgião Dentista como para o paciente. Atualmente, o DSD (digital smile design) tem sido utilizado como um recurso de grande destaque para a Odontologia reabilitadora, pois, possibilita um planejamento mais minucioso em cada estágio do tratamento reabilitador estético com o uso de desenhos e linhas de referência para comparações entre as imagens geradas do antes e depois, avaliando se concordam com o planejamento e anseios do profissional e do paciente, ou se serão necessárias modificações. Com isso, o objetivo do presente trabalho foi realizar uma revisão de literatura sobre os avanços do fluxo de trabalho digital em reabilitação oral estética, analisando-se a influência na qualidade do atendimento atrelado ao conforto dos pacientes. Foi realizada uma revisão de literatura nas bases de dados PubMed, Scielo e Wiley Library, utilizando os descritores "Digital Smile Design", "Dental Esthetic," EstheticTreatment". Foram buscados artigos entre 2009 até 2022. Com base na revisão de literatura, foi possível concluir que a técnica se apresenta como uma ferramenta valiosa para tratamentos restauradores, otimizando a compreensão das dificuldades estéticas e aumentando a aceitação do tratamento pelo paciente. E, por trás destes resultados, existem diversas variáveis influenciando-os, como a maior previsibilidade dos procedimentos, reduzindo o tempo para a finalização, além de trabalhos mais conservadores, com estrutura dental preservada.


Esthetic dentistry is based on aesthetic principles with logical, also intuitive procedures and techniques, in order to plan a harmonic smile. With its more consecutive current profile linked to the numerous tools available on the market, it is possible to design procedures prioritizing the success of the treatment restoring the function and harmony with greater safety and predictability. The digital flow includes software and automated equipment that can optimize clinical time, presenting benefits for both, the dental surgeon and the patient. Currently, the DSD (digital smile design) has been used as a resource of great prominence for Rehabilitative Dentistry, because it allows a more detailed planning in each stage of the aesthetic rehabilitation treatment with the use of drawings and reference lines, in order to compare between the images generated before and after the procedure, assessing whether they are in accordance with the planning and desires of the professional and the patient, or if modifications are necessary. With this, the objective of the present work was to carry out a literature review of the advances in the digital workflow in aesthetic oral rehabilitation. Analyzing the influence on the quality of care linked to the comfort of patients. A literature review was carried out in PubMed, Scielo and Wiley Library databases, using the descriptors "Digital Smile Design", "Dental Esthetic", "Esthetic Treatment". Articles were searched between 2009 and 2022. Based on the literature revie, it was possible to conclude that the technique presents itself as a valuable tool for restorative treatments, optimizing the understanding of aesthetic difficulties and increasing the acceptance of the treatment by the patient. And, behind these results, there are several variables influencing them, such as greater predictability of procedures, reducing the time for completion in addition to more conservative works, with preserved tooth structure.


Assuntos
Software , Desenho Assistido por Computador , Estética Dentária , Planejamento , Reabilitação Bucal
7.
Iran Endod J ; 11(3): 188-91, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27471529

RESUMO

INTRODUCTION: The aim of this in vitro study was to evaluate the effect of 10% citric acid and 17% ethylenediaminetetraacetic acid (EDTA) irrigating solutions on the surface morphology of young and old root dentin by determining the number and diameter of dentinal tubules using scanning electron microscopy (SEM). METHODS AND MATERIALS: Fifty healthy human teeth collected from young (≤30 years) and old (≥60 years) individuals (n=25) were first prepared with a Largo bur #2 to produce smear layer on the root canal surface. Subsequently, the crowns and the root middle and apical thirds were sectioned and removed, and the cervical thirds were sectioned vertically in the buccal-lingual direction into two equal halves. The obtained samples were then immersed in 2.5% sodium hypochlorite for 30 min and randomly separated into two treatment groups for each age group. In each age group, ten samples were selected as controls and did not receive any type of treatment. The rest of the specimens were then rinsed, dried and treated for 4 min with 10% citric acid or 17% EDTA. The samples were then assessed with SEM regarding the number and diameter of dentinal tubules. All data were assessed using Student's t-test. The level of significance was set at 0.05. RESULTS: Regardless of the type of treatment, no significant differences were observed in the number of open tubules between the young and old root dentin (P>0.05). Nonetheless, the diameter of the tubules in the old root dentin was larger when 17% EDTA was used (P<0.05). Both, young and old root dentin did not differ with the 10% citric acid treatment (P>0.05). CONCLUSION: The results showed that 17% EDTA treatment induced a significant demineralization in old root dentin.

8.
Braz Dent J ; 27(5): 492-496, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27982223

RESUMO

Bis-acryl resins are used for temporary dental restorations and have shown advantages over other materials. The aim of this work was to evaluate the in vitro cytotoxicity of two bis-acryl composite resins (Protemp 4 and Luxatemp Star), obtained at 1, 7 and 40 days after mixing the resin components, using a standardized assay employing human primary cells closely related to oral tissues. Human gingival fibroblast cell cultures were exposed for 24 h to either bis-acryl composite resins, polystyrene beads (negative control) and latex (positive control) extracts obtained after incubation by the different periods, at 37 °C under 5% CO2. Cell viability was evaluated using a multiparametric procedure involving sequential assessment (using the same cells) of mitochondrial activity (XTT assay), membrane integrity (neutral red test) and total cell density (crystal violet dye exclusion test). The cells exposed to the resin extracts showed cell viability indexes exceeding 75% after 24 h. Even when cells were exposed to extracts prepared with longer conditioning times, the bis-acryl composite resins showed no significant cytotoxic effects (p>0.05), compared to the control group or in relation to the first 24 h of contact with the products. There were no differences among the results obtained for the bis-acryl composite resins evaluated 24 h, 7 days and 40 days after mixing. It may be concluded that the bis-acryl resins Protemp 4 and Luxatemp Star were cytocompatible with human gingival fibroblasts, suggesting that both materials are suitable for use in contact with human tissues.


Assuntos
Resinas Compostas , Gengiva/citologia , Fibroblastos/citologia , Humanos
9.
Full dent. sci ; 10(38): 91-96, 2019. ilus
Artigo em Português | BBO - odontologia (Brasil) | ID: biblio-996521

RESUMO

O estudo tem como objetivo descrever e discutir um caso clínico de uma restauração em resina composta fotopolimerizável à base de Ormocer em elemento dentário posterior, detalhando o material com o intuito de melhorar o comportamento clínico das resinas compostas convencionais, apresentando inúmeras vantagens. O material baseia-se numa tecnologia de partículas vitrocerâmicas e híbridas que apresenta um conteúdo de cargas inorgânicas de 84% p/p, além disso, apresenta uma baixa tensão de contração (3,87 MPa). Sendo assim, o primeiro material de restauração direta do mundo a ser fabricado exclusivamente à base de cerâmica. AAdmira Fusionpossibilita realizar restaurações diretas exclusivamente à base de cerâmica com a mesma facilidade dos trabalhos com compósitos de boa qualidade (AU).


The aim of the present study was to describe and discuss a clinical case of restoration in an Ormocer based photopolymerized composite resin in posterior dental element, detailing the material with the intention to improve conventional composite resins clinical behavior, presenting many advantages. The material is based on a glass-ceramic and hybrid particle technology having an inorganic filler content of 84% w/w, furthermore it shows a low contraction stress (3.87 MPa). Thus being the first restoration material in the world to be exclusively ceramic-based manufactured. Admira Fusion makes it possible to perform direct exclusively ceramic-based restorations just as easily as good quality composites (AU).


Assuntos
Humanos , Feminino , Adulto , Cerâmica , Resinas Compostas , Materiais Dentários , Dentística Operatória , Brasil , Hidróxido de Cálcio , Cura Luminosa de Adesivos Dentários
10.
Pesqui. bras. odontopediatria clín. integr ; 17(1): e2918, 13/01/2017. tab, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-914287

RESUMO

Objective: To compare the bond strength of three-step and self-etch adhesive systems with and without prior acid etching on bonding of fiberglass posts in root canals. Material and Methods: Experiments were conducted on roots of five upper molars without curvature and sectioned in a cervical-apical direction. With the aid of a highspeed turbine and diamond tips, cylindrical cavities 7 mm in depth and 1.4 mm in diameter were made in the dentine. The roots of the same tooth were used, where the retainers were cemented, thus generating three groups: Group A: Adper Scotchbond Multipurpose Plus (SBMP) + Rely X ARC; Group B: Single Bond Universal (SBU-1) + Rely X ARC, with acid etching prior to adhesive insertion; Group C: Single Bond Universal (SBU-2) + Rely X ARC. The samples were stored in a bacteriological incubator at 37ºC with 100% humidity for 48h and were subsequently cross-sectioned to obtain 3 dentine discs 1mm in thickness. Forty-five specimens were subjected to the push-out test. Results: Through the analysis of variance and Tukey's test, it was found that SBMP showed, with statistical significance (p<0.05), highest bond strength when compared with the SBU-1 and SBU-2 systems. The observed difference in the discs was located in the cervical portion. Conclusion: The three-step adhesive system had higher bond strength with the substrate than the self-etching adhesive only in the disc in the cervical portion; further, statistically, the prior application of phosphoric acid in SBU-1 did not affect its bond strength significantly.


Assuntos
Condicionamento Ácido do Dente/métodos , Cimentos Dentários , Cimentos de Ionômeros de Vidro/química , Resistência à Tração , Análise de Variância , Brasil , Pinos Dentários
11.
Braz. dent. j ; 27(5): 492-496, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-828031

RESUMO

Abstract Bis-acryl resins are used for temporary dental restorations and have shown advantages over other materials. The aim of this work was to evaluate the in vitro cytotoxicity of two bis-acryl composite resins (Protemp 4 and Luxatemp Star), obtained at 1, 7 and 40 days after mixing the resin components, using a standardized assay employing human primary cells closely related to oral tissues. Human gingival fibroblast cell cultures were exposed for 24 h to either bis-acryl composite resins, polystyrene beads (negative control) and latex (positive control) extracts obtained after incubation by the different periods, at 37 °C under 5% CO2. Cell viability was evaluated using a multiparametric procedure involving sequential assessment (using the same cells) of mitochondrial activity (XTT assay), membrane integrity (neutral red test) and total cell density (crystal violet dye exclusion test). The cells exposed to the resin extracts showed cell viability indexes exceeding 75% after 24 h. Even when cells were exposed to extracts prepared with longer conditioning times, the bis-acryl composite resins showed no significant cytotoxic effects (p>0.05), compared to the control group or in relation to the first 24 h of contact with the products. There were no differences among the results obtained for the bis-acryl composite resins evaluated 24 h, 7 days and 40 days after mixing. It may be concluded that the bis-acryl resins Protemp 4 and Luxatemp Star were cytocompatible with human gingival fibroblasts, suggesting that both materials are suitable for use in contact with human tissues.


Resumo Resinas bisacrílicas são usadas em restaurações dentárias provisórias e têm mostrado vantagens em relação a outros materiais. O objetivo deste trabalho foi avaliar a citotoxicidade in vitro de duas resinas compostas bisacrílicas (Protemp 4 e Luxatemp Star), obtidas após 1, 7 e 40 dias da mistura com os componentes da resina, usando um ensaio padronizado empregando células primárias humanas fortemente relacionadas aos tecidos orais. Culturas de células de fibroblastos gengivais humanos foram expostas por 24 h aos extratos das resinas bisacrílicas, esferas de poliestireno (controle negativo) e látex (controle positivo), obtidos após diferentes períodos de incubação, a 37 °C e com 5% CO2. A viabilidade celular foi avaliada usando procedimentos multiparamétricos que envolvem a avaliação sequencial (usando as mesmas células) da atividade mitocondrial (ensaio XTT), a integridade de membrana (teste do vermelho neutro) e a densidade celular total (teste de exclusão do corante cristal violeta). As células expostas aos extratos mostraram viabilidade celular acima de 75% depois de 24 h. Mesmo quando as células foram expostas aos extratos com aumento do tempo de condicionamento, as resinas bisacrílicas não apresentaram efeitos citotóxicos significativos (p<0,05), comparadas ao grupo controle ou em relação às primeiras 24 h de contato com os produtos. Não houve diferença entre os resultados obtidos para as resinas bisacrílicas avaliadas entre as 24 h, 7 e 40 dias depois da mistura. Concluímos que as resinas bisacrílicas Protemp 4 e Luxatemp Star foram citocompatíveis com os fibroblastos gengivais humanos, sugerindo que ambos materiais são adequados para uso em contato com tecidos humanos.


Assuntos
Humanos , Resinas Compostas , Gengiva/citologia , Fibroblastos/citologia
12.
Rev. dental press estét ; 10(1): 79-88, jan.-mar .2013. ilus
Artigo em Português | LILACS | ID: lil-681621

RESUMO

Para o sucesso do tratamento odontológico, é fundamental realizar um correto diagnóstico, planejamento e execução do trabalho. Os materiais utilizados para restaurações provisórias são de grande importância na reabilitação estética anterior, pois são os guias para escolha da cor, forma e contorno da restauração final, proporcionando maior previsibilidade do resultado, tanto para o paciente quanto para o profissional. As resinas provisórias bisacrílicas tornaram-se uma escolha cada vez mais popular devido às suas melhores propriedades mecânicas, resultados estéticos e facilidade de manuseio. O presente artigo objetiva demonstrar um caso clínico onde foi utilizada resina bisacrílica para reabilitação estética provisória. Tal técnica propiciou a esse caso um satisfatório resultado parcial funcional e estético, respeitando os anseios da paciente e facilitando o sucesso final do trabalho


Introduction: For the success of dental treatment it is vital a correct diagnosis, planning and execution of work. The materials used for provisional restorations are of great importance in the anterior esthetic rehabilitation, as they are guides for choosing the color, shape and contour of the fnal restoration, proportionating greater predictability of the outcome for both patient and professional. The provisional bisacryl composite became an increasingly popular choice due to its better mechanical properties, cosmetic results and ease of handling. Objective: This article aims to demonstrate a clinical case in which it was used a bis-acrylic resin for provisional esthetic rehabilitation. Conclusion: This technique used in this case provided a satisfactory partial result, as functional as esthetic, respecting the wishes of the patient and facilitating the ultimate success of the work.


Assuntos
Humanos , Feminino , Adulto , Materiais Dentários , Prótese Dentária , Restauração Dentária Temporária , Facetas Dentárias , Estética Dentária , Reabilitação Bucal
13.
Rev. dental press estét ; 8(2): 66-76, abr.-jun. 2011. ilus
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-594769

RESUMO

O tratamento estético utilizando o clareamento dentário e restaurações com resina composta é uma excelente alternativa para a obtenção de um belo sorriso. A procura da estética pelos pacientes tem sido cada vez mais frequente, em busca de dentes claros e de um sorriso harmonioso. O clareamento dentário proporciona uma estética mais favorável, porém já é bastante elucidado que os agentes clareadores atuam somente na estrutura dentária, e não nos materiais restauradores, no que diz respeito à descoloração. Por isso, muitas vezes há a necessidade de substituir restaurações de resina composta após o tratamento clareador. O presente artigo apresenta o relato de um caso clínico em que foi realizado o clareamento dentário em consultório com peróxido de hidrogênio a 20 por cento com posterior substituição das restaurações de resina composta pela técnica estratificada, utilizando um compósito mecrohíbrido. O resultado clínico foi adequado e satisfatório, oferecendo um belo sorriso ao paciente, o que demonstra a possibilidade de se realizar os dois procedimentos, visando melhorar a estética, através de um sorriso harmonioso.


The esthetic treatment using dental bleaching and resin composite restorations is an excellent alternative to obtain a beautiful smile. Patients' demands for cosmetic have been much more often in search of bleached teeth and a bright harmonic smile. Dental bleaching provides a beautiful smile, but it is quite known that bleaching agents act only in the tooth structure and do not in restorative materials. Therefore, there is often the need to replace resin composite restorations after bleaching. This article presents a case report in which was performed a dental office bleaching with hydrogen peroxide at 20%, with subsequent replacement of resin composite restorations through the stratified technique using a micro-hybrid resin composite. Clinical outcome was adequate and satisfactory offering a beautiful smile to the patient. This demonstrates the possibility of performing both procedures, and therefore improve esthetics as the proportion of a harmonious smile.


Assuntos
Humanos , Feminino , Adulto Jovem , Resinas Compostas , Estética , Clareamento Dental , Estética Dentária
14.
Rev. flum. odontol ; 17(35): 36-40, jan.-jun. 2011. graf
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-638415

RESUMO

O objetivo deste trabalho foi avaliar o escoamento do cimento fosfato de zinco como agente de fixação. Foram utilizados dois cimentos de fosfato de zinco, o Cimento LS (Vigodent) e o Cimento de Zinco (SS White). Todos os cimentos foram testados de acordo com base na Especificação nº 8 da ADA, para o cimento fosfato de zinco. Após a manipulação, uma seringa BD com a ponta recortada foi utilizada para dispensar um volume de 0,5 ml sobre uma placa de vidro quadrangular de superfície lisa, com as dimensões 10 cm x 10 cm. Decorrido três minutos do início da manipulação, outra placa de vidro com dimensões 5 cm x 5 cm pesando 20 gramas e um peso adicional de 100 gramas foram colocados sobre a mistura de cimento, totalizando uma carga de 120 gramas. O peso foi removido dez minutos após o início da manipulação e o disco formado pelo cimento endurecido foi medido em seus diâmetros maior e menor utilizando um paquímetro eletrônico digital Starrett. Para o teste de consistência ou de escoamento cada cimento foi avaliado cinco vezes e os dados obtidos foram aproximados para o milímetro mais próximo. Os valores obtidos foram anotados e essas medidas foram somadas e divididas por dois para a obtenção de um diâmetro médio. Os valores foram submetidos à análise estatística através do teste “t” de Student e os resultados foram os seguintes: os maiores valores do diâmetro do círculo formado pelo cimento foram obtidos no Cimento LS (Vigodent) (p<0,05). Concluiu-se que o Cimento Fosfato de Zinco LS (Vigodent) apresentou maior escoamento em comparação com o Cimento de Zinco (SS White).


The aim of this study was to evaluate the flow of zinc phosphate cement as a fixing agent. We used two zinc phosphate cement, Cement LS (Vigodent) and Zinc cement (SS White). All cements were tested according to specification based on paragraph 8 of the ADA, for the zinc phosphate cement. After manipulation, a BD syringe with the tip cut was used to dispense a volume of 0.5 ml of a square glass plate with a smooth surface, with the dimensions 10 cm x 10 cm. Three minutes elapsed from the beginning of the manipulation, another glass plate with dimensions 5 cm x 5 cm and weighing 20 grams extra weight to 100 grams were weight placed on the cement mixture, with a total load of 120 grams. The weight was removed ten minutes after the start of the manipulation and the disk formed by the hardened cement was measured in its largest and smallest diameters using a digital caliper Starrett. To test the consistency or flow each cement was assessed five times and the data were approximated to the nearest millimeter. The values were recorded and these measures were summed and divided by two to obtain an average diameter. The values were statistically analyzed by "t" test of Student and the results were as follows: the highest values of the diameter of the circle formed by the cement were obtained in LS Cement (Vigodent) (p <0.05). It was concluded that zinc phosphate cement LS (Vigodent) showed greater flow in comparison with zinc cement (White SS).


Assuntos
Cimentos Dentários , Escoamento Superficial
15.
Rev. flum. odontol ; 17(36): 53-58, jul.-dez. 2011. graf
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-638429

RESUMO

O objetivo deste trabalho foi avaliar as alterações dimensionais de moldes de alginato quando se emprega a técnica de reembasamento.A partir de um modelo padrão em aço inoxidável, contendo duas marcações, foram realizadas moldagens com AlginatoEzactKromm (Vigodent) e os modelos de gesso foram confeccionados com o gesso tipo IV Durone (Dentsply). As moldagensforam divididas em 2 grupos: Grupo I – 10 moldagens com alginato sem reembasamento e; Grupo II – 10 moldagens com o alginatoutilizando o reembasamento. Os modelos de gesso foram confeccionados com espatulação a vácuo e levados ao Microscópio Comparador Mitutoyo para obtenção das medidas que foram comparadas com o modelo padrão de aço inoxidável. Os dados foram submetidos a análise estatística através do teste “t” de Student e obtivemos os seguintes resultados: houve alteração dimensional estatisticamente significante no Grupo II (p<0,05) em comparação com o Grupo I e o modelo padrão. Concluiu-se que não é recomendado a realização da técnica de reembasamento em moldagem com Alginato, devido a alteração dimensional observada.


The aim of this study was to evaluate the dimensional changes in alginate molds when employing the technique of relining. Froma standard stainless steel, with two appointments were made with alginate impressions EzactKromm (Vigodent) and plaster casts were made of gypsum type IV Durone (Dentsplay). The casts were divided into two groups: Group I – 10 impressions without relining and Group II – 10 inpressions with alginate using the relining. The plaster casts were made with vacuum mixing and taken to the Comparator Mitutoyo Microscope to obtain measures that were compared with the standard model of stainless steel. The data were statistically analyzed by t test of Student and obtained the following results: there was a statistically significant dimensional changes in Group II (p <0.05) compared with Group I and the standard model. It was concluded that it is not recommended to perform the technique of relining impression with alginate in, because the dimensional changes observed.


Assuntos
Materiais para Moldagem Odontológica , Odontologia
16.
Rev. flum. odontol ; 16(34): 36-42, jul.-dez. 2010. graf
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-605629

RESUMO

O objetivo desse trabalho foi identificar contaminação em moldes, assim como, estabelecer a eficácia da solução desinfetante para utilização nas clínicas da FOCampos. Foram usadas 176 moldagens obtidas de pacientes da FOCampos, nas quais foi realizada a coleta do material utilizando dois “swabs” em solução salina. Logo em seguida à remoção do molde da boca e ser lavado com água corrente, foi feita a primeira coleta com o “swab” passado na superfície do molde e em seguida introduzido na salina. A seguir, foi realizada a desinfecção do molde com hipoclorito de Na a 1% sob a forma de aerossol e colocado em plástico auto-adesivo por 10 minutos. Terminando o tempo e após a lavagem do molde, nova coleta foi feita. Ambos os “swabs” foram introduzidos em tubos de ensaio com o meio tioglicolato, e incubados por 72 horas à 37oC. Após este período, foi observada a turvação pela inspeção visual considerando os escores (0 = ausência de turvação; + = turvação discreta; ++ = turvação moderada; +++ = turvação intensa). Os dados foram submetidos a uma análise estatística descritiva para a obtenção dos seguintes resultados: na primeira coleta, 73,86% dos moldes apresentaram leve contaminação; 15,91% moderada, 7,95% intensa e 2,27% não apresentaram contaminação. Após a desinfecção, na segunda coleta, 95,45% dos moldes não apresentaram contaminação; 3,98% discreta contaminação e 0,57% moderada. Pode-se concluir que houve contaminação em todas as moldagens obtidas; a desinfecção foi eficaz na maioria das moldagens e o procedimento deve ser adotado rotineiramente nas clínicas da FOCampos.


The aim of this study was to identify contamination in molds, as well as establish the efficacy of disinfectant solution for use in clinical FOCampos. One hundred and seventy-sic impressions were used from patients of FOCampos, in which was collected the material using two swabs in saline. Soon after the removal of the casto f the mouth and washed with water, was made the first collection with the swab past the surface of the mold and then inserted into the saline. They were then carried out disinfection of the mold with sodium hypochlorite at 1% in the formo f aerosol and placed in plastic self-adhesive for 10 minutes. After the time and after washing of the mold, the new collection was made. Both swabs were placed in test tubes with thioglycolate middle and incubated for 72 hours at 37oC. After this period, the turbidity was observed by visual inspection considering the scores (0 = no haze; + = slight turbidity, turbidity ++ = moderate +++ = intense turbidity). Data were subjected to descriptive statistical analysis to obtain the following results: the first collection, 73.86% of the molds showed slight contamination, 15.91% moderate, severe 7.95% and 2.27% were not contaminated. After disinfection, the second test, 95.45% of templates were not contaminated, 3.98% and 0.57% discreet moderate contamination. It can be concluded that there was contamination in all the moldings obtained, the disinfection was effective in most casts and the procedure should be adopted routinely in clinical FOCampos.


Assuntos
Clínicas Odontológicas , Desinfecção , Modelos Anatômicos
17.
Rio de Janeiro; s.n; 2008. 107 p. ilus, graf.
Tese em Português | LILACS, BBO - odontologia (Brasil) | ID: biblio-866138

RESUMO

O objetivo deste estudo foi comparar, por meio de mensuração das fendas na interface dentina - restauração de resina composta com utilização de algumas variáveis: fotoativação com lâmpada halógena e com LED; utilização de resina microhíbrida com partículas nanométricas Filtek Z350 ou sem estas partículas Filtek Z250; variação do sistema adesivo (Adper Single Bond 2 ou Adper Scotchbond Multi Purpose); variação da temperatura da resina composta; uso de dessensibilizante dentinário ou não; remoção do colágeno da dentina ou não e variação da intensidade de luz na fotoativação. Foram utilizados 70 molares humanos recém-extraídos, com cavidades circulares na dentina superficial de cada face proximal, foram divididos em 10 amostras para cada variável citada acima. Os dentes foram devidamente restaurados, seguindo as instruções dos fabricantes, para todos os grupos e mantidos em estufa bacteriológica por um período de 7 dias, após este período, foram polidos e as réplicas de resina epoxídica foram confeccionadas a partir de uma moldagem com silicone por adição, as mesmas foram levadas ao MEV, para a análise. As fendas foram mensuradas com o auxílio do software UTHSCSA Image tool e os dados foram submetidos à análise estatística pelo teste “t” de Student para a obtenção dos resultados. Com base nos resultados obtidos pode-se concluir que: os menores valores de fendas marginais foram obtidos quando da utilização de luz halógena (t=3,246 e p= 0,02) e com variação da intensidade desta luz (t= - 8,808 e p= 0,00). Os menores valores relativos de fendas, mas sem diferença estatística significante, foram encontrados, também, quando a resina Filtek Z350 foi comparada com a resina Filtek Z250 (t=-0,426 e p= 0,672) e quando o adesivo Adper Scotchbond Multi Purpose foi comparado com o Sistema Adper Single Bond 2 (t= 0,883 e p= 0,382). Os maiores valores de fendas marginais foram obtidos com a resina Filtek Z350 préaquecida a 60oC (t= -3,961 e p=0,000); com o uso de ...


The objective of this study was to compare through the cracks measurements in the dentin – resin interface, using some variables: light activation with halogenic lamp and with LED; the use of micro-hybrid resin with or without nanofiller (Filtek Z350 anda Filtek Z250); variation of the adhesive systems (Adper Single Bond 2 or Scotchbond Multi Purpose); variation of the temperature in the compound resin; to use or not use the dentin desensitizing; to remove or not the dentin collagen and the light intensity variation in the light-curing. It was used 70 human extracted molars, with circular cavities in the superficial dentin of each proximal face; they were divided in 10 samples to each supra cited variable. The teeth were restored, followint the manufacturer instructions, and they were kept in a bacteriologtical kiln during a seven days period. After this time, the teeth were glossed, the resin replica were made from an addition silicone casting and these were took to the MEV, to be analyzed. The cracks were measured with the help of a UTHSCSA tool image software and the data were submited to an statistical analysis with the Student t test. The results obtained give the following conclusions: the lower values of marginal cracks were obtained when it was used the halogenic light (t = 3,246 and p = 0,02) and due the intensity variation of this light (t = 8,808 and p = 0,00). The lowest values related to the cracks were found when the Filtek Z350 resin was compared to the Filtek Z250 resin (t = 0,426 and p = 0,672), and when the Adper Scotchbond Multipurpose adhesive was compared with the Adper Single Bond 2 system (t = 0,883 and p = 0,382). The greatest values of marginal cracks were obtained with Filtek Z350 resin preheated at 60 degrees (t = -3,961 and p = 0,00); with the use of dentin desensitizing (t = -3,062 and p = 0,004) and with the removal of the collagen by using sodium hypochlorite (t = -8,808 and p = 0,000). (AU)


Assuntos
Humanos , Resinas Compostas , Adaptação Marginal Dentária , Restauração Dentária Permanente , Lâmpadas de Polimerização Dentária , Cimentos Dentários , Dentina , Microscopia Eletrônica de Varredura , Dente Molar
18.
Rio de Janeiro; s.n; 2008. 107 p. ilus, graf.
Tese em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-673669

RESUMO

O objetivo deste estudo foi comparar, por meio de mensuração das fendas na interface dentina - restauração de resina composta com utilização de algumas variáveis: fotoativação com lâmpada halógena e com LED; utilização de resina microhíbrida com partículas nanométricas Filtek Z350 ou sem estas partículas Filtek Z250; variação do sistema adesivo (Adper Single Bond 2 ou Adper Scotchbond Multi Purpose); variação da temperatura da resina composta; uso de dessensibilizante dentinário ou não; remoção do colágeno da dentina ou não e variação da intensidade de luz na fotoativação. Foram utilizados 70 molares humanos recém-extraídos, com cavidades circulares na dentina superficial de cada face proximal, foram divididos em 10 amostras para cada variável citada acima. Os dentes foram devidamente restaurados, seguindo as instruções dos fabricantes, para todos os grupos e mantidos em estufa bacteriológica por um período de 7 dias, após este período, foram polidos e as réplicas de resina epoxídica foram confeccionadas a partir de uma moldagem com silicone por adição, as mesmas foram levadas ao MEV, para a análise. As fendas foram mensuradas com o auxílio do software UTHSCSA Image tool e os dados foram submetidos à análise estatística pelo teste “t” de Student para a obtenção dos resultados. Com base nos resultados obtidos pode-se concluir que: os menores valores de fendas marginais foram obtidos quando da utilização de luz halógena (t=3,246 e p= 0,02) e com variação da intensidade desta luz (t= - 8,808 e p= 0,00). Os menores valores relativos de fendas, mas sem diferença estatística significante, foram encontrados, também, quando a resina Filtek Z350 foi comparada com a resina Filtek Z250 (t=-0,426 e p= 0,672) e quando o adesivo Adper Scotchbond Multi Purpose foi comparado com o Sistema Adper Single Bond 2 (t= 0,883 e p= 0,382). Os maiores valores de fendas marginais foram obtidos com a resina Filtek Z350 préaquecida a 60oC (t= -3,961 e p=0,000); com o uso de...


The objective of this study was to compare through the cracks measurements in the dentin – resin interface, using some variables: light activation with halogenic lamp and with LED; the use of micro-hybrid resin with or without nanofiller (Filtek Z350 anda Filtek Z250); variation of the adhesive systems (Adper Single Bond 2 or Scotchbond Multi Purpose); variation of the temperature in the compound resin; to use or not use the dentin desensitizing; to remove or not the dentin collagen and the light intensity variation in the light-curing. It was used 70 human extracted molars, with circular cavities in the superficial dentin of each proximal face; they were divided in 10 samples to each supra cited variable. The teeth were restored, followint the manufacturer instructions, and they were kept in a bacteriologtical kiln during a seven days period. After this time, the teeth were glossed, the resin replica were made from an addition silicone casting and these were took to the MEV, to be analyzed. The cracks were measured with the help of a UTHSCSA tool image software and the data were submited to an statistical analysis with the Student t test. The results obtained give the following conclusions: the lower values of marginal cracks were obtained when it was used the halogenic light (t = 3,246 and p = 0,02) and due the intensity variation of this light (t = 8,808 and p = 0,00). The lowest values related to the cracks were found when the Filtek Z350 resin was compared to the Filtek Z250 resin (t = 0,426 and p = 0,672), and when the Adper Scotchbond Multipurpose adhesive was compared with the Adper Single Bond 2 system (t = 0,883 and p = 0,382). The greatest values of marginal cracks were obtained with Filtek Z350 resin preheated at 60 degrees (t = -3,961 and p = 0,00); with the use of dentin desensitizing (t = -3,062 and p = 0,004) and with the removal of the collagen by using sodium hypochlorite (t = -8,808 and p = 0,000).


Assuntos
Humanos , Resinas Compostas , Adaptação Marginal Dentária , Restauração Dentária Permanente , Lâmpadas de Polimerização Dentária , Cimentos Dentários , Dentina , Microscopia Eletrônica de Varredura , Dente Molar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA