1.
Int J Mol Sci ; 20(9)2019 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-31075984

RESUMO

PURPOSE: The objective of this study was to assess the influence of a novel surface of dental implants (ContacTi®) on the osseointegration process in a minipig model. The surface was compared with other existing surfaces on the market (SLA® and SLActive®) by employing bone implant contact analysis (BIC) and implant stability. METHOD: Twelve minipigs were used with prior authorisation from an ethics committee. Three types of surfaces were tested: SLA® (sand-blasted acid-etched titanium), SLActive® (same but hydrophilic, performed under a nitrogen atmosphere), and ContacTi® (alumina particle bombardment of titanium, bioactivated when treated thermochemically) in 4.1 mm × 8 mm implants with internal connection and a polished neck. Twelve implants of each surface type (N = 36) were placed, sacrificing 1/3 of the animals at 2 weeks of placement, 1/3 at 4 weeks and the remaining 1/3 at 8 weeks. Numerical variables were compared with Analysis of Variance, and the correlation between ISQ and BIC was established with the Spearman's rank correlation coefficient. RESULTS: SLActive® and ContacTi® surfaces showed elevated osteoconductivity at 4 weeks, maintaining a similar evolution at 8 weeks (large amount of mature lamellar tissue with high maturity and bone quality). The SLA® surface showed slower maturation. The ISQ values in surgery were elevated (above 65), higher at necropsy and higher at 4 and 8 weeks in the SLA® group than in the other two (SLActive® and ContacTi®). No significant correlation was found between ISQ and BIC for each implant surface and necropsy time. CONCLUSION: The three surfaces analysed showed high RFA and BIC values, which were more favourable for the SLActive® and ContacTi® surfaces. No statistical correlation was found between the RFA and BIC values in any of the three surfaces analysed.


Assuntos
Materiais Biocompatíveis/farmacologia , Implantes Dentários , Osseointegração , Animais , Osso e Ossos/efeitos dos fármacos , Osso e Ossos/patologia , Feminino , Osseointegração/efeitos dos fármacos , Propriedades de Superfície , Suínos , Porco Miniatura
2.
Clin Oral Investig ; 22(3): 1423-1432, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29022215

RESUMO

OBJECTIVES: The objective of this study was to assess, by histomorphometric analysis, the degree of bone apposition on two types of dental implant's surfaces: a novel implant that combines Al2O3 abrasive particle blasting with thermochemical treatment (ContacTi), compared to a standard surface treatment obtained by sandblasting and acid etching (shot blasting). MATERIALS AND METHODS: Twelve minipigs were used, placing the studied implants in the maxillae, and divided into three groups according to the time of sacrifice: 2, 4, and 8 weeks after implant placement. Histological and histomorphometric analyses were performed following standardized tissue polymerization, cutting, and staining and examined under optical and high-resolution electron microscope. RESULTS: For all measurements, the novel surface presented higher levels of osseointegration as compared to the shot blasting surface. Bone to implant contact (BIC) in the maxillae for ContacTi presented values of 49.02, 83.20, and 85.58% at 2, 4, and 8 weeks, respectively, significantly higher compared to the shot blasting surface values of 39.32, 46.53, and 46.20% for the same time points. Bone area density (BAD) presented values of 26.52, 61.21, and 59.50% for ContacTi surface implants and 22.95, 36.26, and 49.50% for the shot blasted surface implants. Signs of osteoconductivity were observed in the ContacTi surfaces at 2 weeks. CONCLUSIONS: The ContacTi surface achieved a faster growth of hard tissues around the implants, when compared to the shot blasting surface, and for all evaluated histomorphometric parameters, the values were higher at all measured time points. CLINICAL RELEVANCE: ContacTi could be a new surface improving the osseointegration in oral implantology.


Assuntos
Interface Osso-Implante/fisiologia , Implantes Dentários , Planejamento de Prótese Dentária , Osseointegração/fisiologia , Condicionamento Ácido do Dente , Abrasão Dental por Ar , Óxido de Alumínio , Animais , Feminino , Maxila , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Suínos , Porco Miniatura , Titânio
3.
Implant Dent ; 24(5): 607-11, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26288162

RESUMO

PURPOSE: To evaluate the micromobility of dental implants under occlusal loading in relation to stability measurements of resonance frequency analysis and insertion torque. MATERIALS AND METHODS: The sample comprised of 24 implants inserted in 12 fresh cow ribs. Insertion torque and Osstell implant stability quotient (ISQ) measurements were recorded. An "ad hoc" acrylic premolar was made on a temporary abutment and screwed to each implant, and a force of 100 N was subsequently applied at an angle of 6 degrees. Implant micromotion was measured using a Questar microscope with a resolution of 2 µm and an image analysis program. RESULTS: Data show a statistically significant inverse correlation between the ISQ values and implant micromotion under a load of 100 N (R = 0.86, P < 0.0001). The same relationship is found between insertion torque and implant micromotion, although the relationship is linear up to 34 N·cm and becomes exponential for higher values (R = 0.78, P < 0.0001). A direct correlation is established between insertion torque and ISQ values. CONCLUSION: There is an inverse relationship between both ISQ and insertion torque values and implant micromotion under a load of 100 N.


Assuntos
Implantes Dentários/normas , Animais , Bovinos , Projeto do Implante Dentário-Pivô/métodos , Projeto do Implante Dentário-Pivô/normas , Implantação Dentária Endóssea/métodos , Implantação Dentária Endóssea/normas , Análise do Estresse Dentário , Técnicas In Vitro , Magnetismo , Torque , Vibração
4.
Med Oral Patol Oral Cir Bucal ; 18(4): e721-4, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23722142

RESUMO

UNLABELLED: NiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the austenitic retransformation during the unloading. The temperature variations induced changes in the spring force. OBJECTIVES: The aim of this study is to investigate the effect of the temperature variations in the spring forces and corrosion behaviour simulating the ingestion hot/cold drinks and food. STUDY DESIGN: The springs were subjected to a tensile force using universal testing machine MTS-Adamel (100 N load cell). All tests were performed in artificial saliva maintained at different temperatures. The corrosion tests were performed according to the ISO-standard 10993-15:2000. RESULTS: The increase in temperature of 18 °C induced an increase in the spring force of 30%. However, when the temperature returns to 37 °C the distraction force recovers near the initial level. After cooling down the spring to 15 °C, the force decreased by 46%. This investigation show as the temperature increase, the corrosion potential shifts towards negative values and the corrosion density is rising. CONCLUSIONS: The changes of the temperatures do not modify the superelastic behaviour of the NiTi closed-coil springs. The corrosion potential of NiTi in artificial saliva is decreasing by the rise of the temperatures.


Assuntos
Fios Ortodônticos , Temperatura , Teste de Materiais , Fenômenos Físicos
5.
Artigo em Inglês | MEDLINE | ID: mdl-35409826

RESUMO

Articles on the prevalence of peri-implant diseases showed that 90% of peri-implant tissues had some form of inflammatory response and a prevalence of peri-implantitis from 28% to 51% according to various publications. Objective: To provide an overview of how risk factors can be related with peri-implantitis. Methods: A retrospective longitudinal study including 555 implants placed in 132 patients was evaluated based on the presence of peri-implantitis following the criteria of Renvert et al. 2018. Results: In total, 21 patients (15.9%) suffered peri-implantitis (PPG) and 111 patients (84.1%) did not suffer peri-implantitis (NPG). The results reveal that smokers have a high incidence of peri-implantitis (72.7%) compared to non-smokers (27.3%) (p < 0.0005). Another variable with significant results (p < 0.01) was periodontitis: 50% PPG and 23.9% NPG suffered advanced periodontitis. Systemic diseases such as arterial hypertension, diabetes mellitus, osteoporosis, and cardiovascular diseases do not show a statistically significant influence on the incidence of peri-implantitis. Patients who did not attend their maintenance therapy appointment had an incidence of peri-implantitis of 61.4%, compared to 27.3% in those who attend (p < 0.0001). From the results obtained, we can conclude that relevant factors affect peri-implantitis, such as tobacco habits, moderate and severe periodontitis, and attendance in maintenance therapy.


Assuntos
Peri-Implantite , Periodontite , Humanos , Incidência , Estudos Longitudinais , Peri-Implantite/epidemiologia , Peri-Implantite/etiologia , Periodontite/complicações , Periodontite/epidemiologia , Estudos Retrospectivos , Fatores de Risco
6.
Artigo em Inglês | MEDLINE | ID: mdl-33348644

RESUMO

Aim: (PRIMARY) Assess the changes in bone level (6 and 12 months after implant placement) between the test (definitive abutment (DEF)) and control (healing abutment (HEA)) groups. (SECONDARY) Assess the changes in bone level (6 and 12 months after implant placement) between the 1 mm high abutment group and 2 mm abutment group. Evaluate changes in implant stability recorded with analysis of the resonance frequency (RFA) Osstell system, at 6 and 12 months after implant placement, between the control group (HEA) and test (DEF). For the DEF group, the abutment was placed at the time of the surgery and was never removed. For the HEA group, the abutment was removed three times during the manufacture of the crowns. The abutments used were 1 mm high (Subgroup A) and 2 mm high (Subgroup B). Materials and methods: A total of 147 patients were selected between 54.82 ± 11.92 years old. After implant placement, patients were randomly distributed in the DEF and HEA group. After the implant placement, a periapical radiograph was taken to assess the peri-implant bone level; the same procedure was carried out 6 and 12 months post-placement. To compare the qualitative variables between the groups (HEA/DEF), the Chi-square test was used; for quantitative (MANOVA). Results: After a year, the accumulated bone loss was 0.48 ± 0.71 mm for the HEA group and 0.36 ± 0.79 mm for the DEF group, without statistical significance. Differences were only found due to timing (time) between 0 and 6 months (=0.001) and 0 and 12 months (0.001), with no differences attributable to the study groups (DEF and HEA). The accumulated bone loss (1 year) was 0.45 ± 0.78 mm for the 1 mm abutment group and 0.41 ± 0.70 mm for the 2 mm abutment group (p = 0.02). No differences were observed in implant stability between groups. Conclusions: The "One Abutment-One Time" concept does not reduce peri-implant bone loss compared to the connection-disconnection technique. The height of the abutment does influence bone loss: the higher the abutment, the lower the bone loss.


Assuntos
Perda do Osso Alveolar/diagnóstico , Dente Suporte , Implantes Dentários para Um Único Dente , Adulto , Idoso , Projeto do Implante Dentário-Pivô , Implantação Dentária Endóssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Resultado do Tratamento
7.
Biomed Res Int ; 2017: 2785863, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29318142

RESUMO

The objective of the study is to characterise the mechanical properties of Ti-15Zr binary alloy dental implants and to describe their biomechanical behaviour as well as their osseointegration capacity compared with the conventional Ti-6Al-4V (TAV) alloy implants. The mechanical properties of Ti-15Zr binary alloy were characterised using Roxolid© implants (Straumann, Basel, Switzerland) via ultrasound. Their biomechanical behaviour was described via finite element analysis. Their osseointegration capacity was compared via an in vivo study performed on 12 adult rabbits. Young's modulus of the Roxolid© implant was around 103 GPa, and the Poisson coefficient was around 0.33. There were no significant differences in terms of Von Mises stress values at the implant and bone level between both alloys. Regarding deformation, the highest value was observed for Ti-15Zr implant, and the lowest value was observed for the cortical bone surrounding TAV implant, with no deformation differences at the bone level between both alloys. Histological analysis of the implants inserted in rabbits demonstrated higher BIC percentage for Ti-15Zr implants at 3 and 6 weeks. Ti-15Zr alloy showed elastic properties and biomechanical behaviours similar to TAV alloy, although Ti-15Zr implant had a greater BIC percentage after 3 and 6 weeks of osseointegration.


Assuntos
Ligas/química , Implantes Dentários , Teste de Materiais , Estresse Mecânico , Animais , Análise de Elementos Finitos , Humanos , Coelhos